Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 38 of 42

DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755), pages 328 to 331

Pages 328 to 331 of 361: F - Protocol Selection; G - Output Module Applications

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS

Page 328

-

The following table lists the available options for host communications. Physical Interface RS-232 RS-232

Flow Control None None

Communications Link Layer ACK/NAK

Application Layer ASCII ASCII

Configuration Selections RS232 RS232 ACK Character Defined NAK Character Defined

RS-232 RS-232

XON/XOFF XON/XOFF

ACK/NAK

ASCII ASCII

RS232 XON/XOFF RS232 XON/XOFF ACK Character Defined NAK Character Defined

RS-232

RTS/CTS Modem Controls RTS/CTS Modem Controls

-

ASCII

RS232 RTS/CTS-1

ACK/NAK

ASCII

RS232 RTS/CTS-1 ACK Character Defined NAK Character Defined

-

ASCII

RS232 RTS/CTS-2

ACK/NAK

ASCII

RS232 RTS/CTS-2 ACK Character Defined NAK Character Defined

RS-232

RS-232 RS-232

RTS/CTS Bulletin 2760 Modem Controls RTS/CTS Bulletin 2760 Modem Controls

RS-422 RS-422

None None

ACK/NAK

ASCII ASCII

RS422 RS422 ACK Character Defined NAK Character Defined

RS-422 RS-422

XON/XOFF XON/XOFF

ACK/NAK

ASCII ASCII

RS422 XON/XOFF RS422 XON/XOFF ACK Character Defined NAK Character Defined

RS-485

DH485 Local Area Network

DH485 Local Area Network

PCCC with Write Replies

RS-485

DH485 Local Area Network

DH485 Local Area Network

PCCC without Write Replies

RS-485

DH485 Local Area Network

DH485 Local Area Network

ASCII with Responses

RS-485

DH485 Local Area Network

DH485 Local Area Network

ASCII without Responses

RS485 PCCC-1 LSAP 128 or 1 RS485 PCCC-2 LSAP 128 or 1 RS485 ASCII-1 LSAP 128 or 1 RS485 ASCII-1 LSAP 128 or 1

Publication 2755-833

Page 329

Output Module Applications Figures G.1 through G.3 show typical output module applications. Outputs are open when power is first applied to the decoder (during initial diagnostics) and again when the decoder is powered off.

DC Output Module Application Figure G.1 illustrates a typical DC output module application. When using high impedance loads, you may have to add an additional resistor (R) in parallel with the load. Select a value for R that maintains a minimum current of 10mA through the output module in the closed state. Typical R values range from 300 to 6,000 ohms depending on the source voltage. Figure G.1 DC output module application MOD 1-8

DC Output Module➀

Connector Block

–4+ Fuse

Load

Enclosure Conduit Hole

R

– +

DC Source 3-60 VDC ➀ Output module functions as switch, not a power source.

Note: For highly inductive or capacitive loads, make sure that the current does not exceed the maximum ratings of the fuse or module. You can use a diode to protect the module. See Figure G.3.

Publication 2755-833

Page 330

G–2

Output Module Applications

AC Output Module Application Figure G.2 illustrates a typical AC output module application. When using high impedance loads, you may have to add an additional resistor (R) in parallel with the load. Select a value for R that maintains a minimum current of 50 mA RMS through the output module in the closed state. Figure G.2 AC output module application MOD 1-8

AC Output Module➀

Connector Block

–2+ Fuse

Load

Enclosure Conduit Hole

R

AC Source ➀ Output module functions as switch, not a power source.

Note: For highly inductive or capacitive loads, make sure that the current does not exceed the maximum ratings of the fuse or module. You can use a diode to protect the module. See Figure G.3.

Using a Diode to Protect Output Module Back EMF (Electromotive Force) is sometimes generated when an inductive load is switched off. Back EMF takes the path of least resistance into the output module, which may cause the module to blow. To protect the module from back EMF, insert a diode in parallel with the inductive device to dissipate back EMF.

Publication 2755-833

Page 331

Output Module Applications

G–3

Figure G.3 Using diode to protect module MOD 1-8

DC Output Module➀

Connector Block

–2+ Fuse

Load

Enclosure Conduit Hole

Diode

– +

DC Source ➀ Output module functions as switch, not a power source.

Publication 2755-833