Page 97
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
Note
The OSCILLATE WITH VARIABLE AMPILTUDE operating mode can only be selected from amplitudes of min. ±10 CW and an oscillating frequency of 0.4 Hz or higher. The scan line must always sweep the neutral position (CW = 50). This means that oscillation is not possible in the range 60 CW to 80 CW, for example, but is possible in the range 40 CW to 80 CW. Explanation of oscillating mirror functions 1.
"Oscillating with fixed amplitude" mode
The oscillating mirror deflects the scan line up to the maximum angle of deflection of ±40 CW (corresponds to ±20°). Fig. 6-4 illustrates this mode when a bar code is read from above.
Constant oscillating frequency 0
0
Scan line density depending on object height Fig. 6-4:
2.
Oscillating mirror: "Oscillating with fixed amplitude" mode
"Oscillating with Variable Amplitude" mode
The deflection range can be parameterized separately for each of the maximum of 8 distance configurations/focus positions. The minimum/maximum values that can be set for the deflection range for fast applications ensure that the scan line only sweeps areas that contain bar codes during the time available. This also ensures that the scan line density on the object is, for the most part, constant. Fig. 6-5 illustrates this mode when a bar code is read from above.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-19
Page 98
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
0
Constant oscillating frequency
Limitation of the deflection range (CW value)
0 1
Scan line density equal, independant of object height Fig. 6-5:
3.
Oscillating mirror: "Oscillating with variable amplitude" mode
"Fixed Position" mode
The CLV parks the oscillating mirror at the desired position. 10 CW corresponds to –20°, and 90 CW to +20° (see Fig. 4-8, Page 4-6). In the default setting, the fixed position is set to 50 CW (corresponds to an angle of deflection below 105°). The Oscillating mode is switched off. 4.
"One-Shot" mode
In the "One-Shot" mode, the oscillating mirror only performs one specific oscillating movement per reading interval. This movement consists of a forward phase and a return phase. The start position of the scan line, the mirror speed and the valid distance configuration can be parameterized separately for each phase. The end position of the one phase forms the start position of the other phase. Fig. 6-6 illustrates this mode with object tracking. During the forward phase, the front of the object that moves towards the oscillating mirror is swept once by the scan line from top to bottom in accordance with the conveyor speed. Multiple focus position switchovers are not necessary as the required reading range (DOF) is much smaller than with the line scanner. Fig. 10-42, Page 10-57 explains how the start position and mirror speed are calculated for a given conveyor speed. Possible trigger sources for One-Shot:
6-20
•
"IN 3" or "IN 4" switching input
•
Command string (via serial interface)
•
Start of the reading interval
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 99
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Conventionally required reading range
Line scanner t0 ra ing d a Re nge
Reduced reading range through One-Shot function
Line scanner with oscillating mirror t1 ge ran g n i d Rea
Fig. 6-6:
8 009 993/O824/20-12-2004
One-Shot: Object tracking (bar code read from front)
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-21
Page 100
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner f) Parameterizing reading mode The selected reading mode depends on the number of objects that are simultanously in the reading field of the CLV during each reading interval. This is independent of the number of bar codes on the actual object. Table 6-10 shows an overview of the configurations and applications. A. CLV in stand-alone configuration Configuration
Application
See Page
A. Stand-alone
Start/stop mode • One object in reading field per reading interval, reading one side
6-22
Tracking mode (controlled by increment) • Max. 10 objects in reading field per reading interval, reading one side, with internal object tracking
6-28
Start/stop modes • One object in reading field per reading interval, CLV involved in reading one side or more sides, master/slave arrangement with OTC 400 controller
6-31
Tracking mode (controlled by increment) • Max. 20 objects in reading field per reading interval, CLV involved in reading one side or more sides, with object tracking by the OTC 400 controller
6-34
B. Used in Omni Portal System (arrangement with OTS 400 and other CLVs)
Table 6-10: Overview: CLV applications in stand-alone configuration or in arrangement with OTS 400
A1. Start/stopp mode •
One object in the reading field per reading interval, reading one side
Possible reading triggers: •
One external sensor (e. g. photoelectric reflex switch)
•
Two external sensors
•
Command strings
•
Free-running mode
•
Object polling (Autofocus mode "Minimum distance“ or "Differential background")
Further preparations:
Note
¾
Configuring reading area: see Chapter a)Parameterizing reading area, Page 6-10.
¾
Selecting focus control mode: see Chapter b) Selecting focus control mode, Page 6-11.
¾
Configuring focus control: see Chapter c) Parameterizing focus control, Page 6-12.
¾
Configuring oscillating mirror (optional): see Chapter e) Parameterizing oscillation mirror functions (optional), Page 6-18.
¾
Configuring no. of bar codes to be read: see Chapter h) Parameterizing the evaluation characteristics, Page 6-37.
The size of the reading field is determined by the distance between the start and stop sensors in conveying direction (see Fig. 3-5, Page 3-9). In object polling mode, the CLV detects automatically an object entering or leaving the reading field. To separate bar codes of the same type with identical contents, connect an incremental encoder and activate the "Compare Code Position" function. See also Chapter Separation of identical bar codes (same code type/identical contents), Page 6-37.
6-22
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 101
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Parameterizing reading trigger in the CLV: Action
Settings in CLV-Setup
Parameterize reading trigger: one external sensor
Ö DEVICE CONFIGURATION tab
– or –
Start:
Ö READING TRIGGER SOURCE section – Sensor Input (Active High) or – Sensor Input (Active Low) Ö READING TRIGGER PARAMETERS button Ö DEBOUNCING SENSOR section – Standard or – Fast or – Time controlled: value or – Track contolled: value (with connected increment encoder) Ö FIRST TRIGGER SENSOR section – Edge or – Level Stop: Ö END OF READING INTERVAL section – generated by Trigger Source or – Timer: Timeout (referred to beginning of reading interval) Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö OUTPUT ON GOOD READ section – End of reading gate or – Immediate or – End of Label Ö Using End of label: READING TRIGGER PARAMETERS button Ö END OF LABEL/FREE-RUNNING section Ö Timeout Note: Connect the external sensor to "Sensor“ switching input!
Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone configuration
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-23
Page 102
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
Parameterize reading trigger: two external sensors
Ö DEVICE CONFIGURATION tab
– or –
Start (sensor 1):
Ö READING TRIGGER SOURCE section – Sensor Input (Active High) or – Sensor Input (Active Low) Ö READING TRIGGER PARAMETERS button Ö DEBOUNCING SENSOR section (also for sensor 2 on IN 4) – Standard or – Fast or – Time controlled: value Ö FIRST TRIGGER SENSOR section – Edge or – Level Stop (sensor 2): Ö END OF READING INTERVAL section – generated by IN 4 Ö DEVICE CONFIGURATION tab Ö ASSIGNMENT OF INPUTS section Ö IN 4 – Reading Trigger Stop (Active High) or – Reading Trigger Stop (Active Low) Output of reading result referred to beginning of reading interval: Ö OUTPUT ON GOOD READ section – End of reading gate or – Immediate or – End of Label Ö Using End of label: READING TRIGGER PARAMETERS button Ö END OF LABEL/FREE-RUNNING section – Timeout Note: Connect external sensor 1 (start) to "Sensor" switching input and sensor 2 (stop) to "IN 4" switching input!
Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone configuration (contd.)
6-24
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 103
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
Parameterize reading trigger: command strings
Ö DEVICE CONFIGURATION tab
– or –
Start:
Ö READING TRIGGER SOURCE section – Serial Interface Stop: Ö READING TRIGGER PARAMETERS button Ö END OF READING INTERVAL section – generated by Trigger Source or – Timer: Timeout (referred to beginning of reading interval) Trigger characters: Ö SERIAL INTERFACE section – Standard Trigger or – Single character Ö Using single character: start and stop characters Ö Echo on/off Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö OUTPUT ON GOOD READ section – End of reading gate or – Immediate or – End of Label Ö Using End of label: READING TRIGGER PARAMETERS button Ö END OF LABEL/FREE-RUNNING section Ö Timeout
Parameterize reading trigger: free-running – or –
Ö DEVICE CONFIGURATION tab Start:
Ö READING TRIGGER SOURCE section – Free-running with Timeout: Timeout Stop (generated by reading trigger source): Ö READING TRIGGER PARAMETERS button Ö END OF LABEL/FREE-RUINNING section Ö Timeout Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö OUTPUT ON GOOD READ section – End of reading gate or – Immediate Note: No laser timeout function (defined switching off of laser diode due to too long active reading gate) available in this trigger mode.
Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone configuration (contd.)
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-25
Page 104
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
Action
Settings in CLV-Setup
Parameterize reading trigger: Object polling
Ö DEVICE CONFIGURATION tab Activating object polling: Start:
Ö READING TRIGGER SOURCE section – Object polling Stop: Ö READING TRIGGER SOURCE section Ö END OF READING INTERVAL section – generated by Trigger Source or – Timer: Timeout (referred to beginning of reading interval) or – generated by IN 4 Ö Using IN 4: DEVICE CONFIGURATION tab Ö ASSIGNMENT OF INPUTS section Ö IN 4 – Reading Trigger Stop (Active High) or – Reading Trigger Stop (Active Low) Configuring object polling: Ö OBJECT POLLING PARAMETERS button Ö POLLING PROPERTIES section – Search time – Pause time – Minimum object recognition – Minimum object width Ö OBJECT DETECT SPACE section – Right edge of conveyor (Y 1) – Left edge of conveyor (Y 2) – Level of conveyor (Z 1) – Maximum scanning height (Z 2) Ö SCAN ANGLE LIMITATION section – Min. and max. angle Oscillating mirror: Ö additionally: OSCILLATING ANGLE LIMITATION section – Min. and max. value Define scanner position referred to the conveyor belt: Ö see Table 6-4, Page 6-11, reading space, scanner position Online diagnosis of configured object detection space:
Ö Menu CLV 490 Ö Background analysis – Analysis: object detection Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö OUTPUT ON GOOD READ section – End of reading gate or – Immediate or – End of Label Ö Using End of label: READING TRIGGER PARAMETERS button Ö END OF LABEL/FREE-RUNNING section – Timeout Note: No laser timeout function (defined switching off of laser diode due to too long active reading gate) available in this trigger mode. Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone configuration (contd.)
6-26
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 105
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Explanation
Object polling The process of setting up this automatic reading pulse control (object detection space, scan angle, and oscillating angle limitation) is not the same as that for defining the focus control (reading space and autofocus area) and has to be performed separately. The object detection space should include the rectangular autofocus space. Object polling begins once the system has been started. To prevent incorrect triggering, the system does not return to reading mode from a different operating function or terminate a diagnosis function until a 5 second delay has elapsed. The CLV can carry out object polling in autofocus mode with the "Minimum distance" and "Differential background" modes. The periodic distance measurement is also used for object detection in the parameterizable search interval. The autofocus, however, is only active during the reading gate. To ensure reliable object detection, the CLV must detect an object of the defined minimum width within a preset time in every distance profile (line scanner with oscillating mirror: in at least 3 distance profiles over at least 500 ms). This time is used to debounce the object detection prior to automatic starting of the internal reading gate. Only one object should be in the reading field at any one time. Blanking: the smallest parameterizable object width required for an object to be detected and the reading gate to be started is 100 mm (3.94 in). The minimum object width when the object leaves the reading field (end of reading gate) is 50 mm (1.97 in) (fixed). The object width here is not dependent on the distance between the object and the CLV. After an active reading gate, the pause interval must be at least 70 ms. If the parameterized pause interval is any shorter, the CLV searches for objects continuously with its laser diode permanently switched on. This reduces the service life of the laser diode. In this pulse mode, the oscillating mirror can oscillate permanently or only during the active reading gate.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-27