Page 133
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
6.5.9
Reading diagnosis
Function of the terminal interface. In this mode, the CLV outputs the data contents of all the bar codes that were read – including those that, according to the evaluation criteria, were not read properly and were thus incorrect – together with the associated reading diagnosis data via the terminal interface. The number of bar codes output can, therefore, be higher than the number of those that were sent via the host interface in the reading result. In the default setting, this mode is selected for the terminal interface. Fig. 6-8, Page 6-41 shows the output format of the terminal interface. In the default setting, the CLV does not output any reading diagnosis data via the host interface. If the reading diagnosis is to remain inactive, this can be set via the AUXILIARY INTERFACE tab. 1.
In the AUXILIARY INTERFACE drop-down list, choose READ DIAGNOSTICS.
2.
Perform a download to the CLV by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.
3.
Choose the PERMANENT storage option in the dialog box.
The terminal interface is now set to the "Read Diagnostics" mode. 6.5.10
Monitor Host Interface
Function of the terminal interface. In this mode, the CLV outputs the data traffic of its host interface via the terminal interface. Protocol driver handshakes and protocol-specific data, such as start and stop characters, are suppressed here. Each data string is displayed on a separate line on the screen. Two monitoring modes are available that differ with regard to the data output format (Table 6-25). Mode
Direction of data
Output format
Representation on screen
"Monitoring host interface"
CLV receives from host CLV sends to host
<STX> I Data <CR> <LF> <ETX> <STX> O Data <CR> <LF> <ETX>
I Data O Data
"Monitoring host interface 2"
CLV receives from host CLV sends to host
<STX> Data <ETX> <STX> Data <ETX>
Data Data
Table 6-25: "Monitor Host Interface" function
The MONITOR HOST INTERFACE or MONITOR HOST INTERFACE 2 function is activated via the AUXILIARY INTERFACE tab.
Note
8 009 993/O824/20-12-2004
1.
In the AUXILIARY INTERFACE drop-down list, choose MONITOR HOST INTERFACE or MONITOR HOST INTERFACE 2.
2.
Perform a download to the CLV. To do so, click the desired option in the list again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The terminal interface then operates in the choosed "Monitor Host Interface" mode until the CLV is switched off again.
On good read, the CLV only outputs the number of read bar codes being defined for maximum on the CODE CONFIGURATION tab, in the NUMBER OF CODES section.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-55
Page 134
Operation
Chapter 6
Operating Instructions CLV 490 Bar Code Scanner
Displaying the data traffic of the host interface in the Terminal Emulator: The data traffic of the host interface can be displayed in the Terminal Emulator of CLV-Setup. Fig. 6-18 shows an example of how the reading result can be output. 1.
Choose the serial interface as the external trigger source for the reading pulse. See Chapter 6.5.1 Reading mode (standard operating mode), Page 6-39.
2.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in the Reading mode.
3.
Click on the SW-TRIGGER ON button or press [F7]. The red scan line then appears.
4.
Present the bar code pattern from Fig. 6-1, Page 6-4.
5.
Click the SW-TRIGGER OFF button or press [F8]. CLV-Setup outputs the reading result in the Terminal Emulator. Example: "O 0123412345".
Fig. 6-18:
Note
CLV-Setup: Displaying the reading result of the host interface in the Terminal Emulator with direction identifier at the beginning (in this case: O = Output)
If a large amount of data is being read in at high speed and with a high transmission rate, the host interface’s data trafficing may no longer be completely displayed on the terminal interface (display "..."). This is due to the slower transmission rate of the terminal interface (9,600 bd). In the default setting, the CLV sends the following in the data output string of the host interface: •
On Good Read: Data content of one bar code
•
On No Read: Character string "NOREAD"
The "Header", "Code-Info/Separator", "Splitter" und "Terminator" blocks are blank.
6-56
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 135
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
Tip
The structure of the data output string of the host interface can be configured via the DATA STRINGS tab. •
Up to 10 elements, consisting of constants (letters, digits, control characters) and/or reading diagnosis data, can be entered in the "Header", "Code-Info/Separator", "Splitter" und "Terminator" blocks.
•
Up to 5 elements, consisting of constants (letters, digits, control characters) can be entered in the "Splitter" blocks.
•
The position of the "Code-Info/Separator" block can be choosen before or after the code.
1.
Choose the DATA STRINGS tab.
2.
Click the HEADER field. The EDIT PARAMETER: TFH dialog box is then displayed.
3.
Click the desired constants or placeholders for the reading diagnosis data. The selected elements appear in the text box at the top of the dialog box in the sequence in which they were selected.
4.
Confirm the entries made by clicking OK.
5.
Repeat this procedure for the "Code-Info/Separator", "Splitter" und "Terminator" blocks.
6.
Perform a download to the CLV by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.
7.
Choose the PERMANENT storage option in the dialog box. The CLV outputs the selected elements in the data output string of the host interface with the next reading result.
6.5.11
Auxiliary input
Function of the terminal interface. In this mode, the CLV accepts a bar code entered at the terminal interface (via the keyboard or hand-held scanner with decoder). It sends the bar code to the host in a separate data string via its host interface. No reads can, therefore, be corrected by transmitting missing bar codes subsequently. Chapter 10.11.1 Auxiliary input via terminal interface, Page 10-69 describes this function and the associated procedure in greater detail. 6.5.12
Code statistics for RDT 400
Function of the terminal interface. The CLV outputs a data string with statistic information of the reading situation in this mode. For an deailed description of the functions and applications of the Remote Diagnostic Tools RDT 400, see the RDT 400 Operating Instructions (no. 8 009 385, English edition). "Code statistics for RDT 400" is activated via the AUXILIARY INTERFACE tab.
8 009 993/O824/20-12-2004
1.
Select the Code Statistics option for RDT 400 on the AUXILIARY INTERFACE tab.
2.
Perform a download to the CLV. To do so, click the RDT 400 option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The terminal interface then operates in "Code statistics for RDT 400" mode until the CLV is switched off again.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-57
Page 136
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
6.5.13
Self-test
After the CLV has been switched on, it performs a self-test before it is initialized with the parameter set. The test can be called up explicitly at any time via CLV-Setup. During the selftest, the CLV checks that its hardware components are functioning correctly. A final message via the terminal interface provides information on the test result. The CLV does not output a reading result during the test routine. 1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in the Reading mode.
2.
In the DEVICE MODE section, choose SELF TEST. The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and starts the test routine. After a few seconds, the CLV outputs the encoded test result in the form of a code number (Fig. 6-19).
3.
To return to the Reading mode, click READING MODE or close the Terminal Emulator. The CLV then returns to the Reading mode and the "Device Ready" LED lights up.
Fig. 6-19:
CLV-Setup: Displaying the self-test result in the Terminal Emulator
The code number ”15000” means that the self-test was completed successfully and that no faults were diagnosed. Chapter 8.3.1 CLV without external parameter memory, Page 8-2, lists the error keys together with the associated corrective measures.
6-58
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 137
Operating Instructions
Operation
Chapter 6
CLV 490 Bar Code Scanner
6.5.14
Executing CLV functions interactively
CLV-Setup enables a number of CLV functions to be executed interactively. CLV-Setup prompts the user to carry out specific actions and provides information on the progress of the function being executed. The following functions are available: •
Background teach-in/reset (to default)
•
Percentage evaluation
•
Show CP-limits
•
Adjustment mode
•
Copy parameter memory (internal -> external, external -> internal)
•
Analyze CAN Scanner Network
•
Activate factory defaults in device
¾
Choose CLV 490, DEVICE FUNCTIONS and the desired function – or – press the [F2] key. The EXECUTE DEVICE FUNCTIONS dialog box is then displayed. Choose the desired function in the EXECUTE menu in the menu. CLV-Setup starts the function and, where appropriate, prompts the user to carry out the necessary actions.
Fig. 6-20 shows an example of the dialog box that appears after Show CP-limits has been started.
Fig. 6-20:
8 009 993/O824/20-12-2004
CLV-Setup: Dialog box for executing Show limits
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-59
Page 138
Chapter 6
Operation
Operating Instructions CLV 490 Bar Code Scanner
6.6
CLV messages
The CLV outputs encoded system and error messages via the terminal interface to report user actions or events in the reading process. When the system is started, the CLV also outputs system messages in plain text (English). If configured accordingly, the CLV transfers the error status ST in the data output string of the host interface. 6.6.1
Displaying messages
In the 4th field from the left in the status bar at the bottom of the screen, CLV-Setup displays system and error messages that occur at the terminal interface of the CLV. These are recorded in a file, which is continuously updated. The messages have the following format: •
System message: "CLV SYS-Message: xxx"
•
Error message:
"CLV SYS-Failure: xxx"
The additional system messages in plain text can be displayed in the terminal emulator if CLV-Setup and the terminal emulator are started before the CLV is connected. Additional messages: When the system is started, these system messages inform the user whether the starting process was successful. No further measures are normally required. Fig. 6-21 shows an example.
Fig. 6-21:
CLV-Setup: Displaying the system messages in the Terminal Emulator when starting the CLV
Chapter 10.5 System messages, Page 10-42 explains the meaning of the messages.
6-60
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 139
Operation
Operating Instructions
Chapter 6
CLV 490 Bar Code Scanner
6.6.2
Error messages
Error messages indicate the following types of error: • a device defect
• incorrect parameter settings
• errors during data transmission to the host
Chapter 8.3 Error messages, Page 8-2 lists the messages with the associated corrective measures. Note
To call up the most recent error to occur in the CLV, enter command "2?SF" in the command line of the terminal emulator.
6.7
Switching off the CLV
1.
If the parameter set was modified in CLV-Setup or was only stored temporarily in CLV via a download ("Temproray" option or via context menu (right mouse button)), the parameter set must be stored permanently in the CLV by choosing the PERMANENT storage option.
2.
Save the parameter set as a configuration file "*.scl" in CLV-Setup.
3.
Switch off the power supply of the CDM 490 or unplug both of the CLV’s connecting cables from the connection module.
The last parameter set stored permanently in the CLV remains valid. Archiving the parameter set: We recommend that you print out the configuration file in order to archive the parameter set.
8 009 993/O824/20-12-2004
1.
Click in the toolbar. The PRINT FILE dialog box is then displayed.
2.
Enter a comment in the input field in order to assign the printout to the CLV. Confirm your entry with OK. The PRINT dialog box for configuring the printer is then displayed.
3.
Make the necessary entries in the dialog box and confirm these. CLV-Setup prints out the current configuration file in the form of a table.