Operating Instructions: CLV490 Bar Code Scanner, Advanced Line, pages 149 to 156

Pages 149 to 156 of 266

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV490

Page 149

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

8.4

ST error status in the reading result of a bar code

Value

Meaning

Possible cause

Remedy

0

Good Read.

–

Not applicable.

2

No bar code of the enabled code type found according to the evaluation criteria.

• No bar code in the CLV‘s reading field during the reading pulse

• Synchronize the pulse of the CLV with the entry of a bar code into the reading field. • Correct the code configuration parameters. • Check the reading window.

• Code type/length in the CLV not enabled for decoding • Reading window obstructed/dirty 3

Device fault.

Device fault.

5

Required number of successful multiple • Conveyor speed of the object is too reads for the bar code not reached. high • Scanning frequency is too low • Ladder-type arrangement for bar code relative to the conveyor direction: code height (bar length) too poor • Print quality too poor

Call up the self-test. See Chapter 6.5.13 Self-test, Page 6-58. If result ≠ 15000: Contact the SICK Service department. • Check the conveyor speed. • Adjust the scanning frequency. • Check the code height.

• Check the print quality.

6

Master: • The parameterized number of slaves • Check the entered number of slaves. Number of slave reading results does does not match the actual number of not match the parameterized number of slaves available slaves. • The master timeout is too short • Check the master timeout setting. • The data connection between the • Check the cables between the slaves slaves and/or the master has been and the master. interrupted

7

The source of the reading result is the auxiliary input via the terminal interface.

The bar code was not detected by the reading function of the CLV, but was entered subsequently with the auxiliary function of the terminal interface and sent to the host in a separate data string.

9

The OUTPUT FILTER function is activated for the code comparison. The CLV has detected valid bar codes. However, these do not match the active match code(s).

The scanned object does not have a bar – code that matches the specified match code.

A

The CHECK MAX. NUMBER OF CODES function is active. The number of valid bar codes detected by the CLV in Reading mode exceeds that specified under NUMBER OF CODES: MAXIMUM. It repeatedly outputs the defined error string until the number specified under NUMBER OF CODES: MINIMUM is reached.

One object in a set of objects with a constant number of bar codes, for example, contains more bar codes than defined in the application.

This message is used to indicate errors on the objects (e. g. check whether objects are homogeneous: mixed with incorrect objects).

D

The CODE 32 evaluation option is activated for Code 39. The CLV is attempting to interpret 6-digit C39 bar codes as C32 bar codes (output as 9-digit decimal values).

The read 6-digit bar code is not a C32 bar code. The CLV outputs the defined error string instead.

–

–

Table 8-4: Meaning of the ST error status in the reading result

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-7

Page 150

Troubleshooting

Chapter 8

Operating Instructions CLV 490 Bar Code Scanner

Value

Meaning

Possible cause

Remedy

F

The CHECK MIN. NUMBER OF CODES function is active. The number of valid codes detected by the CLV in Reading mode is less than that specified under NUMBER OF CODES: MINIMUM. Instead of the code contents, it outputs the defined error string in the quantity defined under NUMBER OF CODES: MINIMUM

One object in a set of objects with a constant number of codes, for example, contains fewer codes than defined in the application.

This message is used to indicate errors on the objects (e. g. check whether objects are homogeneous: mix with incorrect objects).

Table 8-4: Meaning of the ST error status in the reading result (contd.)

8-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 151

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

8.5

Troubleshooting

The following are required for troubleshooting purposes using the tables below: •

These Operating Instructions

•

Tools

•

A tape measure (up to 3 m (9.84 ft))

•

A digital measuring device (current/voltage measurement)

•

A PC running CLV-Setup

•

A 3-core RS 232 data cable (null modem cable), pins 2 and 3 crossed, e. g. no. 2 014 054

8.5.1

General malfunctions: CLV not ready

Malfunction

Possible cause

The "Device Ready" LED is not lit. The "Result 1" output is not outputting a pulse (default setting: Device Ready)

After switching on the power supply: • The CLV has no power.

• The CLV has diagnosed a device error during the self-test.

Remedy • Check wiring (power connector fitted securely to the CDM 490 Connection Module). Measure voltage at pin 1 and pin 5. • Switch CLV off and on again. Does the LED light up? If not, contact SICK Service department

During operation: • The CLV is not in "Reading" mode.

• Return to Reading mode using the "CLVSetup" program. See Chapter 6.5.1 Reading mode (standard operating mode), Page 6-39 • Terminate reading pulse. • The CLV has deactivated the laser diode Check the reading pulse function. Supply 10 min. (default setting) after the start of new pulse. See Table 6-23, Page 6-37. the current reading pulse (trigger mode: sensor input/serial interface). Table 8-5: Troubleshooting: restoring operation (Reading mode)

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-9

Page 152

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

8.5.2 ¾

Malfunctions in Reading mode: reading trigger errors

Check whether the "Device Ready" LED lights up. If the LED does not light, see Table 8-5, Page 8-9.

CLV in stand-alone configuration Malfunction

Possible cause

1. Trigger mode: Sensor input (external sensor).

Reading mode "Start/stop" or "Tracking ": • Sensor not connected or connected to incorrect switching input.

The CLV cannot be clocked: – the "Sensor" LED does not light up – the red scan line does not appear

• •

• •

•

•

Remedy

• Connect sensor to "Sensor" switching input. Check sensor wiring (see Fig. 5-5, Page 5-23). Measure output signal on sensor. If sensor supplied by CLV: sensor not • Insert jumper between pin 5 and pin 15 connected to ground potential. (CDM 490: S 1 switch "SGND_GND") Incorrect reading pulse source para• In the "CLV-Setup" program: choose the meterized in the CLV. DEVICE CONFIGURATION tab, READING TRIGGER SOURCE section: Sensor input selected? (active high: reading pulse starts when power applied, active low: reading pulse starts when power removed) • See above. Polarity of switching input inverted • In the "CLV-Setup" program: choose the Incorrect debouncing of the switching DEVICE CONFIGURATION tab, click the input parameterized in the CLV. READING TRIGGER PARAMETERS button, DEBOUNCING SENSOR section: Time controlled: selected value too high? Track controlled: incremental encoder connected to "IN 4" switching input? • Align sensor. Photoelectric switch not aligned with the Check functioning reflector (photoelectric proximity switch/ inductive sensor not dampened). • Install reading pulse sensor in front of the The object does not pass the reading CLV in conveying direction. See also pulse sensor for trigger start with the Chapter 4.4.2 Mounting the external reaconveyor running. ding pulse sensor, Page 4-11 .

Table 8-6: Troubleshooting: reading trigger errors in Reading mode (CLV in stand-alone configuration)

8-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 153

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

Malfunction

Possible cause

2. Trigger mode: Serial interface

Reading mode "Start/stop" or "Tracking ": • Incorrect reading pulse source parameterized in the CLV.

The CLV cannot be clocked: – the "Sensor" LED does not light up – the red scan line does not appear

• In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, READING TRIGGER SOURCE section: is "serial interface" selected? Serial Interface section: is the trigger type correct? • Use correct commands. • Incorrect command used. Standard trigger: Start: <START> 21 <STOP> Stop: <START> 22 <STOP> – or – defined single characters (DEVICE CONFIGURATION tab, click the READING TRIGGER PARAMETERS button, SERIAL INTERFACE section). For reading mode "Tracking": only start command required. • Check data connection to host. • The CLV is not receiving any command In the "CLV-Setup" program: choose the strings on the data interface to start the HOST INTERFACE tab. reading interval. In DATA FORMAT section: are the correct interface type (hardware) and data format selected? INTERFACE PROTOCOL section: are the correct start and stop characters selected? Use the "CLV-Setup" program to check the host command strings: choose AUXILIARY INTERFACE tab. Choose MONITOR HOST INTERFACE function. See Chapter 6.5.10 Monitor Host Interface, Page 6-55. Download temporarily to the CLV. Reading mode "Start/stop": • Incorrect reading pulse source parameterized in the CLV.

3. Trigger mode: Object Polling The CLV does not trigger automatically: – the "Sensor" LED does not light up – the red scan line does not appear

Remedy

• Incorrect critera for automatic object detection parameterized in the CLV.

• Incorrect position of the CLV referred to the object detection space parameterized in the CLV.

• In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, READING TRIGGER SOURCE section: is "object polling" selected? • In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, click the OBJECT POLLING PARAMETERS button: POLLING PROPERTIES section: are the correct values selected? OBJECT DETECT SPACE section: are the correct values selected? If necessary: are the correct SCAN ANGLE and/or OSCILLATING ANGLE LIMITATION selected? • In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, click the SCANNER POSITION PARAMETERS button: are the correct values selected?

Table 8-6: Troubleshooting: reading trigger errors in Reading mode (CLV in stand-alone configuration) (contd.)

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-11

Page 154

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

Malfunction

Possible cause

4. CLV does not respond to an external signal that ends the reading pulse (sensor input, serial interface)

Reading mode "Start/stop": Trigger mode: one external sensor • Incorrect end of reading pulse parameterized in the CLV.

• No signal from the sensor at the "Sensor“ switching input.

Remedy

• In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, click the READING TRIGGER PARAMETERS button. END OF READING INTERVAL section: is "generated by Trigger Source" selected? • Check wiring of the sensor (see Fig. 5-5, Page 5-23). Measure output signal of the sensor.

Trigger mode: two external sensors • Connect sensor to the "IN 4“ switching • If "IN 4“ switching input is choosen as input. Check wiring of the sensor (see trigger source for end of reading interval: Chapter 5.5.7 Connecting the "Sensor" no sensor connected or polarity inverted. switching input, Page 5-23). Choose the DEVICE CONFIGURATION tab, ASSIGNMENT OF INPUTS section: is "IN 4" selected (active high or active low)? Click the READING TRIGGER PARAMETERS button, END OF READING INTERVAL section: is "generated by IN 4“ selected? • Install reading pulse sensor in front of the • The object does not pass the reading CLV in conveying direction. pulse sensor for trigger start with the See also Chapter 4.4.2 Mounting the exconveyor running. ternal reading pulse sensor, Page 4-11 Trigger mode: serial interface • Incorrect command used. • Laser timeout exceeded.

• See 2. Remedy • See remedy in Table 8-5, Page 8-9.

5. CLV does not terminate the reading clock Reading mode "Tracking": or terminate the clock too late • Incremental encoder not connected or connected to the wrong switching input.

• •

•

• •

• Connect incremental encoder to the "IN4“ switching input. Check wiring (Fig. 5-6, Page 5-24). Check the output signal of the incremental encoder. Choose the DEVICE CONFIGURATION tab, ASSIGNMENT OF INPUTS section: IN 4: "Conveyor increment" selected? If incremental encoder supplied by CLV: • Insert jumper between pin 5 and pin 15 (CDM 490: S 1 switch "SGND_GND"). encoder not connected to ground. Incorrect reading mode parameterized • In the "CLV-Setup" program: Choose the DEVICE CONFIGURATION tab, in the CLV. READING TRIGGER SOURCE section: "Sensor Input" selected? INTERNAL TRACKING section: "active" selected? • In the "CLV-Setup" program: Incorrect resolution of incremental enINTERNAL TRACKING section: "Distance per coder parameterized in the CLV. encoder pulse" correctly selected? No conveyor motion (CLV does not re• Start the conveyor. ceive incremental signals). • See remedy in Table 8-5, Page 8-9. Laser timeout exceeded.

Table 8-6: Troubleshooting: reading trigger errors in Reading mode (CLV in stand-alone configuration) (contd.)

8-12

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 155

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

CLV integrated in OTS 400 Omni Tracking System Malfunction

Possible cause

1. Trigger mode in the CLV: OTS trigger

• Incorrect reading pulse source parameterized in the CLV.

Reading mode "Start/stop": • CLV not triggered by the OTC 400: – the "Sensor" LED does not light up – the red scan line does not appear

•

•

•

Remedy

• In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, READING TRIGGER SOURCE section: is "OTS trigger" mode selected? • In the "CLV-Setup" program: choose the CLV not parameterized as Slave. DEVICE CONFIGURATION tab, click the TRACKING PARAMETERS button, RELEASE POINTS section: OBJECT RELEASE POINT/END OF READING FIELD/DATA OUTPUT section: "0 mm" selected? Check box "MASTER/SLAVE VIA OTC" activated? CAN interface incorrectly parameterized • Check: CAN INTERFACE tab, CAN INTERFACE FUNCTION section: "OTS slave" as well as in the CLV. "data transfer rate" selected in accordance to OTC 400? Sensors for start and stop of reading trig- • Check connection and parameterization of switching inputs, see OTS 400 Operager: incorrectly connected to OTC 400 or ting Instructions (no. 8 008 869, English switching inputs incorrectly parameteredition). ized. • Check in OTC 400 with the "CLV"Master/Slave" mode not selected in Setup" program: the OTC 400. choose the DEVICE CONFIGURATION tab, click the READING PARAMETERS tab, OPERATING MODE section: one of the two modes for master/slave selected?

• Incorrect reading pulse source parameterized in the CLV.

2. Trigger mode in the CLV: OTS trigger Reading mode "Tracking": CLV not triggered by the OTC 400: – the "Sensor" LED does not light up – the red scan line does not appear

• In the "CLV-Setup" program: choose the DEVICE CONFIGURATION tab, READING TRIGGER SOURCE section: "OTS trigger" mode selected? • CAN interface incorrectly parameterized • Check: CAN INTERFACE tab, CAN INTERFACE in the CLV. FUNCTION section: "OTS Slave" as well as "data transfer rate" selected in accordance to OTC 400? • Sensor for beginning of object (at the be- • Check connection and parameterization ginning of the reading field) incorrectly of switching inputs, see OTS 400 Operaconnected to OTC 400 or switching input ting Instructions (no. 8 008 869, English incorrectly parameterized. edition). • Incorrect operation mode selected in the • Check in OTC 400 with the "CLV-Setup" OTC 400. program: choose the DEVICE CONFIGURATION tab, click the READING TRIGGER PARAMETERS button, OPERATING MODE section: "Increment controlled (Tracking)" selected?

Table 8-7: Troubleshooting: reading trigger errors in Reading mode (CLV integrated in OTS 400 Omni Tracking System)

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-13

Page 156

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

8.5.3 ¾

Malfunctions in Reading mode: result output errors

Check whether the "Device Ready" LED lights up. If the LED does not light, see Table 8-5, Page 8-9.

CLV in stand-alone configuration Here: number of bar codes to be read = 1 Malfunction

Possible cause

Remedy

1. The "Read Result" LED (default setting: • Read not successful, since there was no • Synchronize read with presence of an bar code in the reading field during the object in reading field. See Chapter 8.5.2 Good Read) does not light up at the end of the reading pulse. reading pulse. Malfunctions in Reading mode: reading trigger errors, Page 8-10. • Scan line positioned incorrectly. • Align CLV. Is bar code at center of scan – The "Result 2" switching output line? Check the reading quality with the (default setting: Good Read) is not "CLV-Setup" program: choose PERCENoutputting a pulse TAGE EVALUATION. See Chapter 6.5.2 Per– The CLV outputs status ST=2 in the centage evaluation, Page 6-42. reading result on the host interface (outputting of ST disabled by default) • Bar code presented at incorrect reading • Check whether reading distance of bar code is in the specified reading range? distance. – The CLV outputs the message "no • The presented bar code’s module width • Present a bar code with an acceptable code" in the reading result of the module width. See Chapter 9 Technical cannot be read by the CLV type being terminal interface data, Page 9-1. used. Reading range (bar code evaluation range): • In the "CLV-Setup" program: choose the • Evaluation range of the scan line is READING CONFIGURATION tab, click the AUlimited unfavourable (CP values). TOFOCUS PARAMETERS respectively DISTANCE CONFIGURATION button. Are the – or – min. and max. code position values correct? Check with SHOW CP-LIMITS. See Chapter 6.5.5 Show CP-limits, Page 6-47. • In the "CLV-Setup" program: choose the • Parametrized rectangular reading area READING CONFIGURATION tab, READING AREA does not match the conditions in situ. section, READING AREA option, click the READING SPACE PARAMETERS button: are the values for reading space correct? • In the "CLV-Setup" program: choose the • Position of the CLV referred to the DEVICE CONFIGURATION tab, click the SCANreading space not or incorrectly NER POSITION PARAMETERS button: are the parameterized. values correct? Focus control: • Focus control not activated. • In the "CLV-Setup" program: choose the READING CONFIGURATION tab, FOCUS CONTROL section: "Autofocus" or "Inputs/serial" for event-controlled focus position switchover selected? (for oscillating mirror also "Oscillating Mirror Extrema") Table 8-8: Troubleshooting: result output errors in Reading mode (CLV in stand-alone configuration)

8-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004