Page 263
w w
Starting the Base Receiver
6.
Disconnect the power from the radio and tap The following message appears:
w
Please confirm. Connect power to radio.
7.
Reconnect the power to the radio and tap need to tap for a Pacific Crest radio.)
12
.
. (There is no
The second Base radio/Rover radio screen appears. 8.
Change the settings in the Frequency field and the Base radio mode field, as required.
EE
The radio firmware version is also displayed. 9.
Tap when the details are correct. (There is no need to tap for a Pacific Crest radio.)
Note – In some countries it is illegal to change the frequency of a radio. The Trimble Survey Controller software uses the latest GPS position to see if you are in one of these countries. If you are, only the available frequencies are displayed in the Frequency field.
12.4
Setting Up the Equipment for a Postprocessed Survey This section shows how to assemble the hardware components at the base receiver for a postprocessed kinematic, a postprocessed differential or a FastStatic survey. Follow these steps when using a GPS Total Station 5700, 4800, or 4700 receiver.
12.4.1
Using a GPS Total Station 5700 Receiver To set up the base receiver for a postprocessed survey using a GPS Total Station 5700 receiver, see Figure 12.2. Then do the following:
Trimble Survey Controller User Guide
239
Page 264
12
Starting the Base Receiver
1.
Set the Zephyr antenna over the ground mark using a tripod, a tribrach, and a tribrach adaptor.
2.
Use the tripod clip (Part Number 43961) to hang the 5700 receiver on the tripod.
3.
Connect the Zephyr antenna to the yellow GPS receiver port labeled GPS. Use the yellow GPS antenna cable (part number 41300-10).
Note – Instead of hanging the receiver on the tripod, you can place the receiver in its base case. Run the antenna cable out of the portal in the side of the base case to the antenna so that the case can stay closed while the receiver is running.
C
12.4.2
Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.
4.
If external power is required, connect the power supply with a 0-shell Lemo connection to Port 2 or Port 3 on the receiver.
5.
Connect the TSCe data collector to the GPS receiver port 1. Use the 0-shell Lemo to 0-shell Lemo cable.
6.
Turn on the TSCe data collector, then follow the instructions in Starting a Base Survey, page 242.
Using a GPS Total Station 4800 Receiver To set up the base receiver hardware for a postprocessed survey using a GPS Total Station 4800 receiver, see Figure 12.3. Then do the following:
24 0
1.
Set the GPS receiver over the ground mark using a tripod, a tribrach, and a tribrach adaptor.
2.
Connect the power supply to the GPS receiver port 2 and turn on the receiver.
Trimble Survey Controller User Guide
Page 265
Starting the Base Receiver
C
12.4.3
12
Warning – Do not force plugs into the receiver ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.
3.
Connect the TSCe data collector to the GPS receiver port 1.
4.
Turn on the TSCe data collector, then follow the instructions in Starting a Base Survey, page 242.
Using a GPS Total Station 4700 Receiver To set up a base receiver for a postprocessed survey using a Trimble GPS Total Station 4700 receiver, see Figure 12.4. Then do the following:
C
1.
Set the GPS antenna over the ground mark using a tripod, a tribrach, and a tribrach adaptor. If one of the GPS antennas has a ground plane, use this as the base antenna. For more information, see Measuring the Height of an Antenna When Using a Ground Plane, page 221.
2.
Connect the GPS antenna to the GPS receiver port labeled “GPS ANTENNA”. Use the N-type to Lemo co-axial cable.
Warning – Do not force plugs into the receiver ports. Check the number of pins in the plug to make sure that the socket is compatible. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.
3.
Connect the power supply to the GPS receiver port 2 and turn on the receiver.
4.
Connect the TSCe data collector to the GPS receiver port 1. Use the 0-shell Lemo to 0-shell Lemo cable.
5.
Turn on the TSCe data collector, then follow the instructions in Starting a Base Survey, page 242.
Trimble Survey Controller User Guide
241
Page 266
12
12.5
Starting the Base Receiver
Setting Up the Equipment for a Real-Time and Postprocessed Survey To conduct a survey that uses both real-time and postprocessed techniques, follow the assembly instructions for real-time surveys. If the receiver has no memory (or has a limited memory), use a TSCe data collector to store raw data at the base receiver.
12.6
Starting a Base Survey To conduct a survey using a predefined survey style, make sure that the required job is open. The title of the main menu should be the current job name. From the main menu, choose Survey and select a survey style from the list. To create or edit a survey style, see Creating and Editing a GPS Survey Style, page 198. A Survey menu is generated. It displays items specific to the chosen survey style and includes the Start base receiver and Start survey items.
C
Warning – In a real-time survey, make sure that the radio antenna is connected to the radio before starting the base survey. If it is not, the radio will be damaged.
To start a base survey: 1.
24 2
From the Survey menu, choose Start base receiver. –
If the TSCe data collector is connected to a receiver that was logging data, the data logging is stopped.
–
The first time that you use this survey style, the Style wizard prompts you to specify the equipment you are using. For more information, see The Style wizard, page 197.
Trimble Survey Controller User Guide
Page 267
Starting the Base Receiver
12
The Start base screen appears. Note – When you start a survey, the Trimble Survey Controller software automatically negotiates the highest possible baud rate for communicating with the connected receiver. 2.
Enter the base station name and coordinates. For more information, see Base Station Coordinates, page 224. Use one of the following methods.: – k
If WGS-84 coordinates are known:
Access the Point name field and enter the point name. Tap .
o
In the Key in point screen, set the Method field to Keyed in coordinates. Check that the coordinate fields are Latitude, Longitude, and Height (WGS-84). If they are not, tap and change the Coordinate view setting to WGS-84. Key in the known WGS-84 coordinates for the base station, and tap . – s k
If grid coordinates are known, and projection and datum transformation parameters are defined: Access the Point name field and enter the point name. Tap .
o s
In the Key in point screen, set the Method field to Keyed in coordinates. Check that the coordinate fields are Northing, and change Easting, Elevation. If they are not, tap the Coordinate view setting to Grid. Key in the known grid coordinates for the base station, then tap . –
If local geodetic coordinates are known and a datum transformation is defined:
k
Access the Point name field and enter the point name. Tap .
Trimble Survey Controller User Guide
243
Page 268
12
Starting the Base Receiver o
In the Key in point screen, set the Method field to Keyed in coordinates. Check that the coordinate fields are Latitude, Longitude, and Height (Local). If not, press and change the Coordinate view setting to Local. Key in the known local coordinates for the base station, then tap .
s
In a real-time survey, select either the current WAAS position, or the current autonomous position, derived by the GPS receiver.
k
) s
Then, access the Point name field and enter the point name. Tap to access the Key in point screen. Tap and the current position is displayed. Tap to accept and store this position.
)
Note – If you want a WAAS position, ensure the receiver is tracking a WAAS satellite by checking the WAAS icon is . The receiver displayed on the status line when you tap can take 120 seconds to lock on to WAAS. Alternatively, check the Observation class field before starting the base.
C
Warning – Within a job, only use an autonomous position (the softkey) to start the first base receiver.
3.
4. 5. 6.
)
Note – If you carry out a real-time survey using RTCM corrections and use a base point name that is more than eight characters long, the name will be shortened to eight characters when it is broadcast. The Observation class field shows the observation class of the base point. For more information, see Observation class, page 303. Enter values in the Code (optional) and Antenna height fields. Set the Measured to field as appropriate. In the Station index field, enter a value. This value is broadcast in the correction message, and must be in the range 0-29.
24 4
Trimble Survey Controller User Guide
Page 269
B
Starting the Base Receiver
Ü
12
Tip – Tap to view a list of other base stations operating on the frequency you are using. The list shows the station index numbers of the other bases and the reliability of each. Choose a different station index number to those displayed.
7.
If the receiver you are using supports transmission delays, the Transmission delay field appears. Choose a value depending on how many base stations you intend to use. For more information about transmission delays, see Operating Several Base Stations on One Radio Frequency, page 235.
8.
Tap x
.
The base receiver starts to record data. 9.
Do one of the following: –
If you are carrying out a real-time survey or are logging data in the receiver, the following message appears: Base started Disconnect controller from receiver
Disconnect the TSCe data collector from the base receiver but do not turn off the receiver. You can now set up the rover receiver. Note – For a real-time survey, check that the radio is working before leaving the equipment. The data light should be flashing. –
If you are logging data in the TSCe data collector, the Base screen appears. It shows which point is being surveyed and the time that has elapsed since data logging started. Leave the TSCe data collector connected to the base receiver and set up the rover using another TSCe data collector.
Trimble Survey Controller User Guide
245
Page 270
12
12.7
Starting the Base Receiver
Ending a Base Survey After an RTK survey, or after logging data in the receiver, end the survey as follows: 1.
y
2.
Turn off the TSCe data collector.
3.
Disconnect the equipment.
Return to the equipment and select Survey / End survey. Tap to confirm that you want to end the survey, and again to power down the receiver.
e
After logging base station data in the TSCe data collector, end the survey as follows:
24 6 y
.
1.
Return to the equipment and tap
2.
to confirm that you want to end the survey, and again Tap to power down the receiver.
3.
Turn off the TSCe data collector.
4.
Disconnect the equipment.
Trimble Survey Controller User Guide