Operating Instructions: CLV490 Bar Code Scanner, Advanced Line: 5 Electrical installation, pages 51 to 60

Pages 51 to 60 of 266, from Operating Instructions: CLV490 Bar Code Scanner, Advanced Line

The original document is the PDF (5.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV490

Page 51

Electrical installation

Operating Instructions

Chapter 5

CLV 490 Bar Code Scanner

5

Electrical installation 5.1

Installation sequence

•

Connect the CLV to a CDB 420 or CDM 490 Connection Module, or using a customerspecific wiring configuration

•

Connect the data and function interfaces of the CLV in the module

•

Connect the PC to the Connection Module (at the terminal interface on the CLV)

•

Connect the power supply to the Connection Module

5.1.1

SICK Connection Modules (overview)

CLV Type

Temperature range

CLV without heater

0 to +40 °C CDB 420-001 (+32 to +104 °F) CDB 420-101

CLV with heater

Connection module

–35 to +35 °C (–31 to +95 °F)

Purpose see chapter

– Connecting one CLV – 1 x 15-pin D Sub HD socket, 4 x cable gland (CDB 420-101: 2 x cable gland, 2 x M12 plug connection (1 x plug, 1 x socket)) – Operating voltage 18 to 30 V DC – Enclosure rating max. IP 65

5.2.3

CDM 490-0001

– Connecting one CLV – 1 x 15-pin D Sub HD plug, 1 x socket, 6 x cable gland – Operating voltage 18 to 30 V DC – Enclosure rating max. IP 65

5.2.4

CDM 490-0001

– Connecting one CLV – 1 x 15-pin D Sub HD plug, 1 x socket, 6 x cable gland – Operating voltage 24 V DC +20 %/–10 % – Enclosure rating max. IP 65 (with connector cover)

5.2.4

Table 5-1: Connection Modules for the CLV

For technical data on the modules see Chapter 10.13.2 Connection modules, Page 10-75.

5.2

Electrical connections and cables

The electrical connections on the CLV consist of two 15-pin D Sub HD connections on the housing, one plug, and one socket. These connections are used to route the following interfaces: •

Three data serial interfaces (host interface, CAN interface 1 and 2, terminal interface)

•

Six switching inputs (external reading pulse and multifunctional inputs)

•

Four switching outputs (for result status function, for connecting to a PLC for example)

•

Power supply

5.2.1

Wire cross-sections

CLV without heater: ¾

8 009 993/O824/20-12-2004

All connections must be wired with copper cables with a minimum wire diameter of 0.15 mm2 (approx. 26 AWG)!

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-1

Page 52

Electrical installation

Chapter 5

Operating Instructions CLV 490 Bar Code Scanner

CLV with heater: ¾

Connect the power supply terminals (Pin 1/Pin 5) using copper wires with a minimum cross-section of 0.75 mm2 (approx. 20 AWG) at a maximum length of 10 m (32.8 ft)!

5.2.2

Prefabricated cables (overview)

CLV Type

Temperature range

Connection module

Optional cables

Length

Type

CLV without heater

0 to +40 °C (+32 to +104 °F)

CDB 420

1 x no. 2 027 046 or

3m (3.84 ft)

Connector cover (IP 65) to 15-pin plug

1 x no. 2 030 023

3m (3.84 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug

2 x no. 2 020 302 or

3m (3.84 ft)

Connection cable (15-pin plug/socket)

2 x no. 2 021 815 or

10 m (32.8 ft)

Connection cable (15-pin plug/socket)

1 x no. 2 020 307

3m (3.84 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket

1 x no. 2 020 303 +

3m (3.84 ft) 3m (3.84 ft)

Connection cable with 15-pin socket/open end

1 x no. 2 020 981 or

3m (3.84 ft)

Connector cover (IP 65) with parameter memory to two cables with open ends

1 x no. 2 021 267

3m (3.84 ft)

Connector cover (IP 65) to two cables with open ends

1 x no. 2 033 126 or

10 m (32.8 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug and cable with open end (power supply), suitable for track chain use

1 x no. 2 033 127

15 m (49.2 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug and cable with open end (power supply), suitable for track chain use

1 x no. 2 030 065 or

3m (3.84 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket as well as cable with open end (power supply), suitable for track chain use

1 x no. 2 031 034 or

10 m (32.8 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket as well as cable with open end (power supply), suitable for track chain use

1 x no. 2 027 543

3m (3.84 ft)

Connector cover (IP 65) with parameter memory to 15-pin plug (with wires for CAN interface 1 (IN/OUT)) and 15-pin socket

1 x no. 2 021 267

3m (3.84 ft)

Connector cover (IP 65) to two cables with open ends

CDM 490

Non-Sick Power pack

1 x no. 2 020 264 or

CLV with heater

–35 to +35 °C CDB 420 (–31 to +95 °F)

CDM 490

Non-Sick Power pack

Connection cable with 15-pin plug/open end

Table 5-2: Cables for connecting the CLV

For technical data on the cables, see Chapter 10.13.4 Cables, external parameter memories in connector cover, connector covers, Page 10-77. For function of the external parameter memory in the connector cover see Chapter 10.3 Installing and operating the external parameter memory (connector cover), Page 10-34.

5-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 53

Electrical installation

Operating Instructions

Chapter 5

CLV 490 Bar Code Scanner

5.2.3

Connections/cables for the CDB 420 Connection Modules

The CDB 420 Connection Module is suitable for connecting one CLV without/with heater to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point) or to integrate the device in a SICK CAN Scanner Network. The module is available in two variants and can be operated without optional modules (see below) with an operating temperature to –35 °C (–31 °F). For technical data see Chapter 10.13.2 Connection modules, Page 10-75. Optional modules for building-in into the CDB 420: •

CMC 400 Connection Module Cloning for saving the parameters of the CLV externally

Because only one 15-pin D Sub HD socket respectively screw terminal strips for the power supply via cable glands are available for connecting the CLV to the CDB 420, the number of signals which can be connected using the terminal strips in the CDB 420 are limited. Fig. 5-1 shows the connection principle of the CDB 420. CLV 490 CDB 420 connection module AUX

Photoelectric switch Reading pulse

PC

“Aux”

HOST/PLC

Photoelectric switch Focal position Trigger One-Shot Conveyor increment End of reading interval

“Result 1 ... 2” “IN 0” CAN bus

“Result 1 ... 2” “IN 0”

PLC

18 to 30 V DC

– – Cable if required (if necessary) Fig. 5-1:

Block diagram: Connection of the CLV 490 to the CDB 420 connection module

The procedures for connecting and configuring the connection module are described in the "CDB 420 Connection Module" Operating Instructions (order no. 8 010 001, German/ English). Note

Diagrams showing you how to connect the CDB 420 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM). Connecting the CLV to the CDB 420 a) CLV without heater The following connection cables with connector cover for the CLV can be used: No. 2 027 046 (3 m (3.84 ft)) or no. 2 030 023 (3 m (3.84 ft)). The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!).

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-3

Page 54

Electrical installation

Chapter 5

Operating Instructions CLV 490 Bar Code Scanner b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 033 126 (10 m (32.8 ft)) or no. 2 033 127 (15 m (49.2 ft), however not when the RS 232 host interface is used)). The cables must not be extended! If longer cables are required, the entire power supply system (Pin 1/Pin 5) must be connected with a wire cross-section of at least 0.75 mm2 (approx. 20 AWG) with a maximum length of 10 m (32.8 ft). Note

To avoid strain on the power supply lines when connecting the CLV with heater to the CDB 420, please make sure to use the correct cable wire diameters for the incoming cables of the power supply to the CDB 420 and to use corresponding fuses. Use only the screw terminals 1 to 4 for connecting the power supply. The input voltage connected to the screw terminals 1 and 2 is directly available on the screw terminals 3 and 4 for connecting the CLV 490, independent of the S1 switch (Power). Chapter 5.3 Connector pin assignment, Page 5-7 shows the pin assignments of the 15-pin plug and the open cable ends on the side of the CDB 420.

5-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 55

Electrical installation

Operating Instructions

Chapter 5

CLV 490 Bar Code Scanner

5.2.4

Connections/cables for the CDM 490 Connection Module

The CDM 490 Connection Module is suitable for connecting one CLV without/with heater to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point), to integrate the device in a SICK CAN Scanner Network or in field bus systems. The module is available in one variant and can be operated without optional modules (see below) with an operating temperature to –35 °C (–31 °F). For technical data see Chapter 10.13.2 Connection modules, Page 10-75. Optional modules for building-in into the CDM 490: •

CMP 490 Power Supply Module in optional cover for supplying the CLV without heater directly from an AC power line

•

CMC 400 Connection Module Cloning for saving the parameters of the CLV externally

•

CMD 400 Connection Display Module in optional cover for representation of reading results and reading diagnosis data

•

CMF 400 Bus Modules (field bus gateways) for connecting the CLV to Profibus DP, DeviceNet or Ethernet TCP/IP

The CMP 490 Power Supply Module can not be used if the CMD 400 Display Module has always been built-in (or vice versa). For detailed description of function and installation see the corresponding Fitting/Operating Instructions (see Chapter 10.15 Supplementary documentation, Page 10-82). Fig. 5-2 shows the connection principle of the CDM 490. CLV 490 CDM 490 connection module AUX

Photoelectric switch Reading pulse

PC

“Aux”

HOST/PLC

Photoelectric switch Focal position Trigger One-Shot Conveyor increment End of reading interval

CAN bus PLC 18 to 30 V DC

– – Cable if required (if necessary) Fig. 5-2:

Block diagram: Connection of the CLV 490 to the CDM 490 connection module

The procedures for connecting and configuring the connection module are described in the "CDM 490 Connection Module" Operating Instructions (order no. 8 010 005, German/ English). Note

8 009 993/O824/20-12-2004

Diagrams showing you how to connect the CDM 490 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-5

Page 56

Electrical installation

Chapter 5

Operating Instructions CLV 490 Bar Code Scanner be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM). Connecting the CLV to the CDM 490 a) CLV without heater The following connection cables without connector cover for the CLV can be used: 2 x no. 2 020 302 (3 m (3.84 ft)) or 2 x no. 2 021 815 (10 m (32.8 ft)). Pin assignment identical to device connection of the CLV. The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!). The following connection cables with connector cover for the CLV can be used: No. 2 020 307 (3 m (3.84 ft)). b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 030 065 (3 m (3.84 ft)), no. 2 031 034 (10 m (32.8 ft)) or no. 2 027 543 (3 m (3.84 ft)). The cables must not be extended! If longer cables are required, the entire power supply system (Pin 1/Pin 5) must be connected with a wire cross-section of at least 0.75 mm2 (approx. 20 AWG) with a maximum length of 10 m (32.8 ft). Note

To avoid strain on the power supply lines when connecting the CLV with heater to the CDM 490, please make sure to use the correct cable wire diameters for the incoming cables of the power supply to the CDM 490 and to use corresponding fuses. Use only the screw terminals 1 to 4 for connecting the power supply. The input voltage connected to the screw terminals 1 and 2 is directly available on the screw terminal 3 and 4 for connecting the CLV 490, independent of the S1 switch (Power). Chapter 5.3 Connector pin assignment, Page 5-7 shows the pin assignments of the 15-pin plug connections and the open cable ends on the side of the CDM 490. 5.2.5

Connections/cables for a non-SICK power pack

For connecting the CLV to a non-SICK power pack cables with open ends on the side of the power pack are available. a) CLV without heater: The following connection cables without connector cover for the CLV can be used: No. 2 020 303 (3 m (3.84 ft)) and no. 2 020 264 (3 m (3.84 ft)). Pin assignment identical to device connection of the CLV. The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!). The following connection cables with connector cover for the CLV can be used: No. 2 020 981 (3 m (3.84 ft)) or no. 2 021 267 (3 m (3.84 ft)). b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 021 267 (3 m (3.84 ft)). The cable can be used with temperatures up to max. –50 °C (–58 °F) if the CLV is stationary and the cables are not moved. If the cables are moved due to changes in the position of the CLV, the temperature must not drop below max. –40 °C (–40 °F).

5-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 57

Electrical installation

Operating Instructions

Chapter 5

CLV 490 Bar Code Scanner

5.3

Connector pin assignment

5.3.1

Terminals on the CLV

Device plug: "Host/Term" connection 6 1

5 10

Pin 1)

11

1 2 3 4 5 6 7

15

8 9 10 11 12 13 14 15 Housing

Signal VS

Function Supply voltage

RxD (RS 232), Terminal TxD (RS 232), Terminal Term (RS 422/485) GND RD+ (RS 422/485), Host RD– (RS 422/485), Host RxD (RS 232), Host TD+ (RS 422/485), Host TD– (RS 422/485), Host TxD (RS 232), Host CAN H Reserved CAN2 H CAN2 L Reserved CAN L –

Terminal interface (receiver) Terminal interface (transmitter) Termination host interface Ground Host interface (receiver+) Host interface (receiver–) Host interface (transmitter+) Host interface (transmitter–) CAN interface 1 (IN/OUT) – CAN interface 2 (IN/OUT) CAN interface 2 (IN/OUT) – CAN interface 1 (IN/OUT) Shield

1) Pin 1 is jumpered with Pin 1 of the "I/O" connection in the CLV

Table 5-3: Pin assignment of the 15-pin D Sub HD "Host/Term" plug

Device socket: "I/O" connection L

10 5

1

6

Pin

Signal

Function

VS

Supply voltage

2

IN 1

Switching input (trigger for focus control)

3

Sensor

Switching input (external reading pulse)

4

Result 1

Switching output, variable function

5

GND

Ground

6

IN 0

Switching input (trigger for focus control)

1 15

11

1)

7

IN 2

Switching input (trigger for focus control)

8

Result 2

Switching output, variable function

9

INGND

Common ground for all inputs

10

Result 3

Switching output, variable function

11

IN 3

Switching input, variable function

12

IN 4

Switching input, variable function

13

I2C SDA

I2C Bus (for external parameter memory)

14

I2C SCL

I2C Bus (for external parameter memory)

15

Result 4

Switching output, variable function

Housing

–

Shield

1) Pin 1 is jumpered with Pin 1 of the "Host/Term" connection in the CLV

Table 5-4: Pin assignment of the 15-pin D Sub HD "I/O" socket

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-7

Page 58

Electrical installation

Chapter 5

Operating Instructions CLV 490 Bar Code Scanner

CLV without heater on CDB 420

5.3.2

Cable no. 2 027 046 (connector cover) Cable no. 2 030 023 (connector cover with parameter memory)

Pin assignment of 15-pin D Sub HD cable plug: 6 1

11

5 10

15

Signal

15-pin plug

Connector cover 15-pin plug

15-pin socket

VS

1

–

1

RxD (RS 232), Aux

2

–

2

TxD (RS 232), Aux

3

–

3

IN 0 (Sensor 2)

4

6

–

GND

5

–

5

RD+ (RS 422/485), Host

6

–

6

RD– (RS 422/485), Host RxD (RS 232), Host

7

–

7

TD+ (RS 422/485), Host

8

–

8

TD– (RS 422/485), Host TxD (RS 232), Host

9

–

9

CAN H

10

–

10

CAN L

11

–

15

Result 1

12

4

–

Result 2

13

8

–

Sensor (Sensor 1)

14

3

–

INGND

15

9

–

Shield

Housing

Housing

Table 5-5: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 027 046/no. 2 030 023

The signals "IN 1" to "IN 4", "Result 3" to "Result 4" and "Term (RS-422/485)" are not available.

5-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 59

Electrical installation

Operating Instructions

Chapter 5

CLV 490 Bar Code Scanner

CLV without heater on CDM 490

5.3.3

Cable no. 2 020 307 (connector cover with parameter memory)

Pin assignment of 15-pin D Sub HD cable plug ("Host/Term" connection): 6 1

11

5 10

15

Signal

15-pin plug

Connector cover 15-pin socket

VS

1

1

RxD (RS 232), Aux

2

2

TxD (RS 232), Aux

3

3

Term (RS 422/485)

4

4

GND

5

5

RD+ (RS 422/485), Host

6

6

RD– (RS 422/485), Host RxD (RS 232), Host

7

7

TD+ (RS 422/485), Host

8

8

TD– (RS 422/485), Host TxD (RS 232), Host

9

9

CAN H

10

10

Reserved

11

11

CAN2 H

12

12

CAN2 L

13

13

Reserved

14

14

CAN L

15

15

Shield

Housing

Housing

Table 5-6: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 020 307

Pin assignment of 15-pin D Sub HD cable socket ("I/O" connection): 10 5

1

15

11

6

Signal

15-pin socket

Connector cover 15-pin plug

VS

1

1

IN 1

2

2

Sensor

3

3

Result 1

4

4

GND

5

5

IN 0

6

6

IN 2

7

7

Result 2

8

8

INGND

9

9

Result 3

10

10

IN 3

11

11

IN 4

12

12

I2C SDA

13

–

I2C SCL

14

–

Result 4

15

15

Shield

Housing

Housing

Table 5-7: Pin assignment: 15-pin D Sub HD socket of the cable no. 2 020 307

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-9

Page 60

Electrical installation

Chapter 5

Operating Instructions CLV 490 Bar Code Scanner

CLV with heater on CDB 420

5.3.4

Cable no. 2 033 126/2 033 127 (connector cover with parameter memory)

Pin assignment of 15-pin D Sub HD cable plug: 6 1

11

5 10

15

Signal

15-pin plug

Connector cover 15-pin plug

15-pin socket

VS

1

–

–

RxD (RS 232), Aux

2

–

2

TxD (RS 232), Aux

3

–

3

IN 0 (Sensor 2)

4

6

–

GND

5

–

5

RD+ (RS 422/485), Host

6

–

6

RD– (RS 422/485), Host RxD (RS 232), Host

7

–

7

TD+ (RS 422/485), Host

8

–

8

TD– (RS 422/485), Host TxD (RS 232), Host

9

–

9

CAN H

10

–

10

CAN L

11

–

15

Result 1

12

4

–

Result 2

13

8

–

Sensor (Sensor 1)

14

3

–

INGND

15

9

–

Shield

Housing

Housing

Table 5-8: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 033 126/no. 2 033 127

Open end (power supply): Signal

Wire

Ferrules

Connector cover 15-pin plug

15-pin socket

VS

1 red

1

1

GND

2 black

5

5

Shield

3 grey

Housing

Table 5-9: Pin assignment: open end of the cable no. 2 033 126/no. 2 033 127

The signals "IN 1" to "IN 4", "Result 3" to "Result 4" and "Term (RS-422/485)" are not available.

5-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004