Page 71
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5.5.4
Connecting the host interface
RS 232
( )=9-pin Sub D (plug )= 9-pin D-Subon PC connector at PC
RS 422
CAN-Network: Connection diagram for SICK CAN Scanner Network see "CLV Connect" program on CD-ROM Fig. 5-3:
Connecting the host interface
Risk of damage to the interface module Electrical components in the CLV may be damaged if the host interface is connected incorrectly.
Default
¾
Connect the host interface as shown in Fig. 5-3.
¾
Check the connections carefully before you switch on the CLV.
¾
Connect the host interface on the CLV to the host using shielded cables (EMC requirements). Ensure that the maximum cable lengths are not exceeded (see Table 5-21, Page 5-17).
In the default setting, the CLV communicates with the host via the host interface using the values shown in Table 5-24. Parameter
Value
Physical design
RS 422/485
Data transfer rate
9,600 bd
Data bits
8
Parity
None
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for repeat: none, timeout: 50 ms)
Table 5-24: Communication parameters for the host interface (default setting)
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-21
Page 72
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
For connecting the host interface via the CDB 420 or CDM 490 Connection Module, see the Operating Instructions for the "CDB 420 Connection Module" (no. 8 010 001, German/ English) respectively the Operating Instructions for the "CDM 490 Connection Module" (no. 8 010 005, German/English). Terminating the RS 422 interface: The interface can be terminated in the Connection Module. See the Operating Instructions for the "CDB 420 or CDM 490 Connection Modules". Activating the RS 232 interface: The RS 232 interface can be activated with the "CLV-Setup" program:
Tip
1.
Choose the HOST INTERFACE tab.
2.
Choose the RS 232 option from the HARDWARE drop-down list under DATA FORMAT.
3.
Download the data to the CLV by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is displayed.
4.
Confirm the dialog box by choosing PERMANENT. The CLV uses the RS 232 version of the host interface.
The communication parameters can be changed, if necessary, on the HOST INTERFACE tab. To do so, change the values under DATA FORMAT and INTERFACE PROTOCOL. 5.5.5
Connecting the CAN interface
Connecting the CAN Interface 1 and configuring the CLV to use the device in the SICKspecific CAN Scanner Network or in a CANopen network see the Operating Instructions “Application of the CAN interface“ (no. 8 009 180, English edition). 5.5.6
Connecting the PC
The CLV is operated and configured with the PC-based "CLV-Setup" program. In order to do so, you must connect the device to the PC via the terminal interface (auxiliary interface). Unlike the host interface, the terminal interface has a permanent data format and a fixed data transfer rate. Fig. 5-4 shows how the terminal interface is connected. The cable length should not be more than 10 m (32.8 ft).
RS 232
( ) = 9-pin Sub D plug on PC Fig. 5-4:
Connecting the terminal interface
1.
Switch off the PC and power supply to the CDB 420 or CDM 490 Connection Module.
2.
Connect the PC to the internal, 9-pin "Aux" plug on the Connection Module. To do so, use a 3-core RS 232 data cable (null modem cable), e. g. no. 2 014 054 (RxD and TxD crossed). – or – Without the SICK Connection Module: Connect the PC as shown in Fig. 5-4.
5-22
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 73
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
Tip
3.
Switch on the PC and power supply to the SICK Connection Module.
4.
Set the communication parameters (see Chapter 10.6.3 Starting CLV-Setup, Page 10-46).
In the default configuration, the terminal interface outputs the reading result in reading diagnosis mode. You can change the operating mode to MONITOR HOST INTERFACE, to MONITOR HOST INTERFACE 2, AUXILIARY INPUT or EXTERNAL DATA STRING INPUT on the AUXILARY INTERFACE tab in the "CLVSetup" program. 5.5.7
Connecting the "Sensor" switching input
If a reading procedure is to be triggered on the CLV by an external sensor, the reading pulse sensor must be connected to the "Sensor" switching input. This trigger type is selected in the default setting of the CLV. Fig. 5-5 shows the connections for the "Sensor" switching input. Table 5-25 contains the characteristic data for this input.
PNP sensor
VS
VS
1
VS
2k6
3
OUT
VS
Switch
1 3
Sensor IN GND
9
GND
5
9 GND
CLV
GND
5
VS= 18 to 30 V DC for CLV without heater, 24 V DC +20 % /–10 % for CLV with heater Fig. 5-5:
Connections of the "Sensor" switching input
¾
Connect the reading pulse sensor as shown in Fig. 5-5.
Switching mode
Current at the input starts the reading interval on the CLV. (default: active high, debouncing: 20 to 30 ms (standard))
Properties
– optodecoupled, non-interchangeable – can be connected to PNP output on a sensor
Electrical values
Low: –30 V ≤ VI ≤ +2 V
High: +7 V ≤ VI ≤ +13 V
Table 5-25: Characteristic data of the "Sensor" switching input
Tip
You can change the switching mode (polarity, debouncing, response for first pulse after power-up) of the "SENSOR" switching input on the DEVICE CONFIGURATION tab in the "CLVSetup" program. ¾
8 009 993/O824/20-12-2004
Click the READING TRIGGER PARAMETERS button. Enter the values in the dialog box displayed. Perform a download to the CLV.
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-23
Page 74
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
For connecting the switching input via the CDB 420 or CDM 490 Connection Module, see the Operating Instructions for the "CDB 420 Connection Module" (no. 8 010 001, German/ English) respectively the Operating Instructions for the "CDM 490 Connection Module" (no. 8 010 005, German/English). Note
An external pulse is not required for Percentage Evaluation mode. 5.5.8
Connecting the "IN 0" to "IN 4" switching inputs
If the Autofocus function is not used and the CLVs dynamic focus control function is to be triggered by external sensors, the sensors are connected to the five inputs "IN 0" to "IN 4". Together with the internal assignment table, these can be used to configure a maximum of 32 switching states for up to 8 distance configurations. The dynamic focus control function is selected for all inputs by default. Additional function "IN 3": The "IN 3" input can also be used as a trigger source for the One-Shot function of the oscillating mirror. Additional function "IN 4": The input "IN 4" can also be used as: •
A trigger source for the One-Shot function of the oscillating mirror
•
An input for a belt increment signal in reading mode "Tracking" and/or for separating bar codes of the same symbology with identical content
•
A trigger source for the end of reading interval
In this case, a maximum of 16 switching statuses can be used for dynamic focus control. Fig. 5-6 shows the connections for the "IN 0" to "IN 4" switching inputs. Table 5-26 shows the pin assignment on the CLV. Table 5-27 contains the characteristic data for these inputs. Table 5-28 shows the input combinations based on the distance configurations. The interaction of the switching input functions is shown in Table 5-29, Page 5-26
PNP sensor
VS
VS
1
VS
2k6
Y
OUT
VS
Switch
1 Y
IN X IN GND
9
GND
5
CLV
9 GND
GND
VS= 18 to30 V DC for CLV without heater, 24 V DC +20 % /–10 % for CLV with heater Fig. 5-6:
Pin assignment for IN X see Table 5-26
Connections of the "IN 0" to "IN 4" switching inputs
Note
5-24
5
In the CDB 420 Connection Module only the signals of the "Sensor“ and "IN 0“ switching inputs can be connected using the terminal strips.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 75
Operating Instructions
Electrical installation
Chapter 5
CLV 490 Bar Code Scanner
Input "IN X"
CLV "I/O" connection Pin Y
IN 0
Pin 6
IN 1
Pin 2
IN 2
Pin 7
IN 3
Pin 11
IN 4
Pin 12
Table 5-26: Pin assignment for "IN 0" to IN 4" switching inputs
¾
Connect the sensors as shown in Fig. 5-6.
For connecting the switching inputs via the CDB 420 or CDM 490 Connection Module, see the Operating Instructions for the "CDB 420 Connection Module" (no. 8 010 001, German/ English) respectively the Operating Instructions for the "CDM 490 Connection Module" (no. 8 010 005, German/English). Function
Switching mode Properties Electrical values
Trigger source for dynamic focus control "IN 3" alternative: – trigger source for One Shot on oscillating mirror "IN 4" alternative: – trigger source for One Shot on oscillating mirror – belt increment input – trigger source for end of reading interval Default setting "IN 3" and "IN 4": dynamic focus control Active when input energized (high) – Optodecoupled, non-interchangeable – Can be connected to PNP output on a sensor Low: –30 V ≤ VI ≤ +2 V
High: +7 V ≤ VI ≤ +13 V
Table 5-27: Characteristic data of the "IN 0" to "IN 4" switching inputs
Switching inputs Logic state1) "IN 4" to "IN 0" inputs 00000 00001 00010 00011 00100 00101 00110 00111 01000 01001 01010 01011 01100 01101 01110 01111 10000 10001 10010 10011
Assignment table index N1 N2 N3 N4 N5 N6 N7 N8 N9 N 10 N 11 N 12 N 13 N 14 N 15 N 16 N 17 N 18 N 19 N 20
Content Assignment Table Distance Config.2) Default setting Example: Photoelectric switches (bright switching) DC 1 DC 6 DC 2 DC 5 DC 3 DC 4 DC 4 DC 4 DC 5 DC 3 DC 6 DC 3 DC 7 DC 3 DC 8 DC 3 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 2 DC 8 DC 1 DC 8 DC 1 DC 8 DC 1 DC 8 DC 1
Table 5-28: Dynamic focus control: switching inputs/distance configuration assignment table
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-25
Page 76
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
Switching inputs Logic state1) "IN 4" to "IN 0" inputs 10100 10101 10110 10111 11000 11001 11010 11011 11100 11101 11110 11111
Assignment table index
Content Assignment Table Distance Config.2) Default setting Example: Photoelectric switches (bright switching)
N 21 N 22 N 23 N 24 N 25 N 26 N 27 N 28 N 29 N 30 N 31 N 32
DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8
DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1
1) 1 = energized (active); 0 = deenergized (inactive) 2) Distance configuration (DC): data record for focus position
Table 5-28: Dynamic focus control: switching inputs/distance configuration assignment table (contd.)
Parameter settings of switching inputs "IN 3"
Effects
"IN 4"
Focus control
Focus control1)
"IN 3" switches the focus position in combination with "IN 0" to "IN 2" and "IN 4"
Focus control1)
One shot
"IN 4" triggers the one shot "IN 3" switches the focus position in combination with "IN 0" to "IN 2"
Focus control1)
Increment counter
"IN 4" receives increment signals "IN 3" switches the focus position in combination with "IN 0" to "IN 2"
Focus control1)
End of reading interval
"IN 4" triggers the end of reading interval "IN 3" switches the focus position in combination with "IN 0" to "IN 2"
One shot
Focus control1)
"IN 0" to "IN 2" switch the focus position "IN 3" triggers the one shot "IN 4" has no effect
One shot
One shot
"IN 4" triggers the one shot "IN 0" to "IN 2" switch the focus position "IN 3" has no effect
One shot
Increment counter
"IN 0" to "IN 2" switch the focus position "IN 3" triggers the one shot "IN 4" receives increment signals
One shot
End of reading interval
"IN 0" to "IN 2" switch the focus position "IN 3" triggers the one shot "IN 4" triggers the end of reading interval
1)
1) depending on the assignment table
Table 5-29: Combination of the functions of the "IN 0" to "IN 4" switching inputs
Tip
The function assigned to the "IN 3" and "IN 4" input can be modified on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. ¾
5-26
Click the FUNCTION IN 3 and FUNCTION IN 4 drop-down list and choose the required function. Perform a download to the CLV.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 77
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5.5.9
Connecting the "Result 1" to "Result 4" switching outputs
The four switching outputs can be assigned different functions for outputting result statuses independently of each other. If the assigned event occurs during the reading procedure, the corresponding switching output becomes live at the end of the reading pulse for the selected pulse duration. The pulse duration can be set individually for each output. The "Read Result" LED is linked to the "Result 2" output and lights up in Reading mode for the selected pulse duration and function of the result status display (default: Good Read, 100 ms). Fig. 5-7 shows the connections for the "Result 1" to "Result 4" switching outputs. Table 5-30 shows the pin assignment on the CLV. Table 5-31 contains the characteristic data for these outputs. The four outputs have the same characteristic data.
VS
Fuse
Logic
Result X Y Temperature sensor
GND
5
VS= 18 to 30 V DC for CLV without heater, 24 V DC +20 %/–10 % for CLV with heater Fig. 5-7:
RL
Pulse duration depending on setting: – 10 ms to 900 ms – 100 ms to 9,900 ms – 00: static (to the end of next reading pulse) Pin assignment for "Result X" see Table 5-30
Connections of the "Result 1" to "Result 4" switching outputs
Output "Result X"
CLV "I/O" connection Pin Y
Result 1
Pin 4
Result 2
Pin 8
Result 3
Pin 10
Result 4
Pin 15
Table 5-30: Pin assignment for "Result 1" to "Result 4" switching outputs
¾ Note
Connect the outputs as shown in Fig. 5-7.
In the CDB 420 Connection Module only the signals of the "Result 1“ and "Result 2“ switching outputs can be connected using the terminal strips. "
Switching mode
PNP-switching with respect to the supply voltage VS
Properties
The current in the event of a short-circuit is limited to 0.7 A
Function assignment (default)
"Result 1": Device Ready (static), polarity: not inverted "Result 2": Good Read (100 ms), polarity: not inverted "Result 3": No Ready (100 ms), polarity: not inverted "Result 4": Match 1 (100 ms), polarity: not inverted
Electrical values
0 V ≤ VO ≤ 30 V I0 ≤ 100 mA
Guaranteed: VO ≤ VS ≤ 1.3 V with I0 ≤ 100 mA
Table 5-31: Characteristic data of the "Result 1" to "Result 4" switching outputs
Note
8 009 993/O824/20-12-2004
If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode.
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-27
Page 78
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
For connecting the switching outputs via the CDB 420 or CDM 490 Connection Module, see the Operating Instructions for the "CDB 420 Connection Module" (no. 8 010 001, German/ English) respectively the Operating Instructions for the "CDM 490 Connection Module" (no. 8 010 005, German/English). Tip
Recommendation
5-28
The output function, pulse duration (timer), and polarity of the signals can be changed on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. ¾
Click the RESULT OUTPUTS Parameter button. Enter the values in the dialog box displayed. Perform a download to the CLV.
¾
To check the switching functions using a high-impedance digital voltmeter, connect a load to the outputs to prevent incorrect voltage values/switching statuses from being displayed.