Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Instruction Manual RFL 9745 Teleprotection Channel

Manual · RFL

Instruction Manual RFL 9745 Teleprotection Channel

Manual394 pagesPDF 6.3 MB

Instruction manual for the RFL 9745 Teleprotection Channel in audio-tone and digital versions: installation, programming and maintenance.

Download the PDF6.3 MB

Covers · 1 model

The models it covers

Summary

What is in it

The full instruction manual for the RFL 9745 Teleprotection Channel from RFL Electronics. It describes the system's modules (CPU, driver, audio and digital communications, interface modules, fiber service unit, SWC I/O, power supply), the logic and alarm programming language, installation, jumper settings and commissioning procedures, access and programming over the RS-232 ports, the front-panel controls, maintenance and fuse replacement, the PC APRIL LITE software and the UCA interface module.

Its parts

  1. Product Information
  2. System Overview
  3. Installation
  4. Using the RS-232 Ports to Access the RFL 9745
  5. RFL 9745 Audio and Digital System Parameters
  6. Using the RS-232 Ports to Program and Operate the RFL 9745
  7. Using the 9745 Front-Panel Controls
  8. Maintenance
  9. Using PC APRIL LITE
  10. UCA Interface Module
  11. Accessory Equipment and System Drawings

From the manual

Key facts from this manual

Each line names its page in the PDF.

Instruction manual MC9745, revised February 24, 2009, for the RFL 9745 Teleprotection Channel, a programmable unit for transfer trip, blocking and unblocking schemes over audio tone, digital or fiber optic links. It covers the modules, installation, jumper and parameter settings, programming over the RS-232 ports with APRIL, the front-panel controls, maintenance, the PC APRIL Lite software and the UCA interface module.

Read for this summary: pages 1 to 7, 23 to 24, 30 to 31, 49, 104, 298 to 301 and 312 to 313 of 394.

Device
Programmable teleprotection channel for Direct Transfer Trip, Permissive Transfer Trip, Blocking and Unblocking p. 23
Functions
Up to four independent functions per audio system, seven for digital or fiber p. 23
Power supply
48/125 Vdc supply: 38 to 150 Vdc; 250Vdc supply: 170 to 300 Vdc; single or redundant p. 30
Power supply modules
Three types: 105905 (38-150 Vdc), 105930 (170-300 Vdc) and 105905-1 p. 104
Power terminals
TB1-9 positive, TB1-10 negative; redundant supply on TB3-9 and TB3-10 p. 104
Input fuses
105905 and 105930 supplies: Littlefuse 218002 (RFL 103389); 105905-1 supply: Littlefuse 218004 (RFL 301122) p. 313
CPU and software
New system software only for CPU modules 107335-X; SW9745SY201 (Version 7.0) and SW9745SY301 (Version 8.0 Australia) cannot load into 105025-X or 107330-X p. 1
Interface modules
One of eleven digital interface modules: five serial (SIO) and six fiber (FIO), plugged into the upper rear panel p. 49
Fiber Service Unit
107460-x; remote RS-449, G.703, V.35 or X.21 port up to 2km from a 9745 with Short Haul Fiber I/O module 107310 p. 49
Crash codes
0x03 address error; 0x10 or 0x11 BIOS misalignment; 0x47 driver queue overrun; 0x48 comms queue overrun; 0x49 download complete; 0x4A download failure p. 301
Diagnostics
100 sequence-of-events records, IRIG-B clock sync input, checkback testing, channel propagation delay measurement p. 24
Operate time
Digital and fiber systems: 3 ms maximum in the most secure mode p. 30
Temperature
Operating -30° C to +65° C; storage -40° C to +75° C p. 30
Chassis
Standard 19-inch rack, three rack-units high (5.25 inches or 13.3 cm); I/O plug-in connectors take #14 AWG wire p. 30

What this manual walks you through

  • Connecting input power and matching the power supply module to the supply voltage p. 104
  • Checking and replacing the power supply fuses p. 312, 313
  • Using the built-in diagnostics to find a faulty module p. 298, 299
  • Address and checkback testing between local and remote units p. 299
  • Running the quick and long power-up self tests p. 300
  • Reading BIOS crash codes p. 301
  • Choosing a serial or fiber digital interface module p. 49
  • Reading a sequence-of-events record p. 24

Good to know

  • Check that the installed power supply module suits the available input voltage before connecting power; the wrong voltage can damage components. p. 104
  • Power must be off before removing or installing any RFL 9745 module. p. 7
  • Never remove or replace a fuse with a power supply module energized, and replace a fuse only with one of the same ratings. p. 312
  • After fitting a different power supply model, change the input voltage label inside the front door. p. 104
  • Fiber optic modules may use a laser source with invisible radiation; never look into the light beam. p. 5

Questions this manual answers

What does crash code 0x4A mean on an RFL 9745?

System download failure; the manual says to reattempt the download. Code 0x49 means the download completed and the system is restarting. p. 301

What fuse does the RFL 9745 power supply use?

The 105905 and 105930 supplies use Littlefuse 218002 (RFL part 103389); the 105905-1 supply uses Littlefuse 218004 (RFL part 301122). p. 313

Which CPU module does the current RFL 9745 software need?

CPU module 107335-X. The software cannot be loaded into chassis with CPU part numbers 105025-X or 107330-X. p. 1

How do I run the full power-up self test on the RFL 9745?

Press and hold the test button on the front panel during power on; this adds EEROM and FLASH tests to the quick tests. p. 300

Where is input power connected on the RFL 9745?

On rear-panel terminal block TB1, positive to TB1-9 and negative to TB1-10; a redundant supply also uses TB3-9 and TB3-10. p. 104

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. SAFETY WARNINGS AND SUMMERY5
  2. LIST OF ILLUSTRATIONS11
  3. LIST OF TABLES14
  4. Section 1. PRODUCT INFORMATION21
  5. Section 2. SYSTEM OVERVIEW35
    1. 2.1 INTRODUCTION35
    2. 2.2 RFL 9745 MODULES35
    3. 2.3 SYSTEM OPERATION (AUDIO-TONE UNITS ONLY)53
    4. 2.4 SPECIAL FEATURES56
    5. 2.5 ADDRESS TESTING OR CHECKBACK TESTING (AUTOTEST)57
    6. 2.6 PING PONG TESTING59
    7. 2.7 LOGIC/ALARM PROGRAMMING LANGUAGE61
    8. 2.8 9745 FILE DESCRIPTIONS66
    9. 2.9 INPUTS AND OUTPUTS68
  6. Section 3. INSTALLATION84
    1. 3.1 INTRODUCTION84
    2. 3.2 UNPACKING84
    3. 3.3 MOUNTING85
    4. 3.4 VENTILATION87
    5. 3.5 CONNECTIONS87
    6. 3.6 JUMPER SETTINGS AND SWITCH SETTINGS106
    7. 3.7 COMMISSIONING PROCEDURES143
    8. 3.8 WIDEBAND AUDIO COMMUNICATIONS MODULE UPGRADE INSTALLATION INSTRUCTIONS153
    9. 3.9 CONVERTING AN AUDIO TONE 9745 TO A DIGITAL 9745158
  7. Section 4. USING THE RS-232 PORTS TO ACCESS THE RFL 9745160
    1. 4.1 INTRODUCTION160
    2. 4.2 ACCESSING THE RFL 9745 FROM A PC OR TERMINAL160
  8. Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS168
    1. 5.1 INTRODUCTION168
    2. 5.2 RFL 9745 AUDIO SYSTEM PARAMETERS168
    3. 5.3 RFL 9745 DIGITAL SYSTEM PARAMETERS173
    4. 5.4 RFL 9745 COMMON PARAMETERS (FOR AUDIO AND DIGITAL SYSTEMS)175
    5. 5.5 RECOMMENDED PARAMETER SETTINGS177
    6. 5.6 RECOMMENDED CHANNEL GROUPINGS FOR SINGLE-PORT FOUR-CHANNEL SYSTEMS188
    7. 5.7 RECEIVER OFFSET FOR BOOST APPLICATIONS189
  9. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745190
    1. 6.1 INTRODUCTION190
    2. 6.2 VIEWING APRIL COMMANDS190
    3. 6.3 DISPLAYING APRIL HELP191
53 more lines, from page 192 on
  1. 6.4 PASSWORD PROTECTION192
    1. 6.5 VIEWING THE ALARMS DISPLAY194
    2. 6.6 VIEWING THE VALUES DISPLAY199
    3. 6.7 THE PROGRAMMING MODE202
    4. 6.8 READING PARAMETER SETTINGS212
    5. 6.9 VIEWING CONFIGURATION AND SOFTWARE INFORMATION213
    6. 6.10 THE LOGIC PROGRAMMING MODE217
    7. 6.11 THE TEST MODE243
    8. 6.12 THE UPDATE MODE251
    9. 6.13 THE SEQUENCE-OF-EVENTS MODE255
    10. 6.14 ADVANCED PARAMETERS OPTION262
    11. 6.15 THE WINDOW REMOTE APRIL MODE267
    12. 6.16 RETURNING TO NORMAL RFL 9745 OPERATION268
  2. Section 7. USING THE 9745 FRONT-PANEL CONTROLS270
    1. 7.1 INTRODUCTION270
    2. 7.2 FRONT PANEL DISPLAY DURING NORMAL OPERATION271
    3. 7.3 FRONT PANEL DISPLAY WHEN ALARM(S) ARE ACTIVE271
    4. 7.4 ADJUSTING DISPLAY CONTRAST272
    5. 7.5 SELECTING AND USING FRONT-PANEL MENUS272
    6. 7.6 SHORT HAUL FIBER I/O MODULE FRONT PANEL INDICATORS297
    7. 7.7 FIBER SERVICE UNIT FRONT AND REAR PANEL INDICATORS297
  3. Section 8. MAINTENANCE298
    1. 8.1 INTRODUCTION298
    2. 8.2 DIAGNOSTICS298
    3. 8.3 TROUBLESHOOTING301
    4. 8.4 REMOVAL AND REPLACEMENT304
    5. 8.5 FUSE REPLACEMENT312
    6. 8.6 HOW TO ARRANGE FOR SERVICING315
  4. Section 9. USING PC APRIL LITE316
    1. 9.1 PC APRIL LITE FOR WINDOWS 2000 AND XP, OVERVIEW316
    2. 9.2 LOADING PC APRIL LITE317
    3. 9.3 PC APRIL LITE CAPABILITIES318
    4. 9.4 ESTABLISHING COMMUNICATIONS318
    5. 9.5 DOWNLOADING LOGIC AND PARAMETER FILES FROM THE 9745320
    6. 9.6 UPLOADING LOGIC, PARAMETER AND SYSTEM FILES TO THE 9745323
    7. 9.7 UPLOADING A CRASHED 9745325
    8. 9.8 SAVING 9745 DISPLAYS, EVENTS, AND LOGS325
    9. 9.9 AUTOMATIC UPGRADE325
    10. 9.10 PC APRIL DOS MODE326
  5. Section 10. UCA INTERFACE MODULE336
    1. 10.1 INTRODUCTION336
    2. 10.2 INSTALLATION337
    3. 10.3 RS-232 CABLE CONNECTIONS338
    4. 10.4 IP CONFIGURATION339
    5. 10.5 PORT REPLICATION340
    6. 10.6 UCA PARAMETERS340
    7. 10.7 FILE MANAGEMENT340
    8. 10.8 USING THE BUILT-IN WEB SERVER342
    9. 10.9 ILLUSTRATIONS OF THE UCA CONFIGURATION WEB SERVER344
  6. Section 11. GLOSSARY OF TERMS356
  7. Section 12. INDEX370
  8. Section 13. ACCESSORY EQUIPMENT AND SYSTEM DRAWINGS380
  9. Home1

From the PDF’s own bookmarks.

The whole text · 43 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. SAFETY WARNINGS AND SUMMERY5-7
  3. TABLE OF CONTENTS8-10
  4. LIST OF ILLUSTRATIONS11-13
  5. LIST OF TABLES14-20
  6. Section 1. PRODUCT INFORMATION21-34
  7. Section 2. SYSTEM OVERVIEW, pages 35 to 4435-44
  8. Section 2. SYSTEM OVERVIEW, pages 45 to 5445-54
  9. Section 2. SYSTEM OVERVIEW, pages 55 to 6455-64
  10. Section 2. SYSTEM OVERVIEW, pages 65 to 7465-74
  11. Section 2. SYSTEM OVERVIEW, pages 75 to 8375-83
  12. Section 3. INSTALLATION, pages 84 to 9384-93
  13. Section 3. INSTALLATION, pages 94 to 10394-103
  14. Section 3. INSTALLATION, pages 104 to 113104-113
  15. Section 3. INSTALLATION, pages 114 to 123114-123
  16. Section 3. INSTALLATION, pages 124 to 133124-133
  17. Section 3. INSTALLATION, pages 134 to 143134-143
  18. Section 3. INSTALLATION, pages 144 to 153144-153
  19. Section 3. INSTALLATION, pages 154 to 159154-159
  20. Section 4. USING THE RS-232 PORTS TO ACCESS THE RFL 9745160-167
  21. Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 168 to 175168-175
  22. Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 176 to 183176-183
  23. Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 184 to 189184-189
  24. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 190 to 199190-199
  25. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 200 to 209200-209
  26. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 210 to 219210-219
  27. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 220 to 229220-229
  28. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 230 to 239230-239
  29. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 240 to 249240-249
  30. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 250 to 259250-259
  31. Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 260 to 269260-269
  32. Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 270 to 279270-279
  33. Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 280 to 289280-289
  34. Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 290 to 297290-297
  35. Section 8. MAINTENANCE, pages 298 to 306298-306
  36. Section 8. MAINTENANCE, pages 307 to 315307-315
  37. Section 9. USING PC APRIL LITE, pages 316 to 325316-325
  38. Section 9. USING PC APRIL LITE, pages 326 to 335326-335
  39. Section 10. UCA INTERFACE MODULE, pages 336 to 345336-345
  40. Section 10. UCA INTERFACE MODULE, pages 346 to 355346-355
  41. Section 11. GLOSSARY OF TERMS356-369
  42. Section 12. INDEX370-379
  43. Section 13. ACCESSORY EQUIPMENT AND SYSTEM DRAWINGS380-394

The file

Revision and size

RevisionPublication Number MC9745, Revised February 24, 2009
PublisherRFL Electronics Inc.
Pages394
PDF6.3 MB
TextText from the PDF itself; pages 31, 32 and 33 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 394

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 394
Page 2
Page 2of 394
Page 3
Page 3of 394

More documents · 1

For the same models