For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS

Page 332

Electrical Interfaces for AutoLoad Applications There are three ways to activate the AutoLoad function described in Chapter 5: 1. 12 VDC power supply terminal on I/O Module board connects to input module (in position 8 of I/O Module Board) and a normally opened (N.O.) contact, providing power to the input module. See Figure H.1. 2. External AC or DC power source connects to input module (in position 8 of I/O Module Board) and a normally opened (N.O.) contact, providing power to the input module. See Figure H.2 3. A normally opened (N.O.) contact connects directly to pins in AUX Port Connector. This method does not require an I/O Module Board with installed input module or a power source. See Figure H.3.

AutoLoad Input Module Application (powered internally) Figure H.1 illustrates the AutoLoad Input module application that is powered internally. A DC input module is installed in position 8 of the I/O Module Board. A switch (N.O. contact) provides input to the module to load bar code data into the match code table. The module and switch receive power from the 12 V DC terminal on the I/O board. Figure H.1 AutoLoad input module application (powered internally) MOD8 Only DC Input Module

12 V DC Power Source Connector Block

–8+

–

+

Fuse

Enclosure Conduit Hole Mechanical or PhotoElectric Switch

Publication 2755-833

Page 333

H–2

Electrical Interfaces for AutoLoad Applications

AutoLoad Input Module Application (powered externally) Figure H.2 illustrates the AutoLoad Input module application that is powered externally. An AC/DC input module is installed in position 8 of the I/O Module Board. A push button (normally opened contact) provides input to the module to load bar code data into the match code table. The module and switch receive power from an external AC or DC source.

!

ATTENTION: To guard against enclosure damage, align the conduit so as to prevent unnecessary stress on the enclosure walls.

Figure H.2 AutoLoad input module application (powered externally MOD8 Only AC/DC Input Module

Auto Load Push Button Connector Block

–8+ Fuse

+

Enclosure Conduit Hole

–

–

+

AC or DC Source

AutoLoad Activated by Aux Port Connector Another way to activate the AutoLoad function is by connecting a push button (normally opened contact) directly to pins 17 and 25 (or K and L) of the AUX port connector. This method does not require an I/O Module Board with installed input module or a power source.

Publication 2755-833

Page 334

Electrical Interfaces for AutoLoad Applications

H–3

Figure H.3 shows the connection between a normally opened contact and pins on the NEMA Type 1 or NEMA Type 4 connector. Figure H.3 AutoLoad function activated by AUX connector NEMA Type 1 Aux Port (female) Connector 1

NEMA Type 4 Aux Port (Male) Connector

14 M

17

L K

A N

J

R S

H 25

C

V T

13

B P

U

D E

G F

Use the Catalog No. 2755-NC17 Connector Kit to fabricate cable.

Publication 2755-833