Page 167
Appendix
Operating Instructions
Chapter 10
CLV 490 Bar Code Scanner
10
Appendix 10.1
Overview
The appendix contains the following additional information: •
Specification diagrams – Line scanner (all variants) – Line scanner with oscillating mirror (all variants)
•
Installation and operating instructions for the external parameter memory
•
Optional heating (temperature graph/ switching on function)
•
System messages
•
Installation and operating instructions for the PC-based "CLV-Setup" program
•
Configuring a CLV using command strings
•
Parameter value calculations for configuring the CLV
•
Tables
•
Discussion of a parameterization example
•
Special applications and procedures
•
Instructions for replacing a CLV (copying the parameter set)
•
Accessories
•
Dimensioned drawings of the accessories
•
Notes on supplementary documentation
•
Glossary
•
Copy of the EC-Declaration of Conformity
•
Index
•
Scannable sample bar codes
10.2
Specification diagrams
10.2.1
Reading conditions for all diagrams
Test code
Code 128
Print ratio
> 90 %
Tilt
±45°
Ambient light
< 2,000 lx
Good Read rate
> 75 %
Table 10-1: Reading conditions for specification diagrams
Note
8 009 993/O824/20-12-2004
The min. and max. reading distances are measured radially by the CLV.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-1
Page 168
Chapter 10
Appendix
Operating Instructions CLV 490 Bar Code Scanner
10.2.2
Overview of diagrams
Line scanner CLV-Type
Resolution
Scanning method Diagram
Page
CLV 490-0010/-0011 Standard density Line scanner
Reading field height/resolution as a function of reading distance 10-3
CLV 490-0010/-0011 Standard density Line scanner
Min. and max. reading distance (DOF) for 0.35 mm/40°
10-4
CLV 490-0010/-0011 Standard density Line scanner
Min. and max. reading distance (DOF) for 0.35 mm/56°
10-5
CLV 490-0010/-0011 Standard density Line scanner
Min. and max. reading distance (DOF) for 0.50 mm/40°
10-6
CLV 490-0010/-0011 Standard density Line scanner
Min. and max. reading distance (DOF) for 0.50 mm/56°
10-7 10-8
CLV 490-0010/-0011 Standard density Line scanner
Characteristics field scanning frequency
CLV 490-2010/-2011 High density
Line scanner
Reading field height/resolution as a function of reading distance 10-16
CLV 490-2010/-2011 High density
Line scanner
Min. and max. reading distance (DOF) for 0.25 mm/40°
10-17
CLV 490-2010/-2011 High density
Line scanner
Min. and max. reading distance (DOF) for 0.35 mm/40°
10-18
CLV 490-2010/-2011 High density
Line scanner
Min. and max. reading distance (DOF) for 0.35 mm/56°
10-19
CLV 490-2010/-2011 High density
Line scanner
Characteristics field scanning frequency
10-20
CLV 490-6010/-6011 Low density
Line scanner
Reading field height/Tilt as a function of reading distance for 0.5 mm
10-27
CLV 490-6010/-6011 Low density
Line scanner
Min. and max. reading distance (DOF) for 0.5 mm/40°
10-28
CLV 490-6010/-6011 Low density
Line scanner
Min. and max. reading distance (DOF) for 0.5 mm/60°
10-29
CLV 490-6010/-6011 Low density
Line scanner
Characteristics field scanning frequency
10-30
Table 10-2: Overview of specification diagrams for the line scanner
Line scanner with oscillating mirror CLV-Type
Resolution
Scanning method
Diagram
Page
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Reading field height/resolution as a function of reading distance
10-9
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40°
10-10
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50°
10-11
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/40°
10-12
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/50°
10-13
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Characteristics field scanning frequency
10-14
CLV 490-1010/-1011 Standard density L.s. with osci. mirror Deflection range
10-15
CLV 490-3010/-3011 High density
L.s. with osci. mirror Reading field height/resolution as a function of reading distance
10-21
CLV 490-3010/-3011 High density
L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.25 mm/40°
10-22
CLV 490-3010/-3011 High density
L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40°
10-23
CLV 490-3010/-3011 High density
L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50°
10-24
CLV 490-3010/-3011 High density
L.s. with osci. mirror Characteristics field scanning frequency
10-25
CLV 490-3010/-3011 High density
L.s. with osci. mirror Deflection range
10-26
CLV 490-7010/-7011 Low density
L.s. with osci. mirror Reading field height/Tilt as a function of reading distance for 0.5 mm
10-31
CLV 490-7010/-7011 Low density
L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/40°
10-28
CLV 490-7010/-7011 Low density
L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/50°
10-29
CLV 490-7010/-7011 Low density
L.s. with osci. mirror Characteristics field scanning frequency
10-32
CLV 490-7010/-7011 Low density
L.s. with osci. mirror Deflection range
10-33
Table 10-3: Overview of specification diagrams for the line scanner with oscillating mirror
10-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 169
Appendix
Operating Instructions
Chapter 10
CLV 490 Bar Code Scanner
Reading distance
Reading conditions: see Table 10-1, Page 10-1
Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8
0.50 mm (19.7 mil)
0.35 mm (13.8 mil)
0.30 mm (11.8 mil)
Standard density: Reading performance data of line scanner
α= ang le Ape rture le ang rture e p A
α=
40°
40°
Dimensions in mm (in) Reading field height
Line scanner (front reading window):
CLV 490-0010/-0011
Resolution:
10.2.3
Fig. 10-1:
CLV 490-0010/-0011 (Standard density): Reading field height as a function of the reading distance and resolution
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-3
Page 170
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner r
Line scanner (front reading window):
CLV 490-0010/-0011
Resolution: 0.35 mm (13.8 mil) Aperture angle: 40°
Radial reading distance
Dimensions in mm (in)
max. reading distance min. reading distance
Reading ranges from approx. 1,540 mm (60.7 in) focus position are typical values!
Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8
Fig. 10-2:
10-4
Reading conditions: see Table 10-1, Page 10-1
CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 40°
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 171
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
Line scanner (front reading window):
CLV 490-0010/-0011
Resolution: 0.35 mm (13.8 mil) Aperture angle: 56°
Radial reading distance
Dimensions in mm (in)
max. reading distance min. reading distance
Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8
Fig. 10-3:
Reading conditions: see Table 10-1, Page 10-1
CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 56°
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-5
Page 172
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
Line scanner (front reading window):
CLV 490-0010/-0011
Resolution: 0.50 mm (19.7 mil) Aperture angle: 40°
Radial reading distance max. reading distance Dimensions in mm (in)
min. reading distance
Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8
Fig. 10-4:
10-6
Reading conditions: see Table 10-1, Page 10-1
CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.50 mm (19.7 mil) and an aperture angle of α = 40°
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 173
Operating Instructions
Appendix
Chapter 10
CLV 490 Bar Code Scanner
Line scanner (front reading window):
CLV 490-0010/-0011
Radial reading distance
Resolution: 0.50 mm (19.7 mil) Aperture angle: 56°
Dimensions in mm (in)
max. reading distance min. reading distance
Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8 Fig. 10-5:
Reading conditions: see Table 10-1, Page 10-1
CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.50 mm (19.7 mil) and an aperture angle of α = 56°
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-7
Page 174
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
Line scanner (front reading window): CLV 490-0010/-0011 Dimensions in mm (in) Scanning frequency (Hz)
Radial reading distance Resolution: 0.35 mm (13.8 mil) 0.50 mm (19.7 mil)
Fig. 10-6:
10-8
Reading conditions: see Table 10-1, Page 10-1
Characteristics field CLV 490-0010/-0011 (Standard density): Scanning frequency as a function of the radial reading distance and resolution
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 175
Appendix
Operating Instructions
Chapter 10
CLV 490 Bar Code Scanner
Reading distance
Reading conditions: see Table 10-1, Page 10-1
Characteristics field scanning frequency/ reading distance: see Fig. 10-12, Page 10-14
0.50 mm (19.7 mil)
0.35 mm (13.8mil)
0.30 mm (11.8 mil)
Standard density: Reading performance data of line scanner with oscillating mirror
=4 0°
0°
Ape rture ang le α
=4 α ngle re a u t r Ape
Dimensions in mm (in) Reading field height
Line scanner with oscillating mirror (side reading window):
CLV 490-1010/-1011
Resolution:
10.2.4
Fig. 10-7:
CLV 490-1010/-1011 (Standard density): Reading field height as a function of the reading distance and resolution
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-9
Page 176
Appendix
Chapter 10
Operating Instructions CLV 490 Bar Code Scanner
Line scanner with oscillating mirror (side reading window): CLV 490-1010/-1011
Resolution: 0.35 mm (13.8 mil) Aperture angle: 40°
Radial reading distance
Dimensions in mm (in)
max. reading distance min. reading distance
Reading ranges from approx. 1,440 mm (56.7 in) focus position are typical values!
Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-12, Page 10-14
Fig. 10-8:
10-10
Reading conditions: see Table 10-1, Page 10-1
CLV 490-1010/-1011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 40°
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004