Page 279

Starting the Rover Receiver

13.3

13

Setting Up the Equipment for a Postprocessed Survey This section shows how to assemble the hardware at the rover receiver for a postprocessed kinematic (PP kinematic) survey or a FastStatic survey. It describes the steps for a Trimble GPS Total Station 5700, 4800, or 4700 receiver.

13.3.1

Using a GPS Total Station 5700 Receiver To assemble the rover receiver hardware for a postprocessed survey, see Figure 13.1 on page 249. Then do the following:

C

1.

Attach the Zephyr antenna to a range pole.

2.

Connect the GPS antenna to the GPS receiver port labeled “ANTENNA”. Use the N-type to Lemo co-axial cable.

3.

Connect the Zephyr antenna to the yellow GPS receiver port labeled “GPS”. Use the yellow GPS antenna cable (part number 41300-10).

Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.

4.

Connect the power source to the GPS receiver port 2 and turn on the receiver.

5.

Connect the TSCe data collector to the GPS receiver port 1. Use the 0-shell Lemo to 0-shell Lemo cable.

6.

Turn on the TSCe data collector, then follow the instructions in Starting a Rover Survey, page 257.

Trimble Survey Controller User Guide

255

Page 280

13 13.3.2

Starting the Rover Receiver

Using a GPS Total Station 4800 Receiver To assemble the rover receiver hardware for a postprocessed survey, see Figure 13.2 on page 251. Then do the following:

C

1.

Attach a battery to the PowerLiTE range pole.

2.

Attach the 4800 receiver to the PowerLiTE range pole and turn it on. The power is supplied from the battery in the range pole.

3.

Connect the TSCe data collector to the GPS receiver port 1.

Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.

4.

13.3.3

Turn on the TSCe data collector, then follow the instructions in Starting a Rover Survey, page 257.

Using a GPS Total Station 4700 Receiver To assemble the rover receiver hardware for a postprocessed survey, see Figure 13.3 on page 253. Then do the following:

C

25 6

1.

Attach the GPS antenna to a range pole.

2.

Connect the GPS antenna to the GPS receiver port labeled “ANTENNA”. Use the N-type to Lemo co-axial cable.

Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.

3.

Connect the power source to the GPS receiver port 2 and turn on the receiver.

4.

Connect the TSCe data collector to the GPS receiver port 1. Use the 0-shell Lemo to 0-shell Lemo cable.

5.

Turn on the TSCe data collector, then follow the instructions in Starting a Rover Survey, page 257.

Trimble Survey Controller User Guide

Page 281

Starting the Rover Receiver

13.4

13

Setting Up the Equipment for a Real-Time and Postprocessed Survey A survey style such as RTK & infill uses both real-time and postprocessed techniques. To conduct this type of survey, assemble the rover exactly as for a real-time survey. If the receiver has no memory (or limited memory), leave the TSCe data collector connected to the base receiver for the purpose of data storage. You need another TSCe data collector for the rover receiver.

13.5

Starting a Rover Survey Only start a survey after you have started the base receiver. For more information, see Chapter 12, Starting the Base Receiver. To conduct a survey: 1.

Make sure that the required job is open. The title of the main menu should be the current job name.

2.

From the main menu, choose Survey. Select a survey style from the list. This must be the same survey style that you use for the base survey.

A Survey menu is generated. It displays items specific to the chosen survey style and includes the Start base receiver and Start survey items. When you start a survey using a particular Trimble survey style for the first time, the Trimble Survey Controller software prompts you to customize the style for your specific hardware. For more information, see The Style wizard, page 197. When the survey starts, the menu items Start base receiver and Start survey no longer appear. For kinematic surveys, a new item, Initialization, appears.

Trimble Survey Controller User Guide

257

Page 282

13

Starting the Rover Receiver

GPS Total Station 5700, 4800, or 4700 receiver If the TSCe data collector is connected to a GPS Total Station 5700, 4800, or 4700 receiver that was logging data, the data logging stops. Data logging is restarted, in a different file, if you start a survey using a survey style that specifies data logging. Note – When you start a survey, the Trimble Survey Controller software automatically negotiates the highest possible baud rate for communicating with the connected receiver.

13.5.1

Starting a Real-Time Rover Survey To start the rover receiver for a real-time survey: 1.

Select Start survey.

2.

Make sure the rover is receiving radio corrections from the base. Note – An RTK survey needs radio corrections.

3.

If the receiver you are using supports transmission delays and you select the Prompt for station index check box in the Rover options field, the Select base station screen appears. It shows all the base stations operating on the frequency you are using. The list shows the station index numbers of each base and the reliability of each. Highlight the base you want to use and tap .

E

For more information about using transmission delays, see Operating Several Base Stations on One Radio Frequency, page 235.

B

25 8

Tip – If you want to check the point name of the base station being used in the rover survey, select Files / Review current job and inspect the Base point record.

Trimble Survey Controller User Guide

Page 283

Starting the Rover Receiver

4.

13

If necessary, initialize the survey. For a differential survey, no initialization is necessary, and you can start to survey immediately. For more information, see Chapter 16, GPS Point Measurement.

I

Note – If you are carrying out an RTK survey but do not require centimeter-level results, select Survey / Initialization. Tap and set the Method field to No initialization. For an RTK survey, initialize before starting centimeter-level surveying. If you are using a dual-frequency receiver with the OTF option, the survey automatically starts to initialize using the OTF initialization method. 5.

13.5.2

When the survey is initialized, you can perform a site calibration, measure points, or stakeout.

Starting an RTK & Infill Rover Survey Note – If you are using postprocessed techniques, to process the data you must have the Baseline Processing module of the Trimble Geomatics Office software installed. To start the rover receiver for an RTK & infill survey: 1.

Select Start Survey.

2.

Make sure the rover is receiving radio corrections from the base. Note – An RTK survey needs radio corrections.

3.

If the receiver you are using supports transmission delays and the Prompt for station index check box in the Rover options option in the survey style is selected, the Select base station screen appears. It shows all the base stations operating on the frequency you are using. The list shows the station index numbers of each base and the reliability of each. Highlight the . base you want to use and tap

E

Trimble Survey Controller User Guide

259

Page 284

13

Starting the Rover Receiver

For more information about using transmission delays, see Operating Several Base Stations on One Radio Frequency, page 235.

B

Tip – If you want to check the point name of the base station being used in the rover survey, select Files / Review current job and inspect the Base point record.

4.

Initialize the survey using an RTK initialization method. For more information, see page 264.

5.

Measure points as usual.

Switching to PP infill During periods when no base corrections are received, the following message flashes in the status line: Radio link down

To continue surveying select Start PP infill from the Survey menu. When postprocessing infill starts, this item changes to Stop PP infill. Raw data is logged at the rover during postprocessing (PP) infill. For successful baseline resolution, you must now use postprocessed kinematic observation techniques. Note – Initialization cannot be transferred between the RTK survey and the PP infill survey. Initialize the PP infill survey like any other postprocessed kinematic survey. For more information, see Postprocessed Initialization Methods, page 267. Only rely on the OTF (automatic) initialization if you are certain that the receiver will observe at least five satellites, without interruption, for the next 15 minutes. Otherwise, select Initialization from the Survey menu and perform an initialization. Note – You cannot stake out points during a postprocessed survey.

26 0

Trimble Survey Controller User Guide

Page 285

Starting the Rover Receiver

13

When base corrections are received again, one of the following messages appears in the status line, depending on the initialization mode of the RTK survey: •

Radio link up (RTK=Fixed)

•

Radio link up (RTK=Float)

The first message is displayed if the receiver has retained the RTK initialization during the PP infill survey. That is, if the number of satellites did not fall below four throughout the PP infill survey. Select Stop PP infill from the Survey menu to stop data logging at the rover. When postprocessing infill stops, this item changes back to Start PP infill. Real-time measurements are resumed.

13.5.3

Starting a Postprocessed Rover Survey To start the rover receiver for a postprocessed survey, select Start survey. Note – If using postprocessed techniques, to process the data you must have the Baseline Processing module of the Trimble Geomatics Office software installed. You can begin surveying immediately, you do not need to initialize a FastStatic or differential survey. For more information, see Chapter 16, GPS Point Measurement. You must initialize a PP kinematic survey to achieve centimeter-level precisions when the data is processed. With dual-frequency receivers, the initialization process begins automatically if at least five L1/L2 satellites are being observed. For more information about initializing a postprocessed survey, see Postprocessed Initialization Methods, page 267. For information about measuring points, see Chapter 16, GPS Point Measurement.

Trimble Survey Controller User Guide

261

Page 286

13

Starting the Rover Receiver

Working in Float mode

E I

Work in Float mode if you do not want to initialize a survey. Start the survey and select Initialization. When the Initialization screen . Set the Method field to No initialization and tap appears, press .

13.6

Starting a Wide-Area RTK Survey Wide Area RTK (WA RTK) systems consist of a distributed network of reference stations communicating with a control center to calculate GPS error corrections over a wide area. Real-time correction data is transmitted by radio or cellular modem to the rover receiver within the network area. The system improves reliability and operating range by significantly reducing systematic errors in the reference station data. This lets you increase the distance at which the rover receiver can be located from the physical reference stations, while improving on-the-fly (OTF) initialization times. The Trimble Survey Controller software supports broadcast formats from the following WA RTK solutions: •

SAPOS FKP

•

Virtual Reference Station (VRS)

•

CMRNet

To use a WA RTK system, first check that you have the necessary hardware and firmware.