For the Sick CLV490
Page 88
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner a)Parameterizing reading area Irrespective of the type of focus control, the reading area defines the area along the scan line in which the CLV always evaluates bar codes. In combination with the multiple focus position switchover/autofocus, this produces a vertical plane relative to the CLV (or a tunnel in the case of object tracking in conveyor mode). During evaluation, the CLV rejects any bar codes detected outside the defined area. Condition: reading from above with line scanner •
CP limits: Simple delimitation of the reading area (circle segment) by restricting the active scan angle range without reference to a point of origin (Fig. 6-2). The scan angle range is max. ±30° for a line scanner and max. ±25° for a line scanner with oscillating mirror.
•
Reading space: Sharp delimitation of the active reading area by defining the area through which the object must pass in the circle segment. This produces a rectangular reading space with reference to a point of origin. For use in conveyor systems where the conveyor belts are very close to each other and the scan line partly extends over adjacent belts because the CLV is installed above the belt. The position of the CLV in relation to the defined reading space and the point of origin must also be parameterized (scanner position and angular position).
CP limits
Fig. 6-2:
Note
6-10
Reading space:
Narrowing the reading space using limit values
In the case of the line scanner with oscillating mirror, the active deflection range of the oscillating mirror can also be restricted (CW value).
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 89
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
Define CP limitations – and/or –
Ö READING CONFIGURATION tab Ö READING AREA section Ö CP-LIMITS Ö DISTANCE CONFIGURATION button Ö DISTANCE CONFIGURATION tab – configuration 1: Minimum CP and Maximum CP Oscillating mirror: – additionally: Oscillating mirror amplitude CW
Define reading space
Ö READING AREA section Ö READING AREA Ö READING SPACE PARAMETERS button – Right edge of conveyor (Y 1) – Left edge of conveyor (Y 2) – Level of conveyor (Z 1) – Maximum scanning height (Z 2) Define the CLV position referred to the reading space (point of origin):
Ö DEVICE CONFIGURATION tab Ö SCANNER POSITION PARAMETERS button Ö ANGLES – alpha, beta and gamma Ö COORDINATES – x-, y- and z-coordinates Table 6-4:
Note
Recommendation
Guide: Configuring the reading area
The minimum and maximum values for the active evaluation range of the scan line (CP limits) can be checked in the SHOW CP-LIMITS mode. See also Chapter 6.5.5 Show CP-limits, Page 6-47. Don’t configure the reading space if you use the free running mode in combination with a fixed focus position (fix focus mode). Restrict the reading space using the CP-limits. b) Selecting focus control mode •
Autofocus: Using the periodic distance measurement function, the CLV creates an up-to-date distance profile in its area of view with every 10th scan. From this profile, the CLV uses the selected autofocus mode, the parameterized limits of the autofocus area, and the taught-in background (optional) to automatically determine the required focus position for a detected object. The defined autofocus area should be within the limits of the parameterized reading area.
•
Event-controlled focus control: The CLV controls its focus position by means of distance information, which it receives either externally via the switching inputs (reading from above: object height detection by means of photoelectric switches) and their assignment to parameterized distance configurations, or by means of command strings via the serial data interface (also with reference to distance configurations). In timer mode (search), the CLV changes its focus position step by step according to the parameterized number and sequence of distance configurations. The line scanner with oscillating mirror also uses – similar to the timer mode – its oscillating mirror reversal points at the maximum deflection points to trigger the switchover.
The time at which focusing occurs relative to the reading pulse can be selected for both types of focus control.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-11
Page 90
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
Activate autofocus – or –
Ö READING CONFIGURATION tab Ö FOCUS CONTROL section
Activate focus position switchover (event-controlled) (selecting trigger source)
Ö READING CONFIGURATION tab Ö FOCUS CONTROL section
– Autofocus
Table 6-5:
– Inputs/Serial or – Timer Ö TIMER or – Static/No trigger Oscillating mirror: – additionally: Oscillating mirror extrema
Guide: Selecting the focus control mode c) Parameterizing focus control Autofocus Condition: Reading from above
Explanation
•
Minimum distance: Relative to its surroundings, the object is always located at the shortest distance from the CLV. Example: object positioned directly on the conveyor belt without a container (tray, etc.) or interfering side boundaries Condition: only one object in the reading field during the reading interval.
•
Differential background: The background can be closer to the CLV than the object. Example: object in a container on the conveyor belt; the container wall is higher than the object (closer to the CLV). Condition: only one object in the reading field during the reading interval.
•
Differential background and tracking: Same as the "Differential background" function, except that in each reading pulse more than one object can be located in the reading field at the same time. On the basis of the detected distances, the CLV assigns the required focus positions in its internal focus list to the objects and organizes the objects using a continuous increment in its object list. In this way, scanned bar-code information can be uniquely assigned to the individual objects. This is only available in the reading mode "Tracking" (internal tracking or reading mode "OTS trigger"), not in "Object polling" mode (one object only) of start/stop mode. For more detailed information, see also Chapter A2. Tracking mode (controlled by Increment), Page 6-28.
Background teach-in: For autofocus modes "Differential background" and "Differential background and tracking", the CLV can also teach in the ambient background in its area of view (e.g. if interfering objects in the conveyor system project into the defined autofocus area) in order to improve the evaluation of the current distance profile. When doing so, the CLV adjusts – among other things – the measured background by 100 mm (3.9 in) in its direction to compensate any measurement inaccuracies. The default background at a distance of 2,200 mm (86.7 in) is used in all other cases and, if necessary, the autofocus area is limited by means of the appropriate parameters. In this case, CLV measurement inaccuracies must be taken into account when the rectangular autofocus space is defined (see note „Distance measurement“, page 6-16).
6-12
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 91
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Oscillating mirror: When the background is being taught in, the behavior of the oscillating mirror depends on the selected mode (see Chapter 6.5.4 Background teach-in, Page 6-45). Action
Settings in CLV-Setup
1. Select autofocus mode
Ö READING CONFIGURATION tab Ö AUTOFOCUS section Ö MODE – Minimum distance See also overview in Table 6-7, Page 6-15.
Ö MODE
– or –
– Differential background Define the scanner position referred to the conveyor belt: see Table 6-4, Page 6-11, reading space, scanner position Limit autofocus area: Define limit values and /or a rectangular autofocus area. Optionally teach in the background.
Ö Limit values and autofocus space: see 2. „Configure autofocus“, AUTO FOCUS LIMITS tab
Ö Teach in the background: see 3. „Teach-in background (optional)“ See also overview in Table 6-7, Page 6-15.
Ö MODE
– or –
– Differential background and tracking Define the scanner position referred to the conveyor belt: see Table 6-4, Page 6-11, reading space, scanner position Limit autofocus area: Define limit values and /or a rectangular autofocus area. Optionally teach in the background.
Ö Limit values and autofocus space: see 2. „Configure autofocus“, AUTO FOCUS LIMITS tab
Ö Teach in the background: see 3. „Teach-in background (optional)“ See also overview in Table 6-7, Page 6-15. 2. Configure autofocus
Ö AUTOFOCUS PARAMETERS button Ö AUTOFOCUS PARAMETERS tab Ö AUTOFOCUS PREFERENCES tab – Default focus distance1) (default setting)
Ö AUTOFOCUS LIMITS PARAMETERS button Ö AUTOFOCUS LIMITATION section – Min. and max. value
Ö SCAN ANGLE LIMITATION section – Min. and max. value Oscillating mirror: Ö additionally: OSCILLATING ANGLE LIMITATION section – Min. and max. value 1) Typical for reading from above. The focus position is located slightly above the smallest object. In this way, if the CLV is mounted with its reading window opposite the conveying direction, it can continuously adjust (raise) the focus position on the front of approaching objects that are larger than the smallest object.
Table 6-6:
8 009 993/O824/20-12-2004
Guide: Configuring the autofocus function (part 1)
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-13
Page 92
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
2. Configure autofocus
Additionally for autofocus mode "Differential background“ ’ and „Differential background and tracking“: Ö AUTOFOCUS SPACE section – Right edge of conveyor (Y 1) – Left edge of conveyor (Y 2) – Level of conveyor (Z 1) – Maximum scanning height (Z 2)
Ö AUTOFOCUS OPTIMIZATION PARAMETERS button Ö DELAY OF FOCUS CHANGE section – Timeout – Hysteresis Ö DEPTH OF FIELD OPTIMIZATION section – Offset at minimum – Offset at maximum Ö "Distance measurement" section (default setting) – active – Source of distance information: internal/external – Smooth filter: active, length 3 3. Teach-in background (optional)
For autofocus mode "Differential background“ and „Differential background and tracking“:
Ö Menu CLV 490 Ö DEVICE FUNCTIONS Ö Background – Teach-in Check taught-in background: Ö READING CONFIGURATION tab Ö AUTOFOCUS section Ö SHOW BACKGROUND2) button Displaying online the actual background profile with focus level points: Ö Menu CLV 490 Ö BACKGROUND ANALYSIS – Analysis: Autofocus 4. Select focus position switchover (refered to the start of the reading interval)
Ö READING CONFIGURATION tab Ö FOCUS CONTROL section Ö INPUTS/SERIAL/AUTOFOCUS – immediate or synchronous (default setting) or – latched
2) The CLV displays the taught-in background with the internal correction of 100 mm (3.9 in) but not the parameterized limits of the autofocus space.
Table 6-6:
Note
6-14
Guide: Configuring the autofocus function (part 1) (contd.)
At a scanning frequency of 1,000 Hz, the typical response time for focus adjustment is 20 ms, or 30 ms if the entire range (between min. and max. focus position) is traversed. The CLV does not switch over the focus until the defined timeout has elapsed and the new focus position exceeds the parameterized hysteresis value relative to the old focus position. If the new focus position is within the hysteresis, the CLV does not switch over the focus. Depth-of-field optimization with respect to the object and the purpose of depth-of-field optimization are described in Chapter 3.2.1 Autofocus function, Page 3-7.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 93
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
Overview: Autofocus functions Parameter
Autofocus mode Minimum distance
Differential background
Condition
Only one object in the reading field during reading interval
Only one object in the reading Serveral objects in the reading field during reading interval field during reading interval
1. Limitation values: autofocus limitation
✖
❍
❍
2. Limitation values: scan angle limitation
✖
❍
❍
Oscillating mirror: 3. Limitation values: oscillating angle limitation
✖
✖
✖
4. Limitation values: autofocus space
–
❍
❍
5. Teach-in background
–
❍
❍
6. Scanner position parameters: angle alpha, beta, gamma
–
✖
✖
7. Scanner position parameters: coordinates x, y, z
–
✖
✖
8. Tracking: – Configure the mode (OTS trigger or internal tracking)
–
✖
9. Tracking parameters: Focus release point
–
–
✖
10.More than on bar code – per object: Min. and max. number of codes
–
✖
✖: required Table 6-7:
❍: optional
Differential background and tracking
–: not required
Configuring the autofocus function (part 2)
Fig. 6-3 shows a 3D example of how the autofocus area of the CLV is adjusted using the parameters "Limit values: scan angle limitation" and "Limit value: autofocus space". Note
If the required focus positions determined by the CLV are outside the defined autofocus area limits, the focus positions are not switched over (not even to the limit values). Scan angle limitation
Fig. 6-3:
8 009 993/O824/20-12-2004
Autofocus space
Result: Autofocus area
Narrowing the autofocus range using limit values
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-15
Page 94
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Event-controlled focus position switchover (alternative) Event-controlled focus position switchover can be used if the autofocus function does not provide the expected accuracy for the application. Event-controlled focus position switchover is required in the following cases, for example: •
Conveyed material with a black surface (e.g. vehicle tires) The laser light emitted by the CLV is absorbed by the surface of the material, which means that the distance measurement may no longer be sufficiently accurate.
•
Conveyed material with highly reflective surfaces (e.g. anti-static bags)
•
Conveyed material with bar codes on the front edge in the conveying direction. At high conveyor speeds, the CLV can no longer adjust the focus in time. Action
Settings in CLV-Setup
1. Set up distance configurations
Ö READING CONFIGURATION tab Ö READING AREA section Ö DISTANCE CONFIGURATION button Ö DISTANCE CONFIGURATION tab – Focus position Oscillating mirror: – additionally: Oscillating mirror amplitude CW Ö ASSIGNEMENT TABLE tab – Index – Valid configurations To restrict the reading area for all valid distance configurations proceed as described in Table 6-4, Page 6-11, CP limits
2. Select focus position switchover (refered to the start of the reading interval)
Ö READING CONFIGURATION tab Ö FOCUS CONTROL sections Ö INPUTS/SERIAL/AUTOFOCUS – immediate or synchronous (default setting) or – latched (special application)
3. INPUTS/SERIAL trigger source: select function for "IN 3" and "IN 4" switching inputs
Ö DEVICE CONFIGURATION tab Ö ASSIGNMENT OF INPUTS section Ö IN 3 – Focus control
Ö IN 4 – Focus control Table 6-8:
Explanation
Guide: Configuring focus position switchover
Distance measurement The distance measurement carried out by the CLV is independent of the focus control type. It is used for automatic focus adjustment in autofocus mode and for determining the code distance. For the distance measurement, the CLV determines a distance value for each scan angle between –30° and +30° (line scanner) or between –25° and +25° (line scanner with oscillating mirror). These distance values are used to create an up-to-date distance profile between the min. and max. scan angle. Once mean value calculation has been carried out, the distance profile is available after every 10th scan (e.g. every 10 ms at a scanning frequency of 1,000 Hz). The distance measurement is carried out inside the limits of 400 to 2,200 mm (15.8 to 86.7 in). If an object is being conveyed, the CLV determines (with reading from above) an average object profile according to the conveyor speed. At 1,000 Hz and a speed of 2 m/s (6.6 ft/s), this occurs over a path of 20 mm (0.79 in) for each object. The angular resolution of the periodic distance measurement is 1.5° in the scanning direction without an active median filter, and the typical distance measurement uncertainty
6-16
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 95
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner is ±50 mm (1.97 in). The median filter smoothes the values in the distance profile. An excessively high filter value reduces the angular resolution of the CLV: at the maximum reading distance, it may no longer be able to detect small objects or parts of objects. The minimum object width at the maximum focus position is the key factor for determining the filter length setting. The required reflectance of the objects is at least 12% in the measurement range from 700 to 1,300 mm (27.6 to 51.2 in) and at least 20% in the measurement range from 400 to 2,000 mm (15.8 to 86.7 in). The CLV references the distance measurement with every reading pulse (in every search interval with the "Object polling" reading pulse mode). With reading pauses > 6 minutes, the CLV carries out referencing at regular intervals. To do so, it switches on the laser diode for max. 10 seconds. The autofocus function requires active distance measurement, although this is not a requirement for event-controlled focus position switchover. In this case, however, the CLV can output the actual code distance instead of the current focus position in the "Code Info/ Separator" block. The CLV measures the code distance in the area between the start and stop character of a detected bar code and checks the distance against the parameterized autofocus limits (the autofocus limit is output if the parameterized limits are violated). If the distance measurement function is deactivated, the CLV first sets the parameterized preferred focus position. d) Parameterizing optical reading characteristics
8 009 993/O824/20-12-2004
•
Scanning frequency Ö READING CONFIGURATION tab Ö READING PARAMETERS section
•
Blank zone Ö READING CONFIGURATION tab Ö READING PARAMETERS/START/STOP RATIO section
•
Poor quality bar code print (e.g. small contrast or scattered print) Ö READING CONFIGURATION tab Ö CODE LABEL/BACKGROUND CHARACTERISTCS section
•
If reading bar codes with small height (bar lenght) using the SMART decoder Ö CODE CONFIGURATION tab Ö DECODER section/SMART PARAMETERS button
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-17
Page 96
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner e) Parameterizing oscillation mirror functions (optional) Action
Settings in CLV-Setup
1. Choose "Oscillating with fixed amplitude" mode (identical amplitude for all distance configurations with event-controlled focus control)
Ö OSCILLATING MIRROR tab Ö OSCILLATING MIRROR section – Oscillating with fixed amplitude
Ö OSCILLATING section – Frequency
– or – 2. Choose "Oscillating with variable amplitude" mode (amplitude can be chosen for each distance configuration with event-controlled focus control)
Ö OSCILLATING MIRROR tab Ö OSCILLATING MIRROR section – Oscillating with variable amplitude
Ö OSCILLATING MODE section – Frequency
Ö READING CONFIGURATION tab Ö AUTOFOCUS PARAMETERS button respectively
– or –
Distance Configurations – Oscillating mirror amplitude CW 3. Choose "Fixed Position" mode – or –
Ö OSCILLATING MIRROR tab Ö OSCILLATING MIRROR section – Fixed Position
Ö FIXED POSITION section – Stationary Position (CW) 4. Choose "One-Shot" mode
Ö OSCILLATING MIRROR tab Ö OSCILLATING MIRROR section – One-Shot
Ö ONE-SHOT section Ö PHASE 1 – Mirror Speed – Start Position (CW) – Distance Configuration (no.) Ö PHASE 2 – Mirror Speed – Start Position (CW) – Distance Configuration (no.) 5. With One-Shot: choose trigger source
Ö OSCILLATING MIRROR tab Ö ONE-SHOT section Ö TRIGGER MODE – Reading Trigger Pulse or – Switching input or – Serial interface
6. With One-Shot and trigger source "IN 3" or "IN 4": Choose function for switching input "IN 3" or "IN 4"
Ö DEVICE CONFIGURATION tab Ö ASSIGNMENT OF INPUTS Ö IN 3 – One Shot or
Ö IN 4 – One Shot
Ö see also Table 5-29, Page 5-26 7. Choose activity of oscillating mode "Oscillating with ..."
Ö OSCILLATING MIRROR tab Ö OSCILLATING MIRROR ACITVE section – Continuous or – during reading interval
Table 6-9:
6-18
Guide: Configuring oscillating mirror functions
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004