Page 433

APPENDIX

A A

The TSCe Data Collector In this chapter: ■

Introduction

■

Power source

■

Operating the TSCe data collector

■

Caring for the unit

Page 434

A

A.1

The TSCe Data Collector

Introduction The Trimble Survey Controller software is designed to run on the TSCe data collector. This Appendix introduces the hardware and describes how to use it. Figure A.1 shows a front view of the TSCe data collector and its main keys.

Tab Tab

On / Off Del

Enter Keys Alt

Alt

Shift

7

8

9

4

5

6

1

2

3

Keys

,

0

Ctrl

_

+

Esc

C

D

E

F

I

J

K

L

P

Q

/

* Copy

A

B

G

H

M

N

O

S

T

U

W

Undo Y

Z

\

Mic

Figure A.1

41 0

Esc

R

Cut

Paste V

Ctrl

X

Microphone Spacebar

The TSCe data collector – front view

Trimble Survey Controller User Guide

Page 435

The TSCe Data Collector

A

The following keys perform these functions: •

Enter – activates the selected item

•

Control (Ctrl) – activates the functions in purple above the keys

•

Shift – activates the functions in yellow above the keys

•

Escape – cancels the current task

Figure A.2 shows a top view of the TSCe data collector.

IRdA

COM 1 - DB9 connector

COM 2 - DB26 connector

COM 2 - 0-shell Lemo connector

Figure A.2

The TSCe data collector – top view

Trimble Survey Controller User Guide

411

Page 436

A

The TSCe Data Collector

A.1.1

Shortcut Keys A shortcut key is a key combination that you can press to carry out a command without first selecting from a menu. See Table A.1. Table A.1

Shortcut keys

Command Display contrast Windows Start menu Windows CE Task Manager Touch Screen Calibration Delete files in Explorer Copy

+ or

+

+

+ +

+

+ +

Paste

+

Switch between programs

A.2

A. A, CE AT AC+ ~{ Cc Cv AT AE

Shortcut key combination

+ or

+

Power Source The TSCe data collector is supplied with a rechargeable 4.8 volt, 3800mAh NiMH battery. This battery provides over 30 hours of use per charge.

A.2.1

Installing the Battery To install the battery:

41 2

1.

Remove the handstrap from the battery door.

2.

Use a screwdriver to completely loosen the four screws on the backcase.

3.

Connect the battery to the white plug in the case. It will only connect one way.

Trimble Survey Controller User Guide

Page 437

The TSCe Data Collector

A.2.2

A

4.

Insert the battery into the battery compartment. Tuck the wires to the left to prevent them from becoming pinched.

5.

Replace the backcase and tighten the four screws firmly.

Charging the Battery The TSCe data collector incorporates a quick circuit that recharges the NiMH battery to 90% capacity in approximately 1 hour. To recharge the battery, connect the TSCe to the AC adapter using the RS232 power supply Y-cable. The TSCe data collector should turn on and start the initial boot process. Recharge the TSCe data collector for a minimum of two hours before using it on battery power alone.

_

The TSCe data collector remains on to monitor the battery while it is charging. To turn off the display, press the key. Note – You cannot connect the TSCe data collector through the Office Support Module II for charging.

A.2.3

Changing the Battery Contact your local dealer for a replacement battery. When changing the battery, close all applications and save the data. Resetting a unit or changing the batteries has no effect on stored data or flash memory.

Trimble Survey Controller User Guide

413

Page 438

A

A.3

The TSCe Data Collector

Operating the TSCe Data Collector This section describes how to operate the features of the TSCe data collector.

A.3.1

Screen The TSCe data collector has a reflective LCD screen that can be viewed in direct sunlight. The screen incorporates highly reflective mirrors behind the display that make it bright and easy to read, even in overcast conditions. The screen also incorporates a passive touch interface. This lets you navigate around the system by touching elements on the display screen with a stylus or your finger. Calibrating the touch screen If the touch screen is not responding properly to taps, you may need to calibrate the touch screen. To start the calibration procedure: 1.

41 4

AC+

Do one of the following: +

+

.

–

Press

–

Tap and select Settings / Control Panel / Stylus. The Stylus Properties dialog appears. From the Calibration tab, tap [Recalibrate].

2.

Follow the on screen prompts by tapping the target as it moves from the center of the screen to each corner. If the calibration fails, repeat the procedure.

3.

If the calibration is successful, press settings. Press to keep the old settings.

E

Trimble Survey Controller User Guide

= to accept the new

Page 439

The TSCe Data Collector

A

Adjusting the double-tap speed To adjust the stylus double-tap speed: 1.

Tap and select Settings / Control Panel / Stylus.

The Stylus Properties dialog appears. 2.

B

From the Double-Tap tab, double-tap the checkerboard grid to set the speed at which software applications will recognize your double-taps.

Tip – Double-tap the clapboard icon to test your settings. If the icon does not change, adjust your setting again.

Movement on the screen

=

To move around the screen, do one of the following:

A.3.2

.

=

•

Use the cursor keys and press

•

Use the stylus or your finger to tap or double-tap

•

To move a screen object, press the stylus or your finger on the object, while dragging across the screen.

.

Setting the Clock To change the TSCe data collector time and date settings: 1. Do one of the following: – Double-tap on the clock located on the right side of the taskbar. – Tap and select Settings / Control Panel / Date/Time. The Date/Time Properties dialog appears. 2. Change the date and time as required. Press to accept the new settings or to cancel.

E

=

Note – When you connect the TSCe data collector to the GPS receiver, the date and time are updated.

Trimble Survey Controller User Guide

415

Page 440

A A.3.3

The TSCe Data Collector

Adding an Item to the Desktop To add a program to the computer desktop:

A.3.4

1.

Double-tap My Computer.

2.

Select the file or program to be added to the desktop, then tap File / Send To / Desktop as Shortcut.

Storage Card The TSCe data collector has a built-in storage card that may be used to store your data and programs. This appears in the Windows CE files system as the \Disk folder. Windows CE system maintains several special files on this card, such as nk.bin and ranger.reg. The files contain crucial information necessary for the correct operation of the TSCe data collector. Directly modifying these files may result in the TSCe data collector failing to operate correctly.

A.3.5

Rebooting If the TSCe data collector fails to respond to keystrokes, you may need to reboot the system. Turn off the data collector and turn it back on again. If this does not work then perform a soft reset. Soft reset A soft reset (warm boot) shuts down the hardware and restarts the Trimble Survey Controller software. You will not lose any data by performing a warm boot.

~ C

To perform a soft reset: •

Hold down and

, while you press and release

_

.

The TSCe data collector will reset to the default Microsoft Windows desktop view.

41 6

Trimble Survey Controller User Guide

Page 441

The TSCe Data Collector

A

Hard reset You will not lose any data that is stored on the built-in storage card (the \Disk folder) by performing a hard reset (cold boot). The contents of the RAM memory will be cleared, including any desktop shortcuts that you have created.

_

To perform a hard reset: 1.

Hold down

.

After approximately 5 seconds, a dialog and a countdown timer appear, indicating that the TSCe data collector will reset. 2.

Continue to hold

_ for 5 seconds, then release.

The TSCe data collector will briefly display the boot screen and then reset to the default Microsoft Windows desktop view.

A.4

Caring for the Unit Trimble recommends the following to maintain your TSCe data collector during everyday use, as well as preventing potential physical damage or data loss. Temperature Do not expose the unit to temperatures below –20 C (–4°F) or above +60 C (140°F). Do not leave it in direct sunlight for extended periods of time. Shock The unit is designed to withstand a MIL-STD-810E drop. However, impact or pressure on the display screen can cause it to crack. Protect the display from impact, pressure, or abrasive substances.

Trimble Survey Controller User Guide

417

Page 442

A

The TSCe Data Collector

Water The TSCe is designed to be immersible in up to one meter of water, for up to one hour. Ensure that the battery compartment screws are secured tightly when replacing the battery. Note – Removal of the backcase screws voids the warranty. Cleaning the case Clean the unit with a soft cloth dampened with clean water or with water containing a mild detergent. If the keyboard has dirt or grime on it, use compressed air or a vacuum cleaner, or gently rinse it with clean water. Care of touch screen Keep the touch screen clean using a soft cloth dampened with clean water or glass cleaner. Do not apply any cleaner directly to the screen - apply the cleaner to the soft cloth and then gently wipe the screen. Note – Do not use any abrasive cleaners. Applying a screen protector Use a screen protector to help keep the touch screen clean and protected. Clean the screen thoroughly and leave it slightly wet. Peel the backing from the screen protector before applying it to the screen. Use a soft cloth to squeeze the excess water and air from under the screen protector. Safeguarding data Back up your work regularly using Microsoft ActiveSync or the Trimble Data Transfer utility.

41 8

Trimble Survey Controller User Guide

Page 443

The TSCe Data Collector

A

ESD protection All computers are susceptible to electrostatic discharges. Before using the TSCe data collector, discharge any built-up static by grounding yourself to a non-electronic item. Display heater Use the display heater by plugging in an external 12-volt battery. If the internal temperature drops below 0°C (32°F), the heater will automatically turn on to warm the unit.

Trimble Survey Controller User Guide

419

Page 444

A

42 0

The TSCe Data Collector

Trimble Survey Controller User Guide