For the Sick CLV490

Page 163

Operating Instructions

Technical data

Chapter 9

CLV 490 Bar Code Scanner

9

Technical data 9.1

Data sheet CLV 490-0010/-2010/-6010 bar code scanner

Type

CLV 490-0010 (Standard density)

Design line scanner (standard device), without heater

Reading window front

Laser diode (wave length)

red light (λ = 650 nm)

CLV 490-2010 (High density)

CLV 490-6010 (Low density)

MTFB of laser diode

20,000 h

Laser class

Class 2 (pursuant to EN 60825-1), shutoff of laser diode after 10 min1)

Focus Control

Autofocus, alternatively event-controlled focus control

No. of distance configurations (DC)

max. 8

Focus adjustment time

≤ 20 ms (typically)

Focus trigger source

"IN 0" to "IN 4" switching inputs/data interface/timer

Useful aperture angle max. 60° (front-end reading window)

Scanning/decoding frequency

600 to 1,200 Hz

Resolution (typically)

0.25 to 1.0 mm (9.8 to 39.4 mil)

0.17 to 0.4 mm (6.7 to 15.7 mil)

0.35 to 1.2 mm (13.8 to 47.3 mil)

Reading ranges see Page 10-3 see Page 10-16 see Page 10-27

Bar code print contrast (PCS)

≥ 60 %

Ambient light compatibility

2,000 lx (on bar code)

No. of bar codes per scan

1 to 12 (standard decoder), 1 to 5 (SMART decoder)

No. of bar codes per reading interval

2)

1 to 50 (autodiscriminating)

Bar code types

Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved

Bar code length max. 50 characters (max. 600 characters across all bar codes per reading interval)

Print ratio

2:1 to 3:1

No. of multiple reads

1 to 99

Optical indicators

4 x LEDs (status indicators)

Reading pulse

"Sensor" switching input (Option: additionally "IN 4")/Free-running/Serial interface/ Object Polling/OTS

"Host" data interface

RS 232 or RS 422/485, variable data output format

Data transmission rate

300 to 57,600 bd

Protocols

SICK Standard, SICK Network and 3 964(R)

Physical configurations

Stand-alone, SICK Network (Bus), Daisy Chain (Pass-Through or Master/Slave)

"CAN" data interface Data transmission rate

CANopen protocol, CAN Scanner Network 10 kbit/s to 1 Mbit/s

"Terminal" data interface

RS 232, 9,600 bd, 8 data bits, no parity, 1 stop bit, fixed output format

Switching inputs

6 ( Sensor, "IN 0" to "IN 4") – optodecoupled, Vimax = +30 V, non-interchangeable, can be connected to PNP outputs – "Sensor" (reading pulse): max. internal delay 30 ms, reduced max. 2 to 6 ms – "IN 0" to "IN 4": focus position switching, IN 3 and IN 4: selectable function, max. internal delay 30 ms

Switching outputs

4 ("Result 1" to "Result 4") – PNP, short-circuit-proof, variable pulse duration (static; resolution 10 to 990 ms or 100 to 9,900 ms) – Variable output function for result status

Electrical connections

1 x 15-pin D Sub HD plug, 1 x 15-pin D Sub HD socket

1) Default setting, in Reading mode with the "Switching input sensor" and "Serial interface pulse" types. 2) Reading interval: time window generated internally for evaluating the code.

Table 9-1: Technical specifications of the CLV 490-0010/-2010/-6010

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

9-1

Page 164

Chapter 9

Technical data

Operating Instructions CLV 490 Bar Code Scanner

Type

CLV 490-0010 (Standard density)

CLV 490-2010 (High density)

CLV 490-6010 (Low density)

Operating voltage/power consumption

18 to 30 V DC pursuant to IEC 364-4-41 / typically 11 W, max. 16 W

Housing

Aluminium die-cast, does not represent a problem in paint shops

Enclosure rating/protection class

IP 653) (to DIN 40 050)/class 3(to VDE 0106/IEC 1010-1)

EMC/vibration/shock tested to EN 61000-6-2, 61000-6-3/to EN 60068-2-6/to EN 60068-2-27

Weight approx. 1.5 kg (approx. 3.3 lb)

Ambient operating/storage temperature

0 to +40 °C/–20 to +70 °C (+32 to +104 °F/–4 to +158 °F)

Max. rel. humidity

90 %, non condensing

Color

SICK blue (RAL 5012)

3) With plug cover or plug cover with parameter memory

Table 9-1: Technical specifications of the CLV 490-0010/-2010/-6010

9.2

Data sheet CLV 490-1010/-3010/-7010 bar code scanner

Technical data as CLV 490-0010/-2010/-6010 with the following exceptions: Type

CLV 490-1010 (Standard density)

Design line scanner with oscillating mirror

Reading window side

Angle of emergence

CLV 490-3010 (High density)

CLV 490-7010 (Low density)

105° (center position CW = 50)

Trigger source for focus control also: oscillating mirror reversal points

Useful aperture angle max. 50°

Oscillating mirror functions permanent (variable position)/oscillating (amplitude per DC variable or fixed)/One-Shot1)

Oscillating frequency

0.2 to 4 Hz

Max. angle of deflection max. ±20° (±40 CW), (set with software)

Reading ranges see Page 10-9 see Page 10-21 see Page 10-31 see Page 10-26 see Page 10-33

Deflection ranges see Page 10-15

Operating voltage/power consumption

18 to 30 V DC pursuant to IEC 364-4-41/ typically 13 W, max 18 W

Weight approx. 2.2 kg (approx. 4.84 lb)

1)

One-Shot: one-off oscillating movement per reading pulse (start position and velocity can be selected for forward and return phase)

Table 9-2: Technical specifications of the CLV 490-1010/-3010/-7010

9.3

Data sheet CLV 490-0011 /-2011/-6011 bar code scanner

Technical data as CLV 490-0010/-2010/-6010 with the following exceptions: Type

CLV 490-0011 (Standard density)

CLV 490-2011 (High density)

CLV 490-6011 (Low density)

Design line scanner with heater

Switching on function/temperature graph see Chapter 10.4 Optional heating, Page 10-40

Power-on delay

35 to 40 min (at 24 V DC and min. ambient operating temperature –35 °C (–31 °F))

Operating voltage

24 V DC +20 %/–10 % pursuant to IEC 364-4-41

Power consumption typically 75 W, max 90 W

Required cross-section min. 0.75 mm2 (20 AWG) (for power supply)

Weight approx. 1.5 kg (approx. 3.3 lb)

Ambient operating/storage temperature

–35 to +35 °C/–20 to +70 °C (–31 to +95 °F/–4 to +158 °F)

Table 9-3: Technical specifications of the CLV 490-0011/-2011/-6011

9-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 165

Operating Instructions

Technical data

Chapter 9

CLV 490 Bar Code Scanner

9.4

Data sheet CLV 490-1011/-3011/-7011 bar code scanner

Technical data as CLV 490-1010/-2010/-6010 with the following exceptions: Type

CLV 490-1011 (Standard density)

CLV 490-3011 (High density)

Design line scanner with oscillating mirror and heater

Switching on function/temperature graph see Chapter 10.4 Optional heating, Page 10-40

CLV 490-7011 (Low density)

Power-on delay

35 to 40 min (at 24 V DC and min. ambient operating temperature –35 °C (–31 °F))

Operating voltage

24 V DC +20 %/–10 % pursuant to IEC 364-4-41

Power consumption typically 75 W, max 90 W

Required cross-section min. 0.75 mm2 (20 AWG) (for power supply)

Weight approx. 2.2 kg (approx. 4.84 lb)

Ambient operating/storage temperature

–35 to +35 °C/–20 to +70 °C (–31 to +95 °F/–4 to +158 °F)

Table 9-4: Technical specifications of the CLV 490-1011/-3011/-7011

9.5

Dimensioned drawings – CLV

9.5.1

Line scanner (standard device) without /with heater

CLV 490-0010 CLV 490-0011 CLV 490-2010 CLV 490-2011 CLV 490-6010 CLV 490-6011

All dimensions in mm (in) Fig. 9-1:

Dimensions of the CLV 490 line scanner, front reading window

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

9-3

Page 166

Technical data

Chapter 9

Operating Instructions CLV 490 Bar Code Scanner

9.5.2

Line scanner with oscillating mirror (without/with heater)

CLV 490-1010 CLV 490-1011 CLV 490-3010 CLV 490-3011 CLV 490-7010 CLV 490-7011

All dimensions in mm (in)

Fig. 9-2:

9-4

Dimensions of the CLV 490: line scanner with oscillating mirror, side reading window

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004