Trimble Survey Controller User Guide: Starting the Rover Receiver, pages 287 to 294

Pages 287 to 294 of 504, from Trimble Survey Controller User Guide

The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSCe

Page 287

Starting the Rover Receiver 13.6.1

13

Hardware Requirements All rover receivers must have firmware that support WA RTK. For details of availability, check the Trimble website or contact your local dealer. Real-time correction data is provided by radio or cellular modem. For details about the delivery option for your system, contact your local dealer.

13.6.2

Configuring the Survey Style Before you start a survey using a WA RTK system, configure the RTK survey style. To select a WA RTK broadcast format: 1.

In the survey style, select Rover options.

2.

In the Broadcast format field, select one of the following options from the list: –

SAPOS FKP

–

VRS

–

CMRNet

To select a radio solution: 1.

In the survey style, select Rover options.

2.

In the Type field, select your radio from the list. Note – If you are using a radio in a VRS system, you must select a two-way radio. You cannot use Trimble internal radios.

Trimble Survey Controller User Guide

263

Page 288

13

Starting the Rover Receiver

13.6.3

Starting a Rover Survey Starting a rover survey is the same as for a real-time survey. For more information, see page 258. To start a survey using VRS or SAPOS FKP, you must send an approximate position for the rover receiver to the control station. When you start the survey, this position is automatically sent through your radio communications link in a standard NMEA position message. It is used to compute the RTK corrections your receiver will use.

13.7

RTK Initialization Methods If base corrections are being received and there are four or more satellites, the survey is initialized automatically when you start the survey. A survey must be initialized before centimeter-level surveying can begin. Note – At least five L1/L2 satellites are required for OTF initialization. After initialization, at least four satellites must be tracked. If the number of satellites drops below four, the survey must be reinitialized. Table 13.1 summarizes methods of initializing a real-time kinematic survey, and the time required for each method. Table 13.1

Initializing a Real-Time Kinematic survey Time required for each initialization method

Survey and receiver type

Known Point

OTF

Range (km)

RTK

~15 s (5+ SVs)

~60 s, 5+ SVs

<10

Dual-frequency (OTF)

~30 s (4 SVs)

Note – Initialization must be maintained throughout the survey by continuously tracking a minimum of four satellites. If initialization is lost at any time, reinitialize and then continue the survey. 26 4

Trimble Survey Controller User Guide

Page 289

Starting the Rover Receiver

13

After initialization, the survey mode changes from Float to Fixed. The mode remains Fixed if the receiver continuously tracks at least four satellites. If the mode changes to Float, reinitialize the survey. Multipath Initialization reliability depends on the initialization method used and on whether or not multipath occurred during the initialization phase. Multipath occurs when GPS signals are reflected off objects, such as the ground or a building. The occurrence of multipath at the GPS antenna adversely affects GPS initializations and solutions: •

If initialization is by the Known Point method, multipath can cause an initialization attempt to fail.

•

If initialization is by the OTF method, it is difficult to detect the presence of multipath during the initialization. If there is multipath, the receiver may take a long time to initialize or it may not initialize at all. For ore information, see Recommended RTK Initialization Procedure, page 266.

The initialization process in Trimble receivers is very reliable, but if an incorrect initialization does occur, Trimble’s RTK processing routines detect it within 15 minutes (if the mode has remained Fixed). When the error is detected, the receiver automatically discards the initialization and issues a warning. Note – If you survey points with a bad initialization, you will get position errors. To minimize the effect of multipath during an OTF initialization, move around.

13.7.1

Known Point Initialization To perform a Known Point initialization: 1.

Position the rover antenna over a known point.

2.

From the Survey menu, choose Initialization.

Trimble Survey Controller User Guide

265

Page 290

13

Starting the Rover Receiver l

3.

Set the Method field to Known Point.

4.

Access the Point name field and tap the list of known points.

5.

Enter values in the Code and Antenna height fields, and make sure that the setting in the Measured to field is correct.

6.

When the antenna is centered and vertical over the point, tap .

. Select the point from x

The data collector starts to record data, and the static icon ( appears in the status bar.

)

Keep the antenna vertical and stationary while data is recorded. 7.

E

When the receiver is initialized, the following message appears: Initialization change. Initialization has been gained.

The results are displayed. Tap 8.

13.8 z y to accept the initialization.

If the initialization fails, the results are displayed. The Trimble Survey Controller software asks if you want to retry. Tap or .

Recommended RTK Initialization Procedure This section describes the procedure that Trimble recommends for performing a check on an OTF RTK initialization. Minimize the chance of surveying with a bad initialization by adopting good survey techniques. A bad initialization occurs when the integer ambiguities are not correctly resolved. The Trimble Survey Controller software automatically reinitializes when this is detected, but cannot do so if you end the survey too soon. As a precaution, always perform the RTK initialization described below. When initializing, always choose a site that has a clear view of the sky and is free of obstructions that could cause multipath. Note – Known Point is the quickest method of initialization when known points exist.

26 6

Trimble Survey Controller User Guide

Page 291

Starting the Rover Receiver

13

To perform an On-The-Fly initialization: 1.

B

Initialize the survey using the OTF method of initialization.

Tip – When performing an OTF initialization, move around to reduce the effect of multipath.

2.

When the system is initialized, establish a mark about 9 meters (30 feet) from where the initialization occurred.

3.

Conduct a static point measurement over the mark. Once this is done, discard the current initialization.

4.

If you are using an adjustable height range pole, change the height of the antenna by approximately 8 inches.

5.

Reoccupy the mark observed in step 2, and reinitialize the survey using either the OTF or Known Point method of initialization. Remember to enter the new antenna height details.

Follow this procedure to substantially improve the quality of an initialization. Measuring a new point creates a known point on which the first initialization is tested. Changing the antenna height moves the GPS antenna from the environment in which the test point was initially surveyed. Always enter the new antenna height before starting the Known Point initialization.

13.9

Postprocessed Initialization Methods In a postprocessed survey you must initialize to attain centimeter-level precisions. Use one of the following methods to initialize dual-frequency postprocessed kinematic surveys in the field: •

On-The-Fly

•

Known Point Trimble Survey Controller User Guide

267

Page 292

13

Starting the Rover Receiver

Note – In a postprocessed survey, collect enough data during initialization so that the WAVE™ processor can successfully process it. Table 13.2 shows Trimble’s recommended times. Table 13.2

Trimble PP Kinematic initialization times

Initialization method

4 SVs

5 SVs

6+ SVs

L1/L2 OTF initialization

N/A

15 min

8 min

Known Point initialization at least four epochs

After initialization, the survey mode changes from Float to Fixed. The mode remains Fixed if the receiver continuously tracks at least four satellites. If the mode changes to Float, reinitialize the survey. Note – If you do an On-The-Fly initialization in a postprocessed kinematic survey, it is possible to measure points before initialization is gained. The Trimble Geomatics Office software can back-process the data later to give a fixed solution. If you do this but lose lock on the satellites while initializing, re-measure any one of the points that you surveyed before lock was lost.

I

E

To work without initializing the survey (in Float mode), start a survey and select Initialization. When the Initialization screen appears, tap . Set the Method field to No initialization and tap .

13.9.1

Known Point Initialization In a postprocessed survey you can initialize on: • a point measured previously in the current job

• a point that you will provide coordinates for later (before the data is postprocessed)

For instructions on how to do a Known Point initialization, see page 265.

26 8

Trimble Survey Controller User Guide

Page 293

Starting the Rover Receiver

13

Swapping Bases During a Real-Time Rover Survey

13.10

If you are using multiple bases on the same frequency, you can swap bases during the rover survey. For more information, see Operating Several Base Stations on One Radio Frequency, page 235. To swap bases, do the following: •

From the Survey menu, select Swap base receiver. The Select base station screen appears. It shows all the base stations operating on the frequency you are using. The list shows the station index numbers of each base and the reliability of each. Tap the base you want to use.

Note – When you change to a different base, your OTF receiver automatically starts the initialization.

Ending a Rover Survey

13.11

When you have measured or staked out all points required, do the following: 1.

y

From the Survey menu, choose End survey. The Trimble Survey Controller software asks if you want to to confirm this. power down the receiver. Tap

2.

Turn off the TSCe data collector before disconnecting the equipment.

3.

Return to the base station and end the base survey. For more information, see Ending a Base Survey, page 246.

Trimble Survey Controller User Guide

269

Page 294

13

Starting the Rover Receiver

27 0

Trimble Survey Controller User Guide