Page 45

Center Frequency 2210Hz

Block zone

Block zone

Block zone

2060Hz (Guard)

2360Hz (Trip)

Discriminator output voltage

Figure 2-11. Frequency discriminator output voltage

In the 9745 one of the audio tone settings is “FM noise” this setting is entered as a percent. This is a concept which on the surface is difficult to grasp although once explained is simple to understand. Because the primary function of the 9745 is to send trip and guard information as opposed to high speed data. By application the system is predominately receiving a guard frequency and shifts to the trip frequency only when required. With this understanding FM noise percent is the percent of frequency discriminator output voltage change from DSP sample to sample. Although DSP operates very similar to older discrete analog tone circuits, it is a digital circuit. The sampling rate at which the DSP calculates its output is 8 KHz. The discriminator output voltage is plotted at this rate. For the frequencies selected for this example the recommended FM Noise % is 30. This means that an FM Noise condition is declared when the discriminator output voltage changes greater than 30% between samples. When a system shifts from a Guard frequency to a Trip Frequency this will cause an FM Noise output for about one sample period, however this condition does not last long enough to effect the overall system performance.

RFL 9745 February 10, 2009

2 -11

RFL Electronics Inc. (973) 334-3100

Page 46

2.2.4 DIGITAL COMMUNICATIONS MODULE 2.2.4.1 GENERAL INFORMATION The Digital Communications Module interfaces the RFL 9745 to digital circuits. It contains a Digital Communications Board and a Communications I/F Board. The Digital Communications Board contains a single digital channel with an embedded 80C196 processor. Interfaces to any one of eight I/O boards are controlled by 3 programmable logic controllers. These are programmed to recognize which I/O board is plugged into the Digital Communications Board. The Digital Communications Board also contains digital interface circuits, circuits required to provide two isolated RS-232 ports into the CPU, and a PLL (phase locked loop) to recover the clock when the Co-Directional G.703 or Fiber Optics boards are used. The Communications I/F Board performs two functions. First, it acts as an interface between the CPU and the 80C196 on the Digital Communications Board. Second, it acts as an IRIG-B receiver. IRIG-B is a form of code that is used by satellite time receivers to transmit the exact time to other devices. By having an IRIG-B receiver, the RFL 9745 can tag events with a standard time. The Communications I/F Board uses an Intel 80C52 single chip microcontroller to perform its functions.

2.2.4.2 THEORY OF OPERATION The Digital Communications Module connects the RFL 9745 to digital communications media. This module contains the digital communications board and the same communications interface board that is used on the RFL 9745 audio tone unit. The 9745 digital communication is in the form of a 15 bit binary message which repeats continuously at the rate of 64 Kb/s (kilobits/second). At this rate the message repeats approximately once every 234 microseconds. The 15 bit message is made up of one sync bit which alternates with every message, 8 data bits, and 6 CRC (cyclic redundancy check) code bits, as shown in Figure 2-12.

bit #

14

13

12

11 sync bit

10

9

8

7

8 data bits

6

5

4

3

2

1

0

CRC code bits

Figure 2-12. 15 bit digital message

RFL 9745 February 10, 2009

2 -12

RFL Electronics Inc. (973) 334-3100

Page 47

The 8 data bits make up an 8 bit data word which can be either a command word or a modem word, depending the value of bit 13 of the data message. Modem words are sent only when required. When bit 13 of the message is “0”, the data word is a command word which carries the trip or guard information. Bits 6 through 12 of the command word are function bits F1 through F7. When a function bit is low, it represents a guard state; when a function bit is high, it represents a trip state. To avoid consecutive “low” data bit transmission, the message is “XOR’ed” with a Hex 55 to form the final message. See Figure 2-13 for the format of the command word.

bit #

13

12

11

10

9

8

7

6

0

F7

F6

F5

F4

F3

F2

F1

Function Bits

Figure 2-13. Format of command word

When bit 13 of the message is “1”, the data word is a modem word which carries the ASCII information requested through the RS232 port for remote status or diagnostic operations. If bits 13,12,11 and 10 are “1001”, then bits 9,8,7 and 6 of the modem word are the lower 4 bits (or low nibble) of the modem data. If bits 13,12,11 and 10 are “1010”, then bits 9,8,7 and 6 of the modem word are the higher 4 bits (or high nibble) of the modem data. The 8 modem data bits M0 through M7 are sent 4 bits at a time, first (M0 - M3) and then (M4 - M7). Therefore it takes two consecutive 15 bit data messages to send eight bits of modem data. See Figure 2-14 for the format of the modem word.

bit #

13

12

11

10

9

8

7

6 Lower 4 bits of modem data

1 1

0 0

0 1

1 0

(M3 (M7

M2 M6

M1 M5

M0) - Low Nibble M4) - High Nibble

Modem Data Bits

Higher 4 bits of modem data

Figure 2-14. Format of modem word

RFL 9745 February 10, 2009

2 -13

RFL Electronics Inc. (973) 334-3100

Page 48

The 15 bit message is constantly transmitted from one circuit-end Equipment to the opposite circuitend Equipment. A trip command is accepted by the Equipment if two consecutive trip messages are received. If a message fails the CRC tests, it is discarded and one CRC failure is counted. When a predefined count is reached, a “Data Error” is generated. It will be reset when an additional 30 consecutive correct CRC messages are received. In addition to the CRC checks, clock errors are also monitored against pre-selected levels to provide squelching and alarming as well. Two of the functions of the digital communications module are the same as the audio tone version. The RS232 remote interrogation port is unchanged from the audio version. It provides a link from an external asychronous serial device to the CPU of the 9745. The digital communications module provides for level conversion and isolation of the RS232 signal. The IRIG-B input path is also provided by the digital communications module. An AM modulated signal is demodulated and interpreted by the communications interface processor. This is unchanged from the audio version. The main function of the digital communications module is to provide a synchronous serial path from the 9745 bus to the input/output module. Depending on the input/output module installed many different media can be supported, such as fiber, RS449 or G.703. The same digital communications module is used for all input/output modules. The operation of the digital communications module is as follows. A byte containing seven function bits is received from the CPU. The byte of data has a 6 bit CRC code added to it and is followed by a sync bit. This forms a 15 bit message. The polarity of the sync bit alternates with every message. The CRC code is generated through the use of a look up table stored in ROM. This data is placed in a shift register and shifted out by the transmit clock. In an RS449, Short Haul Fiber, or G.703 Contra-directional system the transmit clock comes from the SIO module and to there from the communications media. The SIO makes level adjustments and performs loopback connections if desired. At the receiving end the reverse happens. The CRC code is checked against the lookup table and if no errors are found it is passed on to the CPU. The operation of the transmit clock in the G.703 Co-directional and long haul fiber optics unit is more complex. With either scheme the 64 Kb/s transmit clock is generated by the 9745 and is encoded with the data into a data stream which is actually 256 Kb/s. The data stream is then either level adjusted for G.703 or converted to an optical signal for fiber transmission. At the receiving station the signal is level and media corrected and then the clock is recovered by a 256 kHz PLL. From that point it is treated as above. When using G.703 Co-directional, if J1 is inserted the module will generate octet timing, and the external equipment can be strapped to accept octet timing. The processor on the module receives set up information from the CPU and checks for clock errors, frame errors and data errors. This is all passed to the CPU via the bus.

RFL 9745 February 10, 2009

2 -14

RFL Electronics Inc. (973) 334-3100

Page 49

2.2.5 DIGITAL INTERFACE MODULES Each RFL 9745 can be configured with one of eleven different types of digital interface modules. Five of these are Serial Input/Output (SIO) modules which are listed in Table 2-2, and six of these are Fiber Input/Output (FIO) modules which are listed in Table 2-3. Each of these modules plugs directly into the upper rear panel of the RFL 9745. See section 3 of this manual for detailed installation instructions and wiring information. Table 2-2. Characteristics of Serial Input/Output modules

Model Designation

Part Number

Data Rate

RS-449 SIO G.703 Contra-Directional SIO X.21 SIO G.703 Co-Directional SIO with programmable octet timing E1 Serial Interface Adapter

105065-1 105065-2 105065-10 105065-11

56/64 Kbps 64 Kbps 64 Kbps 64 Kbps

107320

2.048 Mbps

Rear Panel D-subminiature Connector 37 pin male 25 pin male 15 pin male 15 pin male 15 pin male and 2 BNC connectors

Table 2-3. Characteristics of Fiber Input/Output modules

Model Designation

Part Number

Wavelength

Fiber Type

Light Source

Short Haul FIO 850 NM MM LED FIO 1300 NM MM LED FIO 1300 NM SM LED FIO 1300 NM SM LAS FIO 1550 NM SM LAS FIO

107310 105065-5 105065-6 105065-7 105065-8 105065-9

850 nm 850 nm 1300 nm 1300 nm 1300 nm 1550 nm

Multimode Multimode Multimode Singlemode Singlemode Singlemode

LED LED LED LED Laser Laser

Fiber Connector Type ST ST ST ST ST ST

2.2.6 FIBER SERVICE UNIT The function of the Fiber Service Unit (107460-x) is to provide the RFL 9745 with a remote port using dual fiber cables. The remote port can be RS-449, G.703, V.35 or X.21. The Fiber Service Unit can be located up to 2km away from an RFL 9745 equipped with a Short Haul Fiber I/O module (107310). Refer to the Fiber Service Unit Instruction Data sheet (publication number: ID C37.94FSU) for more information..

RFL 9745 February 10, 2009

2 -15

RFL Electronics Inc. (973) 334-3100

Page 50

2.2.7 SWC I/O MODULES The SWC I/O Modules convert the high-voltage, high-current signals received from external equipment to logic-level inputs that can be processed by the RFL 9745. They also provide high-voltage output contacts to interface the RFL 9745 to external equipment. There are three different SWC I/O Modules: a Solid-State I/O Module, a Solid-State/Relay I/O Module and a High Speed Relay I/O Module. One or two boards can be installed in a chassis. All signals to and from the SWC I/O Modules originate on the Driver Module.

Solid-State I/O Module

The Solid-State I/O Module provides four solid-state outputs, three low current relay contacts, and four inputs.

Solid-State/Relay I/O Module

The Solid-State/Relay I/O Module provides one solid-state output, three high current relay contacts, three low current relay contacts, and four inputs.

High Speed Relay I/O Module

The High Speed Relay I/O Module provides four high current relay contacts, four low current relay contacts, and four inputs.

Each output on the SWC I/O module contains a circuit to sense the condition of the output circuit. This forms an input to the logic table which can be used to cause an alarm if so desired. The solid state outputs are sensed to determine if more than 150 ma is flowing through the contacts. If the system has closed the output and not more than 150 ma is sensed, then an FTT (Fail To Trip) input is raised to the alarm logic. If the system has not closed the output and more than 150 ma is sensed, then an Output Short input is raised to the alarm logic. Note that the 150 ma threshold is suitable only for high current devices such as lockout relays and trip coils. Interposing relays and solid state inputs will not usually draw sufficient current to detect. In these cases either the FTT input should not be used in the alarm logic or a shunt resistor can be used to increase the current drawn. The trip relay outputs are sensed to determine if the relay coil is receiving current. Due to the higher current ratings the actual trip current is not measured.

2.2.8 FRONT PANEL MODULE The Front Panel Module contains an LCD display that reports various system conditions. It has eight pushbutton switches to call up information for display. LED indicators report the status of the transmitted and received functions. An RS-232 connector is also available on the front panel.

RFL 9745 February 10, 2009

2 -16

RFL Electronics Inc. (973) 334-3100

Page 51

2.2.9 POWER SUPPLY MODULE The Power Supply Module converts the station battery voltages to the levels required by the RFL 9745. It uses a flyback switching topology, with an efficiency of 70 percent. The Power Supply Module is configured for redundant operation. It also has an undervoltage monitor for alarm purposes.

2.2.10 STATUS OUTPUT MODULE (optional) The Status Output Module is housed in an extension to the bottom of the RFL 9745 chassis. It supplies six additional solid-state annunciator outputs when required. The Status Output Module is attached to and driven by the Driver Module.

2.2.11 GEC TYPE PRECISION RELAYS (optional) As an option, one or two GEC Type precision relays can be added to the RFL 9745. Each relay is chassis mounted at the rear of the power supply module and is wired to the existing power supply terminal block on the rear panel. This allows for access to the coil leads and up to three pairs of contacts. If your RFL 9745 has this relay option, a product information sheet for the relay will be included in section 12 of this manual. A wiring diagram of the relay contacts and how it interfaces with the RFL 9745 is shown in Figure 12-1.

2.2.12 60HZ FILTERS AND HYBRID (optional) In some applications, the 9745 system is required to operate with a 40 volt rms 50/60 Hz signal on the audio line terminals. This signal must be attenuated before reaching the Audio Communications board to avoid overdriving the isolation transformer and various input circuits. A 600 Hz high pass filter is added, when needed, to attenuate the 50/60 Hz signal by more than 48 dB on all 4-wire circuits. For 2wire applications, a hybrid is also included in the 9745 Power I/O module along with the filter. Additional filtering is also done on the Audio Communications board for frequencies below 300 Hz. Filters and Hybrid: Frequency Response and Rejection Characteristics. Filter Modules: Frequency Response: Narrowband: +/-0.5 dB from 600 to 3400 Hz. Wideband: +/-0.5 dB from 600 to 4000 Hz. Rejection: >48 dB at 60 Hz or greater. Filter/Hybrid Module: Frequency Response: Narrowband: +/-0.5 dB from 600 to 3400 Hz. Wideband: +/-0.5 dB from 600 to 4000 Hz. Rejection: >48 dB at 60 Hz or greater. Trans-hybrid loss: Narrowband: >25 dB from 600 to 3400 Hz. Wideband: >25 dB from 600 to 4000 Hz. RFL 9745 February 10, 2009

2 -17

RFL Electronics Inc. (973) 334-3100

Page 52

2.2.12.1 QUAD FILTER MODULE (optional) The quad filter I/O module contains filters for all four ports on the Audio Communications board. The filters are third order 600 Hz high pass LC designs using 26mm pot cores for the inductors. These inductors can handle the 50/60 Hz input signals without producing any distortion products. All four filters are identical. The signal lines on the rear panel terminal block (pins 1-8) are connected to one side of the filters. A wire cable connects the other side of the filters to TB1 on the Audio Communications Board. The channel frequencies are limited to the 600 to 3400 Hz range in these applications. Frequencies below 600 Hz can still contain a fairly high level of 50/60 Hz harmonics appearing on the input line along with the fundamental frequency. These could interfere with channel signals in this band if they were used. See Figure 12-2 for wiring information.

2.2.12.2 DUAL FILTER MODULE (optional) The dual filter I/O module contains only two filters for use with a single channel 4-wire system. The filters are identical to those in the quad filter I/O module. See Figure 13-3 for wiring information.

2.2.12.3 FILTER/HYBRID MODULE (optional) The two-wire filter hybrid I/O module is used for a single channel 2-wire application. The 50/60 Hz interference signal is attenuated by the same 600 Hz high pass filter that is used on the other modules. The line side of the filter is connected to pins 1 and 2 of the rear panel terminal block. The other side of the filter drives a hybrid transformer. The hybrid transformer consists of a transformer and a balancing network. This network represents a portion of the impedance seen by the line side of the hybrid transformer, and is required to maintain balance at all operating frequencies. A cable connects the equipment side of the hybrid to 4-wire transmit and receive ports on the Audio Communications board. See Figure 13-4 for wiring information.

RFL 9745 February 10, 2009

2 -18

RFL Electronics Inc. (973) 334-3100

Page 53

2.3 SYSTEM OPERATION (AUDIO-TONE UNITS ONLY) While the hardware inputs and outputs have been detailed above, little comment has been made about how the system processes the inputs to generate outputs. The resident software is in place to present the inputs to a Logic Table. The Primitive Processor uses this Logic Table to produce outputs based on the inputs. These outputs are then used to trigger the RFL 9745's hardware outputs. The inputs, outputs, and tone transceivers can be tied together and controlled in any desired manner. The I/O and tone transceivers are chosen for their suitability for creating an audio teleprotection channel. The Logic Table makes the RFL 9745 into what is required by the customer. The default Logic Table included in the RFL 9745 causes the unit to act as a teleprotection channel. A different Logic Table would be required for applications other than teleprotection. There are two default logic tables included in the embedded code of the 9745. These are the 9745 and the 6750 default logic tables. The 6750 default logic table provides a dual tone functionality compatible with an RFL 6750. If requested by the customer there will be custom logic tables provided with the PC_APRIL disk (see section 9). There may also be custom logic tables preloaded into the system for a specific application. The alarm default provides generic audio and hardware alarms. An example of typical system operation is as follows. In this example, an input is applied to Input 1A of the local RFL 9745. Its Logic Table shifts Tone 1 to its high state if Input 1A is active. A remote RFL 9745 receives the high tone. The remote's Logic Table directs the remote RFL 9745 to close Output 1A if Transceiver #1 receives a high tone. The following steps produce this result, as shown on Figures 2-15 and 2-16. Expected results or comments are indented and appear in boldface type. 1.

At the local RFL 9745, a voltage is applied to Input 1A (SWC I/O Module A Input 1).

2.

A signal is relayed to the driver processor that Input 1A is active.

3.

The Driver processor sends a message to the CPU that Input 1A is active.

4.

The 68000 receives this message and tells the TMS320C25 that Input 1A is active.

5.

The TMS320C25 processes the Logic Table using this new input value. For the purposes of this example, this input should cause the tone to shift.

6.

The 68000 reads the results of the Logic Table from the TMS320C25. The results have Tone 1 shifted up in frequency.

7.

The 68000 sends a message to the Communications I/F to shift Tone 1 up.

RFL 9745 February 10, 2009

2 -19

RFL Electronics Inc. (973) 334-3100

Page 54

Figure 2-15. Example of typical system operation in the local RFL 9745 terminal

FLASH

RAM 32K X 8

SWITCHES 8

LAMPS 9 LED

LCD DISPLAY 2 X 16 CHAR

RS232 PORT

FRONT PANEL BRD

CAPACITOR

REAL TIME CLOCK

BUS CONTROL

RAM 32K X 16

5 TMS320C25 25 MHZ

2 DRIVERS

SUPPRESSION COMPONENTS

BUS I/O 8052

BUS INTERFACE

STATUS OPTION BOARD

SOLID STATE OUTPUTS 6 FORM A

PROGRAM RAM 32K X 16 I/O REGISTERS + ARBITRATION

DUART

DRIVER BOARD

DRIVE LOGIC

EPROM 2K X 8

INTERRUPT CONTROLLER

FAST BUS

4 128K X 16

SLOW BUS

6

PROC 68K 12.5 MHZ

WATCH DOG

3

7

ISOLATION RS232 PORTS

INTERFACE

BUS

COMMS I/F

SOLID STATE OUTPUTS 4 FORM A

OPTICAL INPUTS 4

ALARMS RELAYS 3 FORM C

SOLID STATE OUTPUTS 4 FORM A

OPTICAL INPUTS 4

ALARMS RELAYS 3 FORM C

IRIG-B RECEIVER

8052

1

DSP TMS32OC50

DSP TMS32OC50

SWC I/O BOARD

SUPPRESSION COMPONENTS

SUPPRESSION COMPONENTS

SUPPRESSION COMPONENTS

SWC I/O BOARD

SUPPRESSION COMPONENTS

SUPPRESSION COMPONENTS

SUPPRESSION COMPONENTS

8

DIGITAL SIGNAL PROCESSORS

AUDIO COMMS

TERMINAL BLOCK

CPU BOARD

TERMINAL BLOCK

2 -20

TERMINAL BLOCK

RFL 9745 February 10, 2009

RFL Electronics Inc. (973) 334-3100

AUDIO CIRCUITS

RS232

IRIG-B

AUDIO LINES

9

AUDIO TRANSFORMERS