The text of a manual · part 41 of 43
Instruction Manual RFL 9745 Teleprotection Channel: Section 11. GLOSSARY OF TERMS
Pages 356 to 369 of 394, from Instruction Manual RFL 9745 Teleprotection Channel
The original document is the PDF (6.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RFL RFL-9745
Page 356
Section 11. GLOSSARY OF TERMS 10 Base-T
An ethernet local area network which works on twisted pair cable.
10 Base-FL
An ethernet local area network which works on a fiber link.
Address
A unique designation assigned to each RFL 9745 terminal. Addresses are used to identify RFL 9745 terminals during tests.
Adjacent Channel Rejection
An indication of channel separation. For example, the RFL 9745 is rated for an adjacent channel rejection of 40 dB. If the inchannel signal is at –40 dBm, a 0-dBm signal on an adjacent channel will not cause interference.
Alarm Logic Table
A list of logic decisions made by the RFL 9745 to produce its alarm outputs. It is set at the factory according to the default logic diagram supplied with the equipment. (See Section 2 for more information.)
Alarms Display
A display screen that shows the current status of all RFL 9745 alarms.
AM Noise
Unwanted amplitude modulations on a communications channel, usually caused by static, atmospheric conditions, or similar causes.
Amplitude Stability
An indication of how much the transmit level can be expected to vary due to temperature variations, input voltage variations, and other factors.
AND Gate
A logic primitive with two inputs and one output. If both inputs are true, the output is true. If either input is false, the output is false.
Annunciator Output
An output that can be programmed to indicate an alarm condition has occurred. Each annunciator output is a set of relay contacts that can drive external equipment.
APRIL
An acronym for Asynchronous Programming and Remote Interrogation Language. This is the language used by the RFL 9745 to communicate with a PC or terminal through its RS-232 ports.
Attack
A timer parameter that controls how long it will take the timer's output to go true after its input goes true.
RFL 9745 December 22, 2006
11 - 1
RFL Electronics Inc. (973) 334-3100
Page 357
Auto Test
An RFL 9745 test that is automatically initiated at set intervals.
Autotest Complete
The “Autotest Complete” parameter can be either Active or Inactive. It is set inactive upon bootup or when there is an outage, as defined in the alarm logic. It is set active at the completion of any attempt to run an Autotest, whether or not the test finished or ran successfully. Once active, it stays active until the next bootup or outage.
Autotest Timeout
The “Autotest Timeout” parameter can be either active or inactive. It is set active when an autotest fails to complete within a specified time. This could be caused by a misconnection or degraded communication between 9745s. When it is set inactive, the autotest completed, whether or not it passed. For example, if an address test has been run, and the wrong address returned, the “Autotest Timeout” parameter will be set to inactive, even though the “Address Test Fail” parameter is active.
Bandwidth
The distance between 3-dB points for a channel; signals outside the bandwidth will be attenuated.
Baud Rate
An indication of how fast data can be sent through the RFL 9745's RS-232 port. Five different settings are possible in the RFL 9745: 300 baud, 1200 baud, 2400 baud, and 9600 baud and 19,200.
BER
Abbreviation for "bit error rate," is the ratio of error bits to transmitted bits in a digital communication system.
Blocking
Directional Comparison Relaying System, utilizing communications, primarily on/off powerline carrier, to prevent circuit breaker tripping for faults located external to the protected line.
Boost
An RFL 9745 operating feature that forces the transmit level to increase by a set amount for a specified time interval when the output shifts to its trip frequency. Also called "Trip Boost."
Boost Timer
A timer that keys the transmitter to increase by a set amount for a specified time interval when the output shifts to its trip frequency.
Bus
A data path shared by several devices or modules, such as an address bus or data bus.
Bus Error
An error that has occurred involving one of the RFL 9745's buses.
RFL 9745 December 22, 2006
11 - 2
RFL Electronics Inc. (973) 334-3100
Page 358
CCITT
Abbreviation for Consultative Committee for International Telegraph and Telephone.
CCITT G.703
CCITT Recommendation for the physical and electrical characteristics of hierarchical digital interfaces.
Center Frequency
The nominal output frequency for an FSK channel; frequencies will be shifted above and below this frequency in equal amounts (+30 Hz, +60 Hz, etc).
Channel
A path for transmission between two RFL 9745 terminals; may be a telephone line, a fiber optic cable, or a direct digital link.
Channel Propagation Delay
The amount of time it takes a signal to pass from one terminal to another.
Channel Setup
The act of setting the RFL 9745's programmable parameters for the customer's requested configuration. This is usually done at the factory, but it can also be done by using the information on Section 5 of this manual.
Channel Spacing
The amount of separation between the center frequencies of adjacent channels. For example, three channels with center frequencies of 1500 Hz, 1620 Hz, and 1740 Hz have a channel spacing of 120 Hz.
Checkback Testing
A testing method where a test signal is sent from one terminal to another. The receiving terminal sends the signal back to the transmitting terminal. If the received signal matches the transmitted signal, the checkback test is successful.
Clear To Send (CTS)
An RS-232 signal; indicates the DTE may begin transmitting.
Command Extend Timer
A timer that keeps a command output high for a specific interval, even if the command input ceases to exist.
CPU
Abbreviation for Central Processing Unit.
CPU Error
An error that has occurred involving the Central Processing Unit.
CRC
Abbreviation for Cyclic Redundancy Check, which is a code used to guarantee the accuracy of the 15-bit digital word.
Cumulative Outage
A display of the total amount of outage time (in seconds) since the last time the RFL 9745 was reset.
RFL 9745 December 22, 2006
11 - 3
RFL Electronics Inc. (973) 334-3100
Page 359
Data Bit
A logic one or zero; the smallest unit of information. In the RFL 9745, eight data bits are in each data word.
Data Rate
An indication of how fast the RFL 9745 can send signals, expressed in bits per second (bps).
Data Terminal Ready (DTR)
An RS-232 signal; indicates the DTE is ready for data transmission.
DB-25
A 25-pin D-subminiature connector.
DB-9
A 9-pin D-subminiature connector.
DCE
Data Communications Equipment
Decay
A timer parameter that controls how long the timer's output will remain true after its input goes false.
Default Logic
The logic decisions stated in the logic tables when the RFL 9745 left the factory. Can be used to return the RFL 9745 to its factorydefault configuration.
Dependability
A measure of the ability of communications equipment to output valid trip signals in the presence of channel interference.
DHCP
Dynamic Host Configuration Protocol
Direct Transfer Trip (DTT)
The ability of a communications receiver to trip a circuit breaker directly and without the suipervision of a protective relay.
Directory Of Events
See "Event Log."
DNA Index
Digital Network Architecture Index
DTE
Data Terminal Equipment
Dumb Terminal
A serial ASCII terminal as opposed to a PC with terminal emulation software.
Dynamic Range
See "Receiver Dynamic Range."
Event Log
A register that keeps a running tally of the number of times each function, input, output, and alarm is active. This information can be used to analyze system performance.
RFL 9745 December 22, 2006
11 - 4
RFL Electronics Inc. (973) 334-3100
Page 360
Failure Detector
A circuit that constantly monitors a trip output circuit for misoperation. If a misoperation is detected, it will trigger an alarm.
Failure To Trip
An alarm condition created when the logic indicates that a trip output should be active, but less than 150 ma is sensed through the contacts.
FIO
Abbreviation for Fiber Input/Output.
Flash Timer
A timer that keys the transmitter to rapidly switch between trip and guard frequencies when a valid trip input is received.
Flow Control
A method of controlling the transfer of data from one terminal to another to prevent loss of data when the receiving device's buffer is almost filled.
FM Noise
Unwanted frequency modulations on a communications channel, usually caused by static, atmospheric conditions, or similar causes.
Frequency Shift Keying (FSK)
A modulation technique in which one frequency indicates guard, and another frequency indicates trip.
FUNCTION Indicators
A group of eight LED indicators on the RFL 9745's front panel that show the status of the four tone channels. These indicators are normally programmed to light when a trip frequency is being transmitted or received.
GOOSE
Generic Object Oriented Substation Event
Guard
A tone or signal that is produced whenever the system is functioning normally (no trips, no active alarms).
Handshaking
A protocol used by RS-232 devices to establish connections. The RFL 9745 uses "XON/XOFF" handshaking, which is also called "software handshaking."
High Signal
An alarm condition created when an incoming tone is above a preset limit.
HTML
Hypertext Markup Language
IED
Intelligent Electronic Device
RFL 9745 December 22, 2006
11 - 5
RFL Electronics Inc. (973) 334-3100
Page 361
I/O Menu
A menu that lists information about the current status of each RFL 9745 input, output, and annunciator output. Viewed by pressing front-panel I/O switch.
I/O Module
An RFL 9745 subassembly that is installed at the rear of the chassis and has connectors or terminal blocks for making connections to external equipment.
IP Address
Internet Protocol Address
IRIG-B
A standard time code developed by the Inter-Range Instrumentation Group (IRIG) , Format B, is utilized in the RFL 9745.
Jitter
A tendency towards the lack of synchronization of digital pulses over a transmission medium.
Kbps
An abbreviation for "1,000 bits per second."
LAN
Local Area Network
Last Reset Date
The time and date that the system was last reset.
Latch
A logic primitive with two inputs (SET and RESET) and one output. If the SET input goes true, the output goes true unless the RESET input is false.
Leased Line
A telephone line reserved for the exclusive use of a leasing customer, with no inter-exchange switching arrangements. Leasedlines may be point-to-point or multipoint.
LEVELS Menu
A menu that lists information about transmit and receive levels, and channel delay measurements. Viewed by pressing front-panel LEVELS switch.
Lock-Out
A mode the RFL 9745 enters if the wrong password is entered after three tries. This mode will last about five minutes. During lock-out no one will be able to enter the mode that triggered the lock-out.
LOG Menu
A menu that lists information about how many times each significant vent in RFL 9745 operation has occurred since the last system reset. Viewed by pressing front-panel LOG switch.
Logic Programming
An RFL 9745 mode during which the RFL 9745's logic table can be tailored to suit a specific application.
RFL 9745 December 22, 2006
11 - 6
RFL Electronics Inc. (973) 334-3100
Page 362
Logic Table
See "Alarm Logic Table" and "Primitive Logic Table."
Low Signal
An alarm condition created when an incoming tone is below a preset limit.
MAC
Medium Access Control
Main Menu
A list of APRIL commands or parameters that allows an operator to enter any of the RFL 9745's operating modes.
Menu
A list of commands or parameters that will appear on a terminal or PC screen when communicating with the RFL 9745 using APRIL.
Microwave
A general term used to describe high-frequency point-to-point radio communications. For utility applications, microwave generally operates between 2 GHz and 23 Ghz.
Modem
An abbreviation for "modulator/demodulator;" a device that converts serial digital data into an audio signal for transmission over telephone lines, and converts incoming audio signals back into digital data.
Module
An RFL 9745 subassembly that is installed behind the door at the front of the chassis, or plugs into the rear of the chassis.
Next Auto Test
The amount of time until the next scheduled test will occur.
Node
Connection point (Gate) in a logic table, a node is “driven” by a gate or operator. A logic table has as many nodes as it has lines.
Non-Volatile Storage
Memory devices that are equipped with back-up batteries to retain data in the event of a power failure.
Noise
Unwanted signals on a communications channel, usually caused by static, atmospheric conditions, or similar causes.
NOT Gate
A logic primitive with one input and one output. The output is always the opposite of the input.
NOP Gate
Non operational gate, no inputs or outputs.
NSAP Address
Network Service Access Point Address
Operate Time:
The time from the receipt of a command input to the response of a solid-state output, less any channel propagation time.
RFL 9745 December 22, 2006
11 - 7
RFL Electronics Inc. (973) 334-3100
Page 363
Optic Power Budget
The nominal output level produced by the fiber optic module in fiber optic RFL 9745 terminals. For reliable operation, all the losses in the fiber optic line (such as coupling splicing losses, exit losses and fiber attenuation) must not exceed this value.
OR Gate
A logic primitive with two inputs and one output. If both inputs are false, the output is false. If either input is true, the output is true.
Outage
Is defined by the user in the Alarm Logic as a combination of alarm conditions.
Outage Timer Active
The “Outage Timer Active” parameter can be active or inactive depending on how the logic is programmed. The outage timer is a clock which starts when there is an “outage” condition and stops when the “outage” condition clears. The clock increments are: days, hours, minutes, seconds, and milliseconds. An “outage” condition is defined by how the logic table is configured. If a logic table does not have an outage output, the “Outage Timer Active” parameter will always be inactive. It is active if the “outage” logic output is active. This requires programming the alarm logic to include “outage” as one of its outputs. Refer to Figure 2-7 “9745 Audio Default Alarm Logic Diagram” for more information.
Output Short
An alarm condition created when the logic indicates that a trip output should be open, but a current greater than 150 mA is being sensed through its contacts.
Parity
Additional bits added to a data word to permit detection of single errors. (The RFL 9745 does not use parity bits.)
Password
A character string that must be entered before the RFL 9745 will grant a user access to a particular operating mode or menu display.
Permissive Transfer Trip (PTT)
The communications receiver trip output and the operation of a protective relay are both required to trip a circuit breaker.
Ping-Pong
A test that measures channel delay by sending a signal and timing how long it takes to receive it back.
PLL
Abbreviation for Phase Locked Loop.
Powerline Carrier
A communication technique in which a protection signal is injected onto the powerline that it is protecting. The line itself serves as the communications medium.
RFL 9745 December 22, 2006
11 - 8
RFL Electronics Inc. (973) 334-3100
Page 364
Pre-Trip Timer
A timer that requires a trip input to be received for a specific time period before it is accepted as valid. The pre-trip timer functions as a protection against noise-induced false trips.
Primitive Logic Table
A list of logic decisions made by the RFL 9745. It is set at the factory according to the default logic diagram supplied with the equipment. (See Section 2 for more information.)
Primitives
The basic building blocks that form the RFL 9745's logic table; gates, timers, and latches. (See Section 2 for more information.)
Private Network
A user-owned telephone system, such as the PABX systems used to connect the telephone extensions at many companies.
Programming Mode
An RFL 9745 mode during which parameter settings can be viewed and changed as required.
PROM
An abbreviation for "Programmable Read-Only Memory."
Rack Unit (RU)
A unit of vertical rack space, equal to 1.75 inches (4.4 cm). (The RFL 9745 is 5.25 inches high (13.3 cm); this equals 3 rack units.)
Radio
A general term used to describe low-frequency point-to-point radio communications. For utility applications, radio generally operates between 400 MHz and 1 GHz.
Read Settings
An RFL 9745 mode during which parameter settings can be viewed but not changed.
Receive Channel Delay
The amount of time it takes a receive signal to pass from one RFL 9745 to another; usually half the channel round trip delay, assuming the transmit and receive delays are equal.
Receiver
An RFL 9745 terminal that is configured to receive but not transmit.
Receiver Dynamic Range
The difference between the lowest and highest input signals that the receiver can accept.
Receiver Sensitivity
The lowest input signal that the receiver can accept and reliably produce valid outputs.
Redundant Power Supply
A second power supply module that is installed in the RFL 9745 to supply power in the event the main power supply fails.
Relay Output
An output that is provided by a set of dry relay contacts.
RFL 9745 December 22, 2006
11 - 9
RFL Electronics Inc. (973) 334-3100
Page 365
Request To Send (RTS)
An RS-232 signal; indicates that the DTE has data to transmit.
ROM
Abbreviation for Read Only Memory.
RS-232
An EIA standard commonly used to connect data processing devices. DB-25 connectors are usually used for making connections, but DE-9 connectors may also be used. RS-232 is functionally identical to CCITT V.24/V.28.
RS-422
An EIA standard for cable lengths that extends the 50-foot limit imposed by RS-232.
RS-449
An EIA standard for connectors; a companion standard to RS422.
Security
A measure of the ability of communications equipment to prevent false trip outputs during the presence of channel interference.
Sequence-Of-Events Log
A register that contains information about system events such as trip inputs and alarm outputs. This information is stored in the order the events occurred, and can be used to analyze system performance.
Signal-To-Noise Ratio (S/N Ratio) An indication of signal quality derived from the signal level divided by the amount of noise on the line. CIrcuits with high S/N ratio result in better communications than those with low S/N ratios. SIO
Abbreviation for Serial Input/Output.
Solid-State Output
An output that is provided by an open-collector transistor or a solid-state output module.
Spurious Output
Unwanted frequencies on the communications medium that are by-products of the frequency of interest (such as harmonics).
Squelch
An RFL 9745 function that quiets the tone outputs when no input is being received.
STATUS Menu
A menu that lists information about the RFL 9745's four communications channels and alarm outputs. Viewed by pressing front-panel STATUS switch.
Stop Bit
A data bit that indicates the end of a data word. In the RFL 9745, each data word contains one stop bit.
RFL 9745 December 22, 2006
11 - 10
RFL Electronics Inc. (973) 334-3100
Page 366
Superuser Password
A character string that can be entered to gain access to any operating mode or menu display that requires a password. Refer to paragraph 6.4 for more information.
SWC
An abbreviation for Surge Withstanding Circuitry.
System Clock
A clock inside the RFL 9745 that time-stamps and date-stamps all event records. The system clock can be manually set, or connected to an IRIG-B generator for automatic synchronization.
System Label
A name assigned to a particular RFL 9745 terminal. The system label appears on the second line of the main APRIL command list, and also appears on the RFL 9745's front-panel display during normal RFL 9745 operation.
Terminal Emulation Software
A program that permits a personal computer to imitate an ASCII terminal.
Test In Progress
The “Test In Progress” parameter can be either active or inactive. It is active if a checkback test or address test is currently in progress. Both of these tests require a small but finite time to be conducted. It is typically used to prevent tripping when “Test In Progress” is active. As an an example, refer to Figure 2-8 “6750 Audio Default Primitive Logic Diagram”. If the SOE trigger (See paragraph 6.1.3.5) is set to level 1, it is unlikely that the “Test In Progress” parameter will ever be captured as an active event record (See Figure 6-30). If the SOE trigger is set to level 2, Autotests are captured and the “test in progress” parameter will be active in those records.
TEST Menu
A menu that lists information about the RFL 9745's test performance. Viewed by pressing front-panel TEST switch.
Test Mode
An RFL 9745 mode during which RFL 9745 operation can be verified.
Timer
A logic primitive with one input and one output. The output tracks the input after a given time delay.
Timer Parameters
A general term for parameter settings that control RFL 9745 timer performance. (See "Attack" and "Decay.")
Tone
An audio signal used by the RFL 9745 for communication.
Tone Parameters
The programmable parameters that control how the RFL 9745's audio signals are generated and processed.
RFL 9745 December 22, 2006
11 - 11
RFL Electronics Inc. (973) 334-3100
Page 367
Transceiver
An RFL 9745 terminal that is configured to transmit and receive.
Transfer Filter
An RFL 9745 operating mode in which the RFL 9745 acts as a filter, accepting an input signal, amplifying and bandwidthlimiting it, and re-transmitting it.
Transmit Channel Delay
The amount of time it takes a transmit signal to pass from one RFL 9745 to another; usually half the channel round trip delay, assuming the transmit and receive delays are equal.
Transmit Level
The amplitude of the signal produced by the RFL 9745's transmitter.
Transmitter
An RFL 9745 terminal that is configured to transmit but not receive.
Transmitter Stability
An indication of how much the output frequency can be expected to vary due to temperature variations, input voltage variations, and other factors.
Trip
A tone or signal that is produced whenever a valid trip input is received.
Trip Boost
An operating feature that forces the transmit level to increase by a set amount for a specified time interval when the output shifts to its trip frequency.
Trip Hold Timer
A timer that keeps the trip output high for a specific interval, even if the trip condition ceases to exist.
UCA
Utility Communications Architecture
Unblocking
A Directional Comparison Relaying System utilizing communications, primarily FSK powerline carrier, to permit circuit breaker tripping for faults located internal to the protected line.
Update Mode
An RFL 9745 mode during which a display screen appears on the user's terminal or PC screen that is constantly updated with current information about RFL 9745 operation. Updates occur about once a second when the RFL 9745 is operating at 2400 baud.
Values Display
A display screen that shows the most recently-measured values for all RFL 9745 measured parameters.
Windows Remote APRIL
An RFL 9745 mode that allows an operator at one RFL 9745 to access the RFL 9745 at the other end of the communications link.
RFL 9745 December 22, 2006
11 - 12
RFL Electronics Inc. (973) 334-3100
Page 368
XON/XOFF
The protocol used by the RFL 9745 to establish connections with another RS-232 device; also called "software handshaking."
XOR Gate
A logic primitive with two inputs and one output. If one input is true and the other is false, the output is true. If both inputs are the same (either true or false), the output is false.
RFL 9745 December 22, 2006
11 - 13
RFL Electronics Inc. (973) 334-3100
Page 369
This page intentionally left blank
RFL 9745 December 22, 2006
11 - 14
RFL Electronics Inc. (973) 334-3100