The text of a manual · part 9 of 30

Operating Instructions: CLV490 Bar Code Scanner, Advanced Line: 6 Operation, pages 79 to 87

Pages 79 to 87 of 266, from Operating Instructions: CLV490 Bar Code Scanner, Advanced Line

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV490

Page 79

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

6

Operation 6.1

Overview of steps for starting up the CLV

•

Start up the CLV with the factory default settings (quick start). With this configuration, the CLV can be operated without being connected to a PC.

•

Connect the PC. See Chapter 5.5.6 Connecting the PC, Page 5-22 and Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-43.

•

Configure (parameterize) the CLV for the application.

6.2

Default settings

Table 6-1, Page 6-2 and Table 6-2 contain an overview of the factory default settings for the CLV. The default parameters are such that the CLV can be put into operation either straight away or following a few minor adjustments. A PC does not need to be connected to start up the CLV with the default settings. The default settings are stored permanently both in the ROM of the CLV and in the CLVSetup database. They can be loaded to the RAM of the CLV at any time and displayed in the tabs of the "CLV-Setup" program. Displaying and printing out a complete set of default settings in CLV-Setup: 1.

To save the current settings in the parameter set: Choose FILE and SAVE AS, and enter a file name in the dialog box that appears. CLVSetup saves the current settings in a configuration file with the extension "*.scl".

2.

Click in the toolbar. CLV-Setup loads the default settings from its internal database and displays them in the tabs.

3.

Click in the toolbar. The PRINT FILE dialog box is displayed.

4.

If desired, a comment can be entered in the input field for the header of the printout. Confirm the entry with OK. The PRINT dialog box for configuring the printer then is displayed.

5.

Make the appropriate entries in the dialog box and confirm these with OK.

CLV-Setup prints out the complete set of default settings in the form of a table. The header contains the company and user names that were entered during the CLV-Setup installation routine.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-1

Page 80

Operation

Chapter 6

Operating Instructions CLV 490 Bar Code Scanner

6.2.1

Default settings of the line scanner CLV 490 (all variants)

Parameter

Default setting

Decoder

SMART/standard

Active codes types

Code 39, 2/5 Interleaved, Code 128

Code length

Freely assignable (2/5 Interleaved: interval 4 to 50 characters)

Start/stop ratio

Automatic

Min./max. code position

5/ 95 CP

No. of multiple reads

3

Min./max. no. codes

1

Scanning frequency

800 Hz

Distance measurement

Active

Background

Default (2,200 mm (86.7 in) along entire distance profile)

Autofocus mode

Min. distance

Range

400 to 2,200 mm (15.8 to 86.7 in)

Scan angle

–27° to +27°

Focus control trigger

Autofocus, switchover immediately (synchronously)

Reading pulse source

Start: "Sensor" switching input (active: high); end: "Sensor" switching input

"IN 0"to "IN 4" switching inputs

Focus position changeover (without meaning for autofocus function)

"Sensor" switching input

Start and end of reading pulse (level: active high), debouncing 20 to 30 ms

Switching outputs Status output function

Not inverted; pulse duration: 100 ms Result 1: Device Ready (static); Result 2: Good Read; Result 3: No Read; Result 4: Match 1

CLV arrangement

Stand-alone

Read result output

Host interface

Device number

1

Start option

Load the parameter set of the external parameter memory

Host interface (type)

RS 422/485

Protocol

NAK; start character: STX, stop character: ETX

Transmission rate

9 600 bd

Data format

8 data bits, no parity, 1 stop bit

Output format

Good Read: Header: blank, Code Info/Separator: blank, Splitter: blank, Terminator: blank Reading data on No Read: output: yes, contents: Code Info/Separator and Error string Error string: NOREAD

Output sorting

In accordance with code position

Output time

Read result: end of the read interval

Test string Terminal interface Function Table 6-1:

Code Info/Separator: after code

Not activated RS 232, 9 600 bd, 8 data bits, no parity, 1 stop bit (values cannot be changed) Reading diagnosis

Extract: Default parameter settings of the line scanner CLV 490-0010/-0011

6.2.2

Default settings of the line scanner with oscillating mirror CLV 490 (all variants)

Default settings as for line scanner CLV 490, but with the following additional parameters: Parameter

Default setting

Oscillating amplitude

±40 CW (corresponds to an angle of deflection of –20° to +20°)

Operating mode

Oscillating with fixed amplitude, mode independent of reading pulse trigger

Oscillating frequency

1 Hz

Fixed position

50 CW (corresponds to an angle of deflection of 105°)

Table 6-2:

6-2

Extract: Default parameter settings of the line scanner with oscillating mirror CLV 490

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 81

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

6.3

Quick start

A PC need not be connected when the CLV is operated with the factory default settings. Code 39, 2/5 Interleaved, and Code 128 are the default code types enabled (free code lenght, 2/5 Interleaved: interval 4 to 50 characters). 6.3.1

Starting up the CLV with the factory default settings

1.

Connect the CLV as followed: CDB 420 Connection Module: use the cable no. 2 027 046 (connector cover, IP 65). Alternatively, connect the CLV via the cable no. 2 030 023 (connector cover with external parameter memory, IP 65). CDM 490 Connection Module: use two cables no. 2 020 302. Alternatively, connect the CLV via the cable no. 2 020 307 (connector cover with external parameter memory, IP 65).

2.

Connect the reading pulse sensor (e. g. photoelectric reflex switch) to the "Sensor (1)" switching input of the CLV via the CDB 420 or CDM 490 (see Chapter 5.5.7 Connecting the "Sensor" switching input, Page 5-23).

3.

Switch on the power supply of the CDB 420 or CDM 490. The CLV starts. The "Device Ready" LED lights up. The "Result 1" ("Device Ready") output switches. CLV with external parameter memory in the connector cover connected : If no CMC 400 parameter memory module is available in the CDB 420 or CDM 490 Connection Module the CLV will operated as followed: If an external parameter memory in the connector cover containing a corresponding parameter set is connected to the CLV, the "Device Ready" LED blinks for 10 s when the device starts up correctly and then lights up constantly. If the external parameter memory in the connector cover is empty, the CLV copies its parameter set to the external parameter memory. Then the "Device Ready" LED lights up. The CLV is ready for operation. If a CMC 400 is available in the CDB 420 or CDM 490 the CLV cancels the function of the external parameter memory in the connector cover. The CLV supports the CMC 400 from firmware V 3.30 on. Line scanner with oscillating mirror: In the default setting, the CLV deflects the scan line around the position CW = 50 with a frequency of 1 Hz and an oscillating amplitude of ±20° (±40 CW). 50 CW correspond to a deflection angle below 105°.

8 009 993/O824/20-12-2004

4.

Start the reading pulse: block the light path of the photoelectric switch or close the switch. The "Sensor" LED lights up. The CLV switches the laser diode on and the red scan line appears.

5.

Present the bar code pattern (Fig. 6-1, Page 6-4) to the CLV at the reading distance specified in Table 6-3. The scan line must not hit any object in a distance closer to the CLV than the represented bar code (default setting: autofocus mode "Minimum distance").

6.

Align the bar code in such a way that the red scan line is almost at a 90° angle to the bars (line scanner) or that the red scan line sweeps the bars at a 90° angle when it is deflected (oscillating mirror).

7.

End the reading pulse: unblock the light path of the photoelectric switch or open the switch. The "Sensor" LED is extinguished. The CLV switches the laser diode off. The CLV confirms that the bar code was read successfully (the "Read Result" LED lights up for 100 ms). The "Result 2" ("Good Read") output is switched for a duration of 100 ms.

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-3

Page 82

Chapter 6

Operation

Operating Instructions CLV 490 Bar Code Scanner

The CLV can now be operated with the factory default settings. The device can be switched off without the configuration data being lost as no changes have been made to the parameter set.

0

Fig. 6-1:

2

3

4

1

2

3

4

5

Bar code pattern (Code 39; module width 0.35 mm (11.8 mil); Print ratio 2:1)

Device type

Scanning method

Reading distance

CLV 490 (all variants)

Line scanner approx. 1,000 mm (39.4 in)

CLV 490 (all variants)

Line scanner with oscillating mirror approx. 1,000 mm (39.4 in)

Table 6-3:

6-4

1

Reading distances for default settings

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 83

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

6.4

Configuring (parameterization) the CLV

The CLV adapts to the reading situation locally with the configuration. The read, evaluation and output characteristics can, therefore, be parameterized as required on the basis of the factory default settings or an application-specific CLV parameter set that has already been created. The CLV supports two different configuration methods: •

Configuration via the "CLV-Setup" program (parameter values are set via the serial interface)

•

Configuration via command strings (parameter values are set via the serial interface). See Chapter 10.7 Configuring a CLV with command strings, Page 10-53.

In the Parameterization mode, the CLV outputs no reading result. 6.4.1

Configuring the CLV via the user interface of CLV-Setup

To be able to use CLV-Setup, a PC has to be connected and the program installed on it. The procedure for connecting the PC to the CLV is described in Chapter 5.5.6 Connecting the PC, Page 5-22. The procedures for installing and starting the "CLV-Setup" program and for starting and operating the user interface are described in the Appendix (Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-43). Transferring a parameter set between CLV-Setup and the CLV Upload When the CLV is being parameterized, CLV-Setup runs in the offline mode. To be able to modify the current parameter set of the CLV, this first has to be loaded to CLV-Setup from the CLV. This procedure is referred to as an upload ("Upload from CLV" in the CLV 490 menu or [F3] key) during which CLV-Setup always loads a complete copy of the current CLV parameter set. This parameter set remains unchanged until it is overwritten by CLV-Setup. With the help of the context menu (right mouse button), only the parameter just edited can be loaded ("Upload parameter") or from version 3.6 all parameters of one tab or one dialog box ("Upload parameters of this view") from the CLV’s memory (RAM). Download Changes made to the current parameter set in CLV-Setup do not take effect until the parameter set has been transferred to the CLV. CLV-Setup always sends a copy of the complete parameter set to the CLV, i. e. all of the existing parameter values in the CLV are overwritten. The procedure for transferring and saving the parameter values in the CLV is referred to as a download ("Download to CLV" in the CLV 490 menu or [F4] key). With the help of the context menu (right mouse button), only the parameter just edited ("Download parameter") or from version 3.6 all parameters of one tab or one dialog box ("Download parameters of this view") will be temporarily loaded into the CLV’s memory (RAM). To finish the parametrization done by this way all parameters must be download again to the CLV with the "Permanent" option. Loading a complete CLV parameter set (upload) ¾

8 009 993/O824/20-12-2004

Click in the toolbar or press [F3] key. CLV-Setup loads the current CLV parameter set from the RAM of the CLV to its database and displays the values in the tabs. The "Device Ready" LED is extinguished during the upload.

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-5

Page 84

Chapter 6

Operation

Operating Instructions CLV 490 Bar Code Scanner

If the "CLV-Setup" program does not recognize parameters transferred during the upload, it outputs a warning message. Unknown parameters can be edited in the EXTRAS tab by following the conventions for command strings. When the parameter set is then saved, these parameters are also saved. Transferring and saving a complete CLV parameter set (download) 1.

Click in the toolbar or press [F4] key. The "Device Ready" LED is extinguished. CLV-Setup copies the parameter set to the RAM of the CLV. The DOWNLOAD PARAMETERS dialog box with the storage options is then displayed. PERMANENT: CLV-Setup copies the parameter record to the RAM and to the EEPROM of the CLV. TEMPORARY: CLV-Setup copies the parameter record to the RAM only. The changes are lost when the CLV supply voltage is switched off.

2.

Confirm the dialog box with the desired storage option. The "Device Ready" LED lights up again.

The new parameter set is stored in the CLV either permanently or temporarily dependent of the selected option. CLV with external parameter memory If the parameter set was downloaded and stored permanently, CLV-Setup opens a further dialog box for adjusting the parameter set in the external memory, if the start option is set to START WITH EXTERNAL PARAMETERS. ¾

Choose the COPY NOW INTERNAL PARAMETER SET TO EXTERNAL MEMORY option. CLV-Setup then instructs the CLV to copy the new parameter set to the external memory. The "Device Ready" LED lights up again.

The internal and external parameter sets are now identical. See also Chapter 10.3.5 Adjusting the parameter set in the external parameter memory (connector cover) after it has been downloaded to the CLV, Page 10-37. Saving the parameter set in CLV-Setup 1.

To save the modified parameter set as a new configuration file in CLV-Setup, or to overwrite an existing file, choose FILE and SAVE AS. The SAVE AS ... dialog box is then displayed.

2.

Enter the file name in the dialog box (file name extension "*.scl") and confirm the entry.

The new parameter set is now stored in CLV-Setup in the subdirectory "data".

6-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 85

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

6.4.2

Function of the tabs in CLV-Setup (overview)

Reading Configuration This tab and further dialog boxes are used to set the following: •

Scanning frequency

•

Start/stop ratio

•

Reading area (CP limits or three-dimensional reading space when the conveyor is running)

•

Autofocus mode (distance measurement, preference focus distance, delay of focus change, depth of field optimization, autofocus space, delimitations, extent of deflection)

•

Reading distance configurations for event-controlled focus control (focus position, evaluation range of the scan line, assignment table)

•

Trigger source for the focus control

•

Adjustment to bar code quality caracteristics, background (scattered print) and relative module width

Device Configuration This tab and further dialog boxes are used to set the following: •

Device number

•

Source of the Reading trigger mode

•

Laser timeout

•

Output time of the Reading result referred to the start of the reading interval

•

Scanner position parameters (the position of the CLV in the area)

•

Tracking parameters

•

Object polling parameters

•

Output filter of the reading result (host interface)

•

Physical arrangement for data output via the host interface (stand-alone, master/slave)

•

Functional assignment of the "IN 3" and "IN 4" switching inputs

•

Functional assignments of the "Result 1" to "Result 4" switching outputs

•

Start option for accessing the parameter set

•

Code position comparison

Code Configuration This tab and further dialog boxes are used to set the following:

Recommendation

8 009 993/O824/20-12-2004

•

Type of active decoder (SMART and/or standard decoder)

•

Evaluation routines for individual code types

•

Number of identical reads (multiple reads)

•

Minimum and maximum number of bar codes to be read/output

•

Start/Stop recognition mode

•

Activation of the comparison of the code position for the separation of identical bar codes

•

Special parameters of the SMART decoder (e. g. for OTS mode)

To enhance the reading reliability with fast applications, only activate those code types and code lengths that are actually relevant.

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-7

Page 86

Chapter 6

Operation

Operating Instructions CLV 490 Bar Code Scanner

Host Interface This tab and further dialog boxes are used to set the following: •

Destination of the read result date strings (host interface or CAN interface)

•

Active physical interface (RS 422/485 or RS 232)

•

Data format and transmission rate

•

Data transmission protocol

•

Start and stop characters of the interface protocol

Data Strings This tab and further dialog boxes are used to set the following: •

Data output format of the host interface (telegram format)

•

Constants and reading diagnosis data in the "Header", "Code info/separator", "Splitter" and "Terminator" blocks

•

Arrangement of the "Code info/separator" blocks in the data string

•

Output format for no reads and contents of the error string

•

Test string function

•

Output sequence and sort criteria for reading more than one bar code per reading pulse

•

Format mask and its structure

•

Output format of an external data string forwarded as reading result

Auxiliary Interface This tab and further dialog boxes are used to change the following: •

Operating mode of the terminal interface

CAN Interface This tab and the further dialog windows are used to change the following: •

CAN interface operating mode

•

Data transfer rate

•

Type of logical data connection of the connected CLV

•

Usage of the switch inputs/outputs of the CLV as CANopen Digital I/O

Oscillating Mirror This tab is used to set the following: •

Operating mode of the oscillating mirror

•

Oscillating frequency

•

Angle of deflection (oscillating amplitude)

•

Start of oscillating mode

•

Trigger source for One-Shot

Fieldbus Gateway This tab (and additional dialog boxes) are used to set the following:

6-8

•

Data interface of the CLV to be connected to the gateway in the CDM 420

•

Type of fieldbus

•

Special fieldbus parameters

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 87

Operation

Operating Instructions

Chapter 6

CLV 490 Bar Code Scanner

Extras This tab is used to edit parameters that were not recognized by CLV-Setup after an upload. Note

CLV-Setup Online Help contains a detailed description of the functions of the parameters and their valid entries (see Chapter 10.6.8 Online help – CLV-Setup Help, Page 10-50 for calling up Help). 6.4.3

Parameterizing example

For a simple application in start/stop mode, Chapter 10.10 Discussion of a parameterization example, Page 10-60 in the appendix shows an example of the recommended procedure when parameterizing the CLV. Otherwise, the general guidelines in the next chapter provide orientation during adaptation to the individual reading situation. 6.4.4

Guide to parameterization menu

Overview of parameterization steps • a) Configuring the reading area

• b) Selecting the focus control mode

• c) Configuring the focus control

• d) Adjusting the optical read properties of the scanner

• e) Optional: configuring the oscillating mirror functions

• f) Configuring the reading mode

• g) Adjusting the laser timeout

• h) Adjusting the decoder’s evaluation properties

• i) Adjusting the output properties (data, result status)

• j) Specifying the terminal interface function (auxiliary interface)

• k) Configuring the source of the parameter set for starting up (only with external parameter memory)

When the CLV is switched on for the first time, it is started with the factory default settings. The following parameters must then be set:

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-9