Page 91

CHAPTER

4 4

Data Transfer In this chapter: ■

Introduction

■

Data transfer between the TSCe data collector and the office computer

■

Data transfer between the Trimble Survey Controller software and another device

Page 92

4

Data Transfer

4.1

Introduction This chapter describes how to transfer data between the TSCe data collector and an office computer. It lists the types of files that can be transferred, and shows how to connect the equipment for transfer. It then shows how to transfer point names, point codes, and grid coordinates in ASCII format between the TSCe data collector and a variety of conventional instruments, data collectors, and office computers.

4.2

Data Transfer between the TSCe Data Collector and the Office Computer You can transfer various types of files between the TSCe data collector and the office computer, including data collector (.dc) files, feature code files, digital terrain models (DTM), and language files. The data transfer process on the data collector is controlled by the office computer software when you connect the data collector to the office computer and select the appropriate options. You can transfer files using: •

The Trimble Data Transfer utility

•

The Trimble Data Transfer utility with Microsoft ActiveSync software enabled

•

Microsoft Explorer with the Microsoft ActiveSync software enabled

You can also transfer data to and from the TSCe data collector using other Trimble software packages. For more information, refer to the help provided with the Trimble office software. Note – To transfer ASCII data between the TSCe data collector and other devices, see Data Transfer between the Trimble Survey Controller Software and Another Device, page 72.

68

Trimble Survey Controller User Guide

Page 93

Data Transfer 4.2.1

4

Using the Trimble Data Transfer Utility Use the Trimble Data Transfer utility to transfer files between the Trimble Survey Controller software and the office computer. For more information on using Trimble’s Data Transfer utility, see the Trimble Data Transfer Help and the Trimble Survey Controller Release Notes.

4.2.2

Using the Trimble Data Transfer Utility with the Microsoft ActiveSync Software Enabled To transfer files between the Trimble Survey Controller software and the office computer: 1.

Make sure that the TSCe data collector and office computer are switched on. Disconnect any devices that are communicating with the data collector, and close down any applications to ensure that the communications ports are available.

2.

3.

Connect the TSCe data collector to the office computer. Use one of the following methods: –

Serial cable

–

USB cable

–

Infrared

–

Network (Ethernet) card.

y

The Microsoft ActiveSync icon on your Windows taskbar will start spinning and the TSCe data collector will prompt you with . the message, Connect to desktop. Tap

Trimble Survey Controller User Guide

69

Page 94

4

Data Transfer

4.

If the message does not appear on the TSCe data collector and the Microsoft ActiveSync icon does not spin, there is a connection problem. Check that the connection settings in the Microsoft ActiveSync software are correct and that there are no applications using the COM port on the TSCe data collector. If necessary, perform a soft reset (warm boot). For more information, see Rebooting, page 416. Note – Always connect the TSCe data collector to the Microsoft ActiveSync software with the Guest connection. Partnership connections between the data collector and your office computer are not supported. For more information about Guest connections, see the Microsoft ActiveSync Help.

5.

On the office computer, start the Data Transfer utility. The rest of the procedure is controlled by this software.

Note – To transfer files to and from earlier versions of the Trimble Survey Controller software or Trimble GPS receivers, turn off the Microsoft ActiveSync software and use the Trimble Data Transfer utility directly.

4.2.3

Using Microsoft Explorer with the Microsoft ActiveSync Software Enabled You can use Microsoft’s Explorer and ActiveSync software to move or copy files to or from the TSCe data collector. Use the software to transfer files that do not require conversion by the Data Transfer utility (for example, comma delimited (.csv) files). See Table 4.1. From the Microsoft ActiveSync window: 1.

Click Explore to move or copy files between the office computer and the TSCe data collector for sharing information. Alternatively, use Windows Explorer to move or copy files.

2.

Click Tools to backup and restore files.

For more information on using Microsoft ActiveSync software to transfer files, refer to the Microsoft ActiveSync Help.

70

Trimble Survey Controller User Guide

Page 95

Data Transfer

4

File Conversion When data is transferred to and from the Trimble Survey Controller software, some files are converted for use in the Trimble software. Table 4.1 lists the files that are used in the Trimble Survey Controller software and the file types they are converted to when transferred to and from Trimble office software. Table 4.1

Trimble Survey Controller files

PC

TSCe

Description

Trimble Microsoft Data Explorer Transfer using ActiveSync

.dc

.job

Survey Controller job files

Y

N

.csv

.csv

Comma Delimited (CSV) files

Y

Y

.dtx

.dtm

Digital Terrain Model files

Y

N

.ttm

.ttm

Triangulated Terrain Model files

Y

Y

.fcl

.fal

Feature and Attribute Library files

Y

N

.ddf

.fal

Data Dictionary files

Y

N

.ggf

.ggf

Geoid Grid files

Y

Y

.cdg

.cdg

Combined Datum Grid files

Y

Y

.pgf

.pgf

UK National Grid files

Y

Y

.dxf

.dxf

Background Map files

Y

Y

.ini

.dat

Antenna files

Y

N

.lng

.lng

Language files

Y

Y

.wav

.wav

Sound files

Y

Y

.dat

.dat

GPS data files

Y

Y

Trimble Survey Controller User Guide

71

Page 96

4

Data Transfer

When a .dc file is transferred to the Trimble Geomatics Office software, any GPS data files associated with that file are also transferred. Information about the .dc file format is available from the Trimble website (www.trimble.com). For more information, contact your local Trimble dealer. Note – If a Trimble Geomatics Office project uses a geoid model, remember to also transfer the geoid file (or the subgridded part of it) when transferring the job into the Trimble Survey Controller software. AutoCAD Land Development Desktop software Use the Trimble Link™ software to transfer data between the Trimble Survey Controller software and Autodesk’s AutoCAD Land Development Desktop software. When job data is transferred from the Trimble Survey Controller software to the AutoCAD Land Development Desktop software, a .tic file is created.

4.3

Data Transfer between the Trimble Survey Controller Software and Another Device This section shows you how to use the ASCII data transfer function in the Trimble Survey Controller software. Use this function to transfer point names, point codes, and grid coordinates in ASCII format between the TSCe data collector and a variety of conventional instruments, data collectors, and office computers. In addition, you can transfer ASCII files directly to the office computer using third-party download software, such as HyperTerminal. Note – Only points with grid coordinates are transferred when you use the ASCII data transfer function. If the job does not have a projection and datum transformation specified, GPS points cannot be transferred. Furthermore, deleted points, and any points stored as polar vectors from a deleted point, cannot be transferred.

72

Trimble Survey Controller User Guide

Page 97

Data Transfer 4.3.1

4

Transferring ASCII Data to and from an External Device You can transfer ASCII data to and from an external device or office computer in the following formats: •

Geodimeter® (Area)

•

Comma delimited (*.csv)

•

SDR33 coordinates

•

SDR33 DC

•

SC Exchange

•

TDS

•

Topcon (GTS-7)

•

Topcon (FC-5)

•

Trimble DC v10.0

•

Zeiss (R5)

•

Zeiss (Rec E/M5)

•

Zeiss (Rec500)

In an SC Exchange .dc file, all observations are reduced to WGS-84 positions and grid positions (coordinates). Use this file format to transfer .dc files between different versions of the Trimble Survey Controller software running on the TSCe and TSC1 data collectors. The next sections describe how to connect the TSCe data collector, and how to send and receive data to and from the Trimble Survey Controller software.

Trimble Survey Controller User Guide

73

Page 98

4

Data Transfer

Sending ASCII Data to an external device

C

Warning – When sending data to a device that does not include a units setting as part of its file, make sure that the Trimble Survey Controller file uses the units setting of that device. If you are not sure whether the device file includes a units setting, set the Trimble Survey Controller file to the same units as the device.

To send ASCII data to an external device: 1.

Select the files to transfer: a.

Select Files / Import/Export / Send ASCII data. The following screen appears:

b.

Use the File format field to specify the type of file that you want to send. If the File format field is set to Comma Delimited (*.CSV), SC Exchange or SDR33 DC, the Send to field appears. Set the field to External device.

74

Trimble Survey Controller User Guide

Page 99

Data Transfer

2.

4

Set the transfer parameters: a.

Set the Controller port field to the TSCe data collector port you are using for the transfer.

b.

Set the Baud rate and Parity fields to match the corresponding parameters on the device that you are communicating with. Note – If the File format field is set to Comma Delimited (*.CSV), set the baud rate correctly on the external device. If appropriate, also set the flow control (xon/xoff).

c.

If you are transferring a .dc file, and you want the Trimble Survey Controller software to include a checksum when the file is transferred, select On in the Checksum field. Note – For the Geodimeter (Area), SDR33, TDS, Topcon (GTS-7), Topcon (FC-5), Zeiss (R5), Zeiss (Rec E/M5), and Zeiss (Rec500) output options, the format is controlled by the external device.

3.

Set the file parameters: a.

If the File format field is set to SDR33 coordinates or TDS, the Job name field appears. Enter a name for the file that is created when the data is transferred.

b.

Set the Point name field to Unchanged or Auto-generate. Unchanged sends the point names as they appear on the TSCe data collector. Auto-generate adds two extra fields: – Use the Start point name field to specify the name of the first point to be transferred. – Use the Auto point step size field to define the amount by which the Start point value is incremented or decremented when the Trimble Survey Controller software generates point names for subsequently transferred points.

Trimble Survey Controller User Guide

75

Page 100

4

Data Transfer

Note – If the File format field is set to TDS and the Point name field is set to Unchanged, a point will only be transferred if the point name is less than eight characters long and contains numeric characters only. c.

Use the Point code field to specify what is sent to the external device selected in the Code field: – Select Use point code to send the point code. – Select Use point name to send the point name. Note – If you have used long codes (up to 42 characters) in the Trimble Survey Controller software, and the file format you are transferring to does not support long codes, the codes will be shortened.

4.

76 d.

If the File format field is set to SDR33 coordinates, there is an Output notes check box. Select this to output all userentered notes with the point data. The notes are output in SDR33 record 13NM format.

e.

If the File format field is set to Comma Delimited (*.CSV), you can specify the format of the data to be output. Five fields appear: Point name, Point code, Northing, Easting, and Elevation. Using the options provided, select a position for each field. Select Unused if you do not want to send a particular value. For example: Point name

Field 1

Point code

Unused

Northing

Field 3

Easting

Field 2

Elevation

Field 4

Transfer the files:

=

.

a.

When the format details are complete, tap b.

If you are sending points (not a .dc file), the Select points screen appears. Select the points to send.

Trimble Survey Controller User Guide

Page 101

Data Transfer

4

The procedure is similar to that used to create a Stake out points list. For more information, see Points, page 311. c.

The Trimble Survey Controller software prompts you to initiate receiving on the instrument that you are sending data to. For more information about receiving data, refer to the manual for the receiving device. When the other device is ready to receive, tap the data. The data is transferred.

y to send

Receiving ASCII Data from an External Device

C

Warning – When receiving data from a device that does not include a units setting as part of its file, make sure that the Trimble Survey Controller file uses the units setting of that device. If you are not sure whether the device file includes a units setting, set the Trimble Survey Controller file to the same units as the device.

To receive ASCII data from an external device: 1.

Select the files to send: a.

Select Files / Import/Export / Receive ASCII data. The following screen appears:

Trimble Survey Controller User Guide

77

Page 102

4

Data Transfer b.

In the File format field, specify the device that you want to receive data from. If the File format field is set to Comma Delimited (*.CSV), SC Exchange, or SDR33 DC, the Receive from field appears. Set this field to External device.

2.

Set the transfer parameters: a.

In the Port details/Controller port field, select the TSCe data collector port used for the transfer.

b.

Set the Baud rate and Parity fields to match the corresponding parameters on the device that the Trimble Survey Controller software is communicating with. Note – If the File format field is set to Comma Delimited (*.CSV), set the baud rate correctly on the external device. If appropriate, also set the flow control (xon/xoff).

c.

3.

If you are transferring a .dc file, and you want the Trimble Survey Controller software to validate the checksum when the file is transferred, select On in the Checksum field.

The option in the File format field determines what you do next: –

If one of the following options is selected, the format is controlled by the external device: Geodimeter (Area) SDR33 TDS Topcon (GTS-7) Topcon (FC-5) Zeiss (R5) Zeiss (Rec E/M5) Zeiss (Rec500) Use the Point name field to define how the point names in the data are received.

78

Trimble Survey Controller User Guide

Page 103

Data Transfer

4

Note – Trimble Survey Controller point names have a maximum of 16 characters, but some points received from other devices can exceed this. If point names have 16 characters or more, choose either Truncate left or Truncate right. –

If the Comma Delimited (*.CSV) option is selected, you can specify the format of the data that is received. Five fields appear: Point name, Point code, Northing, Easting, and Elevation. Using the options provided, select a position for each field. Select Unused if a particular value is not present in the file being received. For example:

4.

Point name

Field 1

Point code

Unused

Northing

Field 2

Easting

Field 3

Elevation

Field 4

Store the files:

_

.

a.

When the format details are complete, tap b.

The Trimble Survey Controller software prompts you to initiate sending on the external device. For more information about sending data, refer to the manual for the sending device. When sending is initiated, the Trimble Survey Controller software starts to receive data, and a progress bar appears. When the transfer is complete, the Trimble Survey Controller software automatically terminates the operation and saves the received data.

Trimble Survey Controller User Guide

79

Page 104

4

Data Transfer c.

9

If it is clear that the transfer is complete but the operation has not been terminated, tap . The following message appears: Transmission interrupted. What would you like to do now?

J | C

Do one of the following:

80

– to return the Trimble Survey Controller software Tap to receive mode.

– to terminate the operation and save any received Tap data to the current job.

– to terminate the operation and discard any Tap received data.

Trimble Survey Controller User Guide