Operating Instructions: CLV490 Bar Code Scanner, Advanced Line: 10 Appendix, pages 227 to 236
Pages 227 to 236 of 266, from Operating Instructions: CLV490 Bar Code Scanner, Advanced Line
The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV490
Page 227
Appendix
Operating Instructions
Chapter 10
CLV 490 Bar Code Scanner
10.10.4 Important clarifications ¾ Sketch out the reading situation and enter the parameter values and variables for the CLV. a) View from the front y coord.
b) Side view alpha = 270°
Y1 beta = 10°
Z2 z coord.
1400
Y2 inch
100
3.94
200
7.9
300
11.8
550
21.7
600
23.6
700
27.6
1,400
55.2
700
10 x coord.
Z1 100 mm
LS 100
200 550 600
300
All values in mm
Fig. 10-44: Parameterization example: prepare a sketch of the reading situation
¾
Determine the reading range and installation height of the CLV above the conveyor belt: With a covered conveyor belt with a 600 mm (23.6 in) width, the CLV can read an object at a distance of 600 mm (23.6 in) (according to the reading field diagram in Fig. 10-1, Page 10-3). For a reserve of an additional 100 mm (3.9 in) and a maximum package height of 600 mm (23.6 in), the resulting reading range of the CLV can be set to 700 to 1,300 mm (27.6 to 51.2 in) from the reading window. The CLV is to be mounted 1,400 mm (55.2 in) above the conveyor belt, as the package must be at least 100 mm (3.9 in) high.
¾
Determine the CLV’s distance measurement type: For the required total field depth range of 600 mm (23.6 in), a height detection of the focal position changeover is required. This is carried out by activating the CLV’s direct distance measurement (the basis of the autofocus function).
10.10.5 Mounting and electrical connection
8 009 993/O824/20-12-2004
1.
Mount the CLV centered 1,400 mm (55.2 in) above the conveyor belt (vertically) according to a) Fig. 10-44, reading window facing downward.
2.
Align and screw in the CLV in a reading axis with the reading window at a 10° angle against the required reading direction as shown in b) Fig. 10-44 The CLV can carry out a distance measurement from the front of the package to the top of the package while it is in motion.
3.
Attach the pulse photoelectric switch and reflector to the conveyor belt so that there is a distance of approx. 100 mm (3.9 in) between the photoelectric switch and the scan line position on the package with the smallest height.
4.
Connect the CLV to the CDB 420 or CDM 490 connection module. (see Chapter 5.2.3 Connections/cables for the CDB 420 Connection Modules, Page 5-3) respectively Chapter 5.2.4 Connections/cables for the CDM 490 Connection Module, Page 5-5.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-61
Page 228
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
5.
Connect the pulse photoelectric switch to the CDB 420 or CDM 490 connection module (see Chapter 5.5.7 Connecting the "Sensor" switching input, Page 5-23).
6.
Turn on the supply voltage to the CLV.
10.10.6 Parameterize the CLV with the "CLV-Setup" program 1.
Connect the PC to the CLV’s terminal interface (see Chapter 5.5.6 Connecting the PC, Page 5-22)
2.
Start Windows and the "CLV-Setup" program on the PC.
3.
Invoke the CLV 490’s default setting in the "CLV-Setup" program (see Chapter 6.1 Overview of steps for starting up the CLV, Page 6-1).
4.
Parameterize the CLV with the help of Chapter 6.4.4 Guide to parameterization menu, Page 6-9 and the tab cards by following the steps described.
5.
After completing parameter value alterations, download them to the CLV! (see chapter Chapter 6.4.1 Configuring the CLV via the user interface of CLV-Setup, Page 6-5).
1. Setting up the autofocus function (Part 1): READING CONFIGURATION tab ¾
Set the following parameters: – Scanning frequency: 800 Hz – Start/stop ratio: auto – Trigger for focus position changeover: autofocus – Autofocus mode: differential background
Fig. 10-45: Parameterization example: settings on the "Reading Configuration" tab
¾
Click on the AUTOFOCUS PARAMETERS button. The AUTOFOCUS PARAMETERS tab then opens (Fig. 10-46).
¾
Set the following parameters: – Preference of focus distance: Fix focus position: 1,200 mm (47.3 in) (approx. 100 mm (3.9 in) above the packet with the smallest height)
10-62
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 229
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
Fig. 10-46: Parameterization example: "Autofocus Parameters" tab
¾
To set the background, click the AUTOFOCUS LIMITS PARAMETERS button. The AUTOFOCUS LIMITS tab then opens (Fig. 10-47). The background is formed using the autofocus area’s terminating planes. The CLV registers the altered reading distances in this area only. – Autofocus limitation:
min: 600 mm (23.6 in); max: 1,400 mm (55.2 in)
– Autofocus space: (Limiting levels from feed level)
Right edge of conveyor (Y1): Left edge of conveyor (Y2): Level of conveyor (Z1): Maximum scanning height (Z2):
50 mm (2 in) 550 mm (21.7 in) 50 mm (2 in) 800 mm (31.5 in)
Fig. 10-47: Parameterization example: "Autofocus Limits" tab
¾
8 009 993/O824/20-12-2004
Close the AUTOFOCUS LIMITS PARAMETERS tab.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-63
Page 230
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
¾
On the AUTOFOCUS PARAMETERS tab, click the AUTOFOCUS OPTIMIZATION PARAMETERS button. The AUTOFOCUS OPTIMIZATION PARAMETERS tab then opens (Fig. 10-48).
¾
Set the following parameters: – Delay of focus change Timeout: 50 ms Hysteresis: 50 mm (2 in) – Distance Measurement: active Source of distance information: internal Smooth filter active: active Length: 3 (default setting)
Fig. 10-48: Parameterization example: "Autofocus Optimizations" tab
¾
10-64
Close the AUTOFOCUS OPTIMIZATION PARAMETERS tab.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 231
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
2. Setting up the autofocus function (Part 2): DEVICE CONFIGURATION tab
Fig. 10-49: Parameterization example: Buttons on the "Device Configuration" tab
¾
Click on the SCANNER POSITION PARAMETERS button. The SCANNER POSITION PARAMETERS tab then opens (Fig. 10-50).
Fig. 10-50: Parameterization example: "Scanner Position Parameters" tab
Set the following CLV position definition parameters regarding the movement level (see also Fig. 10-44, Page 10-61): ¾
Set the following parameters in the ANGLES section: – Angle alpha: 90 degrees (Laser beam’s direction of deflection relative to the direction of convoyer belt. – Angle beta: 10 degrees (Laser beam’s angle of incidence relative to the perpendicular in the area (Skew to the barcode), 10 degrees in the direction of feed)
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-65
Page 232
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
– Angle gamma: 0 degrees (Divergence of the scanner (reading windows) from the perpendicular in the plane askew to the direction of feed) ¾
Set the following parameters in the COORDINATES section: – X coordinate: Measure the distance from the pulse photoelectric switch to the CLV’s reading window perpendicular! (x offset + x coordinate = the distance from the pulse photoelectric switch to the CLV’s reading window perpendicular) – Y coordinate: 300 mm (11.8 in) (The middle of the CLV to the left edge of the conveyor belt in the direction of convoyer belt) – Z coordinate: 1,400 mm (55.2 in) (Height of the CLV above the conveyor belt)
¾
Close the SCANNER POSITION PARAMETERS tab.
3. Set the reading pulse source: DEVICE CONFIGURATION tab ¾
In the READING TRIGGER MODE section click the option Sensor Input (Active High).
¾
In the Output on Good read section click the option End of label.
Fig. 10-51: Parameterization example: Settings on the "Device Configuration" tab
¾
10-66
Close the tab.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 233
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
4. Set the evaluation properties: CODE CONFIGURATION tab ¾
Set the following parameters: - Codes: 2/5 Interleaved; deactivate all other code types! (remove check) - Number of Codes: Minimum 1, Maximum 1 - Code Positions: deactivate (remove check) - Decoder: SMART/Standard
Fig. 10-52: Parameterization example: settings on the "Code Configuration" tab
¾
For 2/5 interleaved, click on the EDIT button. The 2/5 INTERLEAVED tab then opens (Fig. 10-53).
¾
Set the following parameters: - Code Length: Fixed; length 1: 14 characters - Multiple Reads for Length 1: 3 - Check Digit Test for Length 1: mod 10 - Transmit Check Digit: activate - Transmit Leading Zero: activate
Fig. 10-53: Parameterization example: "2/5 Interleaved" tab
¾
8 009 993/O824/20-12-2004
Close the tab.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-67
Page 234
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
5. Set the output properties: HOST INTERFACE tab ¾
Set the CLV’s end-user communication condition parameters.
Fig. 10-54: Parameterization example: "Host interface" tab (default setting)
DATA STRINGS tab ¾
Set the CLV output message format in the end-user communication conditions.
Fig. 10-55: Parameterization example: "Data Strings" tab (default setting)
¾
Perform a download to CLV.
10.10.7 Testing the application ¾
10-68
Check the reading rate with the Terminal Emulator in the CLV-Setup while an application is running. The reading rate should be > 90%.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 235
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
10.11 Special applications and procedures 10.11.1 Auxiliary input via terminal interface If the CLV cannot read a bar code in Reading mode (e. g. if there is no bar code on the object), the data content of the bar code can be sent subsequently to the host by using the "Auxiliary input" function. In this way, the sequence of reading results can be completed if necessary. The auxiliary input function uses the terminal interface of the CLV exclusively and features two options: •
Manual entry of the data content on the keyboard of a connected terminal or PC (Terminal Emulation function)
•
Entry of the bar code using a hand-held reader. The data is then forwarded to the CLV via an internal or external decoder.
Fig. 10-56 shows the basic auxiliary input principle.
CLV
Data contents + Status ST=7
HOST Data contents
Fig. 10-56: Auxiliary input via the terminal interface of the CLV
The CLV sends the data content of the bar code that it receives via the terminal interface to the host in the same format as the other reading results on the host interface. Each string can contain the data from a bar code with a maximum length of 50 characters. The CLV automatically enters the status ST = 7 if the error status has been enabled for transmission. The values of the other reading diagnosis data in the data string do not have any significance. To enable the CLV to receive the data content of the bar code on the terminal interface, you must switch the operating mode on the interface to auxiliary input.
8 009 993/O824/20-12-2004
1.
Connect the PC to the terminal interface on the CLV using a 3-core RS 232 data cable (null modem cable) (CDB 420 or CDM 490: connect the PC to the internal 9-pin "Aux" plug). See Chapter 5.5.6 Connecting the PC, Page 5-22.
2.
Start CLV-Setup on your PC. See Chapter 10.6.3 Starting CLV-Setup, Page 10-46.
3.
Choose the AUXILIARY INTERFACE tab.
4.
Choose the AUXILIARY INPUT option from the drop-down list.
5.
Download the changes to the CLV. To do so, click the AUXILIARY INPUT option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-69
Page 236
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
The terminal interface then operates temporarily in "Auxiliary input" mode (until the CLV is switched off). Entering the bar code using the Terminal Emulator function in CLV-Setup 1.
Click on the toolbar. The Terminal Emulator is launched. The CLV is in Reading mode.
2.
Click the EXTENDED radio button in the TERMINAL MODE section. The start and stop characters used by the Terminal Emulator are displayed at the top of the screen, on the left and right of the text input field. Fig. 10-57 shows the Terminal Emulator window in extended mode.
3.
Use the drop-down lists to set the start and stop characters to NUL.
4.
Enter the data content of the bar code (character string) on the keyboard. Use the backspace key to correct any input errors. The data content must not contain control characters.
5.
Press the [RETURN] or [ENTER] key. The CLV then interprets all further characters as a new data string. CLV-Setup sends the character string to the CLV and deletes the entry in the text field. The CLV does not send an echo.
6.
Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.
Fig. 10-57: CLV-Setup: auxiliary input via the Terminal Emulator