Page 247

Appendix

Operating Instructions

Chapter 10

CLV 490 Bar Code Scanner

10.13.7 Incremental encoder Order No.

Description

2 022 714

Incremental encoder with friction wheel, resolution 10 mm (0.39 in) per pulse, max. 100 KHz, operating voltage 18 to 28 V DC, operating temperature 0 to +70 °C (+32 to +158 °F). With mounting bracket and accessories, connection cable 10 m (32.8 ft) with M12 socket and open end

Table 10-17: Accessories: incremental encoder

10.14 Dimensioned drawings of the accessories 10.14.1 Angle bracket, single no. 2 013 824 30 8) 1 (1. 45 7) 7 (1.

6.526) (.

7.5 (.29)

Enclosed to securing the CLV: 2 x cylinder head screws M6 x 10 mm (0.39 in), self-locking

30 (1.18) 50 15 25 (1.97) (.59) (.98) 45 (1.77)

6.5 (.26)

ø 6.5 (.26)

97.5 (3.84)

6.5 (.26)

30 (1.18)

15 (.59)

56 (2.20)

7 (.27) 30 (1.18)

ø 6.5 (.26)

Fig. 10-58: Dimensions of the angle bracket, single No. 2 013 824

10.14.2 Articulated bracket No. 2 018 435

Enclosed to securing the CLV: 2 x cylinder head screws M6 x 10 mm (0.39 in), self-locking

68 (2.68)

Fig. 10-59: Dimensions of the articulated bracket No. 2 018 435

10.14.3 Quick clamping device No. 2 016 110

No. 2 016 110 Enclosed parts:

No. 2 013 824

– 2 x hexagon socket head screws M6 x 16 mm (0.63 in) – 2 x flat-head screws M6 x 12 mm (0.47 in) – 2 x washer A 6.4 – 1 x threaded pin M8 x 16 mm (0.63 in)

Fig. 10-60: Front view of quick clamping device No. 2 016 110 with angle braket No. 2 013 824

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-81

Page 248

Appendix

Chapter 10

Operating Instructions CLV 490 Bar Code Scanner

10.15 Supplementary documentation Order No.

Title

Language

Contents

8 010 001

"CDB 420 Connection Module" Operating Instructions

German/ English

Description for connecting the CLV to the host/PLC/sensor via the CDB 420 Connection Module

8 010 005

"CDM 490 Connection Module" Operating Instructions

German/ English

Description for connecting the CLV to the host/PLC/sensor via the CDM 490 Connection Module

8 010 002

“CMC 400 Connection Module Cloning“ Operating Instructions

German/ English

Description for installing the module in the CDB 420 or CDM 490 Connection Module

8 010 372

“CMD 400 Connection Display Module“ Operating Instructions

German/ English

Description for installing the module in the CDM 490 Connection Module

8 010 601

“CMP 490 Power Supply Module“ Fitting Instructions

German/ English

Description for installing the module in the CDM 490 Connection Module

8 010 462

“CMF 400-1x01 Field Bus Gateway for Profibus-DP“ Operating Instructions

English

Description for installing and setting up (configuration) the module in the CDM 490 Connection Module

8 010 464

“CMF 400-2101 Field Bus Gateway for DeviceNet“ Operating Instructions

English

Description for installing and setting up (configuration) the module in the CDM 490 Connection Module

8 010 735

“CMF 400-2101 Field Bus Gateway for Ethernet TCP/IP“ Operating Instructions

English

Description for installing and setting up (configuration) the module in the CDM 490 Connection Module

8 010 971

"Cold-resistent cable no. 2 033 126/ no. 2 033 127“ Fitting Instructions

German/ English

Description of installing the cable on the CDB 420

8 010 972

"Cold-resistent cable no. 2 030 065/ no. 2 031 034" Fitting Instructions

German/ English

Description of installing the cable on the CDM 490

8 009 180

“Application of the CAN interface“ Operating Instructions

English

Description of building a CAN scanner network (electrical connection, configuration of the CLV, functions) and the integration into a CANopen network

8 008 869

"Omni Tracking System OTS 400" Operating Instructions

English

Description of the integration of the CLV 490 in an omnidirectional OPS reading system

On request

Command strings

English

Description of the CLV command strings

Table 10-18: Supplementary documentation

10.15.1 CLV Connect (from version 1.9) Diagrams showing you how to connect the CDB 420 or CDM 490 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM).

10-82

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 249

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner

10.16 Glossary For further terms, please refer to the "CLV-Setup Help". Adjusting mode Special operating mode that enables the center of the scan line to be positioned exactly on the object containing the bar code. Aperture angle α Angle within whose limits the laser beam is deflected by the polygon mirror wheel. A V-shaped range perpendicular to the scan direction, which must contain the bar code, is formed in front of the reading window. If only part of this aperture angle is used (part of the scan line symmetric around the center point), the depth of field for the focus position and resolution is greater. Aspect ratio Ratio code height (bar length) to code length (numer of characters) Using the SMART Decoder even bar codes with very small code height can be read. Autofocus function Ability of the CLV to detect the distance of the objects during the reading operation without external sensors in order to adapt the focus position to the reading plane of the bar codes. Auxiliary input Special function on Ö the terminal interface. Used to enter bar code data subsequently in order to complete reading results sent to the host. Capture range Zone around a moving bar code created by the CLV using the increment management and code position comparison functions. Enables bar codes with identical contents and code type to be separated. Christmas tree effect Effect caused by limiting the active scan line range (CP values) and oscillating amplitude (CW values) on the Ö line scanner with oscillating mirror. In this way, a uniform sharply defined window can be created in the reading field for each distance configuration, independent of the reading distance. CLV-Setup PC program that runs on Windows 95TM /98TM, Windows NT4.0TM, Windows 2000TM, Windows XPTM and is used to parameterize the CLV offline (adjust the device to the local conditions) and operate it online. The parameter set is exchanged with the CLV by Ö uploading and Ö downloading it. CLV-Setup Help Online help function that provides support for using the "CLV-Setup" program. The help function explains the CLV parameters and their permissible values and can be launched directly from CLV-Setup in an HTML browser, such as Internet ExplorerTM.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-83

Page 250

Chapter 10

Appendix

Operating Instructions CLV 490 Bar Code Scanner

Code angle (CW value) Current deflection range of he scan line (oscillating mirror) perpendicular to the scan direction when a bar code is recorded. Calculated by the CLV for each scan and used, for example, to define a capture range so that bar codes with identical data contents in a given range can be separated. Code-Info/Separator Data block in the reading result on the Ö host interface. Used to provide additional information about the bar codes. Can be attached to the bar code as a prefix or suffix. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Code-Info/Separator" block is empty in the default setting of the CLV 490. Code geometry Length and height dimensions of the bar code. Code position (CP value) Position of the first dark bar in a detected bar code along the Ö scan line. Calculated by the CLV for each scan and can be used, for example, to separate bar codes with identical data contents. The active evaluation range in the scan line can be restricted for Ö decoding purposes by specifying the maximum and minimum CP value for the application. Command strings, commands CLV user interface – alternative to the "CLV-Setup" program. Basic, yet clearly structured command language for modifying the CLV parameter sets online. Accesses the CLV command interpreter directly. Special programming activities are required to use the command strings from the host. Configuration file File in the "CLV-Setup" program that archives the entire Ö parameter set of the CLV. Can also be printed out in tabular form. Data forwarding Option of forwarding data sent by the host transparently to a terminal via the CLV using an identifier. Data can also be forwarded in the opposite direction. Furthermore, this function also allows data received on one of the serial interfaces to be output again straight away on one of the same interfaces (echo). Application: forwarding reading results in pass-through mode, e. g. in a master/slave network. Data output string Structured data telegram in the Ö reading result output by the CLV on the Ö host interface. The structure of the data string is flexible and can be adapted to a large extent to the subsequent data processing task. The data output format of the Ö terminal interface, on the other hand, cannot be changed. Decoder, decoding Code-type-specific evaluation routine for reconstructing the read bar code in electronic form in order to decode its data content.

10-84

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 251

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner

Deflection angle Angle about each side of the center position CW = 50 (equal to 0°) that the Ö scan line sweeps when it is deflected by the oscillating mirror. Also referred to as the oscillating angle. Deflection range Deflection of the scan line caused by the Ö oscillating mirror, perpendicular to the scan direction about the center position CW = 50 at each side (corresponds to a deflection angle of 105°). Also referred to as oscillating amplitude. The maximum deflection range is set in OSCILLATING WITH FIXED AMPLITUDE mode. In OSCILLATING WITH VARIABLE AMPLITUDE mode, the deflection range is set for each distance configuration using the OSCILLATING MIRROR tab in the "CLV-Setup" program. Distance configuration Data record in the CLV for defining a Ö focus position for the laser beam for Ö dynamic focus control. The focus position as well as the maximum and minimum Ö code position must be entered on the READING CONFIGURATION tab in the "CLV-Setup" program for this purpose. In the case of the line scanner with oscillating mirror, the Ö oscillating amplitude (deflection range) is also required. The depths of field for the individual focus positions are shown as a function of the resolution values in the specification diagrams. Distance detector System for recording the distance of objects with a bar code in front of the CLV in stages. When the bar code is read from above, for example, the distance is detected by installing photoelectric reflex switches above one another beside the conveyor belt. Together with the combination of "IN 0" to "IN 4" switching inputs and the assignment table for the Ö distance configurations, the ranges for Ö dynamic focus control are defined. Only required if the Ö Autofocus function is not used. Distance profile When using the Ö Autofocus function with differential background (with or without tracking), the CLV can teach-in the ambient background (without objects) to narrow its active reading range. The CLV creates a profile of the various distances in its reading field along the scan lines in a special mode. This profile is then used to detect objects in the reading field and to set the required focus position at the level of the bar code on the object. Download Method of transferring the Ö parameter set that was modified with the Ö CLV-Setup program offline from the PC to the CLV. CLV-Setup either always transfers a complete copy to the memory (RAM) of the CLV (DOWNLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (DOWNLOAD PARAMETER) or all parameters of the displayed tab (DOWNLOAD PARAMETERS OF THIS VIEW). You can overwrite the existing parameter set in EEPROM of the CLV by choosing the "Permanent" save option. Dynamic focus control Function for shifting the focal point of the laser beam across a wide range in the reading plane. The dynamic focus control function is event controlled (e. g. by the distance detector) or dynamic in the Ö Autofocus function.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-85

Page 252

Chapter 10

Appendix

Operating Instructions CLV 490 Bar Code Scanner

Error messages Messages in Ö plain text or coded (3-digit) that are used to identify a malfunction on the CLV in Reading mode. The messages are output on the terminal interface only. Exception: ST = 3 (device error), which is also output on the host interface. The error messages can be displayed in the Terminal emulator in the "CLV-Setup" program. Error status Identifier output with the reading result by the CLV for errors that were diagnosed while the bar code was being read. The entry for the host interface is made in the "Code-Info/Separator" block of the Ö data output string and must be enabled using the parameters (for the CLV 490 disabled by default). Focus position Distance of the focal point of the emitted laser beam in front of the reading window. Can be varied using the optical components in the CLV. Creates a distance-specific depth of field (DOF) in which he bar code can be detected. Functional interfaces Switching inputs and outputs on the CLV. Good Read The CLV successfully detected a bar code or the required number of bar codes specified by the evaluation parameters during the Ö reading pulse. Header Data block in the reading result on the Ö host interface. Used as a header in the Ö data output string for the subsequent data content of the bar codes. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Header" block is empty in the default setting of the CLV 490. Host interface Main data interface on the CLV with configurable data output format. Used to output the Ö reading result in telegram form to the host/PLC. Integrates the CLV in the SICK network (RS 485) or builds a master/slave arrangement. Physically switchable to RS 232 or RS 422/ 485. It supports various transmission protocols. Increment management Used in certain applications to separate bar codes with identical contents that move during the reading procedure and assign them to the objects. Line scanner Scanner that uses a polygon mirror wheel with paraxial mirrors to deflect a focused laser beam extremely fast. As a result, it creates a light spot in the reading plane that moves along a straight line, which appears to the naked eye as a stationary scan line. Line scanner with oscillating mirror Line scanner that also deflects the laser beam about a central position, on both sides and perpendicular to the scan direction using an oscillating mirror. By doing so, the CLV can search for bar codes in larger areas. In addition to basic deflection with the maximum oscil-

10-86

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 253

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner lating amplitude, optimum oscillating mirror functions are also possible (variable deflection per distance configuration, Ö One-Shot). Master/slave configuration Special arrangement for connecting up to max. 10 SICK bar code scanners in the CAN Scanner Network to one reading station (e. g. left/right read). Thanks to the master, the entire network appears as one device to the host. Multiple read Variable number of reading operations that must provide identical reading results (data content) of the same bar code before the CLV outputs the result. No Read The CLV failed to detect a bar code or the required number of bar codes specified by the evaluation parameters during the Ö reading pulse. No Read format Special, parameterizable data block as a substitute for bar codes, which were expected but not detected, in the data output string on the host interface for Ö No Read. Comprises a variable combination of the error string and the Ö "Code-Info/Separator" block. Object height detector See distance detector. Object polling The CLV automatically detects a current object entering or leaving the reading field without any external sensors. Omnidirectional reading Arrangement of the scan lines of at least two CLVs which form a cross. Due to the max. tilt 45° of the CLV the position of a bar code to the scan lines is free. One-Shot Selective, one-off deflection of the oscillating mirror for each Ö reading pulse. Usually comprises a slow forward phase (read) and a fast return phase (return to starting position). Oscillating mirror reversal point Deflection point of the oscillating mirror at which it changes direction. Can be used to trigger a Ö focus position switchover for slower applications (search mode). Parameter set Data record used to initialize and activate the functions implemented in the CLV. With Ö downloading and Ö uploading the parameter set is transferred form CLV-Setup to the CLV or from the CLV to CLV-Setup. Parameter memory, external Optional accessory containing an integrated connector cover. Enables devices to be conveniently replaced by storing a copy of the CLV parameter set (EEPROM). The replacement device then accesses this parameter set directly and does not have to be configured manually.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-87

Page 254

Chapter 10

Appendix

Operating Instructions CLV 490 Bar Code Scanner

Percentage evaluation Special operating mode in which the quality of the reads (not those of the bar codes, however) is assessed statistically. The bar codes must be stationary. The CLV carries out 100 scans and evaluates the reading quality. It then outputs the reading results on the Ö terminal interface every 2 s together with the Ö reading diagnosis data. Plain text Legible form of a CLV message. The CLV outputs special messages in coded form, e. g. the result of the self-test is represented as three digits. Reading diagnosis data Data directly derived from the reading procedure by the CLV. This data enables the quality of the read to be assessed. The data is always output on the Ö terminal interface together with the reading result. Only output on the host interface if enabled on the DATA STRING tab in the "CLV-Setup" program (for the CLV 490 disabled by default). Reading field In start/stop mode the reading field is the area between the start and stopp sensors for the reading pulse in conveyor direction. In tracking mode the reading field is the area between the sensor for start/end of an object and the object release point (data output) (parameterized as a distance in conveyor direction), referred to the increments. Reading field height Length of the Ö scan line that is available for detecting the bar code in the reading plane. Due to the V-principle of beam generation, the reading field height is dependent on the reading distance. Reading interval Timeslot in which the CLV activates the laser diode and attempts to detect valid bar codes from the information read. The reading interval may be shorter than the external reading pulse, depending on the selected output mode for the reading result. Reading pulse Clock pulse applied externally to the CLV to trigger the internal Ö reading interval. Can be supplied by a photoelectric reflex switch or a command from the host on the serial interface. Reading range (DOF) Depth of field about the focal point of the laser beam on two sides. The extent of the reading range depends on the resolution and reading distance. Reading result Electronic representation of the data content of the read bar code together with the Ö reading diagnosis data in one Ö data output string that is generated after the reading pulse has elapsed. The reading result on the terminal interface has a fixed format (content and output format); the reading result on the host interface can be configured separately for Good Reads and No Reads. Special characters can also be added if necessary.

10-88

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 255

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner

Result status output Function of the four "Result 1" to "Result 4" switching outputs in Reading mode. Signals the status of the reading result without indicating its contents (e. g. Good Read). You can assign a status to each output on the DEVICE FUNCTION tab in CLV. The "Read Result" LED is linked to the "Result 2" output. Scan line See line scanner. Sending point Point at which the reading result is output with respect to the start of the Ö reading pulse and the internal Ö reading interval. SICK network Special, high performance network of max. 31 CLVs with high data transfer rates on the RS 485 interface. The CLVs are coordinated (polling) and connected to the host via the CLX 200 Network Controller. SMART decoder Specially developed Ö decoder for reading bar codes with an extremely small code height and for poor-quality or contaminated code prints. Specification diagrams Diagrams for reading the resolution-specific depth of field (DOF) for specific focus positions. Splitter Data block in the reading result of the Ö host interface. Used to separate the data content of the bar codes. Contains up to 5 elements, consisting of constants (control characters, letters, digits), depending on the configuration. The "Splitter" block is empty in the default setting of the CLV 490. Standard decoder Tried-and-tested Ö decoder from the CLV product family. Suitable for applications with an adequate code height, limited tilt, and high-quality code prints. Start/stop mode With this type of separate reading pulse, only one object is located in the reading field for each reading pulse. If the CLV is used in a stand-alone configuration, the start and end of the reading pulse are controlled by external sensors, command strings, or with the free running mode of the CLV. If used in conjunction with other CLVs in a master/slave arrangement including the OTC 400 (e.g. omnidirectional 2-side reading), the CLV receives the reading pulses via the OTC 400. In this case, the size of the reading field is determined by the distance between the two external sensors for starting (start of reading field) and stopping (end of reading field) the reading pulse. The minimum reading distance between two objects must always be greater than the size of the reading field. The devices are connected via the CAN interface. Storage in the CLV The application-specific Ö parameter set can be stored temporarily or permanently in the CLV. If it is stored temporarily in the RAM, it is lost as soon as the power supply is switched

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-89

Page 256

Chapter 10

Appendix

Operating Instructions CLV 490 Bar Code Scanner off. Parameter sets that are stored permanently are transferred to the EEPROM in the CLV and remain active as the current data record when the power supply is switched off. The default setting is not affected by this and is stored in a read-only memory (ROM). Switching sequence Focus control function for event-controlled switching. Sequence of focus position settings with associated depths of field. The numbers of the active Ö distance configurations are entered at the required position in the assignment table for this purpose. System messages Messages Ö in plain text used to output the operating status of the CLV. The messages are output on the terminal interface only and can be displayed in extended mode in the TERMINAL EMULATOR of the "CLV-Setup" program. Teach-in Method of programming the information required to adjust the CLV to the reading application in Parameterization mode. Example: teaching in the background for the Autofocus function, also known as a Ö distance profile. Terminal interface Auxiliary data interface (RS 232) on the CLV with fixed data output format. Used to connect the "CLV-Setup" program to the CLV so that it can operate and configure the device. Also used to output system and error messages. Can be assigned various functions. Terminator Data block in the reading result on the Ö host interface. Used to terminate the data content of the bar code. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Terminator" block is empty in the default setting of the CLV 490. Tracking mode With this type of continuous reading pulse, several objects are located consecutively in the reading field. To enable the read bar codes to be uniquely assigned to objects, a minimum gap has to be ensured between the objects and the conveyor increment signals have to be supplied. The CLV is used in conjunction with other CLVs in a network with the OTC 400 (e.g. omnidirectional 3-side reading). The CLV receives pulse signals and increment values via the OTC 400. In this case, the size of the reading field is determined by the distance between the external sensor for the start/end of the object at the start of the reading field and the object enable point (data output) of the OTC 400 in the conveyor direction at the end of the reading field. The devices are connected via the CAN interface. The CLV manages recorded objects in an internal object tracking list. Upload Method of transferring the Ö parameter set from the CLV to the PC Ö using the CLV-Setup program. CLV-Setup either transfers a complete copy of the current parameter set from the memory (RAM) of the CLV (UPLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (UPLOAD PARAMETER) or all parameters of the displayed tab (UPLOAD PARAMETERS OF THIS VIEW). Displays the current parameter values on the tabs. Prerequisite for modifying the current parameter set.

10-90

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004