Allen-Bradley user manual for the DS/DD Series B enhanced bar code decoders (Bulletin 2755), covering single-head 2755-DS and dual-head 2755-DD units in NEMA Type 1 and Type 4 enclosures. It explains decoder features, installation and quick start, configuration from an AUX terminal (symbology, scanner control, match tables, displays, host message format and communications), ASCII and PCCC host commands, maintenance, troubleshooting and specifications.
Its parts
- Using this Manual
- Decoder Features
- Overview of Decoder Operations
- Installing the Decoder
- Introduction to AUX Terminal Configuration
- Configuration: Symbology
- Configuration: Scanner Control, Primary Match Table, Discrete I/O
- Configuration: Extended Match Table and Counters
- Configuration: AUX and LCD Display Parameters
- Configuration: Host Message Replacement Rules
- Configuration: Host Message Format
- Configuration: Host Communications
- Configuration: AUX Terminal Data Entry
- Display and System Configuration
- ASCII Host Commands
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
User manual (Publication 2755-833) for the Allen-Bradley Bulletin 2755 Series B DS single-head and DD dual-head bar code decoders, in NEMA Type 1 and Type 4 enclosures. It covers features and options, compatible scanners and cables, installation, configuration from an AUX terminal, host commands, maintenance, troubleshooting and specifications.
- Device
- Bar code decoder for Allen-Bradley laser scanners; single-head models have one scanner port, dual-head models two p. 18
- Host port
- RS-232, RS-422 and RS-485 (DH485); ASCII, or Allen-Bradley PCCC on RS485 only; 300 to 38400 baud p. 22, 292
- AUX port
- RS-232 to a standard ASCII terminal for configuration or manual data entry; 9600 baud, 8 data bits, no parity p. 21, 292
- Power
- 100 to 240 VAC nominal, 50 to 60 Hz; 80 VA max for DD decoders, 55 VA max for DS decoders p. 291
- Enclosures
- 2755-D_1_ NEMA Type 1; 2755-D_4_ NEMA Type 4 p. 18, 291
- Compatible scanners
- 2755-L4/L5, –L7/L9, –LD4 and –LD8 families; NEMA Type 1 decoders also take 2755-G3, 2755-G6, 2755-LD1 and 2755-LD2 via the 2755-NC16 Gun Adapter p. 18, 28
- Symbologies
- Code 39, Interleaved 2-of-5, Code 128, UPC-A, UPC-E, EAN-8, EAN-13, Codabar, Pharma-Code p. 292
- Catalog numbers
- 2755-DS1A, 2755-DD1A, 2755-DS4A, 2755-DD4A; Pharma-Code versions 2755-DS1P, 2755-DD1P, 2755-DS4P, 2755-DD4P p. 14
- LCD display
- Optional 2 line by 20 character backlit LCD: option R1 in the catalog number, or kit 2755-NR1 p. 27
- I/O kits
- Optional 8-position I/O Module Board; kits 2755-NB0 (connector and cable), 2755-NB1 (board) and 2755-NB2 (board with two DC outputs and one input) p. 22, 27
- Input modules
- 2755-IB5S 3.3-32 VDC; 2755-IA5S 90-140V RMS/DC; 2755-IM5S 180-280V RMS/DC p. 291
- Memory backup
- Capacitor holds configuration 6 hours at 50C or 50 hours at 30C; optional 1747-BA battery up to five years p. 22
- Communication cables
- 2755-CT1 10 foot RS-232 cable and 2755-NC17 19-pin connector kit for NEMA Type 4 decoders; 2755-CY1 DH485 multidrop cable p. 30
- Size and environment
- 10.25 (H) x 12 (W) x 4.57 (D) in; 10 lbs maximum with all options; operating 0 to 50° C (32 to 122° F) p. 291
What this manual walks you through
- Choosing scanners and scanner cables for a decoder p. 28, 29
- Choosing package detectors for the scanners p. 30
- Ordering I/O module board options p. 26, 27
- Replacing the lithium backup battery p. 283
- Replacing I/O module fuses p. 284
- Troubleshooting indicators, unread labels and excessive no-reads p. 285, 286, 287
- Fixing output LED and output module problems p. 288
Good to know
- The AUX port works for decoder configuration or for manual data entry, not both at once. p. 21
- Without the backup battery, a long power loss erases the Extended Match Code Table and the match code counters. p. 22
- Output modules act as a switch, not a power source. p. 26
- Plan at least five scans per label at full line speed, or use a faster scanner or slow the line. p. 288
- The discrete I/O LEDs still light when a module fuse is blown. p. 284
Questions this manual answers
What is the difference between the 2755-DS and 2755-DD decoders?
DS decoders are single-head with one scanner port; DD decoders are dual-head with Scanner Ports A and B. p. 18
Which scanners work with the Allen-Bradley 2755-DD decoder?
The 2755-L4/L5, –L7/L9, –LD4 and –LD8 families; NEMA Type 1 decoders also take the 2755-G3, 2755-G6, 2755-LD1 and 2755-LD2 with the 2755-NC16 Gun Adapter. p. 18, 28
What battery keeps a 2755-DD decoder's configuration?
The optional 1747-BA lithium battery, which lasts up to five years. p. 283
What fuse do the 2755 decoder output modules use?
Replacement Part No. 77104-899-01, a 1.6 A plug-in fuse. p. 26, 284
What does it mean if the CPU Active light on a 2755-DD will not stay lit?
The manual lists an internal decoder failure; the decoder goes back to Allen-Bradley for repair. p. 285
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front Cover1
- Important User Information2
- Using this Manual3
- Decoder Features3
- Overview of Decoder Operations3
- Installing the Decoder4
- Introduction to AUX Terminal Configuration4
- Configuration: Symbology5
- Configuration: Scanner Control, Primary Match Table, Discrete I/O6
- Configuration: Extended Match Table and Counters6
- Configuration: AUX and LCD Display Parameters7
- Configuration: Host Message Replacement Rules7
- Configuration: Host Message Format8
- Configuration: Host Communications8
- Configuration: AUX Terminal Data Entry8
- Display and System Configuration9
- ASCII Host Commands9
- PCCC Host Commands11
- Maintenance and Troubleshooting11
- Specifications11
- Decoder Configuration Addresses12
- Factory Default Settings12
- Transmission Check12
- Setting Up Terminals12
- Connecting to a Host12
- Protocol Selection12
- Output Module Applications12
- Electrical Interfaces for AutoLoad Applications13
- ASCII Character Set13
- Custom Settings13
- European Union Directive Compliance13
- Glossary13
- Index13
- 1 - Using this Manual14
131 more lines, from page 16 on
- Terminology16
- 2 - Decoder Features18
- Chapter Objectives18
- NEMA Type Enclosures18
- Scanner Ports18
- Power Supply19
- LED Indicators20
- LCD Display21
- AUX Port21
- Host Port22
- Power Connector and On/Off Switch22
- Memory Backup22
- Discrete I/O Modules22
- Decoder Options (NEMA Type 1 Decoders)24
- Decoder Options (NEMA Type 4 Decoders)25
- Scanners28
- Decoder Accessories28
- 3 - Overview of Decoder Operations31
- 4 - Installing the Decoder40
- Chapter Objectives40
- Power Requirements40
- Electrical Recommendations40
- Grounding41
- Replacing LED Label41
- Mounting the Decoder42
- Installing Power Cord43
- Quick Start for DS/DD Decoder Configuration and Scanner Setup45
- Connecting the AUX Terminal54
- Connecting the Host Device55
- Installing I/O Modules58
- Connecting I/O Modules to External Devices59
- Wiring I/O Modules59
- Installing Conduit Hubs/NEMA Type 4 Decoder61
- 5 - Introduction to AUX Terminal Configuration62
- 6 - Configuration: Symbology74
- 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O89
- 8 - Configuration: Extended Match Table and Counters114
- 9 - Configuration: AUX and LCD Display Parameters123
- 10 -Configuration: Host Message Replacement Rules136
- 11 - Configuration: Host Message Format155
- 12 - Configuration: Host Communications163
- 13 - Configuration: AUX Terminal Data Entry170
- 14 - Display and System Configuration183
- 15 - ASCII Host Commands189
- 16 - PCCC Host Commands266
- 17 - Maintenance and Troubleshooting283
- 18 - Specifications291
- A - Decoder Configuration Addresses294
- B - Factory Default Settings309
- C - Transmission Check312
- D - Setting Up Terminals313
- Appendix Objectives313
- Connecting Terminal to AUX Port on NEMA Type 1 Decoder313
- Connecting Terminal to AUX Port of NEMA Type 4 Decoder313
- Lear Siegler ADM 3E Terminal314
- DEC VT100 Terminal315
- Allen-Bradley 1784-T45 or T47 Programming Terminal316
- Allen-Bradley 1770-T1, -T2, -T3 Terminals317
- 2708-DH5 Attended Workstations318
- E - Connecting to a Host319
- F - Protocol Selection328
- G - Output Module Applications329
- H - Electrical Interfaces for AutoLoad Applications332
- I - ASCII Character Set335
- J - Custom Settings337
- K - European Union Directive Compliance340
- Glossary342
- Index351
- Back Cover361
The whole text · 42 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 71-7
- Pages 8 to 138-13
- 1 - Using this Manual14-17
- 2 - Decoder Features18-30
- 3 - Overview of Decoder Operations31-39
- 4 - Installing the Decoder, pages 40 to 4740-47
- 4 - Installing the Decoder, pages 48 to 5548-55
- 4 - Installing the Decoder, pages 56 to 6156-61
- 5 - Introduction to AUX Terminal Configuration62-73
- 6 - Configuration: Symbology74-88
- 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O, pages 89 to 9789-97
- 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O, pages 98 to 10698-106
- 7 - Configuration: Scanner Control, Primary Match Table, Discrete I/O, pages 107 to 113107-113
- 8 - Configuration: Extended Match Table and Counters114-122
- 9 - Configuration: AUX and LCD Display Parameters123-135
- 10 -Configuration: Host Message Replacement Rules, pages 136 to 145136-145
- 10 -Configuration: Host Message Replacement Rules, pages 146 to 154146-154
- 11 - Configuration: Host Message Format155-162
- 12 - Configuration: Host Communications163-169
- 13 - Configuration: AUX Terminal Data Entry170-182
- 14 - Display and System Configuration183-188
- 15 - ASCII Host Commands, pages 189 to 198189-198
- 15 - ASCII Host Commands, pages 199 to 208199-208
- 15 - ASCII Host Commands, pages 209 to 218209-218
- 15 - ASCII Host Commands, pages 219 to 228219-228
- 15 - ASCII Host Commands, pages 229 to 238229-238
- 15 - ASCII Host Commands, pages 239 to 248239-248
- 15 - ASCII Host Commands, pages 249 to 258249-258
- 15 - ASCII Host Commands, pages 259 to 265259-265
- 16 - PCCC Host Commands, pages 266 to 274266-274
- 16 - PCCC Host Commands, pages 275 to 282275-282
- 17 - Maintenance and Troubleshooting283-290
- 18 - Specifications291-293
- A - Decoder Configuration Addresses294-308
- B - Factory Default Settings309-311
- Pages 312 to 318312-318
- E - Connecting to a Host319-327
- Pages 328 to 331328-331
- H - Electrical Interfaces for AutoLoad Applications332-334
- Pages 335 to 339335-339
- Pages 340 to 350340-350
- Pages 351 to 361351-361
The file