Page 167

Appendix

Operating Instructions

Chapter 10

CLV 490 Bar Code Scanner

10

Appendix 10.1

Overview

The appendix contains the following additional information: •

Specification diagrams – Line scanner (all variants) – Line scanner with oscillating mirror (all variants)

•

Installation and operating instructions for the external parameter memory

•

Optional heating (temperature graph/ switching on function)

•

System messages

•

Installation and operating instructions for the PC-based "CLV-Setup" program

•

Configuring a CLV using command strings

•

Parameter value calculations for configuring the CLV

•

Tables

•

Discussion of a parameterization example

•

Special applications and procedures

•

Instructions for replacing a CLV (copying the parameter set)

•

Accessories

•

Dimensioned drawings of the accessories

•

Notes on supplementary documentation

•

Glossary

•

Copy of the EC-Declaration of Conformity

•

Index

•

Scannable sample bar codes

10.2

Specification diagrams

10.2.1

Reading conditions for all diagrams

Test code

Code 128

Print ratio

> 90 %

Tilt

±45°

Ambient light

< 2,000 lx

Good Read rate

> 75 %

Table 10-1: Reading conditions for specification diagrams

Note

8 009 993/O824/20-12-2004

The min. and max. reading distances are measured radially by the CLV.

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-1

Page 168

Chapter 10

Appendix

Operating Instructions CLV 490 Bar Code Scanner

10.2.2

Overview of diagrams

Line scanner CLV-Type

Resolution

Scanning method Diagram

Page

CLV 490-0010/-0011 Standard density Line scanner

Reading field height/resolution as a function of reading distance 10-3

CLV 490-0010/-0011 Standard density Line scanner

Min. and max. reading distance (DOF) for 0.35 mm/40°

10-4

CLV 490-0010/-0011 Standard density Line scanner

Min. and max. reading distance (DOF) for 0.35 mm/56°

10-5

CLV 490-0010/-0011 Standard density Line scanner

Min. and max. reading distance (DOF) for 0.50 mm/40°

10-6

CLV 490-0010/-0011 Standard density Line scanner

Min. and max. reading distance (DOF) for 0.50 mm/56°

10-7 10-8

CLV 490-0010/-0011 Standard density Line scanner

Characteristics field scanning frequency

CLV 490-2010/-2011 High density

Line scanner

Reading field height/resolution as a function of reading distance 10-16

CLV 490-2010/-2011 High density

Line scanner

Min. and max. reading distance (DOF) for 0.25 mm/40°

10-17

CLV 490-2010/-2011 High density

Line scanner

Min. and max. reading distance (DOF) for 0.35 mm/40°

10-18

CLV 490-2010/-2011 High density

Line scanner

Min. and max. reading distance (DOF) for 0.35 mm/56°

10-19

CLV 490-2010/-2011 High density

Line scanner

Characteristics field scanning frequency

10-20

CLV 490-6010/-6011 Low density

Line scanner

Reading field height/Tilt as a function of reading distance for 0.5 mm

10-27

CLV 490-6010/-6011 Low density

Line scanner

Min. and max. reading distance (DOF) for 0.5 mm/40°

10-28

CLV 490-6010/-6011 Low density

Line scanner

Min. and max. reading distance (DOF) for 0.5 mm/60°

10-29

CLV 490-6010/-6011 Low density

Line scanner

Characteristics field scanning frequency

10-30

Table 10-2: Overview of specification diagrams for the line scanner

Line scanner with oscillating mirror CLV-Type

Resolution

Scanning method

Diagram

Page

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Reading field height/resolution as a function of reading distance

10-9

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40°

10-10

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50°

10-11

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/40°

10-12

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.50 mm/50°

10-13

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Characteristics field scanning frequency

10-14

CLV 490-1010/-1011 Standard density L.s. with osci. mirror Deflection range

10-15

CLV 490-3010/-3011 High density

L.s. with osci. mirror Reading field height/resolution as a function of reading distance

10-21

CLV 490-3010/-3011 High density

L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.25 mm/40°

10-22

CLV 490-3010/-3011 High density

L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/40°

10-23

CLV 490-3010/-3011 High density

L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.35 mm/50°

10-24

CLV 490-3010/-3011 High density

L.s. with osci. mirror Characteristics field scanning frequency

10-25

CLV 490-3010/-3011 High density

L.s. with osci. mirror Deflection range

10-26

CLV 490-7010/-7011 Low density

L.s. with osci. mirror Reading field height/Tilt as a function of reading distance for 0.5 mm

10-31

CLV 490-7010/-7011 Low density

L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/40°

10-28

CLV 490-7010/-7011 Low density

L.s. with osci. mirror Min. and max. reading distance (DOF) for 0.5 mm/50°

10-29

CLV 490-7010/-7011 Low density

L.s. with osci. mirror Characteristics field scanning frequency

10-32

CLV 490-7010/-7011 Low density

L.s. with osci. mirror Deflection range

10-33

Table 10-3: Overview of specification diagrams for the line scanner with oscillating mirror

10-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 169

Appendix

Operating Instructions

Chapter 10

CLV 490 Bar Code Scanner

Reading distance

Reading conditions: see Table 10-1, Page 10-1

Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8

0.50 mm (19.7 mil)

0.35 mm (13.8 mil)

0.30 mm (11.8 mil)

Standard density: Reading performance data of line scanner

α= ang le Ape rture le ang rture e p A

α=

40°

40°

Dimensions in mm (in) Reading field height

Line scanner (front reading window):

CLV 490-0010/-0011

Resolution:

10.2.3

Fig. 10-1:

CLV 490-0010/-0011 (Standard density): Reading field height as a function of the reading distance and resolution

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-3

Page 170

Appendix

Chapter 10

Operating Instructions CLV 490 Bar Code Scanner r

Line scanner (front reading window):

CLV 490-0010/-0011

Resolution: 0.35 mm (13.8 mil) Aperture angle: 40°

Radial reading distance

Dimensions in mm (in)

max. reading distance min. reading distance

Reading ranges from approx. 1,540 mm (60.7 in) focus position are typical values!

Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8

Fig. 10-2:

10-4

Reading conditions: see Table 10-1, Page 10-1

CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 40°

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 171

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner

Line scanner (front reading window):

CLV 490-0010/-0011

Resolution: 0.35 mm (13.8 mil) Aperture angle: 56°

Radial reading distance

Dimensions in mm (in)

max. reading distance min. reading distance

Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8

Fig. 10-3:

Reading conditions: see Table 10-1, Page 10-1

CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 56°

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-5

Page 172

Appendix

Chapter 10

Operating Instructions CLV 490 Bar Code Scanner

Line scanner (front reading window):

CLV 490-0010/-0011

Resolution: 0.50 mm (19.7 mil) Aperture angle: 40°

Radial reading distance max. reading distance Dimensions in mm (in)

min. reading distance

Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8

Fig. 10-4:

10-6

Reading conditions: see Table 10-1, Page 10-1

CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.50 mm (19.7 mil) and an aperture angle of α = 40°

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 173

Operating Instructions

Appendix

Chapter 10

CLV 490 Bar Code Scanner

Line scanner (front reading window):

CLV 490-0010/-0011

Radial reading distance

Resolution: 0.50 mm (19.7 mil) Aperture angle: 56°

Dimensions in mm (in)

max. reading distance min. reading distance

Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-6, Page 10-8 Fig. 10-5:

Reading conditions: see Table 10-1, Page 10-1

CLV 490-0010/-0011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.50 mm (19.7 mil) and an aperture angle of α = 56°

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-7

Page 174

Appendix

Chapter 10

Operating Instructions CLV 490 Bar Code Scanner

Line scanner (front reading window): CLV 490-0010/-0011 Dimensions in mm (in) Scanning frequency (Hz)

Radial reading distance Resolution: 0.35 mm (13.8 mil) 0.50 mm (19.7 mil)

Fig. 10-6:

10-8

Reading conditions: see Table 10-1, Page 10-1

Characteristics field CLV 490-0010/-0011 (Standard density): Scanning frequency as a function of the radial reading distance and resolution

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 175

Appendix

Operating Instructions

Chapter 10

CLV 490 Bar Code Scanner

Reading distance

Reading conditions: see Table 10-1, Page 10-1

Characteristics field scanning frequency/ reading distance: see Fig. 10-12, Page 10-14

0.50 mm (19.7 mil)

0.35 mm (13.8mil)

0.30 mm (11.8 mil)

Standard density: Reading performance data of line scanner with oscillating mirror

=4 0°

0°

Ape rture ang le α

=4 α ngle re a u t r Ape

Dimensions in mm (in) Reading field height

Line scanner with oscillating mirror (side reading window):

CLV 490-1010/-1011

Resolution:

10.2.4

Fig. 10-7:

CLV 490-1010/-1011 (Standard density): Reading field height as a function of the reading distance and resolution

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-9

Page 176

Appendix

Chapter 10

Operating Instructions CLV 490 Bar Code Scanner

Line scanner with oscillating mirror (side reading window): CLV 490-1010/-1011

Resolution: 0.35 mm (13.8 mil) Aperture angle: 40°

Radial reading distance

Dimensions in mm (in)

max. reading distance min. reading distance

Reading ranges from approx. 1,440 mm (56.7 in) focus position are typical values!

Focus position Characteristics field scanning frequency/ reading distance: see Fig. 10-12, Page 10-14

Fig. 10-8:

10-10

Reading conditions: see Table 10-1, Page 10-1

CLV 490-1010/-1011 (Standard density): Min. and Max. reading distance (measured radially) as a function of the focus position at a resolution of 0.35 mm (13.8 mil) and an aperture angle of α = 40°

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004