The text of a manual · part 41 of 56
Trimble Survey Controller User Guide: Conventional Instrument Survey Styles
Pages 353 to 366 of 504, from Trimble Survey Controller User Guide
The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSCe
Page 353
CHAPTER
18 18
Conventional Instrument Survey Styles In this chapter: ■
Introduction
■
Conventional survey styles
■
Creating and editing a conventional survey style
Page 354
18
18.1
Conventional Instrument Survey Styles
Introduction This chapter shows you how to create and configure a conventional survey style. When you use the Trimble Survey Controller software for a conventional survey, choose a conventional survey style that is specific to the type of instrument used, and your measurement preferences.
18.2
Conventional Survey Styles Use a survey style to change the configuration of the Trimble Survey Controller software quickly and easily for different types of survey. Each survey style contains a set of information specific to your equipment and preferences. The information is stored as a pattern or template that you can call up and re-use when necessary. To survey using the Trimble Survey Controller software and a conventional instrument, select a conventional survey style. A conventional survey style defines the parameters for configuring and communicating with your instruments and for measuring and storing points. The Trimble Survey Controller software provides default conventional, robotic, and servo survey styles for use with Trimble conventional instruments. To use any other type of instrument, modify these survey styles or create a new conventional survey style.
33 0
Trimble Survey Controller User Guide
Page 355
Conventional Instrument Survey Styles
18.3
18
Creating and Editing a Conventional Survey Style To create a conventional survey style:
n
1.
From the main menu, choose Configuration / Survey styles. The . Survey Styles screen appears. Tap
2.
Enter a name in the Style name field.
3.
to accept In the Style type field, select Conventional. Tap the screen. A screen with options relevant to the chosen style type appears.
4.
Select each item in turn and specify your equipment and preferences in the screens that appear. For information about each menu item, see the following sections.
E
To edit a conventional survey style: 1. 2. 3.
From the main menu, select Configuration / Survey Styles. The list of survey styles appears.
f
Highlight the name of the survey style to be edited and tap .
Change each option as required. For information about each menu item, see the following sections.
For more information on configuring a conventional survey style and your conventional instrument, see Appendix C, Conventional Instrument Settings. Select Instrument to specify the type of instrument used and its communication parameters. Instrument Type The Trimble Survey Controller software interfaces with different brands of conventional instrument. Access the Manufacturer and Model (optional) fields to display a list of these names and then select the instrument you are using. The default communications parameters for the instrument appear. Change them if necessary. There is also a manual entry mode that lets you key in observations. Trimble Survey Controller User Guide
331
Page 356
18
Conventional Instrument Survey Styles
Communication Settings Use the Baud rate field to configure the Trimble Survey Controller baud rate to match that of the conventional instrument. Use the Parity field to configure the Trimble Survey Controller parity to match that of the conventional instrument. When you change the instrument type, the baud rate and parity settings automatically change to the default settings for the selected instrument. HA VA status rate Use the HA VA status rate field to set how often the Trimble Survey Controller software updates the horizontal and vertical angle display in the status line with information from the conventional instrument. Note – Some instruments beep when communicating with the Trimble Survey Controller software. You can turn off the beep in the instrument or set the HA VA status rate to Never. EDM Precision The EDM precision field appears if the instrument type specified has more than one measuring mode that can be set by the Trimble Survey Controller software. Use it to specify how the EDM measures distances. The options vary according to the option that you selected in the Type field. Select the Instr. default option to always use the setting on the instrument. Set backsight The Set backsight field appears if you can set the horizontal circle reading on the instrument when the backsight is observed. The options are No, Zero, and Azimuth. If you select the Azimuth option, when you observe the backsight the horizontal circle reading is set to the computed azimuth between the instrument point and the backsight point.
33 2
Trimble Survey Controller User Guide
Page 357
Conventional Instrument Survey Styles
18
Stakeout auto turn When the instrument type is a servo or robotic instrument, the Stakeout auto turn check box and the Servo options field appears. Select the check box if you want the Trimble Survey Controller software to operate the servos automatically during stakeout when you are measuring a known (coordinated) point. Use the Servo options field specify which servos are used - choose from HA only, or HA & VA. Instrument precisions Use the Instrument precision fields to record the precisions of the instrument. Do one of the following: •
Leave them as null.
•
Enter the manufacturer’s values.
•
Enter your own values based on your observing techniques.
If you enter values, they are used by the Trimble Geomatics Office software to compute the standard error statistics for an observation. If you leave the fields as null, the Trimble Geomatics Office default values are used to compute the standard error statistics.
18.3.1
Target Select Target to enter information about the target in use. Use the Prism constant field to specify the distance offset for each prism. When the prism constant is to be subtracted from measured distances, enter a negative value. For some instruments, the Trimble Survey Controller software checks to see if a prism constant has been applied by the instrument and the Trimble Survey Controller software. When you select Station setup, messages are displayed in the status line showing what has or has not been checked.
Trimble Survey Controller User Guide
333
Page 358
18
Conventional Instrument Survey Styles
If the Trimble Survey Controller software cannot check the setting on the conventional instrument, do one of the following: •
If there is a prism constant set on the instrument, make sure that the prism constant in the Trimble Survey Controller software is set to 0.000.
•
If there is a prism constant set in the Trimble Survey Controller software, make sure that the prism constant in the instrument is set to 0.000.
Use the Height field to specify a target height. This is the distance from the point you are measuring to the center of the target.
18.3.2
Laser Rangefinder Select Laser Rangefinder to set the parameters for using a laser rangefinder with a conventional instrument. For more information about configuring a laser, see Chapter 23, Laser Observations.
33 4
Trimble Survey Controller User Guide
Page 359
Conventional Instrument Survey Styles 18.3.3
18
Topo point Select Topo point to set the parameters for observing topographic points. Use the Measure display field to define how the observations are displayed on the TSCe data collector. See Table 18.1.
Table 18.1
Measure display options
Option
Corrections applied
Description
HA VA SD (raw)
None
Observation as seen on the conventional instrument display
HA VA SD
Prism constant
Raw observation corrected for prism constant
HA HD VD
Prism constant Pressure and temperature Instrument height and Target height Curvature and refraction
HA and HD from Station ground point to Target ground point and the height difference (VD) between these points
Az VA SD
Prism constant Pressure and temperature Orientation Curvature and refraction
Raw observation corrected for prism constant, orientation, and atmospheric effects.
Az HD VD
Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction
Same as HA HD VD but with backsight orientation applied to the HA
∆ Grid
Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction Polar to rectangular
Trigonomical calculation of the ∆ NEE relative to the instrument The same information as AZ HD VD but presented as rectangular coordinates
Trimble Survey Controller User Guide
335
Page 360
18
Conventional Instrument Survey Styles
Table 18.1
Measure display options (Continued)
Option
Corrections applied
Description
Grid
Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction Polar to rectangular conversion Full coordinate transformation
Reduced grid coordinates
Use the Auto point step size field to set the increment size for automatic point numbering. The default is 1, but you can use larger step sizes and negative steps. Select the View before storage check box to view observations before they are stored.
18.3.4
Rounds Select Round to specify the settings for measuring multiple sets (rounds) of observations. Use the Number of rounds field to specify the number of rounds of observations that the Trimble Survey Controller software prompts for. Use the Observation order field to specify the order in which the Trimble Survey Controller software prompts for observations in the rounds survey. Select Measure distance on face 2 to measure the distances on face 2 observations.
33 6
Trimble Survey Controller User Guide
Page 361
Conventional Instrument Survey Styles 18.3.5
18
Corrections Select Corrections to set the corrections associated with conventional observations.
C
Warning – Check the conventional instrument to make sure that corrections are not being applied by both the instrument and the Trimble Survey Controller software.
Use the PPM field to specify a parts per million correction. This correction applies a scale factor to the electronic distance measurement based on environmental conditions. Manually key in the PPM correction, or enter the pressure and temperature of the surrounding environment and let the Trimble Survey Controller software compute it. Use the Curvature and refraction field to specify the index of refraction value. This is used to compute the curvature and refraction correction that is applied to vertical angle observations. See Table 18.2. Table 18.2
Curvature and refraction options
Option
Description
0.142 for use during the day
0.2 for use at night
None no correction applied
For some instruments, the Trimble Survey Controller software automatically checks to see if various corrections (PPM, prism constant, and curvature and refraction) are being applied correctly. If it finds that the corrections are being applied twice, a warning message appears. Note – If you intend to perform a network adjustment in the Trimble Geomatics Office software using data from a conventional survey, make sure that you enter a pressure, temperature and, curvature and refraction correction. Trimble Survey Controller User Guide
337
Page 362
18 18.3.6
Conventional Instrument Survey Styles
Stakeout To configure the as-staked point details: 1.
Select the View before storage check box. This lets you view the difference between a design point and the measured as-staked point before storing the point.
2.
Enter a value in the Horizontal tolerance field. The Trimble Survey Controller software displays the deltas if this tolerance is exceeded. The default is 0.000 (deltas always displayed).
3.
Specify the name of the as-staked point to be the next auto point name or a point name that is equivalent to its design name.
4.
Specify the code of the as-staked point to be the design point name or the design point code.
5.
To display the as-staked deltas as grid (Northing, Easting, Elevation) values, select the Display grid deltas check box.
The stakeout graphical display screen displays directions using the conventional instrument as a reference point. To configure the display: 1.
Choose a setting in the Deltas field. The options are: –
Angle and distance – navigate to a point using angle and distance
–
Distances – navigate to a point using distances only
For a comparison of these options, see the stakeout screens shown on page 382.
33 8
2.
Use the Distance tolerance field to specify the allowable error in distance. If the target is within this distance from the point, the graphical stakeout display indicates that the distance(s) is correct.
3.
Use the Angle tolerance field to specify the allowable error in angle. If the conventional instrument is turned away from the point by less than this angle, the graphical stakeout display indicates that the angle is correct.
Trimble Survey Controller User Guide
Page 363
Conventional Instrument Survey Styles
4.
18.3.7
18
If you define a DTM and select the Display cut/fill to DTM check box, the graphical display screen displays cut or fill relative to that DTM. Use the DTM field to specify the name of the DTM to be used.
Duplicate point actions In a conventional survey, you can set the tolerances for a duplicate point warning. If you are measuring a point using the Angles and distance, H. Angle offset or Single dist. offset method, you can specify the maximum horizontal and vertical distance that the new point can be from the existing point. Do one of the following: •
If you are measuring a point using the Angles only or H. angle only method, you can specify the maximum horizontal and vertical angle that the new observation can be from the existing observation.
•
If you are measuring a coordinated point, the Trimble Survey Controller software will compare the observed angle with the computed angle between the instrument point and the observed point.
•
If you are measuring a point that is not coordinated, the Trimble Survey Controller software will compare face 1 observations with the first face 1 observation.
When you try to store a new point, and the duplicate point is outside the tolerance you set, a duplicate point warning appears. For more information, see Duplicate Point Actions, page 212. Note – In a conventional survey, when you enter a point name that already exists, the message Point already exists does not appear. This is because you may want to regularly measure points on both faces.
Trimble Survey Controller User Guide
339
Page 364
18
Conventional Instrument Survey Styles
When you use a conventional instrument to measure points on two faces, the Trimble Survey Controller software behaves according to the settings in the Duplicate point actions screen. For example: If you make a face 1 observation to a point and then store a face 2 observation to the same point (with the same point name), the Trimble Survey Controller software performs a duplicate observation tolerance check between the two observations, based on the F1/F2 observation tolerance settings: •
If the face 1 and face 2 observations are within tolerance, they are averaged. A matched pair record is stored immediately after the face 2 observation. Furthermore, a mean turned angle record is stored after the matched pair. For more information about matched pairs and mean turned angles see, Measuring a Point in Two Faces, page 364.
•
If the face 1 and face 2 observations are out of tolerance, the Observation: Out of tolerance screen appears. The options are: –
Discard – discard the observation without storing.
–
Rename – rename to a different point name.
–
Store as check – store with a classification of Check.
–
Store another – store the observation and the matched pair.
–
Store and reorient – (This option only appears if you are observing a backsight point.) Store another observation that will provide a new orientation for subsequent points measured in the current station setup. Previous observations are not changed. Use this if you are doing multiple rounds of observations.
Note – If the target height changed between the face 1 and face 2 observations, the Trimble Survey Controller software reduces the face 1 and face 2 observations to HA HD VD, and produces a matched pair that is the mean HA HD VD.
34 0
Trimble Survey Controller User Guide
Page 365
Conventional Instrument Survey Styles
18
When you make the next observation to the same point, the Trimble Survey Controller software performs a duplicate point tolerance check using the best point in the database and the point just measured: •
If it is within tolerance, the new observation is stored.
•
If it is out of tolerance, the Duplicate point: Out of tolerance screen appears. For more information, see, Duplicate point: Out of tolerance screen, page 212.
18.3.8
Traverse options Use these options to specify how a traverse calculation is adjusted. See Table 18.3.
Table 18.3
Traverse adjustment options
Field
Option
What it does
Adjustment method
Compass
Adjusts the traverse by distributing the errors in proportion to the distance between traverse points
Transit
Adjusts the traverse by distributing the errors in proportion to the northing and easting ordinates of the traverse points
Error distribution Angular
Elevation
Proportional to distance
Distributes the angular error among the angles in the traverse based on the sum of the inverses of the distances between traverse points
Equal proportions
Distributes the angular error evenly among the angles in the traverse
None
Does not distribute the angular error
Proportional to distance
Distributes the elevation error in proportion to the distance between traverse points
Equal proportions
Distributes the elevation error evenly among the traverse points
None
Does not distribute the elevation error
Trimble Survey Controller User Guide
341
Page 366
18
Conventional Instrument Survey Styles
Note – The Compass option is the same as the Bowditch method of adjustment. For information about calculating and adjusting a traverse, see Traverses, page 177.
34 2
Trimble Survey Controller User Guide