Page 237
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
Entering a bar code using a terminal/PC keyboard 1.
Connect the terminal /PC with Terminal Emulation program to the terminal interface on the CLV (via CDB 420 or CDM 490). For the pin assignment, see Chapter 5.5.6 Connecting the PC, Page 5-22.
2.
Set the communication parameters and data output format as shown in Table 10-9.
Parameter
Value
Data transmission rate
9,600 bd
Data bits
8
Parity
None
Stop bits
1
Data output format
Data e. g. 1234 terminator CR
Table 10-9: Communication parameters on the terminal/PC for the auxiliary input
3.
Enter the data content of the bar code on the keyboard. The terminal sends the individual characters to the CLV immediately. Use the backspace key to correct input errors.
4.
Terminate the data content with the control character <CR>. The CLV then interprets all further characters as a new data string and ignores other control characters. The data content itself must not contain any control characters.
5.
Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.
Entering bar codes using a hand-held scanner (with integrated decoder) 1.
Connect the hand-held scanner with decoder to the terminal interface of the CLV (via CDB 420 or CDM 490). For the pin assignment, see Chapter 5.5.6 Connecting the PC, Page 5-22.
2.
Set the data format and communication parameters on the hand-held scanner as shown in Table 10-9.
3.
Read the bar code with the hand-held scanner. Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.
If you connect a SICK Hand-held Scanner from the IT 38xx/46xx/48xx/58xx series, set the communication parameters and data output (data + terminator) as shown in Table 10-10. Parameter
Value
Data transmission rate
9,600 bd
Data bits
8
Parity
No
Stop bits
1
Data interface
RS 232
Prefix (Header)
Clear all Prefixes
Suffix (Terminator)
CR
Table 10-10: Communication parameter settings for the SICK Hand-held Scanner from the IT 38xx/46xx/48xx/58xx series
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-71
Page 238
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
10.11.2 Connection to Profibus DP See Operating Instructions "CMF 400-1x01 Field Bus Gateway for Profibus DP" (no. 8 010 462, English edition). 10.11.3 Connection to the DeviceNet See Operating Instructions "CMF 400-2101 Field Bus Gateway for DeviceNet" (no. 8 010 464, English edition). 10.11.4 Connection to Ethernet TCP/IP See Operating Instructions "CMF 400-3101 Field Bus Gateway for Ethernet TCP/IP" (no. 8 010 735, English edition). 10.11.5 Building a CAN Scanner Network See Operating Instructions "Application of the CAN interface" (no. 8 009 180, English edition). 10.11.6 Integration in an OPS reading system See Operating Instructions "Omni Tracking System OTS 400" (no. 8 008 869, English edition).
10-72
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 239
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
10.12 Replacing a CLV (copying the parameter set) There are two methods of replacing a CLV and transferring the current parameter set to the new device: •
By downloading the parameters from CLV-Setup
•
By importing the parameter set from the external memory
The parameter set can only be transferred between identical device types (e. g. from one CLV 490 to another CLV 490, etc.). 10.12.1 Downloading the parameter set To download the parameter set, you must connect a PC running the "CLV-Setup" software to the replacement device. The parameter set of the CLV that is to be replaced must be available as a configuration file in CLV-Setup, otherwise the device must be parameterized from scratch. 1.
Disconnect the power supply to the CDB 420 or CDM 490 Connection Module (of the CLV).
2.
Disconnect all cable connectors from the CLV.
3.
Remove the CLV from the bracket. Before doing so, mark the position and alignment on the bracket/station.
4.
Mount, align, and connect the replacement device.
5.
Connect the PC to the terminal interface on the CLV using a 3-core RS 232 data cable (null modem cable) (CDB 420 or CDM 490: connect the PC to the internal, 9-pin "Aux" plug). See Chapter 5.5.6 Connecting the PC, Page 5-22.
6.
Switch on the power supply to the CDB 420 or CDM 490. Once the CLV has started, the "Device Ready" LED lights up.
7.
Switch on your PC and start Windows.
8.
Start CLV-Setup. If the communication parameters on the PC and CLV are identical, CLV-Setup uploads the parameter set from the CLV and displays the values on the tabs.
9.
Open the archived parameter set as a configuration file "*.scl" in CLV-Setup and download it to the CLV.
10. Confirm the dialog box by choosing the TEMPORARY storage option. 11. Check whether the CLV reads the bar codes correctly. Correct the parameter settings if necessary. 12. Finally, download the tested parameter set to the CLV and save it with the PERMANENT storage option. The parameter set is transferred permanently to the replacement device. 13. Save the modified parameter set as a new configuration file in CLV-Setup. Troubleshooting If the software version on the replacement device is older than the version on the old device (e. g. new device is from warehouse stock), the parameter set transferred may contain coded parameters or parameter values that cannot be interpreted by the older software. The new device, however, outputs an error message in CLV-Setup for each of these parameters/values when the parameter set is downloaded. ¾
8 009 993/O824/20-12-2004
Check whether all of the parameter settings used are necessary to configure the CLV for the current reading application. If necessary, replace the software version in the new device.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-73
Page 240
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
If the software version on the new device is more recent than that on the old one, the default settings in the imported parameter set will include parameters that were not contained in the old version. ¾
Upload the parameter set and check whether the new parameters are relevant for configuring the CLV for the current reading application. If necessary, change the parameter values and download the parameter set to the CLV again. Save the new parameter set as a configuration file in CLV-Setup.
See also Chapter 10.6.10 Unknown parameters, Page 10-51. 10.12.2 Importing the parameter set from the external memory a) External memory in the connector cover A PC does not have to be connected to import the parameter set from the external memory. The parameter set in the external memory must contain an up-to-date copy of the set used by the CLV that is to be replaced. Otherwise, the replacement device will import a different parameter set to its RAM when it is started. The start option in the device must be set to START WITH EXTERNAL PARAMETERS. This is the default setting. 1.
Switch off the power supply to the CDB 420 or CDM 490 Connection Module (of the CLV).
2.
Remove the connector cover (containing the parameter memory) from the CLV.
3.
Remove the CLV from the bracket. Mark the position and alignment of the CLV on the bracket station.
4.
Mount the connector cover on the terminals correctly and screw it into place.
5.
Mount and align the replacement device.
6.
Switch on the power supply to the CDB 420 or CDM 490. The CLV starts and loads the parameter set from the external memory to the RAM. The "Device Ready" LED blinks for approx. 10 s and then lights up constantly.
The parameter set is transferred temporarily to the replacement device. It is lost when the device is switched off but is loaded again from the external memory the next time the CLV starts. See also Chapter 10.3.8 Replacing a CLV, Page 10-39. Troubleshooting If the software version on the replacement device is older than that of the parameter set in the external memory (e. g. if the replacement device originated from the warehouse), the loaded parameter set may contain parameters or parameter values that cannot be interpreted by the older software. In this case, the "Device Ready" and "Read Result" LEDs blink together for approx. 10 s, after which the "Device Ready" LED lights up constantly. See also Chapter 10.6.10 Unknown parameters, Page 10-51. If the software on the replacement device is newer than that of the parameter set in the external memory, the parameter set loaded from the external parameter memory to the replacement device will contain new parameters that are set to the default values. b) External memory CMC 400 in the CDB 420 or CDM 490 Connection Module For procedure see Chapter 10.3.1 Function of the external parameter memory, Page 10-35.
10-74
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 241
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
10.13 Accessories 10.13.1 Mounting accessories Order No.
Description
Figure
2 016 110
Quick clamping device, complete with securing material
Fig. 10-60, Page 10-81
2 013 824
Angle bracket, single, with 2 screws M6 x 10 mm (0.39 in), self-locking
Fig. 10-58, Page 10-81
2 018 435
Articulated bracket (two angle brackets 2 013 824), with 2 screws M6 x 10 mm (0.39 in), self-locking
Fig. 10-59, Page 10-81
Table 10-11: Accessories: mounting accessories
10.13.2 Connection modules Order No.
Type
Description
1 023 885
CDB 420-001
Connection Module for one CLV 490, with: • 1 x 15-pin D Sub HD socket • 4 x cable glands (dia. 4.5 to 10 mm (0.18 to 0.39 in)) • terminal strips (signal distributor) for connecting the data and function interfaces • 1 x internal 9-pin D Sub plug "Aux" • 5 x LED (status indicator) • polycarbonate housing, enclosure rating max. IP 65 • operating temperature –351) to +40 °C (–31 to +104 °F) • operating voltage 10 to 30 V DC
1 024 305
CDB 420-101 as CDB 420-001, but with: • 2 x cable glands (dia. 4.5 to 10 mm (0.18 to 0.39 in)) • 2 x M12-connections (1 x plug, 1 x socket)
1 025 363
CDM 490-0001 Connection Module for one CLV 490, with: • 1 x 15-pin D Sub HD socket and 15-pin D Sub HD plug • 6 x cable glands (dia. 4.5 to 10 mm (0.18 to 0.39 in)) • terminal strips (signal distributor) for connecting the data and function interfaces • 1 x internal 9-pin D Sub plug "Aux" • 11 x LED (status indicator) • polycarbonate housing, enclosure rating max. IP 65 • operating temperature –351) to +40 °C (–31 to +104 °F) • operating voltage 10 to 30 V DC, power consumption 0.5 W without CLV 490
Design
1) Without any mounting or electrical installation work, otherwise –20 °C (–4 °F)
Table 10-12: Accessories: connection modules
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-75
Page 242
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
10.13.3 Extensions for connection modules Order No.
Type
Description
Design
1 023 850
CMC 400-101
Parameter memory (Connection Module Cloning) as plug-in module for the CDB 420 or CDM 490 Connection Module. Storage of parameter set for CLV 490 (from firmware V 3.50). Rotary code switch for activating the net work mode for the CLV 490. Operating temperature 0 to +40 °C (+32 to +104 °F), operating voltage 10 to 30 V DC via CDB 420 or CDM 490, power consumption 0.5 W.
2 029 466
CDM 4001)
Display module (Connection Display Module), 4 x 20 digits (LCD) with keyboard in optional cover for the CDM 490 Connection Module. Representation of reading results, reading diagnosis data and messages from the CLV 490 (from firmware version V 3.50). Connection to the CDM 490 via ribbon cable. Operating temperature 0 to +40 °C (+32 to +104 °F), operating voltage 18 to 30 V DC via CDM 490, power consumption 1 W. Prerequisite: CMC 400-101 parameter memory for controlling the display.
2 030 091
CMP 4901)
Power Supply Module (Connection Module Power) in optional cover for the CDM 490 Connection Module. Power supply for CLV 490 from an AC power line. Input 100 to 250 V AC/50 to 60 Hz, output 24 V DC, max. 25 W (short-circuit proof). Connection to the CDM 490 via ribbon cable. Operating temperature 0 to +40 °C (+32 to +104 °F).
1 026 241
CMF 400-1001
Field bus gateway (Connection Module Fieldbus) as plug-in module for the CDM 490 Connection Module. For connecting one CLV 490 (from firmware version V 3.50) to Profibus-DP (slave) via RS 232 data interface. With 9-pin D Sub socket on front panel for bus connection (enclosure rating IP 20) and 5-core terminal strip for connecting 2 digital inputs and 2 digital outputs. Connection to the CDM 490 via connector, operating temperature 0 to +40 °C (+32 to +104 °F), operating voltage 18 to 30 V DC via CDM 490, power consumption 2 W.
1 026 643
CMF 400-1101 as CMF 400-1001, but with enclosure rating max. IP 65
1 026 242
CMF 400-2101
Field bus gateway (Connection Module Fieldbus) as plug-in module for the CDM 490 Connection Module. For connecting one CLV 490 (from firmware version V 3.50) to DeviceNet (slave) via RS 232 data interface. With shielded 5-pin M12 plug on front panel for bus connection (enclosure rating max. IP 65) and 5-core terminal strip for connecting 2 digital inputs and 2 digital outputs. Connection to the CDM 490 via connector, operating temperature 0 to +40 °C (+32 to +104 °F), operating voltage 18 to 30 V DC via CDM 490, power consumption 2 W.
1 026 357
CMF 400-3101
Field bus gateway (Connection Module Fieldbus) as plug-in module for the CDM 490 Connection Module. For connecting one CLV 490 (from firmware version V 3.50) to Ethernet TCP/IP via RS 232 data interface. With shielded 8-pin RJ-45 socket on front panel for bus connection (enclosure rating max. IP 65) and 5-core terminal strip for connecting 2 digital inputs and 2 digital outputs. Connection to the CDM 490 via connector, operating temperature 0 to +40 °C (+32 to +104 °F), operating voltage 18 to 30 V DC via CDM 490, power consumption 3 W.
6 029 030
–
Profibus connector, IP 65, for CMF 400-1101
–
6 029 064
–
Ethernet patch cable, IP 65, 1 m (39.4 in), für CMF 400-3101
–
–
1) simultaneous operation together with the CMD 400 Display Module not possible
Table 10-13: Accessories: Extensions for connection modules
10-76
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 243
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
10.13.4 Cables, external parameter memories in connector cover, connector covers a) CLV without heater Temperature range of connection material: Stationary: –30 to +70 °C (–22 to +158 °F); moving: 0 ... +70 °C (+32 to +158 °F) Order No.
Description
Wires
2 020 302
Length
Connection
2
15 x 0.25 mm (24 AWG)
3m (3.84 ft)
CLV 490 to CDM 490
15 x 0.25 mm2 (24 AWG)
10 m (32.8 ft)
as above
15 x 0.25 mm2 (24 AWG)
3m (3.84 ft)
CLV 490 to host (free wiring)
15 x 0.25 mm2 (24 AWG)
3m (3.84 ft)
CLV 490 to sensors, PLC and non-SICK power pack
15 x 0.23 mm2 (24 AWG)
3m (3.84 ft)
CLV 490 to CDB 420
Connection cable for data interfaces (“Host/Term“) or function interfaces ("I/O“), dia. 8 mm (0.32 in), shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug. Pin assignment identical to device connection, all pins connected. Enclosure rating max. IP 20. Required: 2 per CLV 2 021 815 as 2 020 302, but longer
2 020 303
Connection cable for data interfaces (“Host/Term“), dia. 8 mm (0.32 in), shielded, with 15-pin D Sub HD socket and open end (crimpted wires), all pins connected. Enclosure rating max. IP 20. Required: 1 per CLV 2 020 264
Connection cable for function interfaces and power supply ("I/O"), dia. 8 mm (0.32 in), shielded, with 15-pin D Sub HD plug and open end (crimpted wires). All pins connected. Enclosure rating max. IP 20. Required: 1 per CLV 2 027 046
Connector cover, one connection cable, dia. 6 mm (0.24 in), shielded, with 15-pin D Sub HD plug. Pin assignment see Chapter 5.3 Connector pin assignment, Page 5-7. Enclosure rating max. IP 65. Required: 1 per CLV Table 10-14: Accessories: Cables and connector covers for CLVs without heater
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-77
Page 244
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
Order No.
Description
Wires
2 030 023
Length
Connection
15 x 0.23 mm (24 AWG)
3m (3.84 ft)
CLV 490 to CDB 420 je 18 x 0.14 mm2 (26 AWG)
3m (3.84 ft)
CLV 490 to CDM 490 je 18 x 0.14 mm2 (26 AWG)
3m (3.84 ft)
CLV 490 to host, sensors, PLC and non-SICK power pack
3 x 0.34 mm2 (22 AWG)
3m (3.84 ft)
PC to CDB 420/ CDM 490
15 x 0.09 mm2 (28 AWG)
Cut to size
Free wiring
2
Connector cover with parameter memory (EEPROM), one connection cable, dia. 6 mm (0.24 in), shielded, with 15-pin D Sub HD plug. Pin assignment see Chapter 5.3 Connector pin assignment, Page 5-7. Enclosure rating max. IP 65. Required: 1 per CLV 2 020 307
Connector cover with parameter memory (EEPROM), two connection cables, each with dia. 8 mm (0.32 in), shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug. Pin assignment of each cable identical to device connection, however pin 13 and pin 14 of "I/O" connection not connected. Enclosure rating max. IP 65. Required: 1 per CLV 2 020 981
Connector cover with parameter memory (EEPROM), two connection cables, each with dia. 8 mm (0.32 in), shielded, with two open ends (crimpted wires). All pins connected, however pin 13 and pin 14 of "I/O" connection not connected. Enclosure rating max. IP 65. Required: 1 per CLV 2 014 054
RS 232 data cable (null modem cable), dia. 5 mm (0.19 in), shielded, with two 9-pin D Sub sockets, (Pin2 (RxD) and Pin 3 (TxD) crossed) 6 010 088
Data cable, dia. 6.6 mm (0.26 in), shielded, for connection cables up to 3 m (3.84 ft)
Table 10-14: Accessories: Cables and connector covers for CLVs without heater (contd.)
Note
10-78
Other cable lengths/types for CLV without heater available on request.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 245
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner b) CLV with heater Temperature range of connection material: Stationary: –50 to +70 °C (–58 to +158 °F); moving: –40 to +70 °C (–40 to +158 °F) Order No.
Description
Wires
2 033 126
Length
Connection
15 x 0.23 mm (24 AWG) + 2 x 1.5 mm2 (16 AWG)
10 m (32.8 ft)
CLV 490 to CDB 420 as 2 033 126
15 m (49.2 ft)
as above je 15 x 0.23 mm2 (24 AWG) + 2 x 1.5 mm2 (16 AWG)
3m (3.84 ft)
CLV 490 to CDM 490 as 2 030 065
10 m (32.8 ft)
as above
2
Connector cover with parameter memory (EEPROM), one connection cable, dia. 6 mm (0.24 in), shielded, with one 15-pin D Sub HD plug and one power supply cable, dia. 8.6 mm (0.34 in), shielded, open end (ferrules). Pin assignment see Chapter 5.3 Connector pin assignment, Page 5-7. Enclosure rating max. IP 65. Suitable for track chain use. Required: 1 per CLV 2 033 127 as 2 033 126, but longer
2 030 065
Connector cover with parameter memory (EEPROM), two connection cables, each with dia. 6 mm (0.24 in), shielded, with one 15-pin D Sub HD socket and with one 15-pin D Sub HD plug. Power supply cable, dia. 8.6 mm (0.34 in), shielded, open end (ferrules). Pin assignment of each cable identical to device connection, however pin 13 and pin 14 of "I/O" connection not connected. Enclosure rating max. IP 65. Suitable for track chain use. Required: 1 per CLV 2 031 034 as 2 030 065, but longer
Table 10-15: Accessories: Cables and connector covers for CLVs with heater
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-79
Page 246
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
Order No.
Description
Wires
2 021 267
Length
Connection
2 je 18 x 0.14 mm (26 AWG) + 2 x 1.5 mm2 (16 AWG)
3m (3.84 ft)
CLV 490 to host, sensors, PLC and nonSICK power pack je 10 x 0.14 mm2 (26 AWG) + 2 x 1.5 mm2 (16 AWG)
3m (3.84 ft)
CLV 490 to AMV 100/200
Connector cover, two connection cables, each with dia. 6.7 mm (0.26 in), shielded, with open ends (crimpted wires). All pins connected, however pin 10 to pin 15 of "Host/Term" connection (CAN interfaces 1 and 2) not connected, pin 13 and pin 14 of "I/O“ connection not connected. Enclosure rating max. IP 65. Required: 1 per CLV 2 027 543
Connector cover ("Scanner") with parameter memory (EEPROM) to connector cover ("AMV/BMV“), two connection cables, each with dia. 8 mm (0.32 in), shielded. Each cover with 15-pin D Sub HD socket and 15-pin D Sub HD plug. Pin assignment of each cable identical to device connection, however pin 11 to 14 (CAN interface) of "Host/Term" connection not connected. Pin 13 and pin 14 of "I/O“ connection not connected. Enclosure rating max. IP 65. Required: 1 per CLV Table 10-15: Accessories: Cables and connector covers for CLVs with heater (contd.)
Note
Other cable lengths/types for CLVs with heater available on request. 10.13.5 Plug-in connections
Order No.
Description
6 009 438 D Sub connector housing (metal) for 9-pin or 15-pin HD inserts 6 007 335 D Sub connector insert, 9-pin socket connector 6 010 019 D Sub connector insert, 15-pin HD socket connector 6 010 020 D Sub connector insert, 15-pin HD pin connector Table 10-16: Accessories: plug-in connections
10.13.6 Reading pulse generators The SICK catalog "SENSICK Industrial Sensors" (no. 8 006 530, English edition) contains a large selection of photoelectric switches and photoelectric proximity switches as well as the associated accessories (brackets, connection cables).
10-80