The text of a manual · part 48 of 56

Trimble Survey Controller User Guide: Conventional Instrument Menu

Pages 419 to 426 of 504, from Trimble Survey Controller User Guide

The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSCe

Page 419

CHAPTER

22 22

Conventional Instrument Menu In this chapter: ■

Introduction

■

Station setup details

■

Instrument controls

■

Target

Page 420

22

22.1

Conventional Instrument Menu

Introduction The Instrument menu provides information about the instrument that is connected to the TSCe data collector. This menu appears when you choose the Instrument icon from the main menu. If a conventional instrument is connected to the data collector, the items in the Instrument menu are:

22.2

•

Station setup details

•

Target

•

Instrument controls (optional - this is available when a servo or robotic instrument is connected).

Station Setup Details If the TSCe data collector is connected to a conventional instrument, select Instrument / Station setup details to view the instrument type and current station setup information.

B

Tip – You can also access the station setup details from the status bar by tapping the conventional instrument icon. If you are connected to a servo or robotic instrument, tap the conventional instrument icon to open the Instrument controls screen.

39 6

Trimble Survey Controller User Guide

Page 421

Conventional Instrument Menu

22.3

22

Instrument Controls If the TSCe data collector is connected to a servo or robotic conventional instrument, use the Instrument controls option to control the movement of the instrument, as shown in the following screen:

If you are using a robotic instrument, you can use the TSCe data collector to operate the instrument remotely by radio. This lets the TSCe data collector guide the instrument to measure or stakeout points from the target (prism).

B 22.3.1

Tip – To access the Instrument controls screen, tap the instrument icon on the status bar.

Turning the Instrument Choose one of the following methods to turn the instrument: HA & VA

ã

To turn the instrument to a specified angle, do one of the following: •

To turn the instrument to a horizontal angle only, enter the . horizontal angle in the Turn to HA field. Tap • To turn the instrument to a horizontal and vertical angle, enter the horizontal angle in the Turn to HA field and the vertical angle in the Turn to VA field. Tap . The instrument turns to the angle(s) you entered.

ã

Trimble Survey Controller User Guide

397

Page 422

22

Conventional Instrument Menu

ã

Point Name

To turn the instrument to a specified point, enter a point name in the . Point name field and tap The instrument turns to the point you entered.

22.3.2

ç

Changing the Face

To switch between face 1 and face 2 (direct and reverse) of the instrument, tap . The message Please wait. Instrument turning appears and then the instrument turns to the opposite face.

39 8

Trimble Survey Controller User Guide

Page 423

Conventional Instrument Menu 22.3.3

22

è

Locating and Locking on to the Target When you operate the instrument remotely from the target (prism), the softkey appears in the Instrument controls screen. Use the softkey to turn the instrument towards the target when lock has been lost.

è

To turn the instrument towards the target: . The following screen appears:

1.

Tap

2.

, , , and on Tap an arrow on the screen or press the keypad to select a direction to turn the instrument. The instrument will turn in the direction indicated by the solid/filled arrow, as shown in the following screen:

<>( )

) (

Note – When the instrument is on face 2, the up and down arrows are reversed. For example, if you press , the instrument will turn in an upwards direction. If you press the instrument will turn in a downwards direction. Trimble Survey Controller User Guide

,

399

Page 424

22

Conventional Instrument Menu

3.

Select the same direction to increase the instrument turning speed. The second directional arrow becomes solid. Select the same arrow to decrease the speed again.

4.

or another arrow to stop the instrument from turning. Tap The directional arrows becomes hollow. The instrument now points towards the target.

9 æ

To make the instrument locate and lock on to the target: •

Tap

.

The message Searching... appears on the screen and the instrument starts searching for the target. The search results appear as the following status line messages: •

Target Locked – indicates that the target has been located and tracking locked.

22.3.4

•

Target Detected – indicates that the target has been located (when the instrument is in servo mode).

•

No Target – indicates that the target was not located.

Tracklight Support for Trimble and Geodimeter Robotic Instruments When you use a Trimble 5600 Series and Geodimeter System 600 Robotic instrument that is set up with a Tracklight unit, you can use the Trimble Survey Controller software to set the intensity of the guide-light.

t hN O

To set the Tracklight unit: Tap

2.

Do one of the following: – – –

40 0

.

1.

Tap to emit the guide-light at a high intensity.

Tap to emit the guide-light at normal intensity.

Tap to turn the Tracklight unit off.

Trimble Survey Controller User Guide

Page 425

Conventional Instrument Menu

22.4

22

Target If the TSCe data collector is connected to a conventional instrument, select Instrument / Target to view the target height and the prism constant currently in use.

B

Tip – To access the target details, tap the prism icon on the status bar.

Trimble Survey Controller User Guide

401

Page 426

22

Conventional Instrument Menu

40 2