The text of a manual · part 5 of 56
Trimble Survey Controller User Guide: General Operation, pages 33 to 40
Pages 33 to 40 of 504, from Trimble Survey Controller User Guide
The original document is the PDF (5.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSCe
Page 33
General Operation 1.3.5
E m
E
Enter button
1
=
The button performs the same action as pressing on the TSCe keypad. The action of the button relates to particular screens, and in some screens, the caption on the button changes to describe the action for that screen. For example, changes to when you are in the Measure points screen.
1.3.6
E
Softkeys Softkeys (software keys) are displayed on the bottom line of the Trimble Survey Controller screen. Softkeys relate to particular screens and only appear when these screens are accessed. For example, the softkey appears when the Antenna height field is accessed, as it relates to this field.
U
N
Tap a softkey to access it, or use the shortcut key combinations with a designated key from the keypad. For example, in the Map of current or the key combination, job screen, to zoom in on an area, tap + .
C/ ~
Note – The # softkey appears if there are more than four softkeys associated with a screen. Tap it to see the others. Alternatively, press the (Shift) key to access the other softkeys.
1.3.7
Shortcut keys Shortcut keys (also known as access keys or hotkeys) provide a quick way of using the keypad to access menus and commonly used options. They appear as an underlined letter in the menu or option description. Hold down the key and press the appropriate letter key to use them.
A
Trimble Survey Controller User Guide
9
Page 34
1
General Operation
Table 1.2 shows the shortcut keys that are commonly used in the Trimble Survey Controller software.
A
Table 1.2 Use
Survey Controller shortcut keys f k s c o i m e a w h plus this key...
to access the... Files menu Key in menu Survey menu Cogo menu Configuration menu Instrument menu Map of current job Main menu Favorites menu Switch to list Online Help
For information on the shortcut keys you can use to carry out commands in the TSCe data collector and Windows CE, see Appendix A, page 412.
10
Trimble Survey Controller User Guide
Page 35
General Operation 1.3.8
1
Online Help Online help for the Trimble Survey Controller software is displayed in Hyper-text Markup Language (HTML) pages. You can click on any underlined text (link) to move to the page it describes. There are several ways to obtain help while you are using the Trimble Survey Controller software: •
4
Ah
To access help within the Trimble Survey Controller software, + . tap or press An index of all the topics appears, with the default topic for the current screen highlighted. Do one of the following:
1.4
–
To view this topic, tap the topic.
–
To search for a different topic, enter a new keyword or scroll through the list.
Entering Data To enter data: 1.
When a field is highlighted, tap the field again to access it. Then do one of the following: –
Type the numeric or alphanumeric details, depending on the field.
–
Select an item from a list of options. To do this, highlight . the required option and tap
–
Select an item from a list of relevant records in the database. To see the list of available records, tap then select the required item(s) and tap . (The softkey only appears when you edit certain fields.)
–
E
E ll ,
Select an item from the map. For more information, see Selecting Features, page 51.
Trimble Survey Controller User Guide
11
Page 36
1
General Operation
–
1.4.1
U
To enter a value in different units, type in the value and tap . Select the units to be used. The value is converted to the system units and the result is inserted in the field. For more information, see System Units, page 58.
E E to save any changes and
2.
When the field is complete, tap move to the next field.
3.
When all fields are complete, tap to accept the screen. Some screens cannot be accepted unless certain fields have been completed. For example, in the Measure points screen, you cannot measure a point unless the Point name and Antenna height fields have values in them. If you tap before completing these fields, a warning message appears.
E
Using Quadrant Bearings To enter quadrant bearings: 1.
Make sure the system units are quadrant bearings. For more information, see System Units, page 58
2.
Enter the bearing in any Bearing field.
3.
Tap
367 8 ,
,
, or
.
The quadrant bearing is inserted in the field. Example To enter the quadrant bearing N25° 30' 30"E in a bearing field:
12
3
•
Key in 25.3030 .
•
Tap
.
Trimble Survey Controller User Guide
Page 37
General Operation
1
Using the In-Field Calculator
1.4.2
The TSCe in-field calculator lets you calculate values for the following fields: •
Northing
•
Easting
•
Elevation
•
Antenna height
•
Azimuth
•
Dist
•
H.Dist
•
V.Dist
Ë softkey appears, When you access one of these fields, the indicating that the calculator is available. Use the calculator to find values such as the total of two distances, or the distance between two points.
B
Tip – When calculating a distance between two points, tap the points from the Trimble Survey Controller database.
l l to select
Note – When keying in a point name that includes spaces, put double quotes around it. To save time, use the softkey to select the point. Table 1.3 shows the operators for the in-field calculator. Table 1.3
Symbols used by the in-field calculator
Symbol
Function
=
Example
Result
Starting an equation
=3+4
7
+
Adding
=3+2+5
10
-
Subtracting
=5-3
2
*
Multiplying
=2*4
8
Trimble Survey Controller User Guide
13
Page 38
1
General Operation
Table 1.3
Symbols used by the in-field calculator (Continued)
Symbol
Function
Example
Result
/
Dividing
=10/2
5
(
Inserting parentheses
=2*(5+3)
16
) Calculating the azimuth between two points
=1000
1001
Azimuth between Point 1000 and Point 1001 Note: The arrow symbol only appears in the list for an azimuth field.
Calculating the slope distance between two points
=1000
1001
Slope distance between Point 1000 and Point 1001
Calculating the horizontal distance between two points
=1000
1001
Horizontal distance between Point 1000 and Point 1001
Calculating the vertical distance between two points
=1000
1001
Vertical distance between Point 1000 and Point 1001 Note: The triangle symbols only appear in the list for a distance field.
B 1.4.3
Tip – When you enter equations using the in-field calculator, enter the “=” symbol first.
Time/date options To find out how to set the time and date on the TSCe data collector, see Appendix A, page 415. To specify other time and date options in the Trimble Survey Controller job, select Configuration / Controller / Time/date and do the following: •
14
Set the fixed interval after which the Trimble Survey Controller software automatically records the current time in the current job. Enter the required interval in the Time stamp field.
Trimble Survey Controller User Guide
Page 39
General Operation
•
1.5
1
Set the GPS time display to Local date/time if you want to display the GPS time (for example, in the QC records) as a local date and time instead of GPS weeks and seconds. The values are always stored as GPS weeks and seconds - this setting only configures the display.
Reviewing the Database To view the records stored in the job database, do one of the following:
G
•
From the main menu, select Files / Review current job.
•
Tap and select Review current job.
Records are stored in chronological order. To move around the database, use one of the following:
p P æ ( E n v 9 •
The scroll bar.
•
The
•
The arrow keys.
and softkeys.
To search for a particular item: •
Tap
, and select an option to search for.
To move to the end of the database quickly: •
Highlight the first record then press on the keypad.
For more information about a record, highlight the record and tap . The and softkeys show the next record and the previous record respectively. Tap to return to the database listing. Note – If point coordinates appear as “?” see Coordinate View Setting, page 16. You can edit certain records, for example, Code and Antenna.
Trimble Survey Controller User Guide
15
Page 40
1
General Operation
Note – When you change an antenna height record in the database, any offset points that are stored as coordinates are not updated. Also, the change in antenna height does not affect any postprocessed points that will be processed using the Trimble Geomatics Office™ software. Verify the antenna height information when you transfer the data to the office computer. Do the same if you transfer postprocessed points directly from the receiver to the office software.
B
Tip – To review features from the Map of current job screen, select the required feature(s), tap and hold on the screen and choose Review from the shortcut menu.
You can store a note at any position in the database. To do this:
Ú E
1.
Highlight a record.
2.
Tap
3.
. The note is stored immediately Enter the note and tap before the record you highlighted in step 1.
E
. The Note screen appears.
9
The Note screen remains open until you tap tap when there is no text on the screen.
. Alternatively,
For details of the road information that is stored in a job, see Chapter 6, Roading.
1.5.1
Coordinate View Setting The setting in the Coordinate view field (for example, WGS-84, Local, Grid, or HA VA SD) determines which values are visible in the point record. You can change the coordinate view setting for the job or just for viewing a point. To change the coordinate view setting for the job, see System Units, page 58.
16
Trimble Survey Controller User Guide