Page 37

Installation

Operating Instructions

Chapter 4

CLV 490 Bar Code Scanner

4

Installation 4.1

Note

Installation sequence

•

Change the language version of the laser warning label (if necessary)

•

Select the mounting location for the CLV

•

Mount the CLV and align the CLV with the bar code

•

Mount the CDB 420 or CDM 490 Connection Module

•

Connect the CLV to the CDB 420 or CDM 490 Connection Module

•

Adjust the CLV so that it is in line with the bar code

•

Mount the reading pulse sensor for external triggering the reading pulse

•

Option with event-controlled dynamic focus control: mount the sensors for detecting the object distance

Don’t open the device. The producer warranty will be forfeited if the device is opened.

4.2

Preparations

4.2.1

Required components

•

CLV Bar Code Scanner

4.2.2 •

Required accessories

SICK mounting bracket for the CLV: depending on the order, angle bracket no. 2 013 824, articulated bracket no. 2 018 435, or quick-clamping device no. 2 016 110 with securing material for the CLV – or – Alternatively, if the bracket is supplied by the user – Stable mounting device that allows the alignment of the CLV to be varied in the x and y axes. The weight of the CLV (line scanner) is 1.5 kg (3.3 lb) and 2.2 kg (4.84 lb) as a line scanner with oscillating mirror. – 2 screws M6 for the CLV. The screw length depends on the wall thickness of the bracket used. Depth of engagement in CLV max. 7 mm (0.28 in) from housing surface.

•

CDB 420 or CDM 490 Connection Module (not included in the scope of supply of the CLV)

•

Reading pulse sensor for external reading pulse triggering, e. g. photoelectric reflex switch/ photoelectric proximity switch (not included in the scope of supply of the CLV)

•

Option with event-controlled dynamic focus control: sensors for detecting the object distance, e. g. photoelectric reflex switches/photoelectric proximity switches (not included in the scope of supply of the CLV)

•

Optionally for internal tracking: an incremental encoder (not included in the scope of supply of the CLV)

4.2.3

8 009 993/O824/20-12-2004

Required auxiliary parts

•

2 screws M6 for securing the SICK mounting bracket to the base. The screw length depends on the wall thickness of the base.

•

Set of laser warning labels (if necessary)

•

Tool

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-1

Page 38

Chapter 4

Installation

Operating Instructions CLV 490 Bar Code Scanner

•

Measuring tape (up to 3 m (118.2 in))

•

Protractor

4.2.4

Replacing the laser warning label

If necessary, replace the GB/US laser warning label with the required language (Fig. 4-1). The device is delivered with a set of laser warnings in: •

German/US laser warning and

•

French/US laser warning

See also Chapter 2.3 General safety instructions and protection measures, Page 2-2. Supplied laser warnings:

Fig. 4-1:

4.2.5

Line scanner: replacing the laser warning labels

Selecting the mounting location

When you select the mounting location, the distance between the CLV and the host and between the CLV and the bar code are extremely important. Distance between the CLV and the host The CLV can be mounted at a maximum distance of 1,200 m (3, 937 ft) from the host without a connection to the SICK network or a bus. In practice, however, the distance depends on the physical configuration of the host interface and the data transfer rate (see Table 5-21, Page 5-17). Distance between the CLV and the CDB 420 or CDM 490 Connection Module The CDB 420 or CDM 490 Connection Module should not be located further than 10 m (32.8 ft) from the CLV, since the "CLV-Setup" program on the PC accesses the terminal interface (RS 232) of the CLV via this module.

4-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 39

Operating Instructions

Installation

Chapter 4

CLV 490 Bar Code Scanner

4.2.6

Mounting accessories

The CLV is secured in position using the two tapped blind holes (M6) above the electrial connections. Fig. 4-2 shows the location of the threads near the line scanner. The dimensions of the CLV housing are shown in Fig. 9-1, Page 9-3 to Fig. 9-2. Blind hole thread, M6, 7 mm (0.28 in) deep

Drilled hole, ∅ 3.6 mm, 6 mm (0.24 in) deep

Fig. 4-2:

Line scanner: position of the securing threads on the CLV

The CLV can be mounted using the SICK bracket: •

Mounting bracket, single no. 2 013 824

•

Articulated bracket (2 x mounting bracket, single) no. 2 018 435

•

Quick-clamping device no. 2 016 110

The brackets are designed to support a variety of mounting positions and alignments in two planes. Fig. 4-3 shows two mounting examples. The elongated holes in the mounting bracket no. 2 013 824 and in the articulated bracket no. 2 018 435 allow the CLV to be adjusted with a freedom of rotation of ±15°.

Quick-clamping device

Mounting bracket

Fig. 4-3:

Line scanner: Mounting possibilities of the CLV

The dimensions of the mounting brackets are shown in Chapter 10.14 Dimensioned drawings of the accessories, Page 10-81

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-3

Page 40

Chapter 4

Installation

Operating Instructions CLV 490 Bar Code Scanner

4.2.7

Distance between the CLV and the bar code

Basic alignment between the CLV and the bar code Depending on the application, the line scanner or line scanner with oscillating mirror versions of the CLV is used. Fig. 4-4 shows how the device is aligned with the bar code on the object for each of the two scanning methods. Line scanner

Fig. 4-4:

Line scanner with oscillating mirror

Scanning methods: alignment with bar code and conveyor direction

Reading distance from the bar code and aperture angle α The distance between the reading window of the CLV and the bar code must not exceed the technical limits. The height of the reading field is shown as a function of the reading distance for various resolutions (module widths) depending on the CLV type in Chapter 10.2 Specification diagrams, Page 10-1. Fig. 4-5 shows the definition of the reading distance "a" (radial measured) from the reading window and of the aperture angle α each of the two scanning methods. Line scanner

Line scanner with oscillating mirror

α

α

Reading distance a Reading distance a

105°

Fig. 4-5:

Definition of the reading distance "a" and of the aperture angle α

The useful aperture angle is typically 56° for the line scanner and max. 50° for the line scanner with oscillating mirror. Due to the V-principle of beam deflection, the reading field height (for evaluating the useful length of the scan line) depends on the readling distance.

4-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 41

Installation

Operating Instructions

Chapter 4

CLV 490 Bar Code Scanner

Angular alignment of the CLV The alignment of the CLV is optimum when the scan line travels over the bar code lines almost at a right angle (90°) (Fig. 4-4). All possible reading angles that can occur between the scan line and the bar code must be taken into consideration (Fig. 4-6 and Table 4-1). α: Azimuth angle (tilt) β: Angle of inclination (pitch) γ: Angle of rotation (skew)

Reading range

CLV

Fig. 4-6:

Reading distance

Line scanner: Reading angle between the scan line and the bar code

Angle

Limit value

Tilt α (azimuth)

max. 45°

Pitch β max. 45°

Skew γ max. 45°

Table 4-1: Permissible reading angles between the scan line and bar code

Note

If reading from the front, mount the CLV above the conveyor belt in such a way against the conveying direction that the scan line hits the object under a skew of approx. 10°. Avoiding surface reflection If the light from the scan line strikes the surface of the bar code vertically, interference may be caused by reflections when the returned light is received. To avoid surface reflection, the CLV must be mounted in such a way that the emitted light is tilted slightly with respect to the vertical axis (Fig. 4-7). Line scanner

Line scanner with oscillating mirror 15°

15°

105°

(Top view) Fig. 4-7:

(Side view)

Avoiding surface reflections: Angle between the emitted light and the bar code (tilted away from the vertical axis)

In the case of the line scanner with oscillating mirror, the laser beam is emitted at an angle of 105° with respect to the housing as it passes through the neutral position (CW = 50) while oscillating. The device can only be flush-mounted with the conveyor belt with limited deflection ranges. Otherwise, the device must also be mounted at an angle of 15° to ensure that the deflection ranges are symmetric.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-5

Page 42

Installation

Chapter 4

Operating Instructions CLV 490 Bar Code Scanner

Note

In oscillating mode with variable amplitude, the scan line must always sweep the neutral position (CW = 50). This means that oscillation is not possible in the range 60 CW to 80 CW, for example, but is possible in the range 40 CW to 80 CW. 4.2.8

Explanation

Count direction of the code position CP and code angle CW

The CLV can scan and decode several bar codes with each read. In doing so, it determines the specific local reading diagnosis data for each bar code: •

The position (CP value) of the center of the bar code within the scan line

•

(Scanning method using the oscillating mirror) also the angle of deflection of the scan line (CW value) at which the center of the bar code is recorded

Fig. 4-8 shows the count direction of the code position and code angle. In the case of the line scanner, the count direction of the code position is marked by a small triangle above the reading window. By determining this data, the device can separate identical bar codes (code type, code length, and data content identical) and assign the bar code data in the reading result to its position on the object. Line scanner with oscillating mirror

Line scanner

90 100 CW CP

10

0

0 CP 100

Scanning direction

Aperture angle α (opening angle) in the scanning direction: 1° = 1.5 CP (56° = 90 CP) Deflection angle of the scan line crosswise to the scanning direction: 1° = 2 CW (20° = 40 CW) Fig. 4-8:

Tip

4-6

Count direction of the code position CP in the scan line and of the code angle CW for the oscillating mirror

In the default setting, the CLV does not output the "CP" and "CW" values (line scanner with oscillating mirror only) in the reading result on the host interface. If this is required to evaluate the result in the host, the values can be included in the "Code-Info/Separator" block of the output string using the "CLV-Setup" program.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 43

Operating Instructions

Installation

Chapter 4

CLV 490 Bar Code Scanner

Configuring the Code-Info/Separator: 1.

Choose the DATA STRINGS tab.

2.

Click the CODE-INFO/SEPARATOR field. The EDIT PARAMETER TFS dialog box is displayed.

3.

In the list field, click the CP and/or CW parameters. CP and/or CW then appears in the top line.

4.

Confirm your selections with OK.

5.

Download the data to the CLV by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.

6.

Confirm the dialog box by choosing PERMANENT. The CLV outputs the CP value and the CW value on the host interface for each bar code in the reading result. The values are displayed as a 3-digit number in the associated "Code-Info/Separator" block.

4.3

Mounting and adjusting the device

4.3.1

Mounting the CLV

1.

Prepare the base for mounting the bracket as described in Chapter 4.2.2 Required accessories, Page 4-1.

2.

Place the object containing the bar code within the reading field of the CLV (in the position at which it is to be read) with the conveyor belt switched off.

3.

Align the CLV with the bar code (in accordance with the scanning method) in such a way that – with the line scanner the back of the device with the LEDs is almost parallel with the bar code surface, – with the line scanner with oscillating mirror, the broad side wall (back of the oscillating mirror) is almost parallel with the bar code surface All of the possible reading angles must be taken into consideration (see Fig. 4-6, Page 4-5).

4.

If it is relevant for the evaluation, note the count direction of the code position and code angle (see Fig. 4-8, Page 4-6).

5.

Mount the CLV bracket on the base.

Risk of damage to the device The maximum depth of engagement of the two blind hole threads M6 is 7 mm (0.28 in). Longer screws will damage the device.

8 009 993/O824/20-12-2004

¾

Use screws with the correct length.

6.

Screw the screws M6 through the bracket into the blind hole threads of the CLV.

7.

Tighten the screws slightly.

8.

Adjust the CLV as described below.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-7

Page 44

Installation

Chapter 4

Operating Instructions CLV 490 Bar Code Scanner

4.3.2

Adjusting the CLV

The CLV can be adjusted in Percentage Evaluation mode. In this mode, the CLV displays the quality of the bar code reads that enter the CLV reading field statically (the object is not moved on the conveyor belt). The CLV performs 100 scans and evaluates the reading quality statistically. It then outputs the reading results every 2 s on the terminal interface. Note

In default setting, the CLV operates in the autofocus mode "Minimum distance“. As a result, the CLV focuses on the object that is nearest in Percentage Evaluation mode. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must be selected. Alternatively a fixed focus position can be set. See Chapter c) Parameterizing focus control, Page 6-12. The behavior of the "Read Result" LED also indicates the reading quality: –

The LED is extinguished if reading quality is < 30 %

–

The LED flashes twice per second if the reading quality is 30 % to 70 %

–

The LED flashes five times per second if the reading quality is 70 % to 90 %

–

The LED is lit continuously if the reading quality is > 90 %

The scanning frequency in the default setting is 800 Hz. 1.

Connect the CLV to the CDB 420 or CDM 490 Connection Module and switch on the power supply (see Chapter 5.5.3 Connecting the supply voltage, Page 5-19). After it has started, the CLV confirms that the self-test was successfuly and switches to reading mode ("Device Ready" LED lights up).

2.

Connect the PC to the terminal interface of CLV. To do so, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Aux" plug of the CDB 420 or CDM 490 (see Chapter 5.5.6 Connecting the PC, Page 5-22).

3.

Start Windows and the "CLV-Setup" program (see Chapter 10.6.3 Starting CLV-Setup, Page 10-46).

Choosing the standard decoder: 4.

Choose the CODE CONFIGURATION tab.

5.

Click the STANDARD option in the DECODER section.

6.

Download the settings to the CLV. To do so, click the STANDARD option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily. The CLV then operates with the standard decoder (until the CLV is switched off).

Activating Percentage Evaluation mode: 7.

From the VIEW menu, choose PERCENTAGE EVALUATION. The dialog box for entering the distance configuration appears.

8.

Click the relevant distance configuration for the reading distance: – with autofocus mode the distance configuration no. 1 – with event-controlled dynamic focus control the distance configuration that matches the reading distance of the object (default: no. 1, focus position F = 1,200 mm (47.3 in)).

9.

4-8

Confirm the dialog box with OK. The Terminal Emulator is launched and displays the reading result continuously (see Chapter 6.5.2 Percentage evaluation, Page 6-42).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 45

Operating Instructions

Installation

Chapter 4

CLV 490 Bar Code Scanner

Monitor the reading quality (%) during each of the subsequent steps! Line scanner with oscillating mirror: In the "Percent Evaluation" mode, the CLV behaves in the following manner: – in "Oscillating" mode (default setting: oscillating with a fixed amplitude), the CLV shuts off oscillation and positions the scan line under the angle CW = 50 (corresponds to an angle of deflection of 105°). This position cannot be altered. – in "One-Shot" mode, the CLV also positions the scan line under the angle CW = 50 – in "Set Position" mode, the scan line’s selected position remains unchanged. Performing fine adjustment: 10. Align the CLV in such a way that the angle between the scan line and the bars on the bar code CLV is almost 90°. The oscillating mirror must be aligned in such a way that the scan line is located at the center of the bar code, perpendicular to the bar code lines, when it is in the neutral position (CW = 50). 11. To avoid interfering reflections, tilt the line scanner away from the vertical axis so that the light strikes the bar code at an angle of approx. 105° (see Fig. 4-7, Page 4-5). 12. If necessary, position the scan line exactly at the direct center of the bar code. See Chapter 4.3.3 Adjusting mode below. 13. Move objects carrying bar codes into the CLV reading field manually under realistic conditions and check the reading result. If the objects are aligned randomly, or if the bar code is located at different positions (angles), ensure that the limit values of the permissible reading angles are not exceeded. 14. Adjust the CLV in such a way that the good read rate is between 70 ... 100 %. With event-controlled dynamic focus control, for each defined reading range (distance configuration), check the selected focus position and correct the parameter settings if necessary (see Chapter 6.4.4 Guide to parameterization menu, Page 6-9). 15. Tighten the screws on the CLV. The CLV is aligned with the bar code. 4.3.3

Adjusting mode

The "Adjusting mode" helps you to position the center of the scan line on the object. To do so, the CLV masks out one half of the scan line from the center (code position CP = 50 to CP = 100). This is irrespective of whether the CLV is operated in Autofocus mode or with distance configurations for event-driven dynamic focus control. Fig. 4-9 shows the resulting position of the scan line (line scanner). Adjusting mode

Scan line CP = 100

Range masked out CP = 50

CP = 0

Fig. 4-9:

8 009 993/O824/20-12-2004

Line scanner: scan line in Adjusting mode

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-9

Page 46

Chapter 4

Installation

Operating Instructions CLV 490 Bar Code Scanner

Line scanner with oscillating mirror: In "Adjusting" mode, the oscillating mirror behaves in the same manner as within the ”Percent Evaluation” mode (see Page 4-8, “Activating Percentage Evaluation mode:“). 1.

Activate the operating mode as described in Chapter 6.5.3 Adjusting mode, Page 6-44.

2.

Position the CLV in such a way that the center of the scan line, indicated by the end of the scan line (code position CP = 50), is located at the center of the bar code, or at the center of the field for all codes if several bar codes are used.

Show CP Limits The "Show CP Limits" operating mode allows you to test whether the desired effect was produced by narrowing the scan line’s active evaluation range. The CLV alternatively hides certain parts of the scan line in accordance with the selected min. and max. values of the code position. For activation of this operating mode and for checking, See Chapter 6.5.5 Show CP-limits, Page 6-47.

4-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 47

Installation

Operating Instructions

Chapter 4

CLV 490 Bar Code Scanner

4.4

Mounting the external components

4.4.1

Mounting the CDB 420 or CDM 490 Connection Module

1.

Mount the CDB 420 or CDM 490 Connection Module near the CLV. The distance between the connection module and CLV should not exceed max. 10 m (32.8 ft).

2.

Mount the CDB 420 or CDM 490 in such a way that accessed to the open device is always possible. The terminal interface of the CLV is accessed via the 9-pin, internal "Aux" plug.

Detailed information on the mounting and electrical installation procedures is provided in the "CDB 420 Connection Module" Operating Instructions (order no. 8 010 001, German/English) respectively in the "CDM 490 Connection Module" Operating Instructions (order no. 8 010 005, German/English). 4.4.2

Mounting the external reading pulse sensor

If the CLV is triggered by an external reading pulse sensor, the sensor must be mounted in the vicinity of the CLV. The "Sensor" switching input is selected as the default trigger source for this trigger type. The default debounce time of the input is 30 ms. Fig. 4-10 shows two examples of where a photoelectric reflex switch can be mounted. This depends on the distance a from the bar code to the front of the object. Depending on the application, you may need to mount the sensor in such a way that bar codes on objects of different sizes can be read completely during the reading interval ("internal reading gate").

Bar code in the center or at the end of the object a

(Top view)

a b<a b b<a b

Bar code at the start of the object a

(Top view)

a b<a b Fig. 4-10:

b<a b

Line scanner: mounting example for the external reading pulse sensor

Note

8 009 993/O824/20-12-2004

In default setting, the CLV operates in the autofocus mode "Minimum distance“. As a result, the CLV focuses on the object that is nearest in Percentage Evaluation mode. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-11

Page 48

Chapter 4

Installation

Operating Instructions CLV 490 Bar Code Scanner be selected. Alternatively a fixed focus position can be set. See Chapter c) Parameterizing focus control, Page 6-12. Installing the reading pulse sensor for start/stop mode: 1.

Mount the reading pulse sensor.

2.

Connect the reading pulse sensor to the "Sensor (1)" switching input of the CLV via the CDB 420 or CDM 490 Connection Module (see Chapter 5.5.7 Connecting the "Sensor" switching input, Page 5-23).

3.

Connect the CLV to the CDB 420 or CDM 490 Connection Module and switch on the power supply to the module (see Chapter 5.5.3 Connecting the supply voltage, Page 5-19). After it has started, the CLV confirms that the self-test was successfull and switches to Reading mode ("Device Ready" LED lights up).

4.

Connect the PC to the terminal interface of CLV. To do so, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Aux" plug of the CDB 420 or CDM 490 (see Chapter 5.5.5 Connecting the CAN interface, Page 5-22).

5.

Start Windows and the "CLV-Setup" program (see Chapter 10.6.3 Starting CLV-Setup, Page 10-46).

6.

From the VIEW menu, choose READING MODE. The Terminal Emulator is launched. The CLV is in Reading mode (default: SMART decoder). Monitor the reading result during each of the subsequent steps! Line scanner with oscillating mirror: In default setting, the CLV deflects the scan line (default setting) about the fixed position CW = 50 with a frequency of 1 Hz at a max. angle of ±20° (±40 CW). 50 CW corresponds to an angle of emergence of 105°.

7.

Move objects with bar codes into the CLV reading field manually under realistic conditions and check whether the reading result and trigger pulse are correct.

8.

Repeat the procedure with the conveyor switched on. Check whether the reading procedure is synchronized with the objects.

Parameterizing an external sensor as a trigger source: These settings are not required if the CLV is operated with the default configuration. 1.

Choose the DEVICE CONFIGURATION tab.

2.

In the READING TRIGGER SOURCE section click the option SENSOR INPUT (ACTIVE HIGH).

3.

Download the settings to the CLV by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.

4.

Confirm the dialog box by choosing PERMANENT. The CLV operates with the "Sensor" switching input as an external trigger source. The reading pulse starts when the input is energized (high).

4.4.3

Installing incremental encoder

In the reading mode "Tracking", an incremental encoder is required for determining which bar codes belong to which objects. The encoder is also required to separate bar codes of the same symbology with identical content. 1.

4-12

Install the incremental encoder (e. g. no. 2 022 714) near the CLV but in front of it, preferably against the direction of the conveyor belt. The increment pulses must originate from the area of the conveyor belt which the CLV is reading.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 49

Operating Instructions

Installation

Chapter 4

CLV 490 Bar Code Scanner

2.

Ensure that the incremental encoder is contacting the conveyor and that the friction wheel turns without slipping.

3.

Connect incremental encoder to the "IN4" switching input of the CLV (not available via the terminals of the CDB 420 Connection Module). See Chapter 5.5.8 Connecting the "IN 0" to "IN 4" switching inputs, Page 5-24.

4.4.4

Mounting the sensors for detecting the object distance

If the dynamic focus control function of the CLV is triggered by external sensors, suitable sensors must be mounted in the vicinity of the CLV. Fig. 4-11 shows an example of a read operation from above. The sensors must be arranged in such a way that all of the potential object heights are classified uniquely and overlapping reading ranges occur that can be formed with the depths of field of the CLV. A maximum of five switching inputs are available for this purpose. A max. of 32 switching states for 8 distance configurations (reading ranges) can be implemented using the internal assignment table (combinations). Photoelectric reflex switches, for example, can be used to detect the object distance. In the default setting, all five "IN 0" ... "IN 4" switching inputs are selected for dynamic focus control.

Object distance DC8 LS7

Reading distance

DC2 LS2 DC1 LS1 h7 h2 h1

DC = Distance Configuration Fig. 4-11:

8 009 993/O824/20-12-2004

Mounting example for object distance detection

1.

The depths of field of the CLV for the bar code resolution in question is shown in the graphs in Chapter 10.2 Specification diagrams, Page 10-1 onwards. Find and note suitable focus positions for overlapping reading ranges.

2.

Mount distance sensors (e. g. photoelectric reflex switches) one above the other in a row at the mounting location to measure the object distance (see also assignment Table 5-28, Page 5-25). It is advisable to mount these distance sensors opposite the direction of motion of the conveyor belt at approx. 100 mm (3.94 in) in front of the reading pulse sensor.

3.

Connect the distance sensors to the "IN 0" ... "IN 4" switching inputs on the CLV via the CDB 420 or CDM 490 Connection Module (see Chapter 5.5.7 Connecting the "Sensor" switching input, Page 5-23). Via the terminals of the CDB 420 Connection Module only the IN 0 input can be connected.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-13

Page 50

Installation

Chapter 4

Operating Instructions CLV 490 Bar Code Scanner

4.

Set the focus positions for the required reading ranges on the READING CONFIGURATION tab in the "CLV-Setup" program. To do so, choose the INPUTS/SERIAL option in the drop down list of the FOCUS CONTROL section.

5.

Click the DISTANCE CONFIGURATION button and edit the required entries in the dialog box that is then displayed (default: Focus position F 1 up to F 8 = 1,200 mm (47.3 in)).

6.

As described in Chapter 4.3.2 Adjusting the CLV, Page 4-8, choose the standard decoder.

7.

Perform a temporarily download to the CLV.

8.

Start Percentage Evaluation mode.

9.

Check the reading quality in all distance configurations while the conveyor belt stationary.

10. Then check the distance detection function in Reading mode under realistic conditions. To do so, monitor the reading result in the Terminal Emulator as described in Chapter 4.4.2 Mounting the external reading pulse sensor, Page 4-11. 11. If the distance detection function operates correctly, reset the decoder to the SMART/ STANDARD option and perform a permanently download to the CLV. Note

The CLV can switch between a maximum of 8 distance ranges for slow search runs using the integrated timer or the oscillating mirror reversal points. The CLV can be switched between a maximum of 8 distance ranges synchronously to the reading process using command strings.

4.5

Dismantling the device

1.

Switch off the power supply to the CDB 420 or CDM 490 Connection Module.

2.

Undo the screws for the cable connections on the CLV and disconnect the cables. With mounted external parameter memory (optional): Undo both screws and remove the cover.

3.

Unscrew the CLV from the mounting device.

When removing the device from service for the last time, please dispose of it in an environmentally-friendly manner, as described in Chapter 7.3 Disposal, Page 7-2.

4-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004