The text of a manual · part 49 of 56
Trimble Survey Controller User Guide: Laser Observations
Pages 427 to 432 of 504, from Trimble Survey Controller User Guide
The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSCe
Page 427
CHAPTER
23 23
Laser Observations In this chapter: ■
Introduction
■
Configuring the Trimble Survey Controller software
■
Configuring the laser
■
Taking a measurement with the laser rangefinder
■
Laser softkey
Page 428
23
Laser Observations
23.1
Introduction If a point cannot be occupied directly by a GPS rover, one way to measure it is to use a laser rangefinder with the Trimble Survey Controller software. This combination of laser rangefinder and Trimble Survey Controller software can also be used with a conventional instrument. Alternatively, the laser rangefinder can be plugged into the TSCe data collector and used on its own with the Trimble Survey Controller software. The Trimble Survey Controller software supports the following laser rangefinders: •
Laser Technology Criterion 300
•
Laser Technology Criterion 400
•
Laser Technology Impulse
•
Laser Atlanta Advantage CI
•
Leica Disto memo
•
Leica Disto pro
•
MDL LaserAce 300
•
MDL Generation II Surveyor
Note – Contact your local Trimble dealer for a current list of lasers supported by the Trimble Survey Controller software.
23.2
Configuring the Trimble Survey Controller software Before you use a laser rangefinder with the Trimble Survey Controller software, you must configure an appropriate survey style. A laser rangefinder can be used with any survey style. To configure the survey style:
40 4 f
1.
From the main menu, choose Configuration / Survey styles. . Highlight a survey style and tap
2.
Select Laser rangefinder.
Trimble Survey Controller User Guide
Page 429
Laser Observations
23
3.
Select one of the instruments in the Type field.
4.
If necessary, configure the Controller port and Baud rate fields. The default value in the Baud rate field is the manufacturer’s recommended setting.
m
If the Trimble Survey Controller software can automatically , instruct the laser to take a measurement when you tap you can edit the Auto measure field as required. 5.
Set the Auto store point check box as required.
E
The precision fields contain the manufacturer’s precision values . for the laser. They are for information only. Tap
23.2.1
Magnetic Declination Most lasers have a magnetic compass. Make sure that this compass is calibrated before taking any measurements. When you enter a value for magnetic declination in the Trimble Survey Controller software, it is applied to all subsequent laser measurements. To enter a value for magnetic declination: 1.
Select Configuration / Job / Cogo settings.
2.
Enter a value in the Magnetic declination field. For more information about magnetic declination, see page 65.
C
Warning – If you enter a value for magnetic declination in the Trimble Survey Controller software, make sure that no magnetic declination value is set in the laser.
Trimble Survey Controller User Guide
405
Page 430
23
Laser Observations
23.2.2
Vertical Angle Display The laser measurements can be displayed as vertical angles measured from the zenith or inclinations measured from horizontal. Select a display option in the Laser VA display field in the Units screen. For more information, see System Units, page 58.
23.3
Configuring the Laser Before using the laser with the TSCe data collector, configure the laser options. Table 23.1 shows the configuration for each laser that is supported by the Trimble Survey Controller software. Table 23.1
Laser Settings
Laser
Laser setting
LTI Criterion 300 or LTI Criterion 400
From the main menu, press the down arrow or up arrow key until the Survey menu appears, then press . Select Basic measurements and press . A screen showing the fields HD and AZ appears.
LTI Impulse
Set up the laser to operate in CR 400D format. Make sure that a small d is displayed on the screen. (If necessary, press the Fire2 button on the laser).
Laser Atlanta Advantage
Set the Range/Mode option to Standard (Averaged) and the Serial/Format option to Trimble Pro XL.
Leica Disto memo/pro
Set the unit to meters or feet, not feet and inches.
MDL Generation II
No special settings are required.
MDL LaserAce
Set the Data record format to Mode 1. When using the angle encoder, set the magnetic declination to zero in the Trimble Survey Controller software. The angle encoder in the LaserAce corrects for the magnetic declination.
E
E
Note – You must configure the laser rangefinder to update the inclinometer and slope distance readings after each measurement.
40 6
Trimble Survey Controller User Guide
Page 431
Laser Observations
23.4
23
Taking a Measurement with the Laser Rangefinder To measure a point with the laser rangefinder: 1.
Configure the survey style that you intend to use. Note – If the Measure laser points option does not appear in the Survey menu, specify the laser type you are using in the Laser rangefinder type field in the survey style.
2.
Connect the laser to the TSCe data collector.
3.
Make sure that the laser is set up to take azimuth and distance measurements, and inclination (the last is optional).
4.
From the Trimble Survey Controller main menu, choose Survey. . Highlight the required survey style and tap
5.
Select Measure laser points.
6.
Enter a value in the following fields:
7.
E
–
Point name.
–
Code (if required).
–
Start point – enter the name of the point that laser measurements are to be taken from.
–
Laser height (if required).
–
Target height (if required).
M
. Follow the Occupy the start point with the laser and tap instructions on the TSCe data collector display screen. Wait for the laser compass to settle before taking a measurement.
M
If the Auto measure field in the survey style Laser Rangefinder option is set to Yes, the Trimble Survey Controller software . instructs the laser to take a measurement when you tap The Trimble Survey Controller software displays this measurement when it receives it.
Trimble Survey Controller User Guide
407
Page 432
23
Laser Observations
B m
Tip – You can take a measurement on the laser without tapping first. The laser measurement is displayed on the screen of the TSCe data collector when the data is received.
If the Trimble Survey Controller software receives only a distance measurement from the laser, another screen is displayed with the measured distance in a Slope distance field. Enter a vertical angle if the measured distance was not horizontal. 8.
Tap s to store the point.
Note – If you are using a laser without a compass, you must key in a magnetic azimuth before the Trimble Survey Controller software can store the point.
23.5
M
Laser Softkey
In most H. Dist (horizontal distance) fields and S. Dist (slope distance) fields in the Trimble Survey Controller software, there is a softkey. Use it to measure a distance with the laser and insert that value in the H.Dist field. This function is useful when calculating an offset or intersection point. To use the laser in the H.Dist field:
40 8
M
1.
Configure the laser in the survey style that you intend to use, and start the survey in that style.
2.
Access the H.Dist field and tap the screen.
3.
When the Trimble Survey Controller software receives the measurement, it inserts the horizontal distance into the H.Dist field.
Trimble Survey Controller User Guide
. Follow the instructions on