Manual · Trimble
Trimble Survey Controller User Guide
Manual504 pagesPDF 5.9 MB
User guide for version 10.0 of the Trimble Survey Controller field software, run on the TSCe data collector for GPS and conventional surveys.
Covers · 1 model
The models it covers
Summary
What is in it
The full user guide for Trimble Survey Controller software version 10.0, the field software used on the Trimble TSCe data collector. It explains the screen, menus and data entry, coordinate systems and calibration, job management, data transfer to an office computer, feature and attribute libraries, roading, keyed-in data and Cogo calculations, GPS survey styles, setting up base and rover receivers (GPS Total Station 5700, 4800 and 4700), stakeout, and conventional instrument surveys.
Its parts
- General Operation
- Coordinate Systems
- Job Operations
- Data Transfer
- Using Feature and Attribute Libraries
- Roading
- Key In Menu
- Cogo Functions
- Offsets
- GPS Survey Styles
- Antennas
- Starting the Base Receiver
- Starting the Rover Receiver
- Calibration
- GPS Instrument Menu
From the manual
Key facts from this manual
Each line names its page in the PDF.
User guide for Trimble Survey Controller version 10.0, the field survey software that runs on the Trimble TSCe data collector. It explains jobs, coordinate systems, GPS and conventional surveys and data transfer, and an appendix describes the TSCe hardware: battery, screen, resets and care.
- What it is
- Data collector that runs Trimble Survey Controller software under Windows CE p. 434, 440
- Ports
- COM 1 DB9 connector, COM 2 DB26 connector, COM 2 0-shell Lemo connector, infrared (IRdA) p. 435
- Battery
- Rechargeable 4.8 volt, 3800mAh NiMH; over 30 hours of use per charge p. 436
- Charging
- AC adapter through the RS232 power supply Y-cable; about 1 hour to 90% capacity p. 437
- Display
- Reflective LCD readable in direct sunlight, with passive touch screen p. 438
- Storage
- Built-in storage card, shown as the \Disk folder p. 440
- PC connection
- Serial cable, USB cable, infrared or network (Ethernet) card, with Microsoft ActiveSync p. 93
- Temperature limits
- -20 C (-4°F) to +60 C (140°F) p. 441
- Water
- Immersible in up to one meter of water for up to one hour p. 442
- Drop
- Designed to withstand a MIL-STD-810E drop p. 441
- Display heater
- Runs from an external 12-volt battery; turns on below 0°C (32°F) p. 443
- Software version
- Trimble Survey Controller version 10.0; guide part number 44011-00-ENG Revision A, July 2001 p. 3, 4
What this manual walks you through
- Installing the battery p. 436, 437
- Charging the battery p. 437
- Calibrating the touch screen p. 438
- Setting the clock p. 439
- Soft and hard resets p. 440, 441
- Transferring files to an office computer p. 92, 93, 94, 95
- Transferring ASCII point data to other instruments p. 96
- Managing files with Windows CE Explorer p. 43
- Reading the GPS survey mode in the status line p. 45
- Caring for the unit and cleaning the screen p. 441, 442, 443
Good to know
- The TSCe cannot be charged through the Office Support Module II. p. 437
- A hard reset clears RAM, including desktop shortcuts; data on the \Disk storage card is kept. p. 441
- Changing the special system files on the storage card, such as nk.bin and ranger.reg, can stop the unit working. p. 440
- Connect to ActiveSync only as a Guest; partnership connections are not supported. p. 94
- ASCII transfer sends only points with grid coordinates; deleted points are not sent. p. 96
Questions this manual answers
What battery does the Trimble TSCe use?
A rechargeable 4.8 volt, 3800mAh NiMH battery, which gives over 30 hours of use per charge. p. 436
How do I charge the TSCe?
Connect it to the AC adapter with the RS232 power supply Y-cable; it reaches about 90% in roughly 1 hour. p. 437
How do I reset a frozen TSCe?
Turn it off and on; if that fails, do a soft reset, which loses no data. A hard reset clears RAM but keeps the \Disk folder. p. 440, 441
How do I connect the TSCe to a PC?
By serial cable, USB cable, infrared or an Ethernet card, using Microsoft ActiveSync with a Guest connection and the Trimble Data Transfer utility. p. 93, 94
Is the TSCe waterproof?
The guide says it is designed to be immersible in up to one meter of water for up to one hour, with the battery screws tight. p. 442
Contents
Chapters and sections
Each line opens the PDF at its page.
- Trimble Survey Controller™1
- About This Manual21
- General Operation25
- Coordinate Systems47
- Job Operations65
- Data Transfer91
- Using Feature and Attribute Libraries105
139 more lines, from page 107 on
- Creating a Feature and Attribute Library107
- Roading115
- Key In Menu145
- Cogo Functions175
- Offsets207
- GPS Survey Styles215
- Antennas241
- Starting the Base Receiver247
- Starting the Rover Receiver271
- Introduction272
- Setting Up the Equipment for a Real-Time Survey272
- Setting Up the Equipment for a Postprocessed Survey279
- Setting Up the Equipment for a Real-Time and Postprocessed Survey281
- Starting a Rover Survey281
- Starting a Wide-Area RTK Survey286
- RTK Initialization Methods288
- Recommended RTK Initialization Procedure290
- Postprocessed Initialization Methods291
- Swapping Bases During a Real-Time Rover Survey293
- Ending a Rover Survey293
- Calibration295
- GPS Instrument Menu307
- GPS Point Measurement317
- Introduction318
- Measuring a Topo Point in a GPS Survey318
- Measuring a FastStatic Point319
- Measuring an Observed Control Point320
- Measuring a Rapid Point321
- Measuring Continuous Topo Points321
- Measuring an As-Staked Point322
- Measuring a Laser Point323
- Measuring a Calibration Point323
- Measuring a Check Point324
- Next Free Point Name Search324
- Storing Points325
- GPS Stakeout331
- Conventional Instrument Survey Styles353
- Starting a Conventional Survey367
- Measuring Points and Rounds383
- Conventional Stakeout401
- Conventional Instrument Menu419
- Laser Observations427
- The TSCe Data Collector433
- Database Search Rules445
- Conventional Instrument Settings455
- Glossary465
- Index475
- Reader Comment Form503
The whole text · 56 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Trimble Survey Controller™1-6
- Contents7-20
- About This Manual21-24
- General Operation, pages 25 to 3225-32
- General Operation, pages 33 to 4033-40
- General Operation, pages 41 to 4641-46
- Coordinate Systems, pages 47 to 5547-55
- Coordinate Systems, pages 56 to 6456-64
- Job Operations, pages 65 to 7365-73
- Job Operations, pages 74 to 8274-82
- Job Operations, pages 83 to 9083-90
- Data Transfer91-104
- Using Feature and Attribute Libraries105-114
- Roading, pages 115 to 124115-124
- Roading, pages 125 to 134125-134
- Roading, pages 135 to 144135-144
- Key In Menu, pages 145 to 154145-154
- Key In Menu, pages 155 to 164155-164
- Key In Menu, pages 165 to 174165-174
- Cogo Functions, pages 175 to 182175-182
- Cogo Functions, pages 183 to 190183-190
- Cogo Functions, pages 191 to 198191-198
- Cogo Functions, pages 199 to 206199-206
- Offsets207-214
- GPS Survey Styles, pages 215 to 223215-223
- GPS Survey Styles, pages 224 to 232224-232
- GPS Survey Styles, pages 233 to 240233-240
- Antennas241-246
- Starting the Base Receiver, pages 247 to 254247-254
- Starting the Base Receiver, pages 255 to 262255-262
- Starting the Base Receiver, pages 263 to 270263-270
- Starting the Rover Receiver, pages 271 to 278271-278
- Starting the Rover Receiver, pages 279 to 286279-286
- Starting the Rover Receiver, pages 287 to 294287-294
- Calibration295-306
- GPS Instrument Menu307-316
- GPS Point Measurement317-330
- GPS Stakeout, pages 331 to 338331-338
- GPS Stakeout, pages 339 to 346339-346
- GPS Stakeout, pages 347 to 352347-352
- Conventional Instrument Survey Styles353-366
- Starting a Conventional Survey, pages 367 to 374367-374
- Starting a Conventional Survey, pages 375 to 382375-382
- Measuring Points and Rounds, pages 383 to 391383-391
- Measuring Points and Rounds, pages 392 to 400392-400
- Conventional Stakeout, pages 401 to 409401-409
- Conventional Stakeout, pages 410 to 418410-418
- Conventional Instrument Menu419-426
- Laser Observations427-432
- The TSCe Data Collector433-444
- Database Search Rules445-454
- Conventional Instrument Settings455-464
- Glossary465-474
- Pages 475 to 484475-484
- Pages 485 to 494485-494
- Pages 495 to 504495-504
The file