Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 42 of 56

Trimble Survey Controller User Guide: Starting a Conventional Survey, pages 367 to 374

Pages 367 to 374 of 504, from Trimble Survey Controller User Guide

The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSCe

Page 367

CHAPTER

19 19

Starting a Conventional Survey In this chapter: ■

Introduction

■

Connecting to a conventional instrument

■

Station setup

■

Ending a conventional survey

Page 368

19

19.1

Starting a Conventional Survey

Introduction This chapter describes how to start a survey with a conventional instrument. It shows you how to:

19.2

• set up the equipment

• perform a station setup

Connecting to a Conventional Instrument This section shows you how to assemble the equipment to do a survey with a conventional instrument. To assemble the equipment: 1.

Turn on the TSCe data collector.

2.

From the main menu, select Survey.

3.

Select the appropriate survey style.

4.

Connect the TSCe data collector to the instrument.

5.

Turn on the conventional instrument.

6.

Perform a Station Setup. For more information, see, page 345.

Before starting a survey, find the settings for each model of instrument and make sure that they are compatible with the Trimble Survey Controller software. For more information, see Appendix C, Conventional Instrument Settings. Alternatively, contact your local Trimble dealer. If you are operating a robotic instrument remotely, make sure the TSCe data collector is connected to the remote end (target) and that the instrument is configured for remote operation.

34 4

Trimble Survey Controller User Guide

Page 369

Starting a Conventional Survey

19.3

19

Station Setup Before you start work in the field, make sure that the conventional instrument is correctly configured in the survey style that you intend to use, and that the correct job is open. If you intend to combine GPS observations and conventional measurements in the same job, make sure that you define an appropriate coordinate system for the job. For more information, see Choosing a Coordinate System for a Conventional Survey, page 39. Then set up the instrument on a tripod over a point and connect it to the TSCe data collector, as described in Connecting to a Conventional Instrument, page 344. Before measuring points, rounds of observations, or staking out, perform a station setup on the TSCe data collector. To perform a station setup:

E

1.

From the main menu, select Survey. Choose the required survey . style from the list and tap

2.

Select Station setup.

For some instruments, the Trimble Survey Controller software automatically checks to see if various corrections (PPM, prism constant, and curvature and refraction) are being applied correctly. When you select Station setup, messages showing what has or has not been checked are displayed in the status line. If the Trimble Survey Controller software finds that the corrections are being applied twice, a warning message appears. 3.

Follow the instructions in one of the following sections, depending on the information available. This could be: – known coordinates for both the instrument point and the backsight point

– known coordinates for the instrument point, unknown coordinates for the backsight point

Trimble Survey Controller User Guide

345

Page 370

19

Starting a Conventional Survey

– unknown instrument point coordinates, several known points surrounding the instrument point (resection)

– unknown instrument point coordinates (to be provided later), no known points to use as a backsight

Note – If you are using a coordinate system and zone from the Trimble Survey Controller software library, make sure that you use valid coordinates for that zone.

19.3.1

Known Coordinates for Both the Instrument Point and the Backsight Point If the instrument point and the backsight point are already stored in the Trimble Survey Controller database: 1.

In the Instrument point name field, enter the station point name.

2.

Enter a value in the Instrument height field. Note – For a 2D or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated. A project height must be defined before the Trimble Survey Controller can coordinate 2D observations.

3.

Enter a value in the Backsight point name field. The Trimble Survey Controller software calculates the azimuth and inserts it in the Azimuth field, changing the field name to Azimuth (Computed).

4.

In the Backsight height field, enter the height of the backsight target.

5.

Choose an option in the Method field. The options are:

6. 34 6

–

Angles and distance – measure horizontal and vertical angles and slope distance

–

Angles only – measure horizontal and vertical angles

–

H. Angle only – measure horizontal angle only

Sight the center of the backsight target and tap

Trimble Survey Controller User Guide m

.

Page 371

Starting a Conventional Survey

19

The horizontal and vertical distance deltas are the differences between the calculated position and the observed position of the backsight, as shown in the following screen:

7.

19.3.2

Tap s to accept the station setup. Station setup is complete.

Known Coordinates for the Instrument Point, Unknown Coordinates for the Backsight Point If the instrument point is already stored in the Trimble Survey Controller database and the backsight coordinates are unknown: 1.

In the Instrument point name field, enter the station point name.

2.

Enter a value in the Instrument height field. Note – For a 2D or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated.

J

3.

Enter a value in the Backsight point name field. Because the backsight point is not in the database, the Trimble Survey Controller software asks if you want to key in the point. . Tap

4.

In the Backsight height field, enter the height of the backsight target.

5.

In the Azimuth field, enter the azimuth (bearing) from the instrument point to the backsight point.

Trimble Survey Controller User Guide

347

Page 372

19

Starting a Conventional Survey

The Trimble Survey Controller software uses this azimuth to calculate a coordinate for the backsight point. The Azimuth field name changes to Azimuth (Keyed in). Note – If you do not know the azimuth at this stage, you can edit the azimuth record later in Review, or you can measure the backsight point using GPS. The coordinates of any points measured from that station will then be computed. 6.

34 8

Choose an option in the Method field. The options are: –

Angles and distance – measure horizontal and vertical angles and slope distance

–

Angles only – measure horizontal and vertical angles. With this method, no coordinates are calculated for the backsight point. (No coordinates can be obtained if there is no distance.)

–

H. Angle only - measure horizontal angle only m

7.

. The Sight the center of the backsight target and tap measurement information is displayed on the following screen but no deltas are displayed because there are no known coordinates for the backsight:

8.

Tap s to accept the station setup. Station setup is complete.

Trimble Survey Controller User Guide

Page 373

Starting a Conventional Survey 19.3.3

19

Unknown Instrument Point Coordinates, Several Known Points Surrounding the Instrument Point (Resection) Use a resection calculation to compute coordinates for the instrument point by making observations to known points during the station setup process. Note – In a resection, only use points that can be viewed as grid coordinates. (The resection calculation is a grid calculation.) A resection needs a minimum of the following: •

Three sets of angles

•

Two observations with horizontal and vertical angles and slope distances

The Trimble Survey Controller software uses a least-squares algorithm to compute the resection. This uses all of the data collected and gives a statistically better result. When doing a resection, make sure that the geometry of the observations will produce a stable result. In a two-point resection, the result can be unreliable if the angle between the instrument point and the two resection points is close to 180°. In a three-point resection, the result can be unreliable if the three points and the instrument point lie on a circle. For all resections, results are unreliable if the points you are observing are close together. Table 19.1 shows the different types of resection provided by the Trimble Survey Controller software. Table 19.1

Values computed by resection

Known coordinate values for instrument point

Values computed by resection

Northing, Easting, Elevation

Northing, Easting, Elevation

Northing, Easting

Elevation

Elevation

Northing, Easting

None

Northing, Easting, Elevation

Trimble Survey Controller User Guide

349

Page 374

19

Starting a Conventional Survey

To do a resection: 1.

r kr J

In the Instrument point name field, enter the station point name. The Trimble Survey Controller software warns that the point is , , and softkeys not in the database, and the appear. Tap . The following screen appears:

2.

In the Instrument height field, do one of the following: –

For a 2D resection, leave the field value as null (?).

–

For a 3D resection, enter a value. If you entered a value in this field in the Station Setup screen, the Trimble Survey Controller software automatically transfers that value to this screen.

Note – Once the resection is started you cannot enter a different instrument height.

35 0

Trimble Survey Controller User Guide