The text of a manual · part 36 of 43
Instruction Manual RFL 9745 Teleprotection Channel: Section 8. MAINTENANCE, pages 307 to 315
Pages 307 to 315 of 394, from Instruction Manual RFL 9745 Teleprotection Channel
The original document is the PDF (6.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RFL RFL-9745
Page 307
Mother Board
Power Supply
Front Panel module
9745 CHASSIS TOP VIEW (With all modules removed except Mother Board, Front Panel module and Power Supplies)
Audio Communications module
Communications Interface module CPU module Driver module Front Panel module
Communications I/O module
9745 CHASSIS FRONT VIEW (With front cover folded down) Audio or Digital Communications module
SWC I/O module SWC I/O module
Digital Communications module
9745 CHASSIS REAR VIEW
Figure 8-3. RFL 9745 Module Locations
RFL 9745 February 24, 2009
8 - 10
RFL Electronics Inc. (973) 334-3100
Page 308
8.4.3 COMMUNICATIONS MODULE (Audio and Digital Terminals) The Communications Module is mounted at the front of the RFL 9745 chassis, and extends to the rear, where it is attached to a plate along the top of the chassis. To remove the Communications Module, proceed as follows: 1.
On the rear panel, place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the OFF position.
2.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the OFF position.
3.
Open the door on the front of the RFL 9745 by loosening the two thumbscrews that hold it closed, and lowering the door to its open position.
4.
Disconnect any ribbon cables connected to the front edge of the Communications Module.
5.
Disconnect all cables from the connectors on the plate behind the Communications Module.
6.
Disconnect all wires from the terminal blocks on the plate behind the Communications Module. Tag all wires before removing them, if they aren't already labeled. This will simplify reassembly.
7.
Using a cross-blade screwdriver, remove all the screws near the connectors and terminal blocks on the plate behind the Communications Module. Do not remove the screws in the corners of the plate; these hold the plate in position.
8.
Pull the Communications Module out of the front of the chassis.
RFL 9745 February 24, 2009
8 - 11
RFL Electronics Inc. (973) 334-3100
Page 309
To replace a Communications Module, proceed as follows: 1.
Line up the edges of the Communications Module circuit board with the card guides at the top of the chassis.
2.
Slide the Communications Module into the chassis until its rear panel is firmly seated in the chassis.
3.
Using a cross-blade screwdriver, install and tighten the screws near the connectors and terminal blocks on the plate behind the Communications Module to secure the module to the plate.
4.
Using the tags or labels on the wires as a guide, reconnect all wires to the terminal blocks on The plate behind the Communications Module.
5.
Reconnect all cables to the connectors on the plate behind the Communications Module.
6.
Reconnect any ribbon cables to the front edge of the Communications Module.
7.
Close the door on the front of the RFL 9745, and tighten the two thumbscrews to hold it closed.
8.
Raise the front door back into its closed position, and tighten the two quarter-turn fasteners to secure it in place.
9.
On the rear panel, place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the ON position.
10.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the ON position.
8.4.4 SWC I/O MODULES (Audio and Digital Terminals) Each RFL 9745 terminal has two SWC I/O Modules that are mounted at the rear of the chassis and held in place by four captive screws. To remove an SWC I/O Module, proceed as follows: 1.
Place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the OFF position.
2.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the OFF position.
RFL 9745 February 24, 2009
8 - 12
RFL Electronics Inc. (973) 334-3100
Page 310
3.
If the SWC I/O Module to be replaced is equipped with conventional barrier-type terminal blocks, tag all wires leading to its terminal blocks and then disconnect all wires. Tagging the wires will simplify reconnection when the I/O module is replaced.
4.
If the SWC I/O Module to be replaced is equipped with compression-type terminal blocks, pull the quick-disconnect block out of each terminal block.
5.
Using a cross-blade screwdriver, remove the four screws securing the SWC I/O Module in place.
6.
Pull on the SWC I/O Module until it is out of the chassis.
To replace the SWC I/O Module, proceed as follows: 1.
Line up the edges of the SWC I/O Module circuit board with the card guides in the chassis.
2.
Slide the SWC I/O Module into the chassis until it is firmly seated and its rear panel is against the vertical rails at the rear of the chassis.
3.
Using a cross-blade screwdriver, install and tighten the four screws to secure the SWC I/O Module in place.
4.
If the SWC I/O Module to be replaced is equipped with conventional barrier-type terminal blocks, use the tags on the wires as a guide to reconnect all wires to the terminal blocks.
5.
If the SWC I/O Module to be replaced is equipped with compression-type terminal blocks, push the quick-disconnect block back into each terminal block.
6.
Place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the ON position.
7.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the ON position.
8.4.5 COMMUNICATIONS INTERFACE MODULES (Digital Terminal) Each RFL 9745 Digital Terminal has a Communications Interface Module mounted to the top rear of the chassis and held in place with two screws. To remove the Communications Interface Module, proceed as follows: 1.
Place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the OFF position.
2.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the OFF position.
RFL 9745 February 24, 2009
8 - 13
RFL Electronics Inc. (973) 334-3100
Page 311
3.
Remove the connector(s) plugged into the rear of the Communications Interface Module.
4.
Using a cross-blade screwdriver remove the two screws and lockwashers securing the module in place.
5.
Pull on the two knurled thumbscrews at the rear of the module and remove the unit from the chassis.
To replace the Communications Interface Module, proceed as follows: 1.
Line up the edges of the Communications Interface Module circuit board with the grooves at the rear of the 9745 chassis.
2.
Carefully slide the module into the chassis making sure that the connector at the rear of the module circuit board lines up with its mating connector in the chassis.
3.
When firmly seated, install the two screws and lockwashers, and tighten with a cross-blade screwdriver.
4.
Plug in the connector(s) at the rear of the module and tighten any connector retaining screws if applicable.
5.
Place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the ON position.
6.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the ON position.
RFL 9745 February 24, 2009
8 - 14
RFL Electronics Inc. (973) 334-3100
Page 312
CAUTION 1.
Never attempt to remove or replace a fuse with Main or Redundant Power Supply Module energized; component damage may result.
2.
For continued safe operation, always replace a fuse with one having the same voltage and current ratings.
8.5 FUSE REPLACEMENT The RFL 9745's input fuses are located on the circuit board of the Main Power Supply Module. (Dcpowered supplies have two input fuses; ac-powered supplies have one.) There is also a fuse for the power supply module's isolated 10-volt output. If the RFL 9745 is equipped with a redundant power supply, there will also be fuses on the Redundant Power Supply Module. To check the fuses in an RFL 9745 power supply (and replace if necessary), proceed as follows: 1.
On the rear panel, place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the OFF position.
2.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the OFF position.
3.
Open the door on the front of the RFL 9745 by loosening the two quarter-turn fasteners that hold it closed, and lowering the door to its open position.
4.
Loosen the #6 cross slot screw as shown in Figure 8-2.
5.
Pull on the metal ring on the front of the Main Power Supply Module, until the Main Power Supply Module is out of the chassis.
6.
Using a flat-blade screwdriver or a fuse puller, remove the fuse on the Main Power Supply Module from its fuseholder clips and inspect it for damage. If the fuse is bad, it must be replaced. If the fuse is good, check for presence of input voltage at terminal blocks TB1-9 and TB1-10 on the Main Power Supply I/O Module. If voltage is present and the power supply module does not function, the power supply module is defective and must be replaced.
RFL 9745 February 24, 2009
8 - 15
RFL Electronics Inc. (973) 334-3100
Page 313
7.
Insert a fuse with the proper voltage and current ratings into the fuseholder clips, and push down on the fuse until it snaps into place. Power Supply Part Number 105905-1
Voltage Range
Fuse Reference Designation
Fuse Description
Fuse Manufacturer
MFR Part Number
RFL Part Number
19-36 Vdc
F1
Littlefuse
218004
301122
105905
38-150 Vdc
F1
Littlefuse
218002
103389
105930
170-300 Vdc
F1
4A, 250V, slowblow, 5x20mm 2A, 250V, slowblow, 5x20mm 2A, 250V, slowblow, 5x20mm
Littlefuse
218002
103389
8.
Repeat steps 5 and 6 for the other fuses on the Main Power Supply Module.
9.
Line up the edges of the Main Power Supply Module circuit boards with the card guides in the chassis.
10.
Slide the Main Power Supply Module into the chassis until it is firmly seated in its mating connector.
11.
Tighten the #6 cross slot screw on the Main Power Supply as shown in Figure 8-2. NOTE Steps 12 through 19 only have to be performed if your RFL 9745 is equipped with a redundant power supply module. If your RFL 9745 only has one power supply module, go to step 20.
12.
Loosen the #6 cross slot screw on the Redundant Power Supply as shown in Figure 8-2.
13.
Pull on the handle or the metal ring (as applicable) on the front of the Redundant Power Supply Module, until the Redundant Power Supply Module is out of the chassis.
14.
Using a cross-blade screwdriver or a fuse puller, remove each fuse on the Redundant Power Supply Module from its fuseholder clips and inspect it for damage. If the fuse is bad, it must be replaced. If the fuse is good, check for presence of input voltage at terminal blocks TB3-9 and TB3-10 on the Redundant Power Supply I/O Module. If voltage is present and the power supply module does not function, the power supply module is defective and must be replaced.
RFL 9745 February 24, 2009
8 - 16
RFL Electronics Inc. (973) 334-3100
Page 314
15.
Insert a fuse with the proper voltage and current ratings into the fuseholder clips, and push down on the fuse until it snaps into place. See table on previous page for fuse part number.
16.
Repeat steps 11 and 12 for the other fuses on the Redundant Power Supply Module.
17.
Line up the edges of the Redundant Power Supply Module circuit boards with the card guides in the chassis.
18.
Slide the Redundant Power Supply Module into the chassis until it is firmly seated in its mating connector.
19.
Tighten the #6 cross slot screw on the Redundant Power Supply as shown in Figure 8-2.
20.
On the rear panel, place the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module in the ON position.
21.
If the RFL 9745 is equipped with a redundant power supply, place the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module in the ON position.
22.
Look at the indicator on the front of the Main Power Supply Module. If the indicator on the front of the Main Power Supply Module lights, the module s working properly. If it does not light or if one or more fuses blow again, the module is defective and must be replaced.
23.
If the RFL 9745 is equipped with a redundant power supply, look at the indicator on the front of the Redundant Power Supply Module. If the indicator on the front of the Redundant Power Supply Module lights, the module is working properly. If it does not light or if one or more fuses blow again, the module is defective and must be replaced.
24.
Once the power supply indicator is lit, raise the front door back into its closed position, and tighten the two screws to secure it in place.
RFL 9745 February 24, 2009
8 - 17
RFL Electronics Inc. (973) 334-3100
Page 315
8.6 HOW TO ARRANGE FOR SERVICING If necessary, RFL 9745 Modules and I/O Modules may be returned to RFL for repair. Contact our Customer Service Department using the telephone number listed at the bottom of this page. You will be given a return material authorization (RMA) number and shipping instructions.
RFL 9745 February 24, 2009
8 - 18
RFL Electronics Inc. (973) 334-3100