Page 1 of Operating Instructions: CLV490 Bar Code Scanner, Advanced Line

Manual · Sick

Operating Instructions: CLV490 Bar Code Scanner, Advanced Line

Manual266 pagesPDF 5.1 MB

Operating instructions for the SICK CLV 490 bar code scanner: mounting, wiring, CLV-Setup configuration, troubleshooting and data sheets.

Download the PDF5.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

Operating instructions for the SICK CLV 490 fixed-mount bar code scanner, as a line scanner or a line scanner with oscillating mirror, in the -0010 to -7011 variants. It covers safety, the product and its autofocus, mounting and alignment, electrical installation with the CDB 420 or CDM 490 connection modules and cable pinouts, startup and configuration with the CLV-Setup program, operating modes, maintenance, troubleshooting and error messages, and data sheets for each variant.

Its parts

  1. Notes on this document
  2. Safety information
  3. Product description
  4. Installation
  5. Electrical installation
  6. Operation
  7. Maintenance
  8. Troubleshooting
  9. Technical data

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operating instructions for the SICK CLV 490 Advanced Line laser bar code scanner, covering the line scanner and oscillating mirror variants with and without heater (CLV 490-0010 through CLV 490-7011). It explains mounting, wiring through SICK connection modules, setup with the CLV-Setup PC program, error messages and troubleshooting, and lists the technical data and accessories.

Read for this summary: pages 1 to 3, 23 to 25, 51 to 52, 144 to 145, 163 to 165 and 241 to 242 of 266.

Device type
Laser bar code line scanner with a front reading window; oscillating mirror variants read through a side window p. 25
Data interfaces
Host: RS 232 or RS 422/485, 300 to 57,600 bd; CAN: CANopen, 10 kbit/s to 1 Mbit/s; terminal: RS 232, 9,600 bd p. 163
Connectors
One 15-pin D Sub HD plug and one 15-pin D Sub HD socket p. 163
Power, no heater
CLV 490-0010/-2010/-6010: 18 to 30 V DC, typically 11 W, max. 16 W; CLV 490-1010/-3010/-7010: typically 13 W, max 18 W p. 164
Power, heater types
CLV 490-0011/-2011/-6011 and -1011/-3011/-7011: 24 V DC +20 %/–10 %, typically 75 W, max 90 W p. 164, 165
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved p. 163
Reading range
Standard density line scanner: 500 to 2,100 mm (19.7 to 82.7 in) p. 25
Resolution
Standard density: 0.25 to 1.0 mm (9.8 to 39.4 mil) p. 25
Switching I/O
6 optodecoupled inputs (Sensor, IN 0 to IN 4); 4 PNP outputs (Result 1 to Result 4) p. 163
Weight
CLV 490-0010/-2010/-6010: approx. 1.5 kg (3.3 lb); CLV 490-1010/-3010/-7010: approx. 2.2 kg (4.84 lb) p. 164
Operating temperature
Without heater: 0 to +40 °C; heater types: –35 to +35 °C p. 164
Connection modules
CDB 420-001 (no. 1 023 885), CDB 420-101 (no. 1 024 305), CDM 490-0001 (no. 1 025 363); heater types use the CDM 490-0001 p. 24, 25
Cables
No. 2 020 264 (3 m, 15-pin D Sub HD to open end, for a non-SICK power pack); null modem PC cable no. 2 014 054 p. 24
Fieldbus modules
For the CDM 490: CMF 400-1001 Profibus-DP (1 026 241), CMF 400-2101 DeviceNet (1 026 242), CMF 400-3101 Ethernet TCP/IP (1 026 357) p. 242

What this manual walks you through

  • Choosing the variant by scanning method, resolution and heater p. 23
  • What is needed to run the scanner: connection module, power pack, cables, sensors, PC p. 24, 25
  • Connecting the scanner, interfaces and power through a connection module p. 51
  • Choosing prefabricated cables and connector covers p. 52
  • Reading coded error messages in the CLV-Setup Terminal Emulator p. 144
  • LED signals for problems with the external parameter memory p. 145
  • Technical data for each variant p. 163, 164, 165
  • Mounting accessories, connection modules and plug-in extension modules p. 241, 242

Good to know

  • The CMP 490 Power Supply Module (max. 25 W) cannot power the heater variants. p. 25
  • Heater variants: power wires of at least 0.75 mm2 (20 AWG) copper, no longer than 10 m. p. 52
  • Without heater, all connections need copper wire of at least 0.15 mm2 (26 AWG). p. 51
  • Heater variants take 35 to 40 minutes to come on at 24 V DC and –35 °C. p. 164
  • The laser diode switches off if the reading interval stays active too long or the output power is exceeded. p. 25

Questions this manual answers

What power supply does the SICK CLV 490 need?

Variants without heater take 18 to 30 V DC (the line scanner typically 11 W). Heater variants need 24 V DC +20 %/–10 % and typically 75 W. p. 164

What does CLV SYS-Failure mean on a CLV 490?

The scanner has found a system error: the Device Ready LED goes out and the system restarts. If the error returns after a restart, the manual says to contact SICK Service. p. 144

Which cable connects a CLV 490 to a non-SICK power pack?

Cable no. 2 020 264, 3 m (9.84 ft) long, with a 15-pin D Sub HD connector and one open end. p. 24

Can the CLV 490 run from AC mains?

Yes, through the CMP 490 Power Supply Module (2 030 091) in the CDM 490: 100 to 250 V AC in, 24 V DC out, max. 25 W. It is not suitable for the heater variants. p. 25, 242

How do I connect a CLV 490 to Profibus, DeviceNet or Ethernet?

Fit the matching CMF 400 fieldbus module into a CDM 490 connection module: CMF 400-1001 for Profibus-DP, CMF 400-2101 for DeviceNet, CMF 400-3101 for Ethernet TCP/IP. p. 24, 242

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Notes on this document17
    1. 1.1 Purpose17
    2. 1.2 Target audience17
    3. 1.3 Information content18
    4. 1.4 Symbols18
  2. 2 Safety information19
    1. 2.1 Authorized users19
    2. 2.2 Intended use19
    3. 2.3 General safety instructions and protection measures20
    4. 2.4 Quick stop and quick restart22
    5. 2.5 Environmental information22
  3. 3 Product description23
    1. 3.1 Design23
    2. 3.2 Method of operation28
    3. 3.3 Indicators and control elements32
  4. 4 Installation37
    1. 4.1 Installation sequence37
    2. 4.2 Preparations37
    3. 4.3 Mounting and adjusting the device43
    4. 4.4 Mounting the external components47
    5. 4.5 Dismantling the device50
  5. 5 Electrical installation51
    1. 5.1 Installation sequence51
    2. 5.2 Electrical connections and cables51
    3. 5.3 Connector pin assignment57
    4. 5.4 Preparations for electrical installation67
    5. 5.5 Electrical installation procedure69
  6. 6 Operation79
    1. 6.1 Overview of steps for starting up the CLV79
    2. 6.2 Default settings79
    3. 6.3 Quick start81
    4. 6.4 Configuring (parameterization) the CLV83
    5. 6.5 Operating modes and outputing the reading result117
    6. 6.6 CLV messages138
    7. 6.7 Switching off the CLV139
  7. 7 Maintenance141
    1. 7.1 Cleaning the CLV during operation141
    2. 7.2 Maintenance142
    3. 7.3 Disposal142
  8. 8 Troubleshooting143
32 more lines, from page 143 on
  1. 8.1 Overview of possible errors and malfunctions143
    1. 8.2 Monitoring error and malfunctions143
    2. 8.3 Error messages144
    3. 8.4 ST error status in the reading result of a bar code149
    4. 8.5 Troubleshooting151
    5. 8.6 SICK Support162
  2. 9 Technical data163
    1. 9.1 Data sheet CLV 490-0010/-2010/-6010 bar code scanner163
    2. 9.2 Data sheet CLV 490-1010/-3010/-7010 bar code scanner164
    3. 9.3 Data sheet CLV 490-0011 /-2011/-6011 bar code scanner164
    4. 9.4 Data sheet CLV 490-1011/-3011/-7011 bar code scanner165
    5. 9.5 Dimensioned drawings - CLV165
  3. 10 Appendix167
    1. 10.1 Overview167
    2. 10.2 Specification diagrams167
    3. 10.3 Installing and operating the external parameter memory (connector cover)200
    4. 10.4 Optional heating206
    5. 10.5 System messages208
    6. 10.6 Installing and operating the "CLV-Setup" program209
    7. 10.7 Configuring a CLV with command strings219
    8. 10.8 Calculating parameter values for setting the CLV221
    9. 10.9 Tables225
    10. 10.10 Discussion of a parameterization example226
    11. 10.11 Special applications and procedures235
    12. 10.12 Replacing a CLV (copying the parameter set)239
    13. 10.13 Accessories241
    14. 10.14 Dimensioned drawings of the accessories247
    15. 10.15 Supplementary documentation248
    16. 10.16 Glossary249
    17. 10.17 EC Declaration of Conformity258
    18. 10.18 Index259
    19. 10.19 Bar code example265

From the PDF’s own bookmarks.

The whole text · 30 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2217-22
  4. 3 Product description23-36
  5. 4 Installation37-50
  6. 5 Electrical installation, pages 51 to 6051-60
  7. 5 Electrical installation, pages 61 to 7061-70
  8. 5 Electrical installation, pages 71 to 7871-78
  9. 6 Operation, pages 79 to 8779-87
  10. 6 Operation, pages 88 to 9688-96
  11. 6 Operation, pages 97 to 10597-105
  12. 6 Operation, pages 106 to 114106-114
  13. 6 Operation, pages 115 to 123115-123
  14. 6 Operation, pages 124 to 132124-132
  15. 6 Operation, pages 133 to 140133-140
  16. Pages 141 to 148141-148
  17. Pages 149 to 156149-156
  18. Pages 157 to 162157-162
  19. 9 Technical data163-166
  20. 10 Appendix, pages 167 to 176167-176
  21. 10 Appendix, pages 177 to 186177-186
  22. 10 Appendix, pages 187 to 196187-196
  23. 10 Appendix, pages 197 to 206197-206
  24. 10 Appendix, pages 207 to 216207-216
  25. 10 Appendix, pages 217 to 226217-226
  26. 10 Appendix, pages 227 to 236227-236
  27. 10 Appendix, pages 237 to 246237-246
  28. 10 Appendix, pages 247 to 256247-256
  29. 10 Appendix, pages 257 to 262257-262
  30. 10 Appendix, pages 263 to 266263-266

The file

Revision and size

Revision8 009 993/O824/20-12-2004
PublisherSICK AG
Pages266
PDF5.1 MB
TextText from the PDF itself.

The first pages · 3 of 266

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 266
Page 2
Page 2of 266
Page 3
Page 3of 266

More documents · 2

For the same models