Page 51
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5
Electrical installation 5.1
Installation sequence
•
Connect the CLV to a CDB 420 or CDM 490 Connection Module, or using a customerspecific wiring configuration
•
Connect the data and function interfaces of the CLV in the module
•
Connect the PC to the Connection Module (at the terminal interface on the CLV)
•
Connect the power supply to the Connection Module
5.1.1
SICK Connection Modules (overview)
CLV Type
Temperature range
CLV without heater
0 to +40 °C CDB 420-001 (+32 to +104 °F) CDB 420-101
CLV with heater
Connection module
–35 to +35 °C (–31 to +95 °F)
Purpose see chapter
– Connecting one CLV – 1 x 15-pin D Sub HD socket, 4 x cable gland (CDB 420-101: 2 x cable gland, 2 x M12 plug connection (1 x plug, 1 x socket)) – Operating voltage 18 to 30 V DC – Enclosure rating max. IP 65
5.2.3
CDM 490-0001
– Connecting one CLV – 1 x 15-pin D Sub HD plug, 1 x socket, 6 x cable gland – Operating voltage 18 to 30 V DC – Enclosure rating max. IP 65
5.2.4
CDM 490-0001
– Connecting one CLV – 1 x 15-pin D Sub HD plug, 1 x socket, 6 x cable gland – Operating voltage 24 V DC +20 %/–10 % – Enclosure rating max. IP 65 (with connector cover)
5.2.4
Table 5-1: Connection Modules for the CLV
For technical data on the modules see Chapter 10.13.2 Connection modules, Page 10-75.
5.2
Electrical connections and cables
The electrical connections on the CLV consist of two 15-pin D Sub HD connections on the housing, one plug, and one socket. These connections are used to route the following interfaces: •
Three data serial interfaces (host interface, CAN interface 1 and 2, terminal interface)
•
Six switching inputs (external reading pulse and multifunctional inputs)
•
Four switching outputs (for result status function, for connecting to a PLC for example)
•
Power supply
5.2.1
Wire cross-sections
CLV without heater: ¾
8 009 993/O824/20-12-2004
All connections must be wired with copper cables with a minimum wire diameter of 0.15 mm2 (approx. 26 AWG)!
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-1
Page 52
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
CLV with heater: ¾
Connect the power supply terminals (Pin 1/Pin 5) using copper wires with a minimum cross-section of 0.75 mm2 (approx. 20 AWG) at a maximum length of 10 m (32.8 ft)!
5.2.2
Prefabricated cables (overview)
CLV Type
Temperature range
Connection module
Optional cables
Length
Type
CLV without heater
0 to +40 °C (+32 to +104 °F)
CDB 420
1 x no. 2 027 046 or
3m (3.84 ft)
Connector cover (IP 65) to 15-pin plug
1 x no. 2 030 023
3m (3.84 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug
2 x no. 2 020 302 or
3m (3.84 ft)
Connection cable (15-pin plug/socket)
2 x no. 2 021 815 or
10 m (32.8 ft)
Connection cable (15-pin plug/socket)
1 x no. 2 020 307
3m (3.84 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket
1 x no. 2 020 303 +
3m (3.84 ft) 3m (3.84 ft)
Connection cable with 15-pin socket/open end
1 x no. 2 020 981 or
3m (3.84 ft)
Connector cover (IP 65) with parameter memory to two cables with open ends
1 x no. 2 021 267
3m (3.84 ft)
Connector cover (IP 65) to two cables with open ends
1 x no. 2 033 126 or
10 m (32.8 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug and cable with open end (power supply), suitable for track chain use
1 x no. 2 033 127
15 m (49.2 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug and cable with open end (power supply), suitable for track chain use
1 x no. 2 030 065 or
3m (3.84 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket as well as cable with open end (power supply), suitable for track chain use
1 x no. 2 031 034 or
10 m (32.8 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug and 15-pin socket as well as cable with open end (power supply), suitable for track chain use
1 x no. 2 027 543
3m (3.84 ft)
Connector cover (IP 65) with parameter memory to 15-pin plug (with wires for CAN interface 1 (IN/OUT)) and 15-pin socket
1 x no. 2 021 267
3m (3.84 ft)
Connector cover (IP 65) to two cables with open ends
CDM 490
Non-Sick Power pack
1 x no. 2 020 264 or
CLV with heater
–35 to +35 °C CDB 420 (–31 to +95 °F)
CDM 490
Non-Sick Power pack
Connection cable with 15-pin plug/open end
Table 5-2: Cables for connecting the CLV
For technical data on the cables, see Chapter 10.13.4 Cables, external parameter memories in connector cover, connector covers, Page 10-77. For function of the external parameter memory in the connector cover see Chapter 10.3 Installing and operating the external parameter memory (connector cover), Page 10-34.
5-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 53
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5.2.3
Connections/cables for the CDB 420 Connection Modules
The CDB 420 Connection Module is suitable for connecting one CLV without/with heater to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point) or to integrate the device in a SICK CAN Scanner Network. The module is available in two variants and can be operated without optional modules (see below) with an operating temperature to –35 °C (–31 °F). For technical data see Chapter 10.13.2 Connection modules, Page 10-75. Optional modules for building-in into the CDB 420: •
CMC 400 Connection Module Cloning for saving the parameters of the CLV externally
Because only one 15-pin D Sub HD socket respectively screw terminal strips for the power supply via cable glands are available for connecting the CLV to the CDB 420, the number of signals which can be connected using the terminal strips in the CDB 420 are limited. Fig. 5-1 shows the connection principle of the CDB 420. CLV 490 CDB 420 connection module AUX
Photoelectric switch Reading pulse
PC
“Aux”
HOST/PLC
Photoelectric switch Focal position Trigger One-Shot Conveyor increment End of reading interval
“Result 1 ... 2” “IN 0” CAN bus
“Result 1 ... 2” “IN 0”
PLC
18 to 30 V DC
– – Cable if required (if necessary) Fig. 5-1:
Block diagram: Connection of the CLV 490 to the CDB 420 connection module
The procedures for connecting and configuring the connection module are described in the "CDB 420 Connection Module" Operating Instructions (order no. 8 010 001, German/ English). Note
Diagrams showing you how to connect the CDB 420 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM). Connecting the CLV to the CDB 420 a) CLV without heater The following connection cables with connector cover for the CLV can be used: No. 2 027 046 (3 m (3.84 ft)) or no. 2 030 023 (3 m (3.84 ft)). The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!).
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-3
Page 54
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 033 126 (10 m (32.8 ft)) or no. 2 033 127 (15 m (49.2 ft), however not when the RS 232 host interface is used)). The cables must not be extended! If longer cables are required, the entire power supply system (Pin 1/Pin 5) must be connected with a wire cross-section of at least 0.75 mm2 (approx. 20 AWG) with a maximum length of 10 m (32.8 ft). Note
To avoid strain on the power supply lines when connecting the CLV with heater to the CDB 420, please make sure to use the correct cable wire diameters for the incoming cables of the power supply to the CDB 420 and to use corresponding fuses. Use only the screw terminals 1 to 4 for connecting the power supply. The input voltage connected to the screw terminals 1 and 2 is directly available on the screw terminals 3 and 4 for connecting the CLV 490, independent of the S1 switch (Power). Chapter 5.3 Connector pin assignment, Page 5-7 shows the pin assignments of the 15-pin plug and the open cable ends on the side of the CDB 420.
5-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 55
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5.2.4
Connections/cables for the CDM 490 Connection Module
The CDM 490 Connection Module is suitable for connecting one CLV without/with heater to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point), to integrate the device in a SICK CAN Scanner Network or in field bus systems. The module is available in one variant and can be operated without optional modules (see below) with an operating temperature to –35 °C (–31 °F). For technical data see Chapter 10.13.2 Connection modules, Page 10-75. Optional modules for building-in into the CDM 490: •
CMP 490 Power Supply Module in optional cover for supplying the CLV without heater directly from an AC power line
•
CMC 400 Connection Module Cloning for saving the parameters of the CLV externally
•
CMD 400 Connection Display Module in optional cover for representation of reading results and reading diagnosis data
•
CMF 400 Bus Modules (field bus gateways) for connecting the CLV to Profibus DP, DeviceNet or Ethernet TCP/IP
The CMP 490 Power Supply Module can not be used if the CMD 400 Display Module has always been built-in (or vice versa). For detailed description of function and installation see the corresponding Fitting/Operating Instructions (see Chapter 10.15 Supplementary documentation, Page 10-82). Fig. 5-2 shows the connection principle of the CDM 490. CLV 490 CDM 490 connection module AUX
Photoelectric switch Reading pulse
PC
“Aux”
HOST/PLC
Photoelectric switch Focal position Trigger One-Shot Conveyor increment End of reading interval
CAN bus PLC 18 to 30 V DC
– – Cable if required (if necessary) Fig. 5-2:
Block diagram: Connection of the CLV 490 to the CDM 490 connection module
The procedures for connecting and configuring the connection module are described in the "CDM 490 Connection Module" Operating Instructions (order no. 8 010 005, German/ English). Note
8 009 993/O824/20-12-2004
Diagrams showing you how to connect the CDM 490 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-5
Page 56
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM). Connecting the CLV to the CDM 490 a) CLV without heater The following connection cables without connector cover for the CLV can be used: 2 x no. 2 020 302 (3 m (3.84 ft)) or 2 x no. 2 021 815 (10 m (32.8 ft)). Pin assignment identical to device connection of the CLV. The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!). The following connection cables with connector cover for the CLV can be used: No. 2 020 307 (3 m (3.84 ft)). b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 030 065 (3 m (3.84 ft)), no. 2 031 034 (10 m (32.8 ft)) or no. 2 027 543 (3 m (3.84 ft)). The cables must not be extended! If longer cables are required, the entire power supply system (Pin 1/Pin 5) must be connected with a wire cross-section of at least 0.75 mm2 (approx. 20 AWG) with a maximum length of 10 m (32.8 ft). Note
To avoid strain on the power supply lines when connecting the CLV with heater to the CDM 490, please make sure to use the correct cable wire diameters for the incoming cables of the power supply to the CDM 490 and to use corresponding fuses. Use only the screw terminals 1 to 4 for connecting the power supply. The input voltage connected to the screw terminals 1 and 2 is directly available on the screw terminal 3 and 4 for connecting the CLV 490, independent of the S1 switch (Power). Chapter 5.3 Connector pin assignment, Page 5-7 shows the pin assignments of the 15-pin plug connections and the open cable ends on the side of the CDM 490. 5.2.5
Connections/cables for a non-SICK power pack
For connecting the CLV to a non-SICK power pack cables with open ends on the side of the power pack are available. a) CLV without heater: The following connection cables without connector cover for the CLV can be used: No. 2 020 303 (3 m (3.84 ft)) and no. 2 020 264 (3 m (3.84 ft)). Pin assignment identical to device connection of the CLV. The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!). The following connection cables with connector cover for the CLV can be used: No. 2 020 981 (3 m (3.84 ft)) or no. 2 021 267 (3 m (3.84 ft)). b) CLV with heater: The following connection cables with connector cover for the CLV can be used: No. 2 021 267 (3 m (3.84 ft)). The cable can be used with temperatures up to max. –50 °C (–58 °F) if the CLV is stationary and the cables are not moved. If the cables are moved due to changes in the position of the CLV, the temperature must not drop below max. –40 °C (–40 °F).
5-6
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 57
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
5.3
Connector pin assignment
5.3.1
Terminals on the CLV
Device plug: "Host/Term" connection 6 1
5 10
Pin 1)
11
1 2 3 4 5 6 7
15
8 9 10 11 12 13 14 15 Housing
Signal VS
Function Supply voltage
RxD (RS 232), Terminal TxD (RS 232), Terminal Term (RS 422/485) GND RD+ (RS 422/485), Host RD– (RS 422/485), Host RxD (RS 232), Host TD+ (RS 422/485), Host TD– (RS 422/485), Host TxD (RS 232), Host CAN H Reserved CAN2 H CAN2 L Reserved CAN L –
Terminal interface (receiver) Terminal interface (transmitter) Termination host interface Ground Host interface (receiver+) Host interface (receiver–) Host interface (transmitter+) Host interface (transmitter–) CAN interface 1 (IN/OUT) – CAN interface 2 (IN/OUT) CAN interface 2 (IN/OUT) – CAN interface 1 (IN/OUT) Shield
1) Pin 1 is jumpered with Pin 1 of the "I/O" connection in the CLV
Table 5-3: Pin assignment of the 15-pin D Sub HD "Host/Term" plug
Device socket: "I/O" connection L
10 5
1
6
Pin
Signal
Function
VS
Supply voltage
2
IN 1
Switching input (trigger for focus control)
3
Sensor
Switching input (external reading pulse)
4
Result 1
Switching output, variable function
5
GND
Ground
6
IN 0
Switching input (trigger for focus control)
1 15
11
1)
7
IN 2
Switching input (trigger for focus control)
8
Result 2
Switching output, variable function
9
INGND
Common ground for all inputs
10
Result 3
Switching output, variable function
11
IN 3
Switching input, variable function
12
IN 4
Switching input, variable function
13
I2C SDA
I2C Bus (for external parameter memory)
14
I2C SCL
I2C Bus (for external parameter memory)
15
Result 4
Switching output, variable function
Housing
–
Shield
1) Pin 1 is jumpered with Pin 1 of the "Host/Term" connection in the CLV
Table 5-4: Pin assignment of the 15-pin D Sub HD "I/O" socket
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-7
Page 58
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
CLV without heater on CDB 420
5.3.2
Cable no. 2 027 046 (connector cover) Cable no. 2 030 023 (connector cover with parameter memory)
Pin assignment of 15-pin D Sub HD cable plug: 6 1
11
5 10
15
Signal
15-pin plug
Connector cover 15-pin plug
15-pin socket
VS
1
–
1
RxD (RS 232), Aux
2
–
2
TxD (RS 232), Aux
3
–
3
IN 0 (Sensor 2)
4
6
–
GND
5
–
5
RD+ (RS 422/485), Host
6
–
6
RD– (RS 422/485), Host RxD (RS 232), Host
7
–
7
TD+ (RS 422/485), Host
8
–
8
TD– (RS 422/485), Host TxD (RS 232), Host
9
–
9
CAN H
10
–
10
CAN L
11
–
15
Result 1
12
4
–
Result 2
13
8
–
Sensor (Sensor 1)
14
3
–
INGND
15
9
–
Shield
Housing
Housing
Table 5-5: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 027 046/no. 2 030 023
The signals "IN 1" to "IN 4", "Result 3" to "Result 4" and "Term (RS-422/485)" are not available.
5-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 59
Electrical installation
Operating Instructions
Chapter 5
CLV 490 Bar Code Scanner
CLV without heater on CDM 490
5.3.3
Cable no. 2 020 307 (connector cover with parameter memory)
Pin assignment of 15-pin D Sub HD cable plug ("Host/Term" connection): 6 1
11
5 10
15
Signal
15-pin plug
Connector cover 15-pin socket
VS
1
1
RxD (RS 232), Aux
2
2
TxD (RS 232), Aux
3
3
Term (RS 422/485)
4
4
GND
5
5
RD+ (RS 422/485), Host
6
6
RD– (RS 422/485), Host RxD (RS 232), Host
7
7
TD+ (RS 422/485), Host
8
8
TD– (RS 422/485), Host TxD (RS 232), Host
9
9
CAN H
10
10
Reserved
11
11
CAN2 H
12
12
CAN2 L
13
13
Reserved
14
14
CAN L
15
15
Shield
Housing
Housing
Table 5-6: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 020 307
Pin assignment of 15-pin D Sub HD cable socket ("I/O" connection): 10 5
1
15
11
6
Signal
15-pin socket
Connector cover 15-pin plug
VS
1
1
IN 1
2
2
Sensor
3
3
Result 1
4
4
GND
5
5
IN 0
6
6
IN 2
7
7
Result 2
8
8
INGND
9
9
Result 3
10
10
IN 3
11
11
IN 4
12
12
I2C SDA
13
–
I2C SCL
14
–
Result 4
15
15
Shield
Housing
Housing
Table 5-7: Pin assignment: 15-pin D Sub HD socket of the cable no. 2 020 307
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-9
Page 60
Electrical installation
Chapter 5
Operating Instructions CLV 490 Bar Code Scanner
CLV with heater on CDB 420
5.3.4
Cable no. 2 033 126/2 033 127 (connector cover with parameter memory)
Pin assignment of 15-pin D Sub HD cable plug: 6 1
11
5 10
15
Signal
15-pin plug
Connector cover 15-pin plug
15-pin socket
VS
1
–
–
RxD (RS 232), Aux
2
–
2
TxD (RS 232), Aux
3
–
3
IN 0 (Sensor 2)
4
6
–
GND
5
–
5
RD+ (RS 422/485), Host
6
–
6
RD– (RS 422/485), Host RxD (RS 232), Host
7
–
7
TD+ (RS 422/485), Host
8
–
8
TD– (RS 422/485), Host TxD (RS 232), Host
9
–
9
CAN H
10
–
10
CAN L
11
–
15
Result 1
12
4
–
Result 2
13
8
–
Sensor (Sensor 1)
14
3
–
INGND
15
9
–
Shield
Housing
Housing
Table 5-8: Pin assignment: 15-pin D Sub HD plug of the cable no. 2 033 126/no. 2 033 127
Open end (power supply): Signal
Wire
Ferrules
Connector cover 15-pin plug
15-pin socket
VS
1 red
1
1
GND
2 black
5
5
Shield
3 grey
Housing
Table 5-9: Pin assignment: open end of the cable no. 2 033 126/no. 2 033 127
The signals "IN 1" to "IN 4", "Result 3" to "Result 4" and "Term (RS-422/485)" are not available.
5-10
© SICK AG · Division Auto Ident · Germany · All rights reserved