Page 160

Section 4. USING THE RS-232 PORTS TO ACCESS THE RFL 9745 4.1 INTRODUCTION This section provides information on how to use the RFL 9745's RS-232 ports to access the RFL 9745 and configure it to suit your application.

4.2 ACCESSING THE RFL 9745 FROM A PC OR TERMINAL You can use the RS-232 connector on the front (DTE, data terminal equipment) or rear (DCE, data communication equipment) of the RFL 9745 to access it from a dumb terminal or a personal computer equipped with terminal emulation software. Hardware priority is given to the front port. Once connected, you can use APRIL (Asynchronous Programming and Remote Interrogation Language) LITE to do any of the following: 1.

View a list of parameter settings.

2.

Change parameter settings as required.

3.

Monitor RFL 9745 operation.

4.

Review lists of alarms.

5.

Review the sequence of events log.

Because APRIL is menu-based, you do not have to memorize the commands. Help screens can always be displayed by pressing the [H] key. To use APRIL, you will have to connect a terminal to the RS-232 connector on the front or rear of the RFL 9745. The terminal can be a dumb RS-232 terminal, or a PC or laptop computer with an RS-232 port running a terminal emulation program or the supplied PC APRIL LITE software. (See Section 9 for a description of the PC APRIL LITE software). The emulation mode must be either ANSI or VT100. You could also connect the RFL 9745's RS-232 port to one of the ports on an RFL 9660 Digital Switch or a stand-alone modem, and access the RFL 9745 with APRIL from a remote site. There is a difference between APRIL and PC APRIL. APRIL is software that is in the RFL 9745 chassis. PC APRIL LITE is software in the PC that communicates with APRIL via the RS-232 port.

RFL 9745 September 20, 2007

4-1

RFL Electronics Inc. (973) 334-3100

Page 161

With a dumb RS-232 terminal, or with a PC or laptop loaded with terminal emulation software, a user can do the following: 1. Communicate with an RFL 9745 2. Load (upload) files (System files, Batch files or MHX files) With a PC or laptop loaded with PC APRIL LITE software, a user can do the following: 1.

Communicate with an RFL 9745

2.

Load (upload) files (System files, Batch files or MHX files)

3.

Retrieve (download) files (Batch files or MHX files)

RFL 9745 September 20, 2007

4-2

RFL Electronics Inc. (973) 334-3100

Page 162

4.2.1 COMMUNICATION INFORMATION The serial port on your terminal or computer must be configured the same as the RFL 9745's serial port. Settings are as follows: Data Bits Stop Bits Parity Baud Rate Flow Control: (Handshaking)

8 1 None 300, 1200, 2400, 9600, or 19,200 baud XON/XOFF

4.2.1.1 BAUD RATE SELECTION "Baud rate" determines how fast data is sent through the RS-232 port. To set the baud rate, use the following procedure: 1.

On the rear panel, make sure the POWER switch on the Power Supply I/O Module behind the Main Power Supply Module is in the ON position.

2.

If the RFL 9745 is equipped with a redundant power supply, make sure the POWER switch on the Power Supply I/O Module behind the Redundant Power Supply Module is in the ON position.

3.

There are five pushbutton switches on the front panel, bracketed under the word "SELECT," with a switch labeled "ENTER" next to it. Press the switch labeled "LEVELS". "TRANSMIT 1" will appear on the top line of the front-panel display, with a number on the bottom line.

4.

Press the "UP" pushbutton switch next to the display. The following prompt will appear on the display: APRIL LITE BAUD RATE (any one of the following numbers: 300, 1200, 2400, 9600, 19200)

5.

Press the "ENTER" pushbutton switch to select this parameter, then press the "UP" and "DOWN" pushbutton switches until the desired baud rate appears on the bottom line of the display.

6.

Press the "ENTER" pushbutton switch to select this baud rate. The RFL 9745's RS-232 ports are now set to the desired baud rate.

RFL 9745 September 20, 2007

4-3

RFL Electronics Inc. (973) 334-3100

Page 163

4.2.1.2 FLOW CONTROL (HANDSHAKING) "Handshaking" is a protocol used by RS-232 devices to establish connections. The RFL 9745 uses "XON/XOFF" software handshaking. It uses characters sent through the port to control data flow, and requires no additional cable connections.

4.2.1.3 FRONT-PANEL RS-232 CONNECTIONS Figure 4-1 shows the connections that are required between your terminal or PC and the RS-232 connector on the front panel of the RFL 9745. To Terminal or PC

To RFL9745 Front Panel 1 2 3 4 5 6 7 8 9

RXD

2 3 20 7

TXD DTR F GND

2 3 4 5

RTS CTS

9-Pin D-Subminiature DB-25 Male Connector plugs DB-9 Female Connector Male Connector plugs into Female Connector on plugs into Male Connector on into Female Connector Terminal or PC Terminal or PC on front of RFL 9745 Figure 4-1. Cable connections between RFL 9745 and PC or terminal

4.2.1.4 NULL MODEM CABLE CONNECTIONS Figure 4-2 shows the null modem cable connections between the RFL 9745 rear panel connector and the RS-232 connector on the rear panel of your terminal or PC.

To Terminal or PC

To RFL9745 Rear Panel 5 2 3

F GND RXD

TXD RXD

TXD

9-Pin D-Subminiature Female Connector plugs into Male Connector on Rear of Terminal or PC

9-Pin D-Subminiature Female Connector plugs into Male Connector on Rear of RFL 9745 Figure 4-2. Null modem cable connections.

RFL 9745 September 20, 2007

5 3 2

4-4

RFL Electronics Inc. (973) 334-3100

Page 164

4.2.1.5 REAR-PANEL RS-232 CONNECTIONS Figure 4-3 shows the connections that can be made between the RFL 9745 rear panel connector and the RS-232 connector on the rear panel of the RFL 9660.

TO RFL 9745 REAR PANEL CONNECTOR

TO RFL 9660 REAR PANEL CONNECTOR

NOT USED

1

1

DCD (DATA CARRIER DETECT)

RECEIVE DATA (RXD)

2

2

TXD

TRANSMIT DATA (TXD)

3

3

RXD

NOT USED

4

4

DTR

SIGNAL COMMON

5

5

SIGNAL COMMON

NOT USED

6

6

DSR (DATA SET READY)

REQUEST-TO-SEND (RTS)

7

7

RTS

CLEAR-TO-SEND (CTS)

8

8

CTS

NOT USED

9

9

NOT USED

9-PIN D-SUBMINIATURE FEMALE CONNECTOR (DB-9) PLUGS INTO MALE CONNECTOR ON REAR OF UNIT

9-PIN D-SUBMINIATURE FEMALE CONNECTOR (DB-9) PLUGS INTO MALE CONNECTOR ON REAR OF UNIT

Figure 4-3. Cable connections between RFL 9745 and RFL 9660 Digital Switch.

NOTE Any device connected to the front-panel RS-232 connector must drive the DTR line high. This will disable the rear-panel RS-232 port, eliminating any conflict that may arise from two users attempting to access the RFL 9745 at the same time. Most serial ports drive the DTR line high.

RFL 9745 September 20, 2007

4-5

RFL Electronics Inc. (973) 334-3100

Page 165

4.2.1.6 CONNECTING A REMOTELY LOCATED PC TO THE RFL 9745 USING MODEMS To connect a remotely located PC to the 9745 using modems, refer to Figures 4-4a or 4-4b as applicable. The modems used in Figure 4-4a must have the S64 parameter.

RS-232 front panel connector

9745 local PC (data from/to send port)

9745

RS-232 front panel connector

9745

RS-232 rear panel connector local PC

9745 RS-232 rear panel connector

Modem 2

9660 Modem phone line phone line

Modem 1

4-4a

Modem remote PC

4-4b remote PC

Figure 4-4. Connecting a remote PC to the RFL 9745 using modems

The 9745 transmits data from its send port at all times since the CTS (clear to send) line is always active. When modem 1 tries to dial up modem 2, modem 2 will go offhook momentarily. Modem 2 will see the data from the 9745 and will fail to connect since this data disrupts the handshaking between the two modems. Both modems must have the S64 parameter which is the Dial/Answer Sequence Abort parameter, which has a default of 0. The S64 parameter controls whether or not the modem aborts a dialing or answering sequence if characters are transmitted by the local DTE (the 9745) before a connection is established. In the 0 position, the modem aborts the dialing or answering sequence if characters are transmitted before a connection is established. In the 1 position, the modem will ignore any characters sent by the local DTE (the 9745) while dialing or answering a call. In order to function properly both modems must have their S64 parameters enabled. This is not a problem when using a 9660 switch as shown in Figure 4-3b since the modems make their connections before the connection is made between the 9745 and the 9660.

RFL 9745 September 20, 2007

4-6

RFL Electronics Inc. (973) 334-3100

Page 166

4.2.2 TESTING RS-232 ACCESS Once you have connected a terminal to the RFL 9745 (either directly or through an RFL 9660 Digital Switch), and have configured the serial port of your terminal or computer the same as the RFL 9745’s serial port, then press the [ENTER] key. The RFL 9745 will send the following prompt to your terminal: 9745> This means that you have accessed the RFL 9745, and can now use APRIL commands to view lists of parameter settings, alarm conditions, and other information. To view a list of the APRIL commands, press the [H] and [ENTER] keys: 9745>H [ENTER] This tells the RFL 9745 to send a list of APRIL commands to your terminal. A typical APRIL command list appears in Figure 4-5.

RFL Electronics APRIL(t) Remote Communications, Version 2.0 (c) 1993, 1994 System Label H - Display the main menu A - Go to the alarms display V - Go to the values display P - Go to the programming menu (password required) D - Go to the read settings menu F - Go to the configuration and software version display K - Go to the logic programming menu (password required) T - Go to the test menu U - Enter the update mode X - Exit the update mode S - Go to sequence of events menu W - Window remote April 9745> Figure 4-5. APRIL commands for use with RFL 9745

Once you have accessed the RFL 9745, use the procedures in Section 5 to set up the RFL 9745. Then you can use the procedures in Section 6 to program the RFL 9745 to suit your application, perform tests, and view the sequence-of-events log.

RFL 9745 September 20, 2007

4-7

RFL Electronics Inc. (973) 334-3100

Page 167

This page intentionally left blank

RFL 9745 September 20, 2007