Page 115
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner g) Parameterizing laser timeout (for trigger source "Sensor input“/"Ser. interface“) Action
Settings
1. Choose laser timeout duration – or –
Ö DEVICE CONFIGURATION tab Ö READING TRIGGER PARAMETERS button Ö LASER TIMEOUT section – Duration
2. Deactivate laser timeout (The laser diode is always active, independent of the pulse duration)
Ö LASER TIMEOUT section – Click (deactivate) the control box INTERVAL ACTIVE
Table 6-23: Guide: Parameterizing the laser timeout h) Parameterizing the evaluation characteristics •
Choose decoder type Ö CODE CONFIGURATION tab Ö DECODER section
•
Activate code types for evaluation Ö CODE CONFIGURATION tab Ö SYMBOLOGIES section and EDIT button
•
Activate code comparison Ö DEVICE CONFIGURATION tab Ö MATCH CODE PARAMETERS button
Separation of identical bar codes (same code type/identical contents) Number of bar codes per object
Stationary conveyor object
Moving conveyor object
Number n > 1: – Same code type – Contents different or identical
Ö CODE CONFIGURATION tab Ö CODE POSITION section
Ö CODE CONFIGURATION tab Ö CODE POSITION section
– Activate "Compare" – Min. distance between labels Ö NUMBER OF CODES section – Minimum – Maximum
– Activate "Compare" – Min. distance between labels Ö NUMBER OF CODES section – Minimum – Maximum
Ö DEVICE CONFIGURATION tab Ö SCANNER POSITION PARAMETERS button Ö ANGLES section – Angle alpha Ö DISTANCE PER ENCODER PULSE section – value Table 6-24: Guide: Parameterizing the separation of identical bar codes
Note
If the number n > 1, minimum distances must be provided between the bar codes on the object, if • the SMART decoder is to read bar codes that originate from the same code type and have identical or different data contents
• the standard decoder is to read and distinguish bar codes with the same name (identical code type and data content)
The necessary calculations are provided in Chapter 10.8.3 Calculating the necessary bar code distance if several bar codes are read on each object, Page 10-58.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-37
Page 116
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner i) Parameterizing the output characteristics Result status: swichting outputs/ "Read Result" LED: •
Define function of result status output of "Result 1" to "Result 4" switching outputs ("Read Result" LED): DEVICE CONFIGURATION tab Ö RESULT OUTPUT PARAMETERS button
Main Data Interface general: •
Destination result data strings Ö HOST INTERFACE tab Ö DESTINATION OF RESULT DATA STRINGS section
•
Filter reading result Ö DEVICE CONFIGURATION tab Ö ODETTE FILTER section
•
Sort reading result Ö DATA STRINGS tab Ö OUTPUT SEQUENCE SORT section
•
Mask reading result Ö DATA STRINGS tab Ö FORMAT MASK section
Host Interface: •
Arrangement in data network Ö DEVICE CONFIGURATION tab Ö SCANNER ARRANGEMENT section
•
Physical interface Ö HOST INTERFACE tab Ö DATA FORMAT section
•
Communication parameters Ö HOST INTERFACE tab Ö DATA FORMAT section
•
Protocol Ö HOST INTERFACE tab Ö INTERFACE PROTOCOL section
Function of the CAN interface (alternative): See the operating instructions ”Application of the CAN interface” (no. 8 009 180, English edition) Data output string of host interface: •
Choose contents of "Header", "Code Info/Separator", "Splitter" and "Terminator" blocks Ö DATA STRINGS tab Ö OUTPUT FORMAT section
•
Position of "Code Info/Separator" blocks in data output string Ö DATA STRINGS tab Ö POSITION OF CODE INFO/SEPARATOR section
•
Set wrong read format Ö DATA STRINGS tab Ö READING DATA IN CASE OF ERROR section, CHARACTER COUNT section and ERROR STRING section
•
If necessary, parameterize/activate test string Ö DATA STRINGS tab Ö TEST STRING section
•
Parameterize special functions Ö DATA STRINGS tab Ö SPECIALS button
•
Output external data string as reading result Ö DATA STRINGS tab Ö EXTERNAL DATA STRING PARAMETERS button j) Parameterizing the terminal interface mode (auxiliary interface) •
AUXILIARY INTERFACE tab k) Defining the start option for accessing the parameter set •
6-38
DEVICE CONFIGURATION tab Ö START WITH ... section
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 117
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
6.5
Operating modes and outputing the reading result
The following CLV operating modes/functions (and more) can be selected in CLV-Setup: Standard operating mode: •
Reading mode
For setup: •
Percentage evaluation
•
Adjusting mode
For adapting the device to the application at hand: •
Configuring (parameterizing) the CLV. See Chapter 6.4.1 Configuring the CLV via the user interface of CLV-Setup, Page 6-5
•
Background teach-in
•
Show background
•
Show CP-limits
For monitoring purposes/trouble shooting: •
Background analysis
•
I/O monitor in incremental pulse
•
Display and edit operating data
•
Reading diagnosis
•
Monitor host interface
•
Auxiliary input
•
Self-test
6.5.1
Reading mode (standard operating mode)
The CLV performs a self-test after it has been switched on. It switches to Reading mode ("Device Ready" LED lights up). In the default setting the "Sensor" switching input is the (external) trigger source of the reading pulse. The reading result is output by the CLV at the end of the reading pulse via the host interface (default setting) and terminal interface. Depending of the configuration, the "Result 1" to "Result 4" switching outputs become live for the predefined pulse length when defined events occur during the reading process (e. g. Good Read). The reading result of the terminal interface can be displayed in the CLV-Setup Terminal Emulator. The CLV terminal interface must be set to the Reading Diagnosis mode for this purpose. This mode is selected for the default setting. The reading result of the terminal interface has a fixed, invariable format. The Reading mode can be called up by choosing VIEW in the menu bar or via the Terminal Emulator. Line scanner with oscillating mirror: In the Reading mode the CLV deflects (by default) the scan line about the position CW = 50 at a frequency of 1 Hz and a maximum angle of ±20°. 50 CW corresponds to an angle of deflection of 105°.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-39
Page 118
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Displaying the reading result in the Terminal Emulator: 1.
Click in the toolbar. The Terminal Emulator window is then displayed.
2.
In the DEVICE MODE section, choose READING MODE.
3.
Present the bar code pattern from Fig. 6-1, Page 6-4 to the CLV and activate the reading pulse. The scan line must not hit any object in a distance closer to the CLV than the represented bar code (default setting: autofocus mode "Minimum distance"). The "Sensor" LED lights up and the red scan line appears.
4.
Ending the reading pulse. The CLV displays the reading result in the output window of the Terminal Emulator. The "Read Result" LED lights up for a duration of 100 ms (default setting).
Fig. 6-7 shows two examples of the output of a reading result: "Good Read" and "No Read". The reading result comprises the data contents of the bar code(s) and the reading diagnosis data. Fig. 6-8 explains the structure and function of the reading diagnosis data for "Good Read", and Fig. 6-9 for "No Read". Note
The CLV only outputs several bar codes in the reading result of the host interface if the parameterized minimum and maximum number of bar codes is > 1, and several bar codes have been presented to it. The number of bar codes to be read/output for each reading interval can be selected in the CODE CONFIGURATION tab in the NUMBER OF CODES section. The reading result of the host interface can also be displayed. Chapter 6.5.10 Monitor Host Interface, Page 6-55 describes the procedure for this and the structure of the reading result in the default setting.
Fig. 6-7:
6-40
CLV-Setup: Displaying the reading result of the termianl interface in the Terminal Emulator
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 119
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Good Read: TT=_ _160 ms MG=_26 % n=_1 AK=1 0123412345 C39 100% ST=0 CL=10 CP=_50 CD=_924 CS=_ 34 CA=_ 34 CK=_ 34 DI=F PO=–_ _4 OW=+_ _0 FC=_907 CX=_839 CY=_594 CZ=1190 ON _ _40 With: 1st. line :
2nd. line: 3rd. line:
4th line
TT = MG = n = AK = 0123412345 = C39 = 100% = ST = CL = CP = CD = CS = CA = CK = DI = PO OW FC CX CY
= = = = =
CZ ON
= =
Duration of the reading interval (ms) Temporal mean value of the identification quality (%) Number of detected bar codes No. of the used distance configuration1) Data contents of the bar code ID: Code type Code 39 along Identification quality (%) Read status (ST = 0: Good Read) Code length (number of characters) Code position Code distance, radial measured (mm) Code reliability Scan effort Code continuity Decoding direction (F = in scanning direction, R = against scanning direction) Exact code position (3-digit for tracking, in °)(unit 0,1°) Exact oscillating angle (3-digit for tracking, in °)(unit 0,1°) Current focus position (4-digit for tracking) X-coordinate of bar code (for OTS in transport direction) Y-coordinate of bar code (for OTS across to transport direction) Z-coordinate of bar code (for OTS from above directly) consecutive object number (only for tracking)
1) not relevant for autofocus function
Fig. 6-8:
Reading result of the terminal interface: structure for "Good Read"
No Read: TT=_ _ 140 ms MG=_26 % n=_0 AK=1 no code!
1st. line :
2nd. line:
TT MG n AK no code!
= = = = =
Duration of the reading interval (ms) Temporal mean value of the identification quality (%) Number of codes detected No. of the distance configuration used1) No bar codes found!
1) not relevant for autofocus function
Fig. 6-9:
8 009 993/O824/20-12-2004
Reading result of the terminal interface: structure for "No Read"
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-41
Page 120
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Triggering the reading pulse via the Terminal Emulator In the default setting the "Sensor" switching input is the (external) trigger source of the reading pulse. The reading pulse can also be triggered directly via the Terminal Emulator of CLVSetup for test purposes. To do so, a different trigger source must be selected temporarily in the CLV. 1.
Choose DEVICE CONFIGURATION tab.
2.
In the READING TRIGGER MODE section click the SERIAL INTERFACE option.
3.
Perform a download to the CLV. To do so, click the SERIAL INTERFACE option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The serial interface has been activated as the trigger source of the reading pulse and is ready to receive appropriate commands (until the CLV is switched off).
4.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in the Reading mode.
5.
Click the SW-TRIGGER ON button or press [F7]. CLV-Setup sends a start command to the CLV. The "Sensor" LED lights up and the red scan line appears.
6.
Present the bar code pattern from Fig. 6-1, Page 6-4 to the CLV.
7.
Click the SW-TRIGGER OFF button or press [F8]. CLV-Setup sends a stop command to the CLV. The "Sensor" LED is extinguished. The CLV switches off the laser diode. The CLV displays the reading result in the output window of the Terminal Emulator. The "Read Result" LED lights up for a duration of 100 ms (default setting).
6.5.2
Percentage evaluation
In the Percentage evaluation mode, the quality of the reading function is assessed (no conveyor movement). The CLV performs continuously 100 scans in the free running mode and evaluates the reading quality. It outputs the reading result every 2 s via the terminal interface. The reading results can be displayed in the Terminal Emulator of CLV-Setup. The "Result 1" to "Result 4" switching outputs do not become live in the Percentage evaluation mode. The standard decoder has to be set temporarily for the percentage evaluation. The Percentage evaluation mode can be called up by choosing VIEW in the menu bar, as a device function via CLV 490 (interactively), or via the Terminal Emulator. Note
6-42
Autofocus mode: If the CLV operates with autofocus in stand-alone configuration, the Percentage evaluation mode can only be started in the Autofocus mode "Minimum distance" or "Differential background". The CLV fixes the timeout of the automatic focus position switchover to 30 ms, the preferred focus position is set to the last recognised object. If the CLV operates with autofocus in OTS mode ("Differential background and tracking"), the CLV switches automatically to the autofocus mode "Differential background“ during the the Percentage evaluation mode.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 121
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Line scanner with oscillating mirror: In the Percent Evaluation mode, the CLV behaves in the following manner: – in "Oscillating" mode (basic setting: oscillating with a fixed amplitude), the CLV shuts off oscillation and positions the scan line under the angle CW = 50 (corresponds to a deflection angle below 105°). This position cannot be altered.
– in "One-Shot" mode, the CLV positions the scan line under the angle CW = 50 as well.
– in ”Fixed position” mode, however the scan line’s selected position remains unchanged.
1.
Choose the CODE CONFIGURATION tab.
2.
In the DECODER section, choose STANDARD.
3.
Perform a download to the CLV. To do so, click the STANDARD option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The CLV then operates with the standard decoder (until the CLV is switched off).
4.
Click in the toolbar. The Terminal Emulator window is displayed. The CLV is in the Reading mode.
5.
In the DEVICE MODE section, choose PERCENTAGE EVALUATION The dialog box for choosing the distance configuration is then displayed.
6.
Choose the appropriate distance configuration for the reading distance: – with autofocus mode the distance configuration no. 1 – with event-controlled focus control the distance configuration that corresponds to the reading distance of the object (default setting: no. 1, focus position F1 = 1,200 mm (47.3 in)).
7.
Confirm the dialog box with OK. The ”Device Ready” LED is extinguished. The CLV initiates the percentage evaluation and outputs the reading results continuously. An example shows Fig. 6-10.
Fig. 6-10:
8.
8 009 993/O824/20-12-2004
CLV-Setup: Displaying the percentage evaluation in the Terminal Emulator
Present the bar code pattern from Fig. 6-1, Page 6-4 and monitor the reading results in the Terminal Emulator window.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-43
Page 122
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Note
In default setting, the CLV operates in the autofocus mode "Minimum distance“. As a result, the CLV focuses on the object that is nearest in Percentage Evaluation mode. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must be selected. Alternatively a fixed focus position can be set. See Chapter c) Parameterizing focus control, Page 6-12. The output format of the reading result is the same as that of the Reading mode. Fig. 6-8, Page 6-41 explains the structure and function of the reading diagnosis data The ”Read Result” LED also provides information on the reading quality: –
The LED is extinguished if reading quality is < 30 %
–
The LED blinks twice per second if the reading quality is 30 % to 70 %
–
The LED blinks five times per second if the reading quality is 70 % to 90 %
–
The LED is lit continuously if the reading quality is > 90 %
6.5.3
Adjusting mode
The Adjusting mode enables the center of the scan line to be optimally positioned on the bar code. Chapter 4.3.3 Adjusting mode, Page 4-9 describes the procedure for going about this after the Adjusting mode has been called up. The CLV does not output a reading result in this mode. The "Result 1" to "Result 4" switching outputs do not become live. The Adjusting mode can be called up by choosing VIEW in the menu bar, as a device function via CLV 490 (interactively), or via the Terminal Emulator. Line scanner with oscillating mirror: In the "Adjusting" mode, the CLV behaves in the following manner:
6-44
–
In "Oscillating" mode (default setting: oscillating with a fixed amplitude), the CLV shuts of oscillation and positions the scan line under the angle CW = 50 (corresponds to an angle of deflection below 105°). This position cannot be altered.
–
In "One-Shot" mode, the CLV positions the scan line under the angle CW = 50
–
In "Fixed Position" mode, the scan line’s selected position remains unchanged.
1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in the Reading mode.
2.
In the DEVICE MODE section, choose ADJUSTING MODE. The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and blanks the red scan line as of position CP = 50 to position CP = 100.
3.
Choose READING MODE to exit the Adjusting mode. The CLV returns to the Reading mode and the "Device Ready" LED lights up.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 123
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
6.5.4
Background teach-in
If the Autofocus function is used in the "Differential Background" or "Differential Background and Tracking" mode, the CLV must first learn the ambient background in its reading field to narrow the reading field even further. When the internal distance profile is set, the reading field of the CLV must not contain any objects. In this mode, the CLV does not output any reading results. The Background teach-in function can be started as a device function via CLV 490 (interactively), or press the [F2] key. Line scanner with oscillating mirror: In the "Background teach-in" mode, the CLV behaves in the following manner: – in "Oscillating" mode (default setting: oscillating with a fixed amplitude), the CLV shuts off oscillation and positions the scan line under the angle CW = 50 (corresponds to an angle of deflection below 105°). This position cannot be altered.
– in "One-Shot" mode, the CLV positions the scan line under the angle CW = 50.
– in "Fixed Position" mode, the scan line’s selected position remains unchanged.
Starting the background teach-in: 1.
Mount the CLV at the reading station and align it with an object containing a bar code.
2.
Remove the object so that the CLV has an unobstructed view of the background.
3.
Choose CLV 490, DEVICE FUNCTIONS, BACKGROUND, TEACH-IN – or – press the [F2] key. The EXECUTE DEVICE FUNCTIONS window opens. Choose BACKGROUND, TEACH-IN in the EXECUTE menu. The "Device Ready" LED extinguishes. The CLV then scans its background and learns the ambient background so that it can create a suitable distance profile. The CLV outputs a message once the teach-in procedure has been successfully completed (see Fig. 6-11). The CLV has then learned the ambient background.
Fig. 6-11:
8 009 993/O824/20-12-2004
CLV-Setup: Dialog window for running the background teach-in
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-45