The text of a manual · part 52 of 56
Trimble Survey Controller User Guide: Conventional Instrument Settings
Pages 455 to 464 of 504, from Trimble Survey Controller User Guide
The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSCe
Page 455
APPENDIX
C C
Conventional Instrument Settings In this chapter: ■
Introduction
■
Trimble and Geodimeter
■
Leica
■
Sokkia
■
Nikon
■
Pentax
■
Additional notes
Page 456
C
C.1
Conventional Instrument Settings
Introduction This appendix lists the settings for different conventional instruments. The Trimble Survey Controller software supports the instruments listed and other instruments that are compatible.
C.1.1
Trimble and Geodimeter •
Before you connect the TSCe data collector to older Geodimeter instruments, select an appropriate survey style, which must specify the correct type of instrument. Connect the instrument and select Station setup. Failure to follow this procedure may result in communication errors. If this occurs, turn the instrument off and try again. This does not apply to robotic instruments connected remotely through a radio modem.
•
To use the Trimble Survey Controller software with a Geodimeter 600 instrument in robotic mode, you must have the third-party interface option (C&C) turned on in the instrument. All Trimble 5600 and Geodimeter 600 instruments shipped since November 2000 have the option already installed. To get the option installed, or if you are unsure if the option is installed in your instrument, please check with your local distributor or service center.
•
43 2 m
When you measure a point using a Geodimeter 420 instrument, press A/M on the instrument then in the Trimble Survey Controller software.
Trimble Survey Controller User Guide
Page 457
Conventional Instrument Settings
C
Robotic instrument radio support To configure the radio settings for a Trimble 5600 Series and a Geodimeter System 600 Robotic instrument from the Trimble Survey Controller software: 1.
Configure the Radio channel, Station address and Remote address fields as required in the Instrument menu of your survey style.
2.
Remove the CU600 control unit from the instrument, connect the TSCe data collector, and turn the instrument on.
3.
Tap the r softkey to set the radio at the instrument.
When you connect the TSCe data collector to the remote radio, the Trimble Survey Controller software establishes the radio link between the instrument and remote radio using the specified settings.
C.1.2
Leica •
Before you connect the TSCe data collector to a Leica instrument, select an appropriate survey style, which must specify the correct type of instrument. Connect the instrument and select Station setup. Failure to follow this procedure may result in communication errors. If this occurs, turn the instrument off and try again. This does not apply to robotic instruments connected remotely through a radio modem.
•
When using a Leica instrument in reflectorless mode, set the EDM precision to Instr. default in the survey style.
Trimble Survey Controller User Guide
433
Page 458
C C.1.3
C.1.4
C.1.5
Conventional Instrument Settings
Sokkia •
The Stakeout turn to zero check box appears when the instrument type is SET (Extended). Select this check box if you want the horizontal angle on the instrument to display 0° 00' 00'' when the instrument is turned on line with the point in stakeout.
•
The Nikon cable looks identical to the Topcon and Sokkia cables, but the pin outputs are different. These cables are not interchangeable.
•
Most Nikon instruments support the Set (Basic) commands, so in addition to using the Nikon instrument type you can also specify Set (Basic) as the instrument in the survey style for use with Nikon instruments.
Nikon
Pentax •
C.1.6
43 4
Do not use the Mils, or Feet/inches units when using a Pentax instrument.
Additional Notes •
The conventional instrument should always display the Measure screen when connected to the Trimble Survey Controller software. Some instruments (for example, the Leica) cannot communicate to external devices when they are not in the measure screen.
•
The Trimble Survey Controller software automatically sets the data bits based on the parity. When the parity is None, Data bits is set to 8. When the parity is Odd or Even, Data bits is set to 7.
Trimble Survey Controller User Guide
Page 459
Conventional Instrument Settings
C
For additional information on using a conventional instrument with the Trimble Survey Controller software, see the Trimble Survey Controller Release Notes. If you are using an instrument that is not listed, try using the survey style for a similar instrument, and configure the appropriate settings on the instrument, as shown in Table C.1. Table C.1
Conventional instrument settings
Make and model
Trimble Survey Cable connected Controller default to TSCe communication settings
Conventional instrument setting
Trimble 3300 3600
600M
Baud: 9600 Parity: None HA VA status rate: 1 s
Baud: 1200 Parity: None HA VA status rate: Never
TTS 300/500
Baud: 9600 Parity: None HA VA Status Rate: 2 s
Set F79 to 62.
Hirose Y-cable with power supply to 0shell Lemo Hirose to DB9
Baud: 9600 Parity: None HA VA Status Rate: 1 s
The Rec Elta Protocol Interpreter software is required on the instrument. Select the Standard table (table number 0).
Hirose to 0-shell Lemo (Trimble p/n 44147)
5600 Servo
5600 Robotic
8P connector to DB9
Set the protocol to REC E and turn off recording.
0-shell Lemo to 0-shell Lemo (Trimble p/n 31288)
Select the Standard table (table number 0). Select RPU Manual or Automatic.
Select the Standard table (table number 0). Select RPU Remote.
No special settings.
Trimble Survey Controller User Guide
435
Page 460
C
Conventional Instrument Settings
Table C.1
Conventional instrument settings (Continued)
Make and model
Trimble Survey Cable connected Controller default to TSCe communication settings
Conventional instrument setting
Leica Baud: 19200 Parity: Even HA VA status rate: 2 s
TC300 TC500
Baud: 2400 Parity: Even HA VA status rate: 2 s
TC800
No special settings.
TC805 T1000 (6 key model)
Baud: 2400 Parity: Even HA VA status rate: Never Leica 5-pin Lemo to DB9
T1000 (14 key model) TC1100 TC1100 Servo (GSI) TC1100 Servo (Geocom) TC1100 Robotics (Geocom)
Baud: 2400 Parity: Even HA VA status rate: 2 s
Set the RCS communications mode to off. Ensure that the instrument is in Measurement mode.
Baud: 9600 Parity: Even HA VA status rate: 2 s
Baud: 19200 Parity: None HA VA status rate: 2 s
Leica Y-Cable with power supply to DB9
TC1600 TC2000
Set the RCS communications mode to on. Ensure that the instrument is in Measurement mode.
No special settings. Baud: 2400 Parity: Even HA VA status rate: 2 s
Leica 5-pin Lemo to DB9
TC2002
43 6
Set the instrument communications format to T1000 and output to GRE.
Trimble Survey Controller User Guide
On the instrument, select SET MODE, then 75. No special settings.
Page 461
Conventional Instrument Settings Table C.1
Conventional instrument settings (Continued)
Make and model
Trimble Survey Cable connected Controller default to TSCe communication settings
C
Conventional instrument setting
Nikon DTM-310 DTM-420 DTM-450 DTM-520
Baud: 1200 Parity: None HA VA status rate: 2 s
Hirose to DB9
No special settings.
DTM-530 DTM-800
Baud: 1200
Use Instrument type Set (Basic). The DTM-800 does not support the Nikon format.
Parity: None HA VA status rate: Never Pentax PCS-325
Baud: 1200 Parity: None HA VA status rate: 1 s
Hirose to DB9
Configure the port parameters as follows: Xon/Xoff: No Command set: Nil
Sokkia SET 3B SET 3C II SET 5W SET 5F
Baud: 1200 Parity: None HA VA status rate: Never
Hirose to DB9
When using Set (Extended) select RS232C on the SET and set the Checksum to No. No special settings required using SET (Basic).
Power set 3100
Trimble Survey Controller User Guide
437
Page 462
C
Conventional Instrument Settings
Table C.1
Conventional instrument settings (Continued)
Make and model
Trimble Survey Cable connected Controller default to TSCe communication settings
Conventional instrument setting
Spectra Precision (Geotronics) 420
Baud: 1200 Parity: Even HA VA status rate: Never
520
Baud: 1200 Parity: None HA VA status rate: Never
610 620 640 500/600 Servo
Baud: 9600 Parity: None HA VA Status Rate: 2 s
Select the Standard table (table number 0). Hirose to 0-shell Set F79 to 62. Lemo (Trimble P/N 44147) Hirose Y-cable with power supply to 0shell Lemo Hirose to DB9
600 Robotics 4000 Servo Baud: 9600 Parity: None HA VA Status Rate: Never
43 8
Geotronics DB9 Y-cable with power supply to DB9
Geotronics DB9 Y-cable with power supply to DB9
Trimble Survey Controller User Guide
Select the Standard table (table number 0). Select RPU Manual or Automatic. Select the Standard table (table number 0). Select RPU Remote. Select the Standard table (table number 0). Set F79 to 62.
Page 463
Conventional Instrument Settings Table C.1
Conventional instrument settings (Continued)
Make and model
Trimble Survey Cable connected Controller default to TSCe communication settings
C
Conventional instrument setting
Topcon GTS-700 GTS-701 No special settings.
GTS-711D GTS-500 GMT-100
Baud: 1200
Hirose to DB9
Parity: Even HA VA status rate: Never GTS-311
Select Parameters / Comms and set the CR/LF option to OFF. Turn off the minimum distance setting. Select Parameters / Comms and set the CR/LF option to OFF.
GTS-312 GTS-211D
No special settings. Zeiss
Elta 2
Baud: 1200
Elta 3
Parity: Odd HA VA status rate: Never
No special settings. Zeiss 5P connector to DB9
Elta 4
Do not use Mils as the angular units.
Rec Elta 15 Baud: 4800 Parity: Odd HA VA status rate: 1 s Elta C
Baud: 9600 Parity: None HA VA status rate: 1 s
R Series
Baud: 9600 Parity: None HA VA status rate: 1 s
S Series
Not supported
Set data record format to Rec 500. Zeiss 8P connector to DB9
The Rec Elta Protocol Interpreter software is required on the instrument. Set the protocol to REC E and turn off recording.
Trimble Survey Controller User Guide
439
Page 464
C
44 0
Conventional Instrument Settings
Trimble Survey Controller User Guide