For the Sick CLV490

Page 106

Operation

Chapter 6

Operating Instructions CLV 490 Bar Code Scanner

A2. Tracking mode (controlled by Increment) •

Max. 10 consecutive objects in conveyor direction simultanously in the reading field, reading one side with internal object tracking

Conditions: •

Minimum object gap between two objects in conveyor direction: 50 mm (1.97 in)

•

Size of reading field = distance between sensor for beginning/end of object and object release point parameterized (data output)

•

Autofocus mode "Differential background and tracking“, see Table 6-6, Page 6-13 or event-controlled focus position switchover

•

Incremental encoder connected to "IN 4" switching input

Possible reading triggers: •

One external sensor (e. g. photoelectric reflex switch)

•

Command strings

Further preparations:

Note

¾

Configuring reading area: see Chapter a)Parameterizing reading area, Page 6-10.

¾

Selecting focus control mode: see Chapter b) Selecting focus control mode, Page 6-11.

¾

Configuring focus control: see Chapter c) Parameterizing focus control, Page 6-12.

¾

Configuring oscillating mirror (optional): see Chapter e) Parameterizing oscillation mirror functions (optional), Page 6-18.

¾

Configuring no. of bar codes to be read: see Chapter h) Parameterizing the evaluation characteristics, Page 6-37

To separate bar codes of the same type with identical contents, connect an incremental encoder and activate the "Compare Code Position" function. See also Table 6-24, Page 6-37. Activating and parameterizing internal object tracking: Action

Settings in CLV-Setup

1. Parameterize internal object tracking

Ö DEVICE CONFIGURATION tab Ö INTERNAL TRACKING Section – active

Ö DISTANCE PER ENCODER PULSE Section – Value: according to encoder resolution

Ö TRACKING PARAMETERS button Ö RELEASE POINTS Section – Focus release point – Object release point/End of reading field/Output data Ö LABEL ASSIGNMENT TOLERANCE Section – Automatic (default setting) or – Fix Tolerance: value Ö READING CONFIGURATION tab Ö AUTOFOCUS PARAMETERS button Ö AUTOFOCUS PARAMETERS tab – CODE BASED FOCUS RELEASE IF... Section – Number of codes equals Minimum or – Number of codes equals Maximum or – Number of codes exeeds Maximum Table 6-12: Guide: Parameterzing internal object tracking

6-28

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 107

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

Action

Settings in CLV-Setup

1. Parameterize internal object tracking – contd. –

Ö DEVICE CONFIGURATION tab Ö ASSIGNMENT OF INPUTS section Ö IN 4 – Conveyor increment Note: Connect external incremental encoder to "IN 4" switching input!

2. Define scanner position referred to the reading field

Ö DEVICE CONFIGURATION tab Ö SCANNER POSITIONS PARAMETERS button Ö ANGLES section – Angles: alpha, beta and gamma

Ö COORDINATES section – x-, y- and z-coordinates 3. Teach-in background (optional)

Ö Menu CLV 490 Ö DEVICE FUNCTIONS Ö Background – Teach-in Check taught-in background: Ö READING CONFIGURATION tab Ö AUTOFOCUS section – SHOW BACKGROUND button Display actual background profile: Ö Menu CLV 490 Ö BACKGROUND ANALYSIS

Table 6-12: Guide: Parameterzing internal object tracking (contd.)

Explanation

Internal object tracking Internal object tracking can be used in autofocus mode with "Differential background and tracking" mode or with event-controlled focus position switchover (e.g. by means of heightcontrol photoelectric switches at switching inputs "IN 0" to "IN 3"). If the reading pulse is started via an external sensor, fast debouncing (≤ 5 ms) is used for the "Sensor" switching input irrespective of the parameter settings. The CLV receives the signals from the incremental encoder via switching input "IN 4". At a constant conveyor speed, the increment can be triggered via an internal timer increment (100 Hz) (set the value for "Path per increment encoder pulse" to 0), which means that an encoder does not need to be connected to IN 4. With object tracking, the reading field length corresponds to the distance in conveying direction between the sensor for starting the reading pulse and the parameterized object release point (see Fig. 3-5, Page 3-9). The focus release point is before the object release point. The CLV uses the internal object management system and its object list to track the objects passing through the reading field, whereby the distance measurement enables objects to be detected and the corresponding focus positions in the focus list to be assigned. The increment management system continuously locates the current position of the objects in the reading field in the conveying direction. The focus list acts as a circular buffer, whereby the oldest entry determines the current focus position. If the CLV calculates that the end of an object being conveyed through the reading field has passed the parameterized focus release point, the CLV switches to the next focus position and deletes the object from the focus list. The reading result for an object is not output until the object has left the object release point.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-29

Page 108

Chapter 6

Operation

Operating Instructions CLV 490 Bar Code Scanner

Parameterizing reading trigger in the CLV: Action

Settings in CLV-Setup

Parameterize reading trigger: one external sensor

Ö DEVICE CONFIGURATION tab Start:

Ö READING TRIGGER SOURCE section – Sensor Input (Active High) or – Sensor Input (Active Low) Ö READING TRIGGER PARAMETERS button Ö DEBOUNCING SENSOR section – Fast Ö FIRST TRIGGER SENSOR section – Edge or – Level Stop: generated by object release point Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö TRACKING PARAMETERS button Ö RELEASE POINTS Section – Object release point/End of reading field/Output data Note: Connect the external sensor to "Sensor“ switching input! Parameterize reading trigger: command strings

Ö DEVICE CONFIGURATION tab Start:

Ö READING TRIGGER SOURCE section – Serial interface Stop: generated by object release point Output of reading result referred to beginning of reading interval: Ö DEVICE CONFIGURATION tab Ö TRACKING PARAMETERS button Ö RELEASE POINTS Section – Object release point/End of reading field/Output data Trigger characters:

Ö SERIAL INTERFACE section – Standard Trigger or – Single character Ö Using single character: start and stop characters Ö Echo on/off Table 6-13: Guide: Parameterizing the reading mode for tracking mode in stand-alone configuration

6-30

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 109

Operation

Operating Instructions

Chapter 6

CLV 490 Bar Code Scanner

B. CLV integrated in OTS 400 Omni Tracking System (mechanical construction called "reading gate") B1. Start/stop mode Conditions: •

One object in the reading field per reading interval Example: Omni-directional 2-side reading with CLVs (slaves) und OTC 400 Controller (master)

•

Minimum object distance > size of reading field (size of reading field = distance between sensor for start and stop of reading trigger)

•

Autofocus/focus position switchover in the CLV according to application: – with OTS height information via CAN bus for reading from top – one distance configuration (fixed focus) for e. g. reading from side and sufficient depth of field (DOF)

•

Autofocus mode "Minimum distance" or "Differential background", see Table 6-6, Page 6-13

•

Two reading sensors connected to OTC 400 (start and stop)

•

Height detection photo reflex switches connected to OTC 400 (optional)

•

Master/slave arrangement using the CAN interface

Possible reading triggers in the CLV: •

OTS trigger

Further preparations for each CLV:

Note

¾

Configuring reading area: see Chapter a)Parameterizing reading area, Page 6-10.

¾

Selecting focus control mode: see Chapter b) Selecting focus control mode, Page 6-11.

¾

Configuring focus control: see Chapter c) Parameterizing focus control, Page 6-12.

¾

Configuring oscillating mirror (optional): see Chapter e) Parameterizing oscillation mirror functions (optional), Page 6-18.

¾

Configuring no. of bar codes to be read: see Chapter h) Parameterizing the evaluation characteristics, Page 6-37.

To separate bar codes of the same type with identical contents, connect an incremental encoder and activate the "Compare Code Position" function. See also Table 6-24, Page 6-37. Parameterizing focus control in the CLV: Action

Settings in CLV-Setup

Use distance information of Ö READING CONFIGURATION tab OTC 400 (master) or other CLV Ö FOCUS CONTROL section – OTS height information – or – Select and parameterize autofocus function see Table 6-6, Page 6-13 or – Table 6-14: Guide: Parameterizing focus control in CLV for master/slaves arrangement with OTC 400

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-31

Page 110

Operation

Chapter 6

Operating Instructions CLV 490 Bar Code Scanner

Action

Settings in CLV-Setup

Select fixed focus and parameterize one distance configuration see Table 6-8, Page 6-16

Forwarding distance informations (optional)

Ö READING CONFIGURATION tab Ö FOCUS CONTROL section Ö AUTOFOCUS PARAMETERS button – AUTOFOCUS OPTIMIZATION PARAMETERS button – OBJECT HEIGHT PASSING IN OTS MODE section – Active

Table 6-14: Guide: Parameterizing focus control in CLV for master/slaves arrangement with OTC 400

Parameterizing reading trigger in the CLV: Action

Settings in CLV-Setup

Parameterize reading trigger

Ö DEVICE CONFIGURATION tab Ö READING TRIGGER SOURCE section – OTS trigger

Table 6-15: Guide: Parameterizing reading trigger in the CLV for master/slave arrangement with OTC 400

Parameterizing slave mode in the CLV: Action

Settings in CLV-Setup

1. Enable slave mode in CLV for Ö DEVICE CONFIGURATION tab OTC 400 (master) Ö TRACKING PARAMETERS button Ö RELEASE POINTS section – Object release point/End of reading field/Output data: 0 mm! – Control box "Master/slave via OTC" active 2. Forwarding reading results to Ö HOST INTERFACE tab the CAN interface Ö DESTINATION OF RESULT DATA STRINGS section – CAN interface 3. Parameterize CAN interface

Ö CAN INTERFACE tab Ö CAN INTERFACE FUNCTION section – OTS slave Ö CAN DATA RATE section – 500 kBit/s

Table 6-16: Guide: Parameterizing slave mode in the CLV for arrangement with OTC 400 (master)

Note

6-32

When in slave mode, the CLV receives the trigger signals for the reading pulse (start and stop) from the OTC 400 via the CAN bus along with (depending on the parameter settings) the distance information required for focus position switchover/autofocus. The distance information can be generated, for example, by the OTC 400 by means of height-control photoelectric switches or can originate from another CLV, which forwards its distance measurements. The CLV sends the reading result (bar code contents) to the OTC 400 via the bus as soon as the bar code(s) have been successfully read. The OTC 400 compiles the results received from all the slaves and evaluates them accordingly before sending them to the host.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 111

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

OTC 400 Controller: Beside other functions parameterize the following function in the OTC 400: Action

Settings in CLV-Setup

Pameterize operation mode in the OTC 400 (master)

Ö DEVICE CONFIGURATION tab Ö READING TRIGGER PARAMETERS button Ö OPERATING MODE section – Time controlled (master/slave) output at end of reading gate or – Time controlled (master/slave) output immediate if...

Table 6-17: Guide: Parameterizing operation mode in the OTC 400 for master/slaves arrangement

For further function to be parameterized in the OTC 400 see the "OTS 400 Omni Tracking System" Operating instructions (order no. 8 008 869, English edition).

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-33

Page 112

Operation

Chapter 6

Operating Instructions CLV 490 Bar Code Scanner

B2. Tracking mode (controlled by increment) Note

SICK AG can design and preconfigure more complex omni-portal systems to fulfill the customer's reading requirements and then provide appropriately trained personnel to install, test and put these systems into operation. An overview of the parameterization steps for an example situation is given below (the overview does not include all available parameterization options). Conditions: •

Max. 20 consecutive objects in conveyor direction simultanously in the reading field. Example: Omni-directional 3-side reading with groups of CLVs (slaves) and OTC 400 Controller (master) for object tracking

•

Minimum object gap between two objects in conveyor direction: 50 mm (1.97 in)

•

Size of reading field = distance between sensor for beginning/end of object and object release point parameterized in the OTC 400 (data output)

•

Autofocus/focus position switchover in the CLV according to application: – with OTS height information via CAN bus for reading from top – one distance configuration (fixed focus) for e. g. reading from side and sufficient depth of field (DOF)

•

Autofocus mode "Differential background and tracking", see Table 6-6, Page 6-13

•

Sensor for beginning/end of object and incremental encoder connected to the OTC 400

•

Master/slave arrangement using the CAN interface

Possible reading triggers: • via OTS

Further preparations for each CLV:

Note

¾

Configuring reading area: see Chapter a)Parameterizing reading area, Page 6-10.

¾

Selecting focus control mode: see Chapter b) Selecting focus control mode, Page 6-11.

¾

Configuring focus control: see Chapter c) Parameterizing focus control, Page 6-12.

¾

Configuring oscillating mirror (optional): see Chapter e) Parameterizing oscillation mirror functions (optional), Page 6-18.

¾

Configuring no. of bar codes to be read: see Chapter h) Parameterizing the evaluation characteristics, Page 6-37

To separate bar codes of the same type with identical contents, connect an incremental encoder and activate the "Compare Code Position" function. See also Table 6-24, Page 6-37. Parameterizing focus control in the CLV: Action

Settings in CLV-Setup

Use distance information of Ö READING CONFIGURATION tab OTC 400 (master) or other CLV Ö FOCUS CONTROL section – OTS height information – or – Select and parameterize autofocus function see Table 6-6, Page 6-13

– or – Table 6-18: Guide: Parameterizing focus control in CLV for object tracking mode with OTC 400

6-34

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 113

Operating Instructions

Operation

Chapter 6

CLV 490 Bar Code Scanner

Action

Settings in CLV-Setup

Select fixed focus and parameterize one distance configuration see Table 6-8, Page 6-16

Forwarding distance informations (optional)

Ö READING CONFIGURATION tab Ö FOCUS CONTROL section Ö AUTOFOCUS PARAMETERS button – AUTOFOCUS OPTIMIZATION PARAMETERS button – OBJECT HEIGHT PASSING IN OTS MODE section – Active

Table 6-18: Guide: Parameterizing focus control in CLV for object tracking mode with OTC 400

Parameterizing reading trigger in the CLV: Action

Settings in CLV-Setup

Parameterize reading trigger

Ö DEVICE CONFIGURATION tab Ö READING TRIGGER SOURCE section – OTS trigger

Table 6-19: Guide: Parameterizing reading trigger in the CLV for object tracking mode with OTC 400

Parameterizing tracking in the CLV: Action

Settings in CLV-Setup

1. Define scanner position referred to conveyor belt

Ö DEVICE CONFIGURATION tab Ö SCANNER POSITIONS PARAMETERS button Ö ANGLES section – Angles: alpha, beta and gamma

Ö COORDINATES section – x-, y- and z-coordinates 2. Parameterize scale factor for Ö DEVICE CONFIGURATION tab incremental pulse Ö DISTANCE PER ENCODER PULSE Section – Value (in agreement with incremental encoder and OTC 400) 3. Define release points

Ö DEVICE CONFIGURATION tab Ö TRACKING PARAMETERS button Ö RELEASE POINTS section – Focus release point: value – Object release point/End of reading field/Output data: value

4. Define label assignment tolerance for object gaps

Ö DEVICE CONFIGURATION tab Ö TRACKING PARAMETERS button Ö LABEL ASSIGNMENT TOLERANCE section – Automatic or – Fixed Tolerance: value

Table 6-20: Guide: Parameterizing tracking in the CLV for object tracking mode with OTC 400

Explanation

8 009 993/O824/20-12-2004

Object tracking takes place in every CLV in the system. For this purpose, each CLV continuously compiles an internal object list. When in slave mode, the CLV receives the required tracking information for the objects in the reading field (consecutive object number, beginning and end of object, incremental encoder status) from the OTC 400 via the CAN bus. Depending on the parameter settings, the distance information for focus position switchover is also sent. The position of the CLV relative to the conveyor belt must be clearly defined to ensure that the bar code(s), object, and scanner are correctly assigned. A

© SICK AG · Division Auto Ident · Germany · All rights reserved

6-35

Page 114

Chapter 6

Operation

Operating Instructions CLV 490 Bar Code Scanner parameterizable tolerance range in conveying direction between two objects at the end and beginning of each object makes it easier to assign the reading results to the individual objects. As soon as a successful reading has been made, the CLV sends the reading result and object assignment (object number and position of the bar code(s) on the object in conveying direction) to the OTC 400 via the CAN bus. The OTC 400 then compiles the results with the same name (identical bar-code contents) received from all the slaves and sends this filtered overall reading result for each object to the host at a defined output time during the reading process. The object release point (data output) parameterized in the OTC 400 marks the end of the reading field. The object release point parameterized in the CLV must always be smaller than that of the OTC 400. The parameter setting for the focus release point depends on whether the CLV is used as part of a group and on its position relative to the conveyor belt. The focus release point is the point in the reading field at which the CLV permits a new focus switchover when the tracked object has passed this point, even if the number of bar codes to be read has not yet been reached. Parameterizing slave mode in the CLV: Action

Settings in CLV-Setup

Parameterize CAN interface

Ö CAN INTERFACE tab Ö CAN INTERFACE FUNCTION section – OTS slave Ö CAN DATA RATE section – 500 kBit/s

Table 6-21: Guide: Parameterizing slave mode in the CLV for object tracking mode with OTC 400

OTC 400 Controller: Beside other functions parameterize the following function in the OTC 400: Action

Settings in CLV-Setup

Pameterize operation mode in the OTC 400 (master)

Ö DEVICE CONFIGURATION tab Ö READING TRIGGER PARAMETERS button Ö OPERATING MODE section – Increment controlled (Tracking)

Table 6-22: Guide: Parameterizing tracking mode in the OTC 400

For further function to be parameterized in the OTC 400 see the "OTS 400 Omni Tracking System" Operating instructions (order no. 8 008 869, English edition).

6-36

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004