DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): 14 - Display and System Configuration

Pages 183 to 188 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS

Page 183

Chapter

14

Display and System Configuration Chapter Objectives

This chapter describes how to use the bar code decoder configuration software to: • Display bar code strings • Display decoder performance indicators and counters • Reset status and counters • Restart the system • Select a new language option • Save the current configuration.

Connect and Set Up AUX Terminal

To use the built-in configuration menus and screens, you must first connect a terminal to the RS-232 AUX port of the decoder. Appendix D provides details on how to connect and setup each terminal. The AUX port communication parameters are:

• • • • •

8 Data Bits 1 Stop Bit 9600 Baud Rate Parity None XON/XOFF Flow Control

Refer to Chapter 5 for information on getting started with the AUX communication software.

Publication 2755-833

Page 184

14–2

Display and System Configuration

Display Bar Code Strings

The Display Bar Code Strings function on the Select Operation menu allows you to monitor bar code labels as they are decoded.

To select this function, press the “A” or “a” key. The screen will clear and display decoded bar code strings. You might see:

The data from each string displays on a separate line. If several symbols are decoded in one scan, the symbols are displayed on a single line, separated by a space.

Publication 2755-833

Page 185

Display and System Configuration

14–3

Each line displays a maximum of 80 characters. If the data consists of more than 80 characters, it continues to the next line until the entire string is displayed. If the decoder is unable to decode a bar code label, the no-read message (if defined during configuration) is displayed. The display continuously scrolls upward, displaying new bar code data at the bottom of the screen. To exit this function and return to the Select Operation menu, press [ESC].

Display Status and Primary Counters

The Display Status and Primary Counters function on the Select Operation menu allows you to monitor system status and counters maintained by the decoder. To select this function, press the “B” or “b” key. The following screen displays:

Publication 2755-833

Page 186

14–4

Display and System Configuration

The decoder performance indicators and counters are updated on the display once each second. Following is a description of each display item. Decoder Performance In continuous mode, the performance indicators display the (Scanner A and B) percent of decoded scans for each scanner. In triggered mode, the performance indicators display the number of valid scans (up to 100) during a trigger active period for Scanner A and Scanner B. Note: The decoder performance will never exceed the capture count if Send Message to Host is set to Immediately After Valid Package. Decoder performance indicators are useful during: - initial setup (when the decoder is in continuous mode) to determine the optimum location of the scanner relative to the bar code labels. - decoder operation to identify a decrease in performance. For example, if the number of good reads drops significantly, the label quality may have degraded or the scan head window may require cleaning. Note: If a buffer overflow occurs while collecting data for the sample scans, the value 999 displays until the condition is corrected. This occurs if host communications is suspended. Symbols Not Read Displays the number of symbols not read in the triggered Counter mode of operation. A no-read occurs when the decoder does not decode the correct number of symbols on a package as defined by the Symbols per Package parameter. The counter increments for each symbol not read in a package. Package Counter Displays the number of packages detected by the decoder. The package counter increments each time a trigger is generated by the package detector, a host command, or the internal timer. It also increments each time a package is read in the continuous or continuous/unique operation modes. Primary Counters Displays the number of output conditions that occur for each (1-8) discrete output (1-8). Each output counter increments when a TRUE condition occurs for that output.

Publication 2755-833

Page 187

Display and System Configuration

14–5

The counters are six digit values that increment up to 999999. When exceeding 999999, the display automatically advances to 000000. To exit this function and return to the Select Operation menu, press [ESC].

Resetting the Counters You can reset the decoder status and counters to zero from the Display Status and Counters screen. You can reset individual counters by pressing a number 1 through 8, and answering [Y] to the confirmation request that appears on the bottom of the screen. You can reset reset the decoder status and all primary counters to zero by pressing the [Space] bar. Press [Y] to reset the status and counters. Press [N] or [Esc] to cancel the operation. This operation is identical to the Reset Status and Counters function on the Select Operation menu. Note: The counters also reset when you restart the system with function Restart System. There is a second way to reset the decoder performance indicators and all counters to zero from the Select Operation menu, select the Reset Status and Primary Counters function. Press the “C” or “c” key. Press [Y] to reset the decoder performance indicators and counters to zero. Press [N] or [Esc] to cancel the operation. This operation is identical to pressing [Space] on the Display Status and Counters screen.

Restart System

The Restart System function allows you restart the decoder. This operation reboots the decoder, enables autoload functions, and enables lotting, and activates certain host communications parameters (Refer to Chapter 12). To restart the decoder, press the “E” or “e” key. Press [N] or [Esc] to cancel the operation and return to the Select Operation menu. Press [Y] to restart the decoder. During a restart, all configuration parameters are reset to the values last saved to storage memory, and the Select Language screen is displayed.

Publication 2755-833

Page 188

14–6

Display and System Configuration

Select Language

The Select Language function allows you to access the Select Language screen. Press the “F” or “f” key from the Select Operation menu.

Press the number key that corresponds to the language you want to use. All subsequent screens display in the selected language.

Save Configuration

Publication 2755-833

To save the current system settings in storage memory, type “G” or “g” or select Save Configuration on the Select Operation menu. Press [N] or [Esc] to cancel the save operation and return to the Select Operation menu. Press [Y] to save the current configuration. All configuration parameters are saved to storage memory.