Page 233

GPS Survey Styles 10.4.7

10

Continuous Points Continuous points use one epoch of data or one real-time measurement to create a point. In a real-time survey, the Trimble Survey Controller software automatically saves continuous points if the horizontal and vertical precisions are satisfied. In a postprocessed survey, it stores continuous points at the time interval specified in the survey style. Set this interval in the Logging interval field of the Rover options screen.

10.4.8

Stakeout To set the as-staked point details: 1.

Select the View before storage check box to view the differences between the design point and the measured as-staked point before storing the result. If you select this check box, enter a value in the Horizontal tolerance field. The Trimble Survey Controller software displays the deltas if the tolerance is exceeded. The default is 0.000. With the default setting, the deltas are always displayed. Note – The Stake delta values are reported as differences from the measured/as-staked point to the design point.

2.

Set the name of the as-staked point to be the next auto point name or a point name that is equivalent to its design name.

3.

Set the code of the as-staked point to be the design point name or the design point code.

To set the display: 1.

Set the Display mode field. The options are: –

Surveyor centered – the cross that represents your current position stays in the center of the screen and the target moves as you change position.

–

Target centered – the target stays in the center of the screen and the cross moves as you change position. Trimble Survey Controller User Guide

209

Page 234

10

GPS Survey Styles

2.

You can enter a value in the Zoom factor field. This is the amount that the display zooms in when you switch from Coarse mode to Fine mode while navigating to a point. The default value is 4.0. When you zoom in by this amount, the width of the graphical display corresponds to approximately one meter (or three feet).

3.

Set the Display grid deltas check box. Do one of the following: –

Select the check box to display the change in northing and easting during stakeout.

–

Clear the check box to display a bearing and distance.

Note – When you stake out a point, the elevation of the current position is also displayed.

10.4.9

Site Calibration To set the parameters for computing a calibration, select the Site calibration survey style option and do the following: 1.

2.

21 0

The Fix H. scale field to 1.0: check box details whether the calibration computation should compute a horizontal scale factor or not: –

To compute the horizontal scale factor, make sure the check box is clear. (This is the default setting.) Use this option only if GPS measurements need to be scaled to fit the local control. (GPS measurements are usually more precise.)

–

To fix the horizontal scale factor to 1.0, select the check box. Select the check box to avoid distorting the geometry of the GPS network, but note that the calibration residuals will be higher.

Select an observation type appropriate to a calibration point. The options for a calibration point are Topo point or Observed control point.

Trimble Survey Controller User Guide

Page 235

GPS Survey Styles

10

3.

For the Trimble Survey Controller software to automatically perform a calibration when you measure a calibration point, select the Auto calibrate check box. To switch automatic calibration off, clear the check box.

4.

If necessary, set the tolerances for maximum horizontal and vertical residuals, and maximum and minimum horizontal scale settings. These settings only apply to automatic calibration and do not affect manual calibration. You can also specify the maximum slope of the vertical adjustment plane. The Trimble Survey Controller software warns you if the slope in the north direction or the slope in the east direction exceeds this. Generally the default settings are appropriate.

5.

Specify how the calibration points you measure will be named: a.

In the Method field, choose one of the following options: Add prefix, Add suffix, or Add constant.

b.

In the Add field, enter the prefix, suffix, or constant.

Table 10.5 shows the different options and gives an example of each. Table 10.5

Calibration point name options

Option

What the software does

Same

Gives the calibration point the same name as the grid point

Add prefix

Example value in the Add field

Grid point name

Calibration point name, 100

100

Inserts a prefix before the grid point name

GPS_

100

GPS_100

Add suffix

Inserts a suffix after the grid point name

_GPS

100

100_GPS

Add constant

Adds a value to the grid point name

10

100

110

Trimble Survey Controller User Guide

211

Page 236

10 10.4.10

GPS Survey Styles

PP Initialization Times Select the PP initialization times survey style option to define initialization times. Generally the default settings are appropriate.

C 10.4.11

Warning – Reducing any of these times can affect the outcome of a postprocessed survey. Increase these times rather than decrease them.

Duplicate Point Actions When you enter the name of a new point, the Trimble Survey Controller software warns if a point of the same name already exists. In a real-time GPS survey, set the tolerances for a duplicate point warning - specify the maximum distance that the new point can be from the existing point. A duplicate point warning appears when you try to store the new point, but only if it is outside the tolerance set. This warning also appears when you key in a duplicate point. If a survey is not running, the tolerances in the last real-time survey are used to perform the check. Specify horizontal and vertical tolerances in the Duplicate point actions screen. The default is 0.000. With the default setting, a warning is always given. To disable the warning, enter high values in the Horizontal and Vertical fields. The range for these settings is 0.000 m to 1000.000 m. Duplicate point: Out of tolerance screen If the new point is “within tolerance” (that is, it has the same name as an existing point and is closer to the existing point than the tolerance specified), the new point is stored.

21 2

Trimble Survey Controller User Guide

Page 237

GPS Survey Styles

10

However, if the new point is “out of tolerance” (that is, it is further from the original point than the tolerance specified), the following screen appears:

In the Action field, choose what to do with the new point, from the following options: •

Discard

•

Rename

•

Overwrite – Overwrite and delete the original point, and all other points of the same name and the same (or lower) search class.

•

Store as check – Store with a lower classification.

•

Store another – Store the point, which can then be averaged in the office software. The original point is used in preference to this point.

•

Store and reorient – Store the point, which is then used as the backsight observation for subsequent measurements.

Similarly, if you enter a duplicate point name, you must choose what to do with the duplicate point. For information about point classification, and how the Trimble Survey Controller software uses search classes, see Database Search Rules, page 423.

Trimble Survey Controller User Guide

213

Page 238

10

10.5

GPS Survey Styles

Differential Survey Styles This section describes the differential survey styles that you can use with the Trimble Survey Controller software, and shows how to create a differential survey style.

10.5.1

Differential Survey Types Differential GPS surveys can be real-time, postprocessed, or a combination of both. For real-time differential surveys, the GPS receiver can track and process signals from the Wide Area Augmentation System (WAAS) instead of using a ground-based RTCM broadcast message. You do not need to use a radio. Note – For WAAS surveys, you must use a receiver that can track WAAS satellites. When using WAAS signals, only Rapid points or postprocessed points can be measured. To conduct a differential survey, first create a survey style that uses a differential survey type. (For more information, see Creating a Differential Survey Style, page 215.) The two differential survey types are described in the following sections:

21 4

•

RT differential – This survey uses the RTCM broadcast message and relies on a reliable radio for the duration of the survey. Alternatively, use WAAS signals to provide real-time positions instead of a radio.

•

RT diff & data logging – This survey works in the same way as an RT differential survey, except that data is recorded for the entire survey both at the base and at the rover receivers. This method is useful if raw data is required for quality assurance purposes.

Trimble Survey Controller User Guide

Page 239

GPS Survey Styles 10.5.2

10

Creating a Differential Survey Style To create a differential survey style:

n

1.

From the main menu select Configuration / Survey Styles.

2.

Tap

3.

Enter a name in the Style name field and tap

4.

In the Style type filed, choose GPS and tap

5.

Choose Rover options or Base options and make the appropriate changes to the Type field. In this case, change it to the differential method that you want to use. The survey type you select depends on whether the technique you choose is real-time or postprocessed.

6.

For both real-time and postprocessed techniques, define an elevation mask and antenna for the base and the rover. For the rover options, define Broadcast format, the PDOP mask, and the RTCM age limit. In a differential survey you can choose to set the Broadcast format field to RTCM or WAAS.

7.

For methods that involve data logging, specify whether the data is to be logged in the receiver or in the Trimble Survey Controller software, and define the interval.

.

E E .

For real-time techniques, the RTCM-SC104 version 2 broadcast message format is used. Real-time signals are generated at 1-second intervals. For more information about options in a survey style, see Creating and Editing a GPS Survey Style, page 198.

Trimble Survey Controller User Guide

215

Page 240

10 10.5.3

GPS Survey Styles

Field Techniques for Differential Surveying Differential surveys require four satellites that are common to the base and the rover receivers. Differential surveys do not require initialization. The success of a real-time differential survey, like that of an RTK survey, depends on the radio solution that you are using. Assuming a trouble-free radio solution, two fixes per second are possible. Note – For postprocessed surveys, always collect enough data at each station.

21 6

Trimble Survey Controller User Guide