Page 124
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
4.
Choose CLOSE to close the window. If the parameters in the CLV were modified as a result of the teach-in procedure, CLVSetup asks you whether you want to copy and display the modified parameter set by uploading it from the CLV.
5.
Confirm the query with YES. The dialog box closes automatically. The CLV resumes Reading mode and the "Device Ready" LED lights up.
Displaing the taught-in background: The new background distance profile can be uploaded and displayed in CLV-Setup via the terminal interface of the CLV. CLV-Setup displays the background without any parameterized limitations ("Autofocus space"). 1.
Choose the READING CONFIGURATION tab.
2.
In the AUTOFOCUS section, click the SHOW BACKGROUND button. The SHOW BACKGROUND dialog box appears. An example of a distance profile is shown in Fig. 6-12.
Fig. 6-12:
Note
6-46
CLV-Setup: Display of th learned background
The CLV adjusts the entire profile of the taught-in background by minus 100 mm (3.94 in), that is, the entire background curve is moved toward the CLV by this amount (also in the display in CLV-Setup) to compensate measurement inaccuracies. The parameterized limits of the applicable autofocus space are not corrected. The CLV also shifts the edges of the measured profile toward the center by 2 angular elements. If no background has been taught in, the CLV uses the default background (2,200 mm ( 86.7 in) across the entire distance profile).
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 125
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
6.5.5
Show CP-limits
In this mode, the CLV blanks certain parts of the red scan line so that any limit values defined for the active evaluation range of the scan line can be checked directly during parameterization. The restricted active evaluation range shortens the evaluation time for fast applications, for example, because the evaluation routine only has to take account of unblanked parts of the scan line. The range is restricted by entering appropriate values for MINIMUM CODE POSITION and MAXIMUM CODE POSITION in the DISTANCE CONFIGURATION tab. The CLV does not output a reading result in this mode. Show CP-limits enables you to check whether •
The visible range of the CLV has been defined accordingly for the selected setting in autofocus mode (restriction is independent of reading distance and always the same)
•
The restriction has been adapted for each active distance configuration in eventcontrolled dynamic focus control ("Christmas tree" effect)
Show CP-limits can be called up via VIEW in the menu bar, as a device function via CLV 490 (interactively), or via the Terminal Emulator. Line scanner with oscillating mirror: In "Show CP-limits" mode, the CLV behaves in the following manner: – in "Oscillating" mode (default setting: oscillating with a fixed amplitude), the CLV shuts off oscillation and positions the scan line under the angle CW = 50 (corresponds to an angle of deflection below 105°). This position cannot be altered.
– in "One-Shot" mode, the CLV positions the scan line under the angle CW = 50.
– in "Fixed Position" mode, the scan line’s selected position remains unchanged.
The CLV blanks the scan line alternately as of the set value for CPmin and as of the set value for CPmax . Fig. 6-13 shows an example of this. The switchover is made continuously at intervals of 1 second. The part of the scan line that remains active for the reading procedure is the section between CPmin and CPmax. Example: Default setting: CPmin = 5 to CPmax = 95. The CLV blanks the line as of CPmin= 5 (short scan line) and as of CPmax = 95 (long line). Show CP limits
CPmax Active range
Scan line 2
CPmin Scan line 1
Fig. 6-13:
8 009 993/O824/20-12-2004
Appearance of scan line in the "Show CP-limits" mode
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-47
Page 126
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Proceed as follows to check the restricted evaluation range:
Note
1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in the Reading mode.
2.
In the DEVICE MODE section, choose SHOW CP-LIMITS. The dialog box for the distance configuration is then displayed.
3.
Click the distance configuration for which the active evaluation range of the scan line has been restricted (DC-specific). The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and blanks the red scan line alternately (as described above) as of CPmin and CPmax.
4.
Check Step 2 and 3 for each active distance configuration to determine whether the bar code is in the center of the range between the end of the shorter scan line (CPmin) and the end of the longer scan line (CPmax) or, if there are several bar codes, to determine whether the center of the field of all the codes is within the range.
5.
If necessary, correct CPmin and CPmax accordingly. Perform a download to the CLV!
6.
Choose READING MODE to exit the Show CP-limits mode. The CLV returns to the Reading mode and the ”Device Ready” LED lights up.
In the Reading mode, the CLV does not actually blank the scan line visually, but instead takes the values specified for the restricted evaluation range into account when the data contents are decoded. 6.5.6
Background Analysis
In this mode, CLV-Setup shows online how the CLV interprets the distance measurement of its visual range. This function provides information on the gradient of the current detected background (current distance profile), the background which was corrected via parameterizing/Background Teach-in and the points in the distance profile focused on by the CLV. The distance measurement must be activated for this (default setting). ¾
Click or choose CLV 490, BACKGROUND ANALYSIS in the menu bar. The BACKGROUND ANALYSIS dialog box is displayed and shows the values in the plot diagram. The red line shows the current distance profile, the blue line shows the corrected background.
Fig. 6-14:
6-48
CLV-Setup: Example of output in the "Background Analysis" dialog box
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 127
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Choosing displayed curves ¾
To check the parameterization of the autofocus function of the CLV, activate the AUTOFOCUS checkbox in the ANALYSE section. We recommend that just the background without object be viewed with the function first, and then check whether the CLV has correctly focused on the object after it is brought into the foreground.
¾
To check the parameterization of the object polling function of the CLV, activate the OBJEKT RECOGNITION checkbox in the ANALYSE section. If the CLV detects a current object, the diagram displays an object detection marker (rhombi). Test: Remove the object. The CLV must not focuse, also not to the background.
Starting/Stopping updating CLV-Setup polls the CLV once per second for the current distance profile (red) of the scan line in order to update the display. 1.
To "freeze" the curves temporarily for viewing, click the STOP button. CLV-Setup interrupts the updating process.
2.
To continue, click the START button. CLV-Setup continues updating.
The curves for the corrected background (blue) are static and are only polled once when the dialog box is opened. Zooming in on area of plot diagram Any area of the plot diagram can be enlarged (zoomed in) by selecting it with the mouse (hold down the left mouse button and drag the cursor to form a rectangle). Pressing the right mouse button returns to the plot diagram at the normal output size. 6.5.7
I/O monitor in increment trigger
Function of the terminal interface. In this mode, CLV-Setup displays the conditions of the various switching inputs/outputs of the CLV and any data transfer via the host interface. This is done in a dialog box and is time-independent of the increment trigger. Increment signals to the switching input "IN 4" of the CLV in the "Tracking" reading mode are required here. The display is continuous; the monitored signals are recorded. After the monitor is called up, the display is started by the next data output from the CLV. The display function in CLV-Setup can be used for troubleshooting when starting up or when malfunctions occur during operation, as it supplies a convenient overview of the system condition at each moment. The function itself has no effect on the CLV, apart from the temporary change of the terminal interface operating mode. The inputs, outputs and direction of data transfer which is to be monitored can be selected. The display sequence of the signals in the plot diagram can be changed. Up to 15 signals can be displayed one under the other at the same time. The contents of the data output or data reception of the host interface is displayed separately without protocol characters in two output fields. The configured signal selection/sequence remains until CLV-Setup is ended so that the monitor can be called up again without needing to be reconfigured.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-49
Page 128
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
Configuring and calling up I/O monitor for display 1.
In the symbol bar, click or select CLV 490, I/O MONITORING in the menu bar. The SIGNAL CHOICE dialog box is then displayed (Fig. 6-15).
2.
Select the desired input, output or data transfer direction for each selection (entry) on the left side in one of the drop-down lists.
3.
Click the ADD button. The previously selected entry appears at the end of the list in the SIGNALS TO PLOT field to the right.
4.
Repeat for other entries. A signal cannot be selected twice.
5.
If necessary, delete undesired inputs, outputs or a data transfer direction from the list. Select the relevant entry and click the REMOVE button. Several entries can be chosen selectively by holding down the [CTRL] key and selecting with the left mouse button. A block selection is done by holding down the [SHIFT] key and selecting with the left mouse button.
6.
If the sequence in the list is to be changed, select the desired entry and move it to the preferred location using the "up arrow" and "down arrow" buttons. Several entries can be moved selectively or as a block at the same time here as well.
Fig. 6-15:
CLV-Setup: Selection of the signals to be displayed in I/O Monitoring
7.
After configuration is complete, click START MONITORING. CLV-Setup begins with the display of the switching statuses/data output in the I/O MONITORING dialog box as soon as data is output from the CLV. An example is shown in Fig. 6-16.
8.
To cancel the display, click CLOSE in the I/O MONITORING dialog box and exit the SIGNAL CHOICE dialog box by clicking CLOSE. – or – Click EXIT in the I/O MONITORING dialog box. CLV-Setup resets the operating mode of the terminal interface to its original function. This also applies when the SIGNAL CHOICE dialog box is exited with CLOSE without having started the I/O Monitor.
6-50
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 129
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Fig. 6-16:
CLV-Setup: Example of output in the "I/O Monitoring" dialog box a) RUN mode After opening, the dialog box automatically displays the switching conditions (high, low), their result-dependent changes and the data communication of the host interface as a marker in the plot diagram. This is done continuously. The selected signals and potentials (1 = high, 0 = low) are listed on the y axis, and the current time down to the 10 ms is listed on the x axis. When the recording reaches the right edge of the window, the screen is scrolled to the right 30 %. The current increment status is located on the bottom, left-hand side next to the arrow buttons. The time stamp of the last time at which an event occurred is located below this. In the RECEIVE output field, CLV-Setup displays the contents of the data string which was last received via the host interface by the CLV. A time stamp is displayed next to this. The TRANSMIT output field identifies the contents of the data string which was last sent by the CLV. A time stamp is displayed next to this. Other functions are not possible in this mode of just the display. b) STOP mode This mode is used for the selective display and printing of events and measurement. ¾
8 009 993/O824/20-12-2004
Click the STOP button. CLV-Setup cancels the continuous display in the plot diagram and the fields, but continues to record in the background. A small table for displaying measured values appears.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-51
Page 130
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
Scrolling through events: A scroll bar will appear to allow scrolling to previous events in the plot diagram which are not visible in the display. The large arrow buttons on the bottom, left-hand side also enable scrolling through the events (down arrow: backward in time, up arrow: forward in time). The arrows next to both output fields control the display of data strings. Zooming in on area of plot diagram: Using the XY cursor, selected areas of the plot diagram can be enlarged (zoomed in). 1.
Click the CURSOR ON button. The XY cursor appears.
2.
Position the XY cursor anywhere in the plot diagram and, holding down the left mouse button, drag the cursor to form a rectangle containing the area to be enlarged.
3.
Release the mouse button. The selected area is enlarged and adjusted to fit the dialog box. In addition, a vertical scroll bar appears on the right side of the dialog box. A section can be enlarged with up to six levels of magnification. The signal names remain unchanged; the colors can be used to differentiate between the conditions in the plot diagram.
4.
To reduce the zoom factor to the output level, click the ZOOM OUT button as many times as is needed.
5.
Click the CURSOR OFF button to hide the XY cursor.
Calling up a specific event and accompanying data: Clicking the left mouse button in the plot diagram causes CLV-Setup to display the event which is closest to the x position of the cursor in all output fields (exception: measured value table). This allows the accompanying data of a data string to be called up selectively to the Receive or Transmit output field. The time and increment status of a rising or falling signal edge can be called up as well. If the mouse pointer is located directly between two events when clicked, the event which occurred first is displayed. Measuring increment status and time differential in plot diagram Using the measured value table which appears, measurements can be made within the visible range of the plot diagram. Two measurement cursors are available for this purpose. They are activated/deactivated with the right mouse button. 1.
Place the mouse pointer over the plot diagram and press the right mouse button. The first measurement cursor appears.
2.
Place the measurement cursor on an edge of one of the signals. The corresponding time and the increment status of the first event are displayed in the output fields INCREMENT 1 and TIME 1 of the table.
3.
Press the right mouse button again. The second measurement cursor appears.
4.
Place the measuring cursor to the right of the first measuring cursor on an edge of the same signal or of another angle which you are interested in. The corresponding time and the increment status of the second event are displayed in the output fields INCREMENT 2 and TIME 2 of the table. In addition, the time differential and the increment differential are displayed in the DELTA INC and DELTA TIME output fields.
Pressing the right mouse button again or scrolling through the display clears both measuring cursors, and the table disappears.
6-52
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 131
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
Placing the second measurement cursor to the left (previous point in time) of the first measurement cursor is not permitted. If this is attempted, the first measurement cursor which was set and the table contents are cleared. A cursor cannot be placed outside the visible range of the plot diagram. An event which cannot be seen can appear in the measured value table, however. Printing contents of window: This function enables the signal conditions which were just displayed in the window to be printed out as a window with the designations of the plot diagram axes. The printout also contains the corresponding values of the increment status, time stamp, measured value table and contents of the data strings of both output fields. 1.
Click the PRINT button. The dialog box for printing is displayed.
2.
Activate the relevant entries and confirm with OK.
Returning to RUN mode: ¾
8 009 993/O824/20-12-2004
Click the START button. CLV-Setup returns to the continuous display of the signal conditions. Any enlargements of areas of the plot diagram are undone.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-53
Page 132
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
6.5.8
Displaying and editing operating data
This function enables statistical operating data, which the CLV maintains in the form of counters during the reading procedure, to be displayed and reset. The CLV does not output a reading result in this mode. 1.
Click in the tool bar. The CLV cancels the Reading mode and the "Device Ready" LED is extinguished. The OPERATING DATA dialog box appears (Fig. 6-17).
2.
After checking/resetting the desired counters, click OK to confirm any changes made. The CLV then returns to the Reading mode and the "Device Ready" LED lights up.
Fig. 6-17:
6-54
CLV-Setup: "Operating Data" dialog box
© SICK AG · Division Auto Ident · Germany · All rights reserved