Page 17
Operating Instructions
Notes on this document
Chapter 1
CLV 490 Bar Code Scanner
1
Notes on this document 1.1
Purpose
This document is a guide to the operation of the bar code scanner •
CLV 490 with auto-focus in the following variations: •
Line scanner – CLV 490-2010, resolution from 0.20 mm (7.9 mil) (high density) – CLV 490-2011, resolution from 0.20 mm (7.9 mil) (high density), with heater – CLV 490-0010, resolution from 0.30 mm (11.8 mil) (standard density) – CLV 490-0011, resolution from 0.30 mm (11.8 mil) (standard density), with heater – CLV 490-6010, resolution from 0.40 mm (15.7 mil) (low density) – CLV 490-6011, resolution from 0.40 mm (15.7 mil) (low density), with heater
•
Line scanner with oscillating mirror – CLV 490-3010, resolution from 0.20 mm (7.9 mil) (high density) – CLV 490-3011, resolution from 0.20 mm (7.9 mil) (high density), with heater – CLV 490-1010, resolution from 0.30 mm (11.8 mil) (standard density) – CLV 490-1011, resolution from 0.30 mm (11.8 mil) (standard density), with heater – CLV 490-7010, resolution from 0.40 mm (15.7 mil) (low density) – CLV 490-7011, resolution from 0.40 mm (15.7 mil) (low density), with heater
This document provides information on •
Mounting and connecting the device
•
Startup
•
Operating and configuring (parametrizing) the device
•
Maintenance
•
Exchanging the device without losing the parameter set
•
Special applications and procedures
The bar code scanner with all its variants will in this manual be referred to as the "CLV", except where a distinction is necessary.
1.2
Target audience
This document is intended for persons who are responsible for the following activities: 1.2.1
Mounting, electrical installation, maintenance and replacement
Electricians and service technicians. 1.2.2
Startup, operation and configuration
Technicians and engineers.
8 009 993/O824/20-12-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
1-1
Page 18
Notes on this document
Chapter 1
Operating Instructions CLV 490 Bar Code Scanner
1.3
Information content
This document contains all the information required to mount, install, and start up the CLV with the factory settings. A series of step-by-step instructions is provided for each of these activities. Configuration of the CLV for the application-specific reading situations is carried out with the Windows-oriented PC software "CLV-Setup". Further assistance is also available in the form of the online help system CLV-Setup Help. The procedure for installing and operating the software is described in the appendix. For further information on the design of the bar code scanner or on bar code technology in general, please contact the Division Auto Ident at SICK AG. Internet address: www.sick.com.
1.4
Symbols
Some of the information in this document is marked specially so that you can access it quickly: Warning Warnings are provided to prevent injury to operating personal or serious damage to the bar code scanner. ¾
Note Explanation Recommendation Tip Default SCANNING FREQUENCY
Always read warnings carefully and observe them at all times.
Indicates special features or characteristics. Explanations provide background information on technical features. Recommendations help you carry out certain procedures more effectively. Tips explain settings in the user interface of the "CLV-Setup" program. Marks a section containing the factory defaults. This typeface is used to refer to a term in the "CLV-Setup" program. Icons refer to buttons in the "CLV-Setup" program.
"Host receive fault"
This typeface is used for messages output via the terminal interface of the CLV. This symbol is used to mark sections that describe steps carried out with the "CLV-Setup" program.
This symbol refers to additional technical documentation.
1-2
¾
An action must be performed. This symbol characterizes single-step operating instructions. Multiple-step operating instructions are characterized by sequential numbers.
Ö
Here you select a function of the "CLV-Setup" user interface.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 19
Safety information
Operating Instructions
Chapter 2
CLV 490 Bar Code Scanner
2
Safety information 2.1
Authorized users
For the CLV to function correctly and safely, it must be mounted and operated by sufficiently qualified personnel. The end user must be supplied with the operating instructions. The end user must be provided with expert tuition and is advised to read the operating instructions. The following qualifications are required for the various tasks involved: 2.1.1
Mounting and maintenance
•
General technical training
•
Knowledge of the standard guidelines relating to safety at the workplace
2.1.2
Electrical installation and replacement
•
Practical training in electrical engineering
•
Knowledge of the standard safety guidelines relating to electrical engineering
•
Experience operating the devices in the relevant application (e. g. conveyor belt)
2.1.3
Startup, operation and configuration
•
Experience operating the devices in the relevant application (e. g. conveyor belt)
•
Knowledge of the hardware and software environment of the relevant application (e. g. conveyor belt)
•
Basic understanding of Windows 95TM/98TM, Windows NT4.0TM, Windows 2000TM or Windows XPTM
•
Ability to use an HTML browser (e. g. Internet ExplorerTM)
•
Basic understanding of data transfer methods
•
Basic understanding of bar code technology
2.2
Intended use
The CLV is designed to detect and decode bar codes automatically. It is mounted in a reading station and reads bar codes on objects positioned on a conveyor belt, for example. In stand-alone configuration the CLV transfers the data content of the decoded bar codes via its host interface to a host for further processing. Being integrated in the OTS 400 Omni Tracking System together with other CLVs, the CLV transfers the read results via its CAN interface to the OTC 400 Omni Tracking Controller. Any warranty claims vis-à-vis SICK AG will be rendered invalid if the device is used for any other purpose or if changes are made to the device, also as part of the mounting and electrical installation procedures. Note
8 009 993/O824/20-12-2004
Don’t open the device. The producer warranty will be forfeited if the device is opened.
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-1
Page 20
Chapter 2
Safety information
Operating Instructions CLV 490 Bar Code Scanner
2.3 ¾
General safety instructions and protection measures Always read the general safety instructions carefully and observe them at all times. Please also observe the warnings in front of the operating instructions in each chapter of this document.
Risk of injury by electrical current In the CDM 490 Connection Module, the optional CMP 490 Power Supply Module is connected to a mains voltage of 100 to 250 V AC/ 50 to 60 Hz. ¾
When working with electrical equipment, always follow the relevant safety specifications.
Laser beam can cause blindness. The CLV uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage your eyesight. The entire glass window acts as a laser outlet aperture. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ¾
As with sunlight, never look directly into the laser beam.
¾
Do not direct the laser beam at other persons.
¾
Mount and align the CLV in such a way to prevent the laser beam reflecting off mirrored surfaces.
¾
Do not open the housing. (Opening the housing does not deactivate the laser diode).
¾
Observe the laser protection specifications (latest version)
Laser power The laser operates at a wave length of λ = 650 nm (visible red light). The power output at the reading window is max. 2.8 mW. The emitted radiation is not dangerous to human skin. The product is classified in laser class 2 (laser class II) in accordance with EN 60825-1, IEC 60825-1, and 21 CFR 1040.10 (for publication date, see the warning sign on the device). Laser warnings The laser warning symbols (Fig. 2-1) can be found on the CLV at the following locations:
2-2
•
The laser warning symbol on line scanners is positioned beside the reading window on the front side of the device. The laser warning in GB English/US English is located on the side containing the electrical connections (see Fig. 3-1, Page 3-5.) The additional laser warnings in English applicable to the USA are positioned beside the reading window on the front side of the device and at the bottom of the device.
•
The laser warning symbol on line scanners with oscillating mirror is located above the reading window, on the cover of the mirror. The laser warning in GB English/US English is located on the side containing the electrical connections. The additional laser warnings in English applicable to the USA are positioned below the reading window on the front side of the device and at the bottom of the front side.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Page 21
Safety information
Operating Instructions
Chapter 2
CLV 490 Bar Code Scanner black-yellow signed on black-silver signed on device:
Fig. 2-1:
Note
Laser warning labels on the CLV
A set of laser warnings in German/US English and French/US English is included in the delivery scope. The GB English/US English warnings can be pasted over with these if necessary. If the CLV is installed in a machine/panel with the result that the laser warning labels are no longer visible, additional warnings (not included in the scope of delivery) must be provided on the machine beside the emergence aperture of the laser beam. Internal protective circuits The CLV is equipped with monitoring circuits that deactivate the laser diode in the event of a malfunction. No maintenance required to keep this product in compliance with laser class II. Activation and deactivation of the laser diode is controlled by the reading pulse (trigger source). A timer (laser timeout) automatically deactivates the laser diode in Reading mode ("Sensor input" and "Serial interface" trigger mode) if the reading interval has not ended after 10 minutes (default setting). However, it does not end the reading interval. In this case, the CLV outputs the message: "Laser safety timeout" on the terminal interface. The reading interval must be terminated by resetting the trigger signal. The laser diode is activated again by the next reading trigger. The laser timeout can be set in the range of 1 min to 25 h or deactivated (see Table 6-23, Page 6-37). In the "Percentage Evaluation" mode, "Adjusting" mode and "Show CP-limits" mode as well as in the pulse mode "Free-running", in reading mode, the laser diode is constantly activated. In the pulse mode "Object Polling" the laser diode is activated due to the parameterized search/pause ratio. In the "Background Analysis" function the laser didoe is constantly pulsed.
Note
8 009 993/O824/20-12-2004
In the Reading mode, the CLV carries out a distance measurement referencing at regular intervals. During referencing, it turns the laser diode on for a maximum of 10 seconds.
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-3
Page 22
Chapter 2
Safety information
Operating Instructions CLV 490 Bar Code Scanner
2.4
Quick stop and quick restart
2.4.1
Stopping the CLV
¾
Switch off the power supply or remove the cables of the CLV from the connection module.
This can result in loss of the following (at the most): •
The application-specific parameter set, if it was stored temporarily in the CLV
•
The last reading result
•
Daily operating data (operating hours counter, number of reading intervals, Good Read count, No Read count, maximum duration trigger, minimum duration trigger, matchcode 1 count, matchcode 2 count, no match count)
2.4.2 ¾
Restarting the CLV
Switch on the power supply or reattach the cables of the CLV to the connection module. The CLV resumes operation with the parameter set that was last stored permanently and reset the daily operating data.
2.5
Environmental information
The CLV is designed to cause minimum impact on the environment. It does not contain any silicone-based materials on the housing surface and, therefore, does not represent any problems for paint sprayers in paint shops, for example. 2.5.1
Power requirements
The power requirements depend on the variants: •
The line scanner has a typical power consumption of 11 W and max. 16 W
•
The line scanner with oscillating mirror has a typical power consumption of 13 W and max. 18 W
•
The line scanner equipped with an integrated heater has a typical power consumption of 75 W and max. 90 W
•
The line scanner with oscillating mirror equipped with an integrated heater has a typical power consumption of 75 W and max. 100 W
The values are given for devices with disconnected switching outputs. 2.5.2
Disposal after removal from service
Always dispose irreparable devices in a manner that is not harmful to the environment and in accordance with the applicable national waste disposal regulations. The CLV can be separated into recyclable secondary raw materials and special-category waste (electronic scrap). See also Chapter 7.3 Disposal, Page 7-2. SICK AG currently does not accept delivery of unusable or irreparable devices.
2-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004