Page 249

ASCII Host Commands

15–61

IB - Configure Scanner B Source Identifier Command Format: IBlstring Function:

Defines a source identifier for Scanner B. Source identifiers are included in messages sent to the host. They identify whether the data was scanned (by Scanner A or B) or entered at the AUX terminal. NOTE: This command is valid only for dual head decoders.

Parameters:

lstring

Command Parameter l String

Parameter Function

Valid Values

Length of source identifier

0 to 4①

Characters in source identifier

Up to 4 characters

① A zero length string will disable the source identifier.

= rr <end>

Response:

rr = response code <end> = end of message control code Example: Command:

IB4SCNB

Parameters:

4SCNB

Command Parameter l String

Response:

Parameter Function

Values

Length of source identifier

4

Characters in source identifier

SCNB

= 00LF 00 = command complete response code LF= end of message control code for Line Feed

Publication 2755-833

Page 250

15–62

ASCII Host Commands

HM - Configure Header Message Command Format: HMIIstring Function:

Defines a header message for bar code data.

Parameters:

llstring

Command Parameter ll

Length of header message

00 to 32①

String

Header message characters

Up to 32 characters

Parameter Function

Valid Values

① A zero length string will disable the header message.

= rr <end>

Response:

rr = response code <end> = end of message control code Example: Command:

HM03A-B

Parameters:

03A-B

Response:

Command Parameter ll

Length of header message

03

String

Header message characters

A-B

Parameter Function

Values

= 00LF 00 = command complete response code LF = end of message control code for Line Feed

Publication 2755-833

Page 251

ASCII Host Commands

15–63

NM - Configure Default No-Read String Command Format: NMIIstring Function:

Defines a no-read message for bar codes that could not be scanned or decoded. No-read messages are optionally included in messages sent to the host.

Parameters:

llstring

Command Parameter ll

Length of no-read message

00 to 32①

String

No-read message characters

Up to 32 characters

Parameter Function

Valid Values

① A zero length string disables a no read string.. A nonzero length string enables the no read string

= rr <end>

Response:

rr = response code <end> = end of message control code Example: Command:

NM07NO-READ

Parameters:

07NO-READ

Response:

Command Parameter ll

Length of no-read message

07

String

No-read message characters

NO-READ

Parameter Function

Values

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return

Publication 2755-833

Page 252

15–64

ASCII Host Commands

AX - Configure AUX Terminal Data Entry Operations Command Format: AXabceeefgg Function:

Configures AUX terminal data entry parameters. These parameters take effect when the AUX port is set to manual data entry mode (as described in Chapter 13).

Parameters:

abceeefgg

Command Parameter

Response:

Parameter Function a

Enable keyboard entry?

b

Confirm entry?

c

Format AUX Keyboard Data?

eee

Rubout character for keyboard data entry?

f

Echo keyboard data?

gg

Size of the display.

Valid Values 0= No 1= Yes 2= No-Read 0= No 1= Yes 0= Unformatted 1= Host Format ASCII Decimal Value 000 to 255 255 = None 0= No 1= Yes 10 through 80

= rr <end> rr= response code <end>= end of message control code

Publication 2755-833

Page 253

ASCII Host Commands

15–65

AX - Configure AUX Terminal Data Entry Operations (continued) Example: Command:

AX111008180

Parameters:

111008180

Command Parameter a b

1= Yes

Confirm entry?

1= Yes f gg

Size of the display.

eee

Values

Enable keyboard entry? Format Aux Terminal Keyboard Data? Rubout character for keyboard data entry Echo keyboard data?

c

Response:

Parameter Function

1= Host Format ASCII Decimal Value 008 = backspace 1= Yes 80

= 00CR 0= response code CR= end of message control code

Publication 2755-833

Page 254

15–66

ASCII Host Commands

TM - Display Text Message at AUX Terminal and LCD Command Format: TMfllstring Function:

Sends a message to the AUX port terminal (and/or LCD Display) and optionally enables the keyboard for one message. If a text message is not defined, the Default Prompt Message is sent.

Parameters:

fllstring

Command Parameters

Valid Values

Enable keyboard entry for one 1= Yes message. 0= No Length of text message. 00 through 80 f ll String

Response:

Parameter Function

Text message characters.

Up to 80 characters

= rr <end> rr= response code (see Table 17.D) <end>= end of message control code Note: If the previous message has not displayed, the response returns a code of 02 to indicate the command failed because the display buffer was not available. If the AUX port is set to configuration mode, (CONFIG jumper is open), the response returns a code of 01. The message will display on the LCD Display but not the AUX terminal.

Publication 2755-833

Page 255

ASCII Host Commands

15–67

TM - Display Text Message at AUX Terminal and LCD (continued) Example: Command:

TM111MESSAGETEXT

Parameters:

111MESSAGETEXT Command Parameters f ll String

Response:

Parameter Function

Values

Enable keyboard entry for one 1= Yes message. Length of text message. 11 Text message characters.

MESSAGETEXT

=00CR 00 = command complete response code CR= end of message control code for Carriage Return

Publication 2755-833

Page 256

15–68

ASCII Host Commands

PM - Default Prompt Message for AUX Terminal Command Format: PMllstring Function:

Defines the default prompt message for the AUX port terminal.

Parameters:

llstring

Command Parameters ll String

Parameter Function Length of the AUX terminal prompt message AUX terminal prompt message string.

Valid Values 00 through 20 Up to 20 characters

= rr <end>

Response:

rr = response code <end>= end of message control code Example: Command:

PM11ENTER DATA:

Parameters:

11ENTER DATA:

Command Parameters ll String

Response:

Parameter Function Length of the AUX terminal prompt message AUX terminal prompt message string.

Values 11 ENTER DATA:

=00CR 00 = command complete response code CR = end of message control code for Carriage Return

Publication 2755-833

Page 257

ASCII Host Commands

15–69

PI - Read Decoder Performance Indicators Command Format: PI Function:

Reads the decoder performance indicators for Scanners A and B.

Parameters:

None

Response Parameters

Parameter Function aaa

Scanner A Performance Indicator bbb

Scanner B Performance Indicator

Valid Values 3 digit value 000 through 100, 999① 3 digit value 000 through 100, 999①②

① 999 indicates the decoder is not decoding because of a buffer overflow condition. ② Applicable only with dual head scanner.

aaa<end> = rr <end> for single head scanners, or aaabbb<end> = rr <end> for dual head scanners.

Response:

<end>= end of message code rr= response code <end>= end of message code Example: Command:

PI

Response:

000099LF = 00LF Response Parameters aaa bbb

Parameter Function Scanner A Performance Indicator Scanner B Performance Indicator

Values 000 099

LF= end of message control code 00= command complete response code LF= end of message control code

Publication 2755-833

Page 258

15–70

ASCII Host Commands

PR - Read Package Counter Command Format: PR Function:

Returns the count maintained by the package counter.

Parameters:

None

Response:

pppppp<end>= rr <end> pppppp= package count, up to 999999 <end>= end of message control code rr = response code <end>= end of message control code

Example: Command:

PR

Response:

000075LF = 00LF 000075= number of packages read by decoder LF= end of message code for Line Feed 00= command complete response code L= end of message code for Line Feed

Publication 2755-833