Page 23

Product description

Operating Instructions

Chapter 3

CLV 490 Bar Code Scanner

3

Product description 3.1

Design

3.1.1

Scope of delivery

The CLV is supplied with the following in the packing: •

An information sheet (note on device) with terminal diagram and Quick Start instructions

•

An additional set of Class 2 laser warning labels (self-adhesive) in German/US English and French/US English

Depending on the number of devices ordered, one or more copies of the following: •

CD-ROM (no. 2 029 112) with – "CLV-Setup" program for Windows TM and the "CLV-Setup Help" online help system (HTML files) – "CLV Connect" PC software (HTML files showing terminal diagrams) – CLV 490 Operating Instructions in English and German as PDF edition as well as additional publications (connections module, other SICK bar code scanners) – freely available "Acrobat Reader" PC software for reading PDF files

Note

The latest versions of all the current publications/programs on the CD-ROM can also be downloaded from www.sick.com. Depending on the number of copies ordered, the delivery includes (optional): •

CLV 490 Operating Instructions in English and/or German (printed edition)

Chapter 10.13 Accessories, Page 10-75 contains an overview of the available mounting accessories, (bus) connection modules, external parameter memories, cables, connectors, and incremental encoder as well as sensors for generating the reading pulse. 3.1.2

Variants

Low density

Standard

High density

The CLV is currently available in the following variants: Type (red light)

Part. no.

Scanning method

Resolution

Reading window

Heater

CLV 490-2010

1 019 311

Line scanner

From 0.2 mm (7.9 mil)

End

No

CLV 490-3010

1 019 313

Line scanner with oscillating mirror

From 0.2 mm (7.9 mil)

Side

No

CLV 490-2011

1 019 312

Line scanner

From 0.2 mm (7.9 mil)

End

Yes

CLV 490-3011

1 019 314

Line scanner with oscillating mirror

From 0.2 mm (7.9 mil)

Side

Yes

CLV 490-0010

1 016 958

Line scanner

From 0.3 mm (11.8 mil)

End

No

CLV 490-1010

1 016 959

Line scanner with oscillating mirror

From 0.3 mm (11.8 mil)

Side

Yo

CLV 490-0011

1 016 960

Line scanner

From 0,3 mm (11.8 mil)

End

Yes

CLV 490-1011

1 016 961

Line scanner with oscillating mirror

From 0.3 mm (11.8 mil)

Side

Yes

CLV 490-6010

1 018 872

Line scanner

From 0.4 mm (15.7 mil)

End

No

CLV 490-7010

1 019 094

Line scanner with oscillating mirror

From 0.4 mm (15.7 mil)

Side

No

CLV 490-6011

1 019 095

Line scanner

From 0.4 mm (15.7 mil)

End

Yes

CLV 490-7011

1 019 096

Line scanner with oscillating mirror

From 0.4 mm (15.7 mil)

Side

Yes

Table 3-1: CLV variants

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-1

Page 24

Chapter 3

Product description

Operating Instructions CLV 490 Bar Code Scanner

3.1.3 CLV without heater

System requirements for stand-alone configuration

The following are required to start up and operate the CLV 490 without heater: 1.

A SICK Connection Module to provide the power supply of the CLV (18 to 30 V DC) and connect the data and function interfaces. Available types: – CDB 420-001 (no. 1 023 885) for 10 to 30 V DC, enclosure rating max. IP 65 – CDB 420-101 (no. 1 024 305) for 10 to 30 V DC, enclosure rating max. IP 65 – CDM 490-0001 (no. 1 025 363) for 10 to 30 V DC, enclosure rating max. IP 65 – or – Alternatively, a non-SICK Power pack with a voltage output of 18 to 30 V DC (functional extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of 20 W. Cable no. 2 020 264 (3 m (9.84 ft)) with 15-pin D Sub HD connector and one open end for connecting the CLV to the non-SICK Power pack (supply voltage).

2.

The following operating voltages/power output values: – CDB 420-001: 18 to 30 V DC (to IEC 364-4-41), min. 20 W – CDM 490-0001: 18 to 30 V DC (to IEC 364-4-41), min. 40 W, when using the CMP 490 Power Supply Module: 100 to 250 V AC, 50 to 60 Hz – If the following modules are additionally built-in in the CDB 420: CMC 400 (Conenction Module Cloning): 18 to 30 V DC, additionally 0.5 W – If the following modules are additionally built-in in the CDM 490: CMC 400 (Connection Module Cloning): 18 to 30 V DC, additionally 0.5 W CMD 400 (Connection Module Display): 18 to 30 V DC, additionally 1 W CMF 400 (Connection Module Fieldbus): 18 to 30 V DC, additionally 2 W

3.

Fitting cables see Chapter 5.2.2 Prefabricated cables (overview), Page 5-2.

4.

With external clock pulse (start/stop) supply via the "Sensor" switching input: a suitable reading pulse sensor for signaling an object with a bar code, e. g. a photoelectric reflex switch.

5.

With extended external clock pulse (stop) via the "IN 4" switching input: a suitable reading pulse sensor for signaling the end of an object, e. g. a photoelectric reflex switch.

6.

With object distance detection via the "IN 0" to "IN 4" switching inputs: suitable sensors for multi-stage dynamic focus control, e. g. photoelectric reflex switches.

7.

With internal object tracking (to assign bar codes to objects if there are only small distances between the objects in conveying direction): a suitable incremental encoder, e. g. no. 2 022 714.

8.

To separate bar codes with the same name (same code type, identical data content) using the "Compare Code Position" function: a suitable incremental encoder (s. above).

9.

A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.

10. A PC (min. 80486, 66 MHz, 16 MB RAM, CD drive, a serial port (COM x), mouse (recommended)) with Windows 95TM/98TM, Windows NTTM, Windows 2000TM or Windows XPTM. 11. A 3-core RS 232 data cable (null modem cable) with two 9-pin D Sub sockets for connecting the PC to the terminal interface of the CLV in the connection module, e. g. no. 2 014 054. Pin 2 (RxD) and Pin 3 (TxD) are crossed. 12. An HTML browser, e. g. Internet ExplorerTM, for using the online help system CLV-Setup Help. 13. To connect the CLV to Profibus DP, to Device Net or to Ethernet TCP/IP: the appropriate CMF 400 Connection Module Fieldbus for building-in in the CDM 490 Connection Module.

3-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 25

Product description

Operating Instructions

Chapter 3

CLV 490 Bar Code Scanner

14. For connection of the CLV to the CAN Scanner Network: the Operating Instructions “Application of the CAN interface“ (no. 8 009 180, English edition). CLV with heater

The following are required to start up and operate the CLV 490 with heater: 1.

A SICK Connection Module to provide the power supply for the CLV (24 V DC +20 %/ –10 %) and connect the data and function interfaces. Available types: – CDM 490-0001 (no. 1 025 363) for 10 to 30 V DC, enclosure rating max. IP 65 – or – Alternatively, a non-SICK Power pack with a voltage output of 24 V DC +20 %/–10 % (functional extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of 100 W. Cable no. 2 020 264 (3 m (9.84 ft)) with 15-pin D Sub HD connector and one open end for connecting the CLV to the non-SICK Power pack (supply voltage).

2.

The following operating voltages/power output values: – CDM 490-0001: 24 V DC +20 %/–10 % (pursuant to IEC 364-4-41), min. 100 W

Note

The CMP 490 Power Supply Module (output max. 25 W) is not suitable to provide the power supply for the CLV with heater. 3.

See pos. 3 under CLV without heater

3.1.4

Product features and functions (overview)

High-performance laser scanner: •

Line scanner (front-end reading window)

•

Scanner variant with oscillating mirror (side reading window)

•

Resolution variants: standard density, high density, low density

•

Dynamic focus (autofocus with distance measurement)

•

Alternatively dynamic focus control with external or internal trigger

•

Reading range 500 to 2,100 mm (19.7 to 82.7 in) (line scanner, standard density)

•

Resolution 0.25 to 1.0 mm (9.8 to 39.4 mil) (standard density)

•

Scanning/decoding frequency 600 to 1,200 Hz

•

Reading range can strongly be limited (3-dimensional reading space)

Safety and user-friendly features: •

Robust, compact metal housing, max. IP 65, CE certification

•

Laser class 2, laser diode switches off if reading interval is active for too long and if the output power is exceeded

•

Automatic self-test on startup. Can also be triggered at any time

•

Diagnosis tools for installing and monitoring the system

•

Parameterized output of reading diagnosis data in reading mode

•

Operating data query, and error messages

•

Test string function for signaling readiness for operation

•

Future proof thanks to firmware update via serial interface (flash PROM)

•

Low power consumption, other voltage range

Easy operation/configuration:

8 009 993/O824/20-12-2004

•

With "CLV-Setup" PC software for Windows

•

Alternatively with simple command strings, also for use with special devices

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-3

Page 26

Chapter 3

Product description

Operating Instructions CLV 490 Bar Code Scanner

•

Four status LEDs

•

External parameter memory optional) simplifies device replacement

Operating modes: •

Reading mode

•

Percentage evaluation - for assessing the quality of the reads

•

Special functions for system installation

Bar code evaluation: •

All standard bar code types

•

Max. 50 codes per reading pulse, max. 12 per scan

•

Code comparison (max. 5 matchcodes), can also be used as filter or sort criterion for the reading result

•

Sort sequences: code position, FIFO, LIFO, code length list, matchcodes

Reading pulse (start/stop mode): •

External reading pulse, via switching input(s) or serial interface

•

Timer (scanner with oscillating mirror: also oscillating extrema)

•

Free running

•

Object polling for on object per reading interval

Object Tracking (Tracking mode): •

Internal object tracking for max. 10 objetcs per reading interval

•

Extended object tracking (20 objetcs) in combination with OTS 400 Object Tracking System

Electrical interfaces: •

Serial host interface (RS 422/485 or RS 232) with variable transfer rate and telegram structure

•

Serial terminal interface (RS 232) as auxiliary data interface with special diagnosis and statistics functions

•

CAN interface for integration in the SICK CAN Scanner Network or a CANopen network, and for OTS operation

•

6 switching inputs for external reading pulse, focus control, encoder increment and special function (teach-in)

•

4 switching outputs for signaling defined events in reading mode

Connections: •

All interfaces are connected via two 15-pin D Sub HD connections on the housing

•

CDB 420 or CDM 490 Connection Module for connection to host and for integration in SICK CAN Scanner Network

•

CMF 400 Connection Module Fieldbus in the CDM 490 for connection to field bus systems

Additional functions:

3-4

•

Version with integrated heater (max. –35 °C (–31 °F))

•

External parameter memory in connector cover (optional)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 27

Product description

Operating Instructions

Chapter 3

CLV 490 Bar Code Scanner

3.1.5

Design ➋

➋

➋ Line scanner (front-end reading window)

Line scanner with oscillating mirror (side reading window)

➋

➊

➌

➍ ➎

➏

➐

➑

➒ Legend ➊ Drilled hole, Ø 3.6 mm (.14 in), 6 mm (.24 in) deep

➋ Laser warning labels ➌ Blind hole thread M6, 7 mm (.28 in) deep, for securing the device

Fig. 3-1:

➍ Blind hole thread M4, 10 mm (.39 in) deep, for the connector cover ➎ "Host/Term" connector 15-pin D Sub HD plug ➏ "I/O" connector, 15-pin D Sub HD socket

➐ LEDs (status indicators) ➑ Reading window ➒ Mark for count direction of the code position (deflection direction of the laser beam)

Design of the CLV 490

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-5

Page 28

Chapter 3

Product description

Operating Instructions CLV 490 Bar Code Scanner

3.2

Method of operation

The CLV first scans the bar code with a scan line and then decodes it. In stand-alone configuration, the data is forwarded via the serial host interface (main data interface) to a host/ PC for further processing, or via the CAN interface to the OTS 400 Omni Tracking System. An overview of the CLV functions is provided in Fig. 3-2. CLV 490 PC Operation Parameterization, etc. Photoelectric switch Reading pulse

HOST Further processing of the reading result

CAN bus Signal*) Focal control Trigger One-Shot Conveyer increment End of reading interval

Status display e. g. Device Ready e. g. Good Read e. g. No Read e. g. Match 1

*) if required Fig. 3-2:

Block diagram: CLV functions

The CLV is equipped with two decoders: •

The SMART decoder (SICK Modular Advanced Recognition Technology) for decoding bar codes with small code height, bar codes that are dirty or damaged, as well as bar codes that are tilted excessively (azimuth angle)

•

The tried-and-tested standard decoder of the CLV series

The CLV derives useful diagnosis data from the reading process and can transfer it to also the host. It also records operating data that can be interrogated at any time. The quality of the read can be checked in percentage evaluation mode. To start the reading process when an object is located in the reading field, the CLV requires a suitable trigger. This opens an internal time window ("reading interval") in the CLV. In the default configuration, this trigger is supplied by an external reading pulse sensor. Alternative trigger sources include Free-running mode or a command via the host interface (for more complex applications: object polling or OTS trigger). The current operating status is indicated by four LEDs. If the trigger is supplied externally, the "Sensor" switching input instructs the CLV to start the reading process. The five "IN 0" to "IN 4" switching inputs switch the focus position in response to certain events, as an alternative to the autofocus function. The "IN 3" and "IN 4” inputs can also be assigned special functions. The four "Result 1" to "Result 4" switching outputs can be assigned to different functions for displaying the result status and also control external devices, such as a PLC. The CLV is operated and configured via the serial terminal interface (auxiliary interface) using the "CLV-Setup" software or via the host interface/terminal interface using command strings.

3-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 29

Operating Instructions

Product description

Chapter 3

CLV 490 Bar Code Scanner

System and error messages help you to configure the device and to locate the source of errors during startup and reading mode. 3.2.1

Autofocus function

The autofocus function enables the CLV to detect the distance of an object during the reading process, without the need for external sensors, and then adjusts the focus position automatically to the reading plane of the bar code. In order to do so, the CLV measures the object distance each time in its reading field in front of the reading window and internally creates a distance profile. Following this, it positions the focus on the object. 3 operating modes are provided for various applications: •

Minimum distance: the CLV focuses on the minimum distance in the distance profile and ignores the background in the reading field. Application: with unobstructed view of the object without any surrounding objects protruding into the reading plane. One object with bar code(s) only is inside the reading field during one reading pulse.

•

Differential background: the distance profile of the reading field background is programmed (teach-in) in the CLV without any objects present. During the reading process, the CLV then focuses on the object which it recognizes by comparing the actual distance profile to the distance profile of the background. Application: with unobstructed view of the object restricted by other objects that protrude constantly into the reading plane. One object with barcode(s) only is inside the reading field during one reading pulse.

•

Differential background and tracking: if several objects with different distances to the CLV are positioned in the reading field at the same time (distance conflict), the CLV focuses on the object that is nearest to but has not exceed its internal focus switchover point. Application: in OTS operation (applications with internal tracking or tracking by the OTC 400 Omni Tracking Controller).

The distance profile of the background can also be displayed in the "CLV-Setup" program. The autofocus range is defined by the aperture angle, the autofocus space, and (in the case of line scanners with oscillating mirror) also by the angle of deflection. The park setting of the focus position, from which the device focuses for each read, can be specified in addition to a time and/or position-related delay (timeout or hysteresis). If necessary, an offset can be defined for the focus position to be set by the measurement. The depth of field, which radiates in the direction of the scan lines and is caused by the V-principle of the beam deflection, is optimized as a result (Fig. 3-3).

Measured distance Optimum focus position: measured distance plus offset for maximum Depth of field (DOF)

Fig. 3-3:

8 009 993/O824/20-12-2004

Optimization of the depth of field for the object

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-7

Page 30

Chapter 3

Product description

Operating Instructions CLV 490 Bar Code Scanner

In autofocus mode and in combination with the OTS 400 Omni Tracking System the CLV can also use the object height information from the OTS 400 or any other CLV transmitted via the CAN bus. 3.2.2

Event-controlled dynamic focus control

As an alternative to the autofocus function, the CLV can switch its focus position in response to certain events and thus dynamically cover a large reading range. A maximum of eight reading ranges can be defined as distance configurations for this purpose and approached consecutively in reading mode (see Fig. 3-4). Reading field height 1

2

3

4

5

6

7

8

Focus position

Reading distance DC 8 DC 6

Focus position

DC 7

DC 5 DC 4 DC 3 DC 2 DC 1 Reading distance DC = Distance Configuration

Fig. 3-4:

Dynamic focus control: classification of the reading range in distance configurations

The switch over takes place in response to changes in the object distance (with reads from above: object height detection). The trigger source for the switchover can be: •

A signal combination at the "IN 0" to "IN 4" switching inputs, a command on the host interface/terminal interface or the integrated timer (e. g. for search mode). Additional in the case of the line scanner with oscillating mirror also the oscillating mirror reversal points. The distance configurations are assigned to the switchover sequence by means of a programmable assignment table.

•

In combination with the OTS 400 Omni Tracking System: Alternatively the object height information from the OTS 400 or any other CLV via the CAN bus.

The distance measurement of the autofocus function can be additionally used to define the distance configurations. 3.2.3

Reading modes in stand-alone configuration

Start/stop mode During the reading process, only one object is located in the reading field in start/stop mode, i. e. all read bar codes can be clearly assigned to the object. As default, two reading pulse sensors at the beginning and at the end of the reading field control the starting and stopping of the reading process (Fig. 3-5). The size of the reading field is determined by the distance between the two sensors. Alternatively, the reading process can be controlled with

3-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 31

Operating Instructions

Product description

Chapter 3

CLV 490 Bar Code Scanner command strings via the data interface or can be left free running. The CLV either outputs the reading result at the end of the reading pulse (the back edge of the object has left the end of reading field) or already during the reading pulse as a result of predefined (parametrized) conditions. To separate bar codes of the same type with identical contents, an incremental encoder must be connected to the CLV. In object polling mode, the CLV automatically detects the beginning and the end of the object located in the reading field without any help of external sensors. The minimum temporal distance between two consecutive objetcs must not fall below 70 ms when the objects are moved on the conveyor belt. Tracking mode During the reading process, max. 10 objects can simultaneously be located in the reading field (following each other) in internal tracking mode, i. e. the CLV must be able to clearly assign the bar codes to the objects (Fig. 3-5). As default, a reading pulse sensor at the beginning of the reading field controls the starting of the reading process. The end of the reading field is determined by the parametrized object release point in the CLV. In this way, the size of the reading field is clearly determined. In order to track the transport of the objects in the reading field, a regularly-timed pulse is required. This is generated by an external incremental encoder which regularly supplies a pulse at least every 10 mm (0.39 in) of movement in conveying direction. As a result, the the distance between the reading pulse sensor and the object release point is clearly timemapped in the CLV. Fluctuations when approaching the conveyor or decreases in speed due to heavy load with numerous conveyor obejcts are also recorded. An internal clock in the CLV also allows operation at a constant conveyor speed. A gap of at least 50 mm (1.97 in) is necessary for the clear separation of consecutive objects. The reading result for an object is output after the back edge of the object passes the object release point. Alternatively, the reading process can be started with a command strings via the data interface. Start/stop mode

Fig. 3-5:

3.2.4

Tracking mode

Reading modes of the CLV in stand-alone configuration

Scan procedure variants

Line scanner (standard device) Generates a scan line; due to the V-principle of the beam generation, the reading field height (the useful length of the scan line for evaluation purposes) is dependent on the reading distance.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-9

Page 32

Chapter 3

Product description

Operating Instructions CLV 490 Bar Code Scanner

Line scanner with oscillating mirror The oscillating mirror also deflects the scan line perpendicularly to the scan direction at both sides around the neutral position with a low oscillating frequency. As a result, the CLV can also scan larger areas for bar codes. Due to the V-principle of beam generation, the reading field height is dependent on the reading distance. In addition to parking (fixed position) and simple deflection with maximum amplitude, optimized oscillating mirror functions are also available: •

Oscillating with variable deflection amplitude per distance configuration

•

One-Shot: one-off, defined deflection per reading pulse (forward and return phase)

3.2.5

Additional components

Heater The CLV can be permanently equipped with a heater for applications involving temperatures up to max. –35 °C (–31 °F) (e. g. in a freezer). The design, technical data, and power-up behavior of the CLV are described in Chapter 10.4 Optional heating, Page 10-40. External parameter memory in connector cover The external parameter memory is located in a connector cover which, when mounted, covers the two electrical terminals on the CLV (IP 65). The parameter memory saves you time when a CLV is replaced locally by providing a copy of the current parameter set. In other words, you do not have to configure the new device. For information on applications and operating procedures, see Chapter 10.3 Installing and operating the external parameter memory (connector cover), Page 10-34.

3.3

Indicators and control elements

3.3.1

Control elements

The CLV is operated and configured via the terminal interface (auxiliary interface) using the "CLV-Setup" program or using command strings sent via the host interface/terminal interface. A variety of parameter options allow you to adapt the device to a wide range of applications. The following can be defined: •

The configuration of the code types

•

The read, evaluation, and output properties

•

The communication parameters of the host interface/CAN interface

•

The structure of the data output string for "Good Read" and "No Read" on the host interface/CAN interface

•

The function of the terminal interface

Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-43 describes the procedure for installing the "CLV-Setup" program and explains how to use it. The parameterization (configuration) procedure is explained in Chapter 6.4 Configuring (parameterization) the CLV, Page 6-5.

3-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 33

Operating Instructions

Product description

Chapter 3

CLV 490 Bar Code Scanner

3.3.2

Function of the LEDs

Four LEDs indicate the operating status, activity of the laser diode, reading result status, and data transfer on the host interface. The LEDs are located on the rear of the device (Fig. 3-6). If the optional external parameter memory is connected, the LEDs also indicate whether the memory was successfully accessed.

Device Ready Sensor Read Result Data

Fig. 3-6:

LEDs

The meaning of the LEDs in the various operating modes/functions is shown in Table 3-2 and Table 3-3. CLV without external parameter memory: Operating mode LED Start

Display

Device Ready Green

Function • Lights up after power-up if the self-test was successful Subsequent behavior depends on selected start option:

Start option: START WITH EXTERNAL PARAMETERS (default) • Lights up constantly (CLV has loaded internal parameter set) Start option: START WITH INTERNAL PARAMETERS • Lights up constantly (CLV has loaded internal parameter set) Start option: START WITH COPY INTERN -> EXTERN • Blinks constantly together with the "Read Result" LED1) (CLV has loaded internal parameter set) Read Result Reading mode

Green

Start option: START WITH COPY INTERN -> EXTERN • Blinks constantly together with the "Device Ready" LED1)

Device Ready Green

• Lights up constantly • Extinguishes with new operating mode/function

Sensor

Green

• Lights up if reading diode is active (The laser diode is activated/deactivated by reading pulse) • Lights up constantly in Free-running mode, since laser diode is always active

Read Result

Green

LED is linked to the "Result 2" switching output and indicates the selected result status for the defined pulse duration of the output. • Lights up after a successful read (default: Good Read) • Lights up if the match code comparison is active, the bar code read matches the specified match code(s) and the corresponding result status output is selected for the "Result 2" output

Data

Yellow

• Flickers when the CLV transfers data to the host on the host interface

1) Set the start option to START WITH THE INTERNAL PARAMETERS on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. Download to CLV!

Table 3-2: Meaning of LEDs: CLV without external parameter memory

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-11

Page 34

Product description

Chapter 3

Operating Instructions CLV 490 Bar Code Scanner

Operating mode LED

Display

Function

Percentage

Sensor

Green

• Lights up constantly, as Free-running mode is active evaluation

Read Result

Green

Behavior depends on the reading quality: • Extinguishes if reading rate < 30 % • Blinks twice a second if reading rate 30 % to 70 % • Blinks five times a second if reading rate 70 % to 90 % • Lights up constantly if reading rate > 90 %

Adjusting mode Sensor

Green

• Lights up constantly, as Free-running mode is active

Show CP-limits

Green

• Blinks bright/dark alternately, in the frequency with which the scan line is (partially) masked out

Sensor

1) Set the start option to START WITH THE INTERNAL PARAMETERS on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. Download to CLV!

Table 3-2: Meaning of LEDs: CLV without external parameter memory (contd.)

CLV with external parameter memory connected a) External parameter memory in connector cover Operating mode LED

Display

Function

Start

Green

• Lights up after power-up if the self-test was successful

Device Ready

Subsequent behavior depends on selected start option: Start option: START WITH EXTERNAL PARAMETERS (default) • Blinks for approx. 10 s before lighting up constantly (CLV has loaded the parameter set from the external parameter memory and starts reading mode straight away) • Blinks for approx. 10 s together with the "Read Result" LED, then lights up constantly. (CLV has loaded the parameter set from the external parameter memory with tolerated errors1) and starts reading mode straight away) • Lights up constantly (CLV could not find an external parameter memory and loads the internal parameter set instead) • Blinks constantly together with the "Read Result" LED2) (The external parameter memory contains the parameter set for a different CLV type or is corrupt. CLV has loaded the internal parameter set. It starts Reading mode but does not output data over the host interface.) Start option: START WITH INTERNAL PARAMETERS • Lights up constantly (CLV has loaded internal parameter set) Start option: START WITH COPY INTERN -> EXTERN • Blinks alternately with the "Read Result" LED for approx. 10 s before lighting up constantly (CLV has successfully copied the internal parameter set to the external memory and has reset the start option to START WITH EXTERNAL PARAMETERS). CLV has loaded the internal parameter set. • Blinks constantly together with the "Read Result" LED2) (The external parameter memory is either not connected or corrupt, or the parameter set is too large to be copied). CLV has loaded the internal parameter set. 1) We recommend that you check the parameter set manually, e. g. by printing out the entire configuration. For troubleshooting, see also Chapter 8.3.2 LED error messages for the external parameter memory (connector cover), Page 8-3 2) Stops blinking when you switch from Reading mode to Parameterization mode

Table 3-3: Meaning of LEDs: CLV with external parameter memory in the connector cover

3-12

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004

Page 35

Operating Instructions

Product description

Chapter 3

CLV 490 Bar Code Scanner

Operating mode LED

Display

Function

Start – continued –

Green

Start option: START WITH EXTERNAL PARAMETERS (default) • Blinks for approx. 10 s together with "Device Ready" LED 1) (see above) or • Blinks constantly together with the "Device Ready" LED 2) (see above)

Read Result – continued –

Start option: START WITH COPY INTERN -> EXTERN • Blinks alternately with "Device Ready" LED for approx. 10 s (see above) or • Blinks constantly together with the "Device Ready" LED 2) (see above) Device Ready

Green

• Lights up constantly • Extinguishes with new operating mode/function

Sensor

Green

• Lights up if reading diode active (The laser diode is activated/deactivated by the reading pulse) • Lights up constantly in Free-running mode, since the laser diode is constantly active

Read Result

Green

LED is linked to the "Result 2" output and indicates the selected result status for the defined pulse duration of the output. • Lights up after a successful read (Good Read) • Lights up if the match code comparison is active, the bar code read matches the specified match code(s) and the corresponding result output is selected for the "Result 2" output

Data

Yellow

• Flickers when the CLV transmits data to the host over the host interface

Percentage

Sensor

Green

• Lights up constantly, since Free-running mode is active evaluation

Read Result

Green

Behavior dependent on the reading quality: • Extinguishes if reading rate < 30 % • Blinks twice a second if reading rate 30 % to 70 % • Blinks five times a second if reading rate 70 % to 90 % • Lights up constantly if reading rate > 90 %

Adjusting mode Sensor

Green

• Lights up constantly, since Free-running mode is active

Show CP-limits

Green

• Blinks bright/dark alternately, in the frequency with which the scan line is (partially) masked out

Reading mode

Sensor

1) We recommend that you check the parameter set manually, e. g. by printing out the entire configuration. For troubleshooting, see also Chapter 8.3.2 LED error messages for the external parameter memory (connector cover), Page 8-3 2) Stops blinking when you switch from Reading mode to Parameterization mode

Table 3-3: Meaning of LEDs: CLV with external parameter memory in the connector cover (contd.)

b) External parameter memory CMC 400 in the CDB 420/CDM 490 Connection Module The function of the "Device Ready" and "Read Result" LEDs on the CLV when using the CMC 400 as well as the remedy for error messages are described in the CMC 400 Operating Instructions (order no. 8 010 002, German/English). See also Chapter 10.3.1 Function of the external parameter memory, Page 10-35.

8 009 993/O824/20-12-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

3-13

Page 36

Product description

Chapter 3

Operating Instructions CLV 490 Bar Code Scanner

Notes:

3-14

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 993/O824/20-12-2004