Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

Malfunction

Possible cause

Remedy

1. The "Read Result" LED (default setting: Autofocus: Good Read) does not light up at the end • An obstacle in the reading area is closer • In the "CLV-Setup" program: choose the of the reading pulse: to CLV than the object carrying the bar READING CONFIGURATION tab, AUTOFOCUS code(s). The CLV focuses on the obstasection: "Differential background" select– continued – cle and not on the object (autofocus ed? mode incorrectly parameterized). • Autofocus parameters incorrectly • In the "CLV-Setup" program: choose the parameterized. READING CONFIGURATION tab, AUTOFOCUS section: click the AUTOFOCUS PARAMETERS button, click the AUTOFOCUS LIMITS PARAMETERS button: are the values for limitations and/or the autofocus space correct? Is the autofocus range within the limits of the parameterized reading range? • Distance measurement (needed for au- • In the "CLV-Setup" program: choose the tofocus function) inactive. READING CONFIGURATION tab, AUTOFOCUS section, click the AUTOFOCUS PARAMETERS button, click the AUTOFOCUS OPTIMIZATION PARAMETERS button: is the distance measurement active? SOURCE OF DISTANCE INFORMATION section: "internal/external" selected? Event-controlled focus control: • Wrong focus position in Distance Configuration choosen.

• In the "CLV-Setup" program: choose the READING CONFIGURATION tab, click the DISTANCE CONFIGURATION button. Does the focus position match the distance of the object? • CLV does not switch over the focus posi- • In the "CLV-Setup" program: choose the READING CONFIGURATION tab, FOCUS CONtion: trigger source incorrectly parameTROL section: terized. a) Trigger source "Inputs/Serial": Check functional assignment of "IN 3" and "IN 4" and connection of the sensors. See Fig. 5-6, Page 5-24 b) Trigger source: "Serial interface": Check the data connection to the host. Use the "CLV-Setup" program to check the host command strings: choose AUXILIARY INTERFACE tab. Choose MONITOR HOST INTERFACE function. See Chapter 6.5.10 Monitor Host Interface, Page 6-55. Download temporarily to CLV! c)Trigger source: Timer: Check switchover time referred to the start of reading interval d) Line scanner with oscillating mirror: Optional "Oscillating Mirror Extrema“ selected? Table 8-8: Troubleshooting: result output errors in Reading mode (CLV in stand-alone configuration) (contd.)

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-15

Page 158

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

Malfunction

Possible cause

Remedy

• In the "CLV-Setup" program: choose the CODE CONFIGURATION tab, DECODER section: choose SMART decoder. Download all changes to CLV! The reading angles at which the bar code • In the "CLV-Setup" program: choose the appears to the CLV are too large. CODE CONFIGURATION tab, DECODER section: choose Standard decoder. Download temporarily to CLV! Start PERCENTAGE EVALUATION, choose DISTANCE CONFIGURATION. Monitor reading quality (reading quality > 70 %!). If necessary, realign CLV and/or reconfigure distance configuration. If ok, choose SMART DECODER. Download to CLV. Bar code in total reflection zone • Optimize CLV alignment (scan line should strike the bar code at a skew of approx. 15°). Use the "CLV-Setup" program to check the quality of the read. Start PERCENTAGE EVALUATION. See Chapter 6.5.2 Percentage evaluation, Page 6-42 • In "CLV-Setup" program: choose the Evaluation criteria for bar code CODE CONFIGURATION tab, SYMBOLOGIES incorrect. section. Enable all code types (except Pharmacode), set code lengths to FREE. Download temporarily to CLV! Start PERCENTAGE EVALUATION. Code type and length are displayed in the reading result. Enable recorded code type in the CODES section and disable all other types. Enter the code length under FIXED on the code type tab. Download to CLV! • Check: sufficient blank zones present? Bar code quality inadequate. Print contrast adequate? Specified print tolerances exceeded? In the "CLV-Setup" program: choose READING CONFIGURATION tab, READING PARAMETERS section, START/STOP RATIO: is Auto selected? Perform read with reference code.

1. The "Read Result" LED default setting: • The bar code is tilted excessively with Good Read) does not light up at the end respect to the scan line. of the reading pulse: •

– continued –

•

•

•

2. The CLV is not transferring any reading results to the host

• Reading pulse is not functioning correctly. • Wiring fault in data connection. • Voltage level incorrect. • Host interface in CLV parameterized incorrectly.

• See Chapter 8.5.2 Malfunctions in Reading mode: reading trigger errors, Page 8-10 • Check wiring as shown in Fig. 5-3, Page 5-21 • Measure voltages • In "CLV-Setup" program: choose HOST INTERFACE tab, DATA FORMAT section. Are the interface type (hardware) and data format correct? Check settings in INTERFACE PROTOCOL section.

Table 8-8: Troubleshooting: result output errors in Reading mode (CLV in stand-alone configuration) (contd.)

8-16

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 159

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

Malfunction

Possible cause

Remedy

3. The data content of the bar code output • The data format on the host interface is • In the "CLV-Setup" program: choose the by the CLV is incorrect or incomplete. parameterized incorrectly in the CLV. HOST INTERFACE tab, DATA FORMAT section. Are the values correct? • The CLV suppresses the last character in • In the "CLV-Setup" program: choose the the bar code. CODE CONFIGURATION tab, SYMBOLOGIES section. Click the EDIT button of the relevant code. Is the TRANSMIT CHECK DIGIT checkbox activated? Change if necessary. Download to CLV! 4. The CLV transfers the status ST=3 to the The CLV has diagnosed a device error in host in the reading result (outputting of the self-test. ST disabled by default)

Switch the CLV off and on again. Does the "Device Ready" LED light up? If not, contact the SICK Service department.

Table 8-8: Troubleshooting: result output errors in Reading mode (CLV in stand-alone configuration) (contd.)

Additional for CLV integrated in OTS 400 Omni Tracking System Malfunction

Possible cause

Remedy

1. OTS Reading mode: "Start/stop"

If the CLV uses distance information from OTC 400 or other CLVs: CLV is not receiving any distance information.

In the "CLV-Setup" program: choose READING CONFIGURATION tab, FOCUS CONTROL section: "OTS height information" selected?

– The "Read Result" LED on CLV (default setting: Good Read) does not light up at the end of reading interval 2. OTS Reading mode: "Tracking"

• CLV is not receiving any increment information from OTC 400.

• Check connection and parameterization of incremental encoder on the OTC 400, see OTS 400 Operating Instructions (no. 8 008 869, English edition). – The "Read Result" LED on CLV (default setting: Good Read) does not • Release points incorrectly parameterized • In the "CLV-Setup" program: choose the in the CLV. DEVICE CONFIGURATION tab, click the TRACKlight up during reading process ING PARAMETERS button: are the values correct? Is the object release point of CLV within the limits of the object release point of OTC 400?

3. OTS Reading mode: "Tracking "

• If an incremental encoder is connected: • Check contact between the incremental the sensor is transferring an incorrect encoder and conveyor belt conveyor speed to the arrangement. As • If objects are read on a section between a result, the OTC 400 cannot correctly belts, checks whether the conveyor assign bar codes to the objects. speed of the two belts is different

– OTC 400 not sending any reading results to the host

• If an internal increment pulse is used in • the arrangement: the pulse does not match the actual conveyor speed.

Adapt the internal increment pulse to the actual conveyor speed or connect an external incremental encoder to OTC 400 if the conveyor speed is not constant (parameterize switching input accordingly)

Table 8-9: Troubleshooting: result output errors in Reading mode (CLV integrated in the OTS 400 Omni Tracking System)

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-17

Page 160

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

8.5.4 ¾

Malfunctions in Reading mode: errors in the result status output

Check whether the "Device Ready" LED lights up. If the LED does not light, see Table 8-5, Page 8-9 .

Malfunction

Possible cause

Remedy

The switching outputs – "Result 1" (default setting: Device Ready) – "Result 2" (default setting: Good Read) – "Result 3" (default setting: No Read) – "Result 4" (default setting: Match 1) are not outputting any pulses.

• The event associated with the assigned • Not applicable. function for outputting the result status of the read does not occur in the reading operation. • Incorrect switching mode parameterized • In the "CLV-Setup" program: choose the in the CLV. DEVICE CONFIGURATION tab. Click the RESULT OUTPUT PARAMETERS button. Are the outputs set to "No Invert Output"? Change if necessary. Download to CLV!

Table 8-10: Troubleshooting: errors in the result status output in Reading mode

8-18

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 161

Operating Instructions

Troubleshooting

Chapter 8

CLV 490 Bar Code Scanner

8.5.5 ¾

Malfunctions in Reading mode: oscillating mirror errors

Check whether the "Device Ready" LED lights up. If the LED does not light, see Table 8-5, Page 8-9.

Malfunction

Possible cause

Remedy

1. The oscillating mirror does not move.

Incorrect operating mode set in the CLV.

In the "CLV-Setup" program: choose the OSCILLATING MIRROR tab, OSCILLATING MIRROR section. Is OSCILLATING WITH FIX AMPLITUDE or OSCILLATING WITH VARIABLE AMPLITUDE selected?

2. The oscillating mirror oscillates with • OSCILLATING WITH FIX AMPLITUDE set in the • From the OSCILLATING MIRROR tab, choose maximum deflection (40 CW), even CLV by mistake. OSCILLATING WITH VARIABLE AMPLITUDE. though a variable amplitude, e. g. 10 CW, Download to the CLV! is set in the distance configuration 1. • The oscillating amplitude is paramterized • In the "CLV-Setup" program: choose the in the wrong distance configuration READING CONFIGURATION tab, click the (here: no. 2). DISTANCE CONFIGURATION button. Is the amplitude value set in the correct distance configuration (here: no. 1)? • The distance configuration (focus • In the "CLV-Setup" program: choose the position) was not changed. DEVICE CONFIGURATION tab. Assignment of Inputs for "IN 3" and "IN 4": is focus control selected? Connect sensors to the switching inputs. Check sensor wiring (see Fig. 5-6, Page 5-24). Measure output signal at sensor 3. One-Shot: The One-Shot function cannot • Trigger source incorrectly parameterized • In the "CLV-Setup" program: be triggered (sensor correctly connected choose the OSCILLATING MIRROR tab. Is "one-shot" selected? to the "IN 3" or "IN 4" switching input). • "IN 3" or "IN 4" switching input has not • Choose DEVICE CONFIGURATION tab. ASSIGNMENT FOR INPUTS section: "IN 3" or been assigned this function. "IN 4": is trigger "One-Shot" selected? Table 8-11: Troubleshooting: oscillating mirror errors in Reading mode

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-19

Page 162

Chapter 8

Troubleshooting

Operating Instructions CLV 490 Bar Code Scanner

8.6

SICK Support

If a system error occurs repeatedly ("CLVSYS-Failure: xxx", xxx= 000 ... 215) or if you cannot correct an error using the above measures, the CLV may be defective. The CLV does not contain any components that can be repaired by the user. Please contact your local SICK office or subsidiary:

8-20

•

The telephone numbers and email addresses are listed on the back page of this manual. For postal adresses see also www.sick.com.

¾

Do not send the device to the SICK service without first contacting us.