Page 375
E
Starting a Conventional Survey
19
The Calculate field indicates what values will be calculated by resection. Tap . The following screen appears:
For more information, see Table 19.1, page 349. 3.
In the Point name field, enter the name of the point you are observing to.
4.
In the Code field, enter a feature code (optional).
5.
Choose an option in the Method field. The options are: –
Angles only – measure the horizontal and vertical angles.
–
Angles and distance – measure the horizontal and vertical angles and slope distance.
m
6.
In the Target height field, enter the height of the target you are observing.
7.
Sight the center of the target and tap
.
Trimble Survey Controller User Guide
351
Page 376
19
Starting a Conventional Survey
The measurement information is displayed on the following screen:
8. 9.
35 2 s 9 y È to accept the If the information is correct, tap observation. To discard the measurement, tap then
È
.
Repeat steps 5 through 8 for all points that you are using in the resection calculation. When there is enough data for the Trimble Survey Controller software to calculate a resected position, the softkey appears. Tap to calculate the resection. The following screen appears:
Trimble Survey Controller User Guide
Page 377
Starting a Conventional Survey
19
Resection results screen Use the Resection results screen to: • • • store the results of the resection add more observations view specific point/observation details
The Resection results screen shows the coordinates of the instrument point as calculated by the resection. It also shows the standard errors for the coordinates. Do one of the following:
A s
.
•
To store the results of the resection immediately, tap
•
To return to the Resection observation screen and observe more . points, tap
•
To view details of the resection, tap appears:
D
. The following screen
W s
To return to the Resection results screen and store the resected point, tap then .
Trimble Survey Controller User Guide
353
Page 378
19
Starting a Conventional Survey
Resection details screen Use the Resection details screen to: • view individual point residuals
• delete observations from the resection
• change which observations are used to compute a solution
A
To return to the Resection observation screen and add more points, tap .
d
To delete an observation from the resection calculation, highlight it . and tap
C
Warning – You cannot include an observation in a resection once the observation is deleted. To see what a solution would be like if you deleted a particular observation, access the Resection point screen, as shown below. In the Use field, select Off.
To return to the Resection results screen, tap
W
.
E
To change which components (horizontal/vertical) of an observation . are used in the resection calculation, highlight the point and tap The following screen appears:
35 4
Trimble Survey Controller User Guide
Page 379
Starting a Conventional Survey
19
Resection point screen The Resection point screen shows the residuals of the observed point. The Use field shows which components of the observation are used in the resection calculation. See Table 19.2. Table 19.2
Use field options
Option
Description
H
Use only the horizontal values for that point in the calculation
V
Use only the vertical values for that point in the calculation
H,V
Use both the horizontal and vertical values for that point in the calculation
Off
Do not use the point in the calculation
Note – If you change the Use field, the resection recomputes when you accept the screen. To store the results of a resection, return to the Resection results screen.
19.3.4
Unknown Instrument Point Coordinates (to be Provided Later), No Known Points to Use as a Backsight If the coordinates of the instrument point (the station) are not known and will be provided later:
J
1.
Enter a value in the Instrument point name field. The Trimble Survey Controller software warns that the point is not in the . Any coordinates measured from this point database. Tap will have null (?) values.
2.
Enter a value in the Instrument height field. Note – For a 2D or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated.
Trimble Survey Controller User Guide
355
Page 380
19
Starting a Conventional Survey
J
3.
Enter a value in the Backsight point name field. The backsight point is not in the database, so the Trimble Survey Controller software asks if you want to key in the point. Tap .
4.
In the Backsight height field, enter the height of the backsight target.
5.
The value in the Azimuth field is null (?).
6.
Choose an option in the Method field. The options are: – Angles and distance – measure horizontal and vertical angles and slope distance – Angles only – measure horizontal and vertical angles – H. Angle only – measure horizontal angle only
7.
Sight the center of the backsight target and tap . The measurement information is displayed on the following screen:
8.
Tap m s to accept the station setup. Station setup is complete.
The instrument point and backsight point can be entered later. Key them in or measure them using GPS. The coordinates of any points measured from that station will then be computed. Note – When you enter the instrument point later, make sure you delete the original instrument point. The coordinates of any points measured from that station will then be computed. Alternatively, provide the coordinates later in the Trimble Geomatics Office or Trimble Survey Office software, after transferring the job.
35 6
Trimble Survey Controller User Guide
Page 381
Starting a Conventional Survey 19.3.5
19
Using the Last Station Setup You can use the last completed station setup if your instrument is still correctly setup and oriented, you are satisfied that the last station setup is still valid, and you want to continue observing points from this station. To use the last station setup, tap
19.4 t in the station setup screen.
Ending a Conventional Survey If a survey is running, end it before editing the current survey style or changing survey styles. You must also end the survey before accessing job functions such as copying. For more information, see Chapter 3, Job Operations. To end a survey, select End survey from the Survey menu. If you are operating a robotic instrument remotely, the instrument can be powered down from the remote end (target) once you select End survey.
Trimble Survey Controller User Guide
357
Page 382
19
Starting a Conventional Survey
35 8
Trimble Survey Controller User Guide