Manual · RFL
Instruction Manual RFL 9745 Teleprotection Channel
Manual394 pagesPDF 6.3 MB
Instruction manual for the RFL 9745 Teleprotection Channel in audio-tone and digital versions: installation, programming and maintenance.
Covers · 1 model
The models it covers
Summary
What is in it
The full instruction manual for the RFL 9745 Teleprotection Channel from RFL Electronics. It describes the system's modules (CPU, driver, audio and digital communications, interface modules, fiber service unit, SWC I/O, power supply), the logic and alarm programming language, installation, jumper settings and commissioning procedures, access and programming over the RS-232 ports, the front-panel controls, maintenance and fuse replacement, the PC APRIL LITE software and the UCA interface module.
Its parts
- Product Information
- System Overview
- Installation
- Using the RS-232 Ports to Access the RFL 9745
- RFL 9745 Audio and Digital System Parameters
- Using the RS-232 Ports to Program and Operate the RFL 9745
- Using the 9745 Front-Panel Controls
- Maintenance
- Using PC APRIL LITE
- UCA Interface Module
- Accessory Equipment and System Drawings
From the manual
Key facts from this manual
Each line names its page in the PDF.
Instruction manual MC9745, revised February 24, 2009, for the RFL 9745 Teleprotection Channel, a programmable unit for transfer trip, blocking and unblocking schemes over audio tone, digital or fiber optic links. It covers the modules, installation, jumper and parameter settings, programming over the RS-232 ports with APRIL, the front-panel controls, maintenance, the PC APRIL Lite software and the UCA interface module.
- Device
- Programmable teleprotection channel for Direct Transfer Trip, Permissive Transfer Trip, Blocking and Unblocking p. 23
- Functions
- Up to four independent functions per audio system, seven for digital or fiber p. 23
- Power supply
- 48/125 Vdc supply: 38 to 150 Vdc; 250Vdc supply: 170 to 300 Vdc; single or redundant p. 30
- Power supply modules
- Three types: 105905 (38-150 Vdc), 105930 (170-300 Vdc) and 105905-1 p. 104
- Power terminals
- TB1-9 positive, TB1-10 negative; redundant supply on TB3-9 and TB3-10 p. 104
- Input fuses
- 105905 and 105930 supplies: Littlefuse 218002 (RFL 103389); 105905-1 supply: Littlefuse 218004 (RFL 301122) p. 313
- CPU and software
- New system software only for CPU modules 107335-X; SW9745SY201 (Version 7.0) and SW9745SY301 (Version 8.0 Australia) cannot load into 105025-X or 107330-X p. 1
- Interface modules
- One of eleven digital interface modules: five serial (SIO) and six fiber (FIO), plugged into the upper rear panel p. 49
- Fiber Service Unit
- 107460-x; remote RS-449, G.703, V.35 or X.21 port up to 2km from a 9745 with Short Haul Fiber I/O module 107310 p. 49
- Crash codes
- 0x03 address error; 0x10 or 0x11 BIOS misalignment; 0x47 driver queue overrun; 0x48 comms queue overrun; 0x49 download complete; 0x4A download failure p. 301
- Diagnostics
- 100 sequence-of-events records, IRIG-B clock sync input, checkback testing, channel propagation delay measurement p. 24
- Operate time
- Digital and fiber systems: 3 ms maximum in the most secure mode p. 30
- Temperature
- Operating -30° C to +65° C; storage -40° C to +75° C p. 30
- Chassis
- Standard 19-inch rack, three rack-units high (5.25 inches or 13.3 cm); I/O plug-in connectors take #14 AWG wire p. 30
What this manual walks you through
- Connecting input power and matching the power supply module to the supply voltage p. 104
- Checking and replacing the power supply fuses p. 312, 313
- Using the built-in diagnostics to find a faulty module p. 298, 299
- Address and checkback testing between local and remote units p. 299
- Running the quick and long power-up self tests p. 300
- Reading BIOS crash codes p. 301
- Choosing a serial or fiber digital interface module p. 49
- Reading a sequence-of-events record p. 24
Good to know
- Check that the installed power supply module suits the available input voltage before connecting power; the wrong voltage can damage components. p. 104
- Power must be off before removing or installing any RFL 9745 module. p. 7
- Never remove or replace a fuse with a power supply module energized, and replace a fuse only with one of the same ratings. p. 312
- After fitting a different power supply model, change the input voltage label inside the front door. p. 104
- Fiber optic modules may use a laser source with invisible radiation; never look into the light beam. p. 5
Questions this manual answers
What does crash code 0x4A mean on an RFL 9745?
System download failure; the manual says to reattempt the download. Code 0x49 means the download completed and the system is restarting. p. 301
What fuse does the RFL 9745 power supply use?
The 105905 and 105930 supplies use Littlefuse 218002 (RFL part 103389); the 105905-1 supply uses Littlefuse 218004 (RFL part 301122). p. 313
Which CPU module does the current RFL 9745 software need?
CPU module 107335-X. The software cannot be loaded into chassis with CPU part numbers 105025-X or 107330-X. p. 1
How do I run the full power-up self test on the RFL 9745?
Press and hold the test button on the front panel during power on; this adds EEROM and FLASH tests to the quick tests. p. 300
Where is input power connected on the RFL 9745?
On rear-panel terminal block TB1, positive to TB1-9 and negative to TB1-10; a redundant supply also uses TB3-9 and TB3-10. p. 104
Contents
Chapters and sections
Each line opens the PDF at its page.
- SAFETY WARNINGS AND SUMMERY5
- LIST OF ILLUSTRATIONS11
- LIST OF TABLES14
- Section 1. PRODUCT INFORMATION21
- Section 2. SYSTEM OVERVIEW35
- Section 3. INSTALLATION84
- Section 4. USING THE RS-232 PORTS TO ACCESS THE RFL 9745160
- Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS168
- 5.1 INTRODUCTION168
- 5.2 RFL 9745 AUDIO SYSTEM PARAMETERS168
- 5.3 RFL 9745 DIGITAL SYSTEM PARAMETERS173
- 5.4 RFL 9745 COMMON PARAMETERS (FOR AUDIO AND DIGITAL SYSTEMS)175
- 5.5 RECOMMENDED PARAMETER SETTINGS177
- 5.6 RECOMMENDED CHANNEL GROUPINGS FOR SINGLE-PORT FOUR-CHANNEL SYSTEMS188
- 5.7 RECEIVER OFFSET FOR BOOST APPLICATIONS189
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745190
53 more lines, from page 192 on
- 6.4 PASSWORD PROTECTION192
- 6.5 VIEWING THE ALARMS DISPLAY194
- 6.6 VIEWING THE VALUES DISPLAY199
- 6.7 THE PROGRAMMING MODE202
- 6.8 READING PARAMETER SETTINGS212
- 6.9 VIEWING CONFIGURATION AND SOFTWARE INFORMATION213
- 6.10 THE LOGIC PROGRAMMING MODE217
- 6.11 THE TEST MODE243
- 6.12 THE UPDATE MODE251
- 6.13 THE SEQUENCE-OF-EVENTS MODE255
- 6.14 ADVANCED PARAMETERS OPTION262
- 6.15 THE WINDOW REMOTE APRIL MODE267
- 6.16 RETURNING TO NORMAL RFL 9745 OPERATION268
- Section 7. USING THE 9745 FRONT-PANEL CONTROLS270
- 7.1 INTRODUCTION270
- 7.2 FRONT PANEL DISPLAY DURING NORMAL OPERATION271
- 7.3 FRONT PANEL DISPLAY WHEN ALARM(S) ARE ACTIVE271
- 7.4 ADJUSTING DISPLAY CONTRAST272
- 7.5 SELECTING AND USING FRONT-PANEL MENUS272
- 7.6 SHORT HAUL FIBER I/O MODULE FRONT PANEL INDICATORS297
- 7.7 FIBER SERVICE UNIT FRONT AND REAR PANEL INDICATORS297
- Section 8. MAINTENANCE298
- Section 9. USING PC APRIL LITE316
- 9.1 PC APRIL LITE FOR WINDOWS 2000 AND XP, OVERVIEW316
- 9.2 LOADING PC APRIL LITE317
- 9.3 PC APRIL LITE CAPABILITIES318
- 9.4 ESTABLISHING COMMUNICATIONS318
- 9.5 DOWNLOADING LOGIC AND PARAMETER FILES FROM THE 9745320
- 9.6 UPLOADING LOGIC, PARAMETER AND SYSTEM FILES TO THE 9745323
- 9.7 UPLOADING A CRASHED 9745325
- 9.8 SAVING 9745 DISPLAYS, EVENTS, AND LOGS325
- 9.9 AUTOMATIC UPGRADE325
- 9.10 PC APRIL DOS MODE326
- Section 10. UCA INTERFACE MODULE336
- Section 11. GLOSSARY OF TERMS356
- Section 12. INDEX370
- Section 13. ACCESSORY EQUIPMENT AND SYSTEM DRAWINGS380
- Home1
The whole text · 43 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- SAFETY WARNINGS AND SUMMERY5-7
- TABLE OF CONTENTS8-10
- LIST OF ILLUSTRATIONS11-13
- LIST OF TABLES14-20
- Section 1. PRODUCT INFORMATION21-34
- Section 2. SYSTEM OVERVIEW, pages 35 to 4435-44
- Section 2. SYSTEM OVERVIEW, pages 45 to 5445-54
- Section 2. SYSTEM OVERVIEW, pages 55 to 6455-64
- Section 2. SYSTEM OVERVIEW, pages 65 to 7465-74
- Section 2. SYSTEM OVERVIEW, pages 75 to 8375-83
- Section 3. INSTALLATION, pages 84 to 9384-93
- Section 3. INSTALLATION, pages 94 to 10394-103
- Section 3. INSTALLATION, pages 104 to 113104-113
- Section 3. INSTALLATION, pages 114 to 123114-123
- Section 3. INSTALLATION, pages 124 to 133124-133
- Section 3. INSTALLATION, pages 134 to 143134-143
- Section 3. INSTALLATION, pages 144 to 153144-153
- Section 3. INSTALLATION, pages 154 to 159154-159
- Section 4. USING THE RS-232 PORTS TO ACCESS THE RFL 9745160-167
- Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 168 to 175168-175
- Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 176 to 183176-183
- Section 5. RFL 9745 AUDIO AND DIGITAL SYSTEM PARAMETERS, pages 184 to 189184-189
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 190 to 199190-199
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 200 to 209200-209
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 210 to 219210-219
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 220 to 229220-229
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 230 to 239230-239
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 240 to 249240-249
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 250 to 259250-259
- Section 6. USING THE RS-232 PORTS TO PROGRAM AND OPERATE THE RFL 9745, pages 260 to 269260-269
- Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 270 to 279270-279
- Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 280 to 289280-289
- Section 7. USING THE 9745 FRONT-PANEL CONTROLS, pages 290 to 297290-297
- Section 8. MAINTENANCE, pages 298 to 306298-306
- Section 8. MAINTENANCE, pages 307 to 315307-315
- Section 9. USING PC APRIL LITE, pages 316 to 325316-325
- Section 9. USING PC APRIL LITE, pages 326 to 335326-335
- Section 10. UCA INTERFACE MODULE, pages 336 to 345336-345
- Section 10. UCA INTERFACE MODULE, pages 346 to 355346-355
- Section 11. GLOSSARY OF TERMS356-369
- Section 12. INDEX370-379
- Section 13. ACCESSORY EQUIPMENT AND SYSTEM DRAWINGS380-394
The file