Page 317
CHAPTER
16 16
GPS Point Measurement In this chapter: ■
Introduction
■
Measuring a topo point in a GPS survey
■
Measuring a FastStatic point
■
Measuring an observed control point
■
Measuring a Rapid point
■
Measuring continuous topo points
■
Measuring an as-staked point
■
Measuring a laser point
■
Measuring a calibration point
■
Measuring a check point
■
Next free point name search
■
Storing Points
Page 318
16
16.1
GPS Point Measurement
Introduction In a GPS survey, you measure points by choosing one of several predefined point types. The survey style (and so the survey type) you choose determines the type of point(s) that can be measured. A single survey style cannot measure every kind of point, so it is necessary to use different survey styles to measure different kinds of point. For example, an RTK survey style can be used to measure observed control points, Rapid points, topo points, and calibration points, but to measure a FastStatic point, you must use a FastStatic survey style. For more information, see Chapter 10, GPS Survey Styles. This chapter shows you how to change some survey options, how to measure different types of point, and also explains the quality control records that are stored when you measure a point using GPS. Note – For RTK surveys, initialize the survey before measuring points.
16.2
Measuring a Topo Point in a GPS Survey You can measure a topo point in every type of survey except a FastStatic survey. To measure a topo point: 1.
29 4
Do one of the following:
G
–
From the main menu, select Survey / Measure points.
–
Tap and select Measure points.
2.
Enter values in the Point name and Code fields (the Code field entry is optional), and select Topo point in the Type field.
3.
Enter a value in the Antenna height field and make sure that the setting in the Measured to field is set appropriately.
4.
to start When the antenna is vertical and stationary, tap recording data. The static icon appears in the status bar.
Trimble Survey Controller User Guide m
Page 319
5.
B 16.3
GPS Point Measurement s
16
When the preset occupation time and precisions have been reached, tap to store the point.
Tip – In the survey style, select the Auto store point check box to automatically store the point when the preset occupation time and precisions have been met.
Measuring a FastStatic Point You can only measure a FastStatic point in a FastStatic survey. Note – FastStatic surveys are postprocessed and do not need to be initialized. To measure a FastStatic point: 1.
Do one of the following:
G
–
From the main menu, select Survey / Measure points.
–
Tap and select Measure points.
2.
Enter values in the Point name and Code fields (the Code field entry is optional).
3.
Enter a value in the Antenna height field and make sure that the setting in the Measured to field is set appropriately.
4.
Tap
5.
When the preset occupation time is reached, as shown in to store the point. Table 16.1, tap
Table 16.1 m s to start measuring the point.
Trimble FastStatic occupation times
Receiver type
4 SVs
5 SVs
6+ SVs
Single-frequency
30 min
25 min
20 min
Dual-frequency
20 min
15 min
8 min
Trimble Survey Controller User Guide
295
Page 320
16
GPS Point Measurement
Tip – No satellite tracking is necessary between measuring points. You can turn off the equipment.
16.4
Measuring an Observed Control Point When the Trimble Survey Controller software measures an observed control point, it stores a point when the preset number of epochs has elapsed and the precisions have been attained. To measure an observed control point: 1.
Do one of the following:
G
–
From the main menu, select Survey / Measure points.
–
Tap and select Measure points.
2.
Enter values in the Point name and Code fields (the Code field entry is optional), and select Observed control point in the Type field.
3.
Enter a value in the Antenna height field and make sure that the setting in the Measured to field is set appropriately.
4.
Tap
5.
When the preset number of epochs and precisions are reached, to store the point. tap m s to start recording data.
Note – For an RTK survey, initialize the survey before starting to measure the point. For a Postprocessed Kinematic survey, you can start measuring a point, but you cannot store it until you have initialized the survey.
29 6
Trimble Survey Controller User Guide
Page 321
GPS Point Measurement
16.5
16
Measuring a Rapid Point A Rapid point is stored when the preset precisions are attained. There is no minimum occupation time, and point storage is automatic. To measure a Rapid point: 1.
Do one of the following:
G
–
From the main menu, select Survey / Measure points.
–
Tap and select Measure points.
2.
Enter values in the Point name and Code fields (the Code field entry is optional), and enter Rapid point in the Type field.
3.
Enter a value in the Antenna height field and make sure that the setting in the Measured to field is set appropriately.
4.
to start recording data. The point is automatically Tap stored when the preset precisions are reached.
m
Note – When using WAAS positions in a survey, the only type of point you can store is a Rapid point.
16.6
Measuring Continuous Topo Points Continuous topo points are stored automatically and continuously after a preset time and/or distance, and once the required precisions are reached. In a real-time survey, the Trimble Survey Controller software can measure a line of continuous offset points at the same time as a line of continuous topo points. To measure a line of continuous topo points: 1.
From the main menu, select Survey / Continuous topo.
2.
In the Type field, select Fixed distance continuous, Fixed time continuous, or Time & distance continuous.
Trimble Survey Controller User Guide
297
Page 322
16
GPS Point Measurement
Note – For a postprocessed survey, you can only use the Fixed time continuous method. The time interval is set by default to the same value as the logging interval. 3.
Enter a value in the Antenna height field and make sure that the setting in the Measured to field is set appropriately.
4.
Enter a value in the Horizontal distance field and/or the Time interval field, depending on the method you are using.
5.
Do one of the following: –
If you are measuring Fixed distance or Time & distance continuous points, select None in the Offset field.
–
If you are measuring Fixed distance or Time & distance continuous offset points, select One or Two (the second line of offset points) in the Offset field.
6.
Enter a value in the Start point name field (or enter a start point name for the center line when measuring offset points). This increments automatically.
7.
If you are measuring an offset line, enter the offset distances and the start point name. To enter a left horizontal offset, enter a or . negative offset distance or use the
8.
to start recording data, and then move along the Tap feature to be surveyed.
m
ÔR e
Note – To change the distance interval, time interval, or offset while measuring points, enter new values in the fields. 9.
16.7
To stop measuring continuous points, tap
.
Measuring an As-Staked Point You can only measure an as-staked point when performing stakeout operations in a real-time GPS survey or a conventional survey. In a GPS survey, a point is staked out then measured. For more information, see Chapter 17, GPS Stakeout.
29 8
Trimble Survey Controller User Guide
Page 323
GPS Point Measurement
16.8
16
Measuring a Laser Point Use a laser rangefinder to measure a laser point. For more information, see Chapter 23, Laser Observations.
16.9
Measuring a Calibration Point In a real-time survey, you measure calibration points. Generally, a point in the database has keyed-in grid coordinates and you measure it as a calibration point using GPS. When you store the calibration point, the Trimble Survey Controller software does one of the following, according to the Auto calibrate option that you selected in the survey style: •
If the Auto calibrate check box is selected, the software immediately performs an automatic calibration using all calibration points that have been surveyed.
•
If the Auto calibrate check box is not selected, the point is added to the calibration and the Site calibration screen is displayed.
For more information, see Using GPS to Measure Calibration Points, page 279. Note – In the Site calibration option in the survey style, calibration points are configured to be measured with the same settings as topo points or observed control points. However, with calibration points, softkey lets you navigate to the next calibration point, and the the Auto calibrate setting described above can be used.
f
Trimble Survey Controller User Guide
299
Page 324
16
GPS Point Measurement
Measuring a Check Point
16.10
In a GPS survey, measure a point twice. Give the second point the same name as the first point. If the duplicate point tolerances are set to zero, the Trimble Survey Controller software warns that the point is a duplicate when you try to store it. Select Store as check to store the second point as a check class point. For more information, see Duplicate Point Actions, page 212.
f
Next Free Point Name Search
16.11
In Point name fields there is a next available point name.
softkey that lets you search for the
For example, if your job contains points numbered in the 1000s, 2000s and 3000s, and you want to find the next available point name after 1000:
f E
. The Find next free point name
1.
In the Point name field, tap screen appears.
2.
Enter the point name you want to start searching from (in this . example, 1000) and tap
The Trimble Survey Controller software searches for the next available point name after 1000 and inserts it in the Point name field.
30 0
Trimble Survey Controller User Guide
Page 325
GPS Point Measurement
16
Storing Points
16.12
How you record a point determines how it is stored in the Trimble Survey Controller software. Points are stored either as vectors or as positions. For example, RTK points and conventionally observed points are stored as vectors, while keyed-in points, real-time differential points, and postprocessed points are stored as positions. From the main menu, select Files / Review current job. A point record contains information about the point such as the point name, the code, the method, the coordinates, or the GPS data file name. The Method field describes how the point was created. The coordinates are expressed as WGS-84, local, or grid coordinates, depending on the setting in the Coordinate view field. To change a Coordinate view setting, do one of the following:
o
•
Select Configuration / Job / Units
•
Select Files / Review current job, access the point record, and . tap
Note – Define a datum transformation and/or a projection if you want to display local or grid coordinates for a GPS point. Alternatively, calibrate the job. Each point record uses the antenna height given in the previous antenna height record. From this, the Trimble Survey Controller software generates a ground height (elevation) for the point. Table 16.2 shows how the point is stored in the Stored as field. Table 16.2
Point storage
Value
What the point is stored as
Grid
Grid coordinates
Local
Local geodetic coordinates
WGS-84
WGS-84 geodetic coordinates
ECEF
WGS-84 Earth-Centered-Earth-Fixed X, Y, Z coordinates
Trimble Survey Controller User Guide
301
Page 326
16
GPS Point Measurement Table 16.2
Point storage (Continued)
Value
What the point is stored as
ECEF deltas
WGS-84 Earth-Centered-Earth-Fixed X, Y, Z vector
Polar
Azimuth, horizontal distance, and vertical distance. This is a vector.
HA VA SD
A horizontal circle reading, vertical circle reading (a zenith angle), and slope distance. This is a vector.
HA VA SD (raw)
A horizontal circle reading, vertical circle reading (a zenith angle), and slope distance with no corrections applied. This is a vector.
Mag.Az VA SD
A magnetic azimuth, vertical (zenith) angle, and slope distance vector.
MHA MVA MSD
A meaned horizontal angle from the backsight, meaned vertical angle (a zenith angle), and meaned slope distance. This is a vector.
MHA MHD MVD
A meaned horizontal angle from the backsight, meaned horizontal distance, and meaned vertical distance. This is a vector.
Read the Stored as field in conjunction with the Method field. Note – Points stored as vectors are updated if the calibration or coordinate system of the job changes, or the antenna height of one of the source points is changed. Points stored as WGS-84 coordinates (for example, an offset point calculated using the From a baseline method) are not updated. For GPS points, Quality Control (QC) records are stored at the end of the point record.
30 2
Trimble Survey Controller User Guide
Page 327
GPS Point Measurement 16.12.1
16
Point Classification When points are stored they have either one or two classifications: •
Points that have been measured using GPS have an observation class and a search class.
•
Points that have been keyed in, computed, or measured with a conventional instrument or laser rangefinder have only a search class.
Observation class For real-time surveys, the observation class is L1 Fixed, L1 Float, WA Fixed, WA Float, or L1 Code, and precisions are recorded. For postprocessed surveys, the observation class is autonomous and no precisions are recorded. Table 16.3 lists the observation classes and resulting solutions. Table 16.3
Observation classes
Observation class
Result
L1 Fixed
An L1 fixed real-time kinematic solution.
L1 Float
An L1 float real-time kinematic solution.
L1 Code
An L1 code real-time differential solution.
Autonomous
A postprocessed solution.
WAAS
A position that has been differentially corrected using WAAS signals.
WA Fixed
A fixed solution using Wide Area processing.
WA Float
A float solution using Wide Area processing.
Trimble Survey Controller User Guide
303
Page 328
16
GPS Point Measurement
Search class A search class is applied to a point when it is measured, keyed in, or computed. The search class is used by the Trimble Survey Controller software when details of a point are required for stakeout or calculations (for example, for Cogo calculations). When you select a point name, the database is searched from the start down. The first search is for a control class point. If no point is found, the next search is for a normal class point, then an as-staked point, then a backsight class point. If still no point is found, the final search is for a check class point. Table 16.4 describes the different search classes. Table 16.4
Search classes
Search class
Description
Control
The highest order of search class. A control class point can only be overwritten by another control class point. Key in or upload control points. Points that are adjusted in a traverse are stored as control points.
Normal
Most points are usually measured as normal class. A normal class point can only be overwritten by another normal class point later in the database, or by a control class point.
30 4
As-staked
If a point was staked out and then measured, it has an as-staked classification.
Backsight
If a point was observed as a backsight or a resection target in a conventional survey, it has a backsight classification.
Trimble Survey Controller User Guide
Page 329
GPS Point Measurement
16
Table 16.4
Search classes (Continued)
Search class
Description
Check
Check class is the lowest order of search class that will be found by the Trimble Survey Controller software search rules. Check class points can be overwritten by any class of point except deleted points. A check point can only be measured; it cannot be keyed in.
Deleted
When points are deleted in the Trimble Survey Controller software, the original class is given the prefix Deleted. Deleted class points are not displayed in lists, used in calculations, or found by database searches.
Note – Measured points have a search class of normal or lower. For more information, see Appendix B, Database Search Rules.
Trimble Survey Controller User Guide
305
Page 330
16
GPS Point Measurement
30 6