The text of a manual · part 24 of 42
DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): 15 - ASCII Host Commands, pages 209 to 218
Pages 209 to 218 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS
Page 209
ASCII Host Commands
15–21
IF - Configure Scanner A Package Detect Filter and Sense Command Format: IFf Function:
Enables or disables the 15 ms input filter and determines the sense of the package detect signal for Scanner A.
Parameters:
f = disable or enable filter/select sense.
Command Parameter
Parameter Function
Valid Values 0=disable filter, LO when package is present
Enable or disable filter/select sense f
1=enable filter, LO when package is present 2=disable filter, HI when package is present 3=enable filter, HI when package is present
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
IF1
Parameters:
1
Command Parameter f
Response:
Parameter Function Enable or disable filter/select sense
Value 1=enable filter, LO when package is present
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 210
15–22
ASCII Host Commands
BF - Configure Scanner B Package Detect Filter and Sense Command Format: BFf Function:
Enables or disables the 15 ms input filter and determines the sense of the package detect signal for Scanner B. NOTE: This command is valid only for dual head decoders.
Parameters:
f = disable or enable filter/select sense.
Command Parameter
Parameter Function
Valid Values 0=disable filter, LO when package is present
Enable or disable filter/select sense f
1=enable filter, LO when package is present 2=disable filter, HI when package is present 3=enable filter, HI when package is present
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
BF1
Parameters:
1
Command Parameter f
Response:
Parameter Function Enable or disable filter/select sense
Value 1=enable filter, LO when package is present
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 211
ASCII Host Commands
15–23
BL - Configure Scanner B Laser Mode Command Format: BLa Function:
Configures the laser light for scanner B. NOTE: This command is valid only for dual head decoders.
Parameters:
a
Command Parameters a
Response:
Parameter Function Scanner B laser light
Valid Values 0= On 1= Triggered 2= Off
= rr <end> rr = response code <end> = end of message control code
Example: Command:
BL1
Parameters:
1
Command Parameters a
Response:
Parameter Function Scanner B laser light
Values 1=Triggered
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 212
15–24
ASCII Host Commands
SW - Write Scanner Source to Match Code Table Command Format: SWab Function:
Configures the source of an event.
Parameters:
ab
Command Parameters a b
Parameter Function Match code table entry number
Source of event
Valid Values 1 through 8 1=Scanner A 2=Scanner B① 3=A|B① 4=Illegal 5=A–B①
① Applies only to Dual-Head Decoder.
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
SW11
Parameters:
1
Command Parameters a b
Response:
Parameter Function
Values
Match code table entry number
1
Source of event
1=Scanner A
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 213
ASCII Host Commands
15–25
AB - Auto-load Begin Command Format: AB Function:
Resets autoloads. Once received, the decoder loads match code table positions set to autoload with decoded bar code data until it receives an AE (Autoload End command. Equivalent to manual autoload input.
Response:
= rr <end> rr = response code <end>= end of message control code
Example: Command:
AB
Response:
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
AE - Autoload End Command Format: AE Function:
Stops loading data into position set to autoload. This command follows an AB (Autoload Begin) command. Equivalent to releasing a manual autoload input.
Response:
= rr <end> rr = response code <end> = end of message control code
Example: Command:
AE
Response:
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 214
15–26
ASCII Host Commands
AL - Autoload Command Format: ALabeestring Function:
Load the match pattern into the next available position set to autoload, checking first the primary match table, and then the extended match table. This is the equivalent of a manual Autoload, except the data is supplied by the host instead of a scanner.
Parameters:
abeestring
Command Parameters a
Response:
Parameter Function
Valid Values 1=A 2=B
Source b
Symbology
1=Code 39 2=Interleaved 2-of-5 3=Codabar 4=UPC-A 5=UPC-E 6=EAN-8 7=EAN-13 8=Code 128 9=Pharma–Code ee
Length of match string
00 to 32 string
Match string
Up to 32 ASCII characters
= rr <end> rr = response code <end>= end of message control code
Publication 2755-833
Page 215
ASCII Host Commands
15–27
AL - Autoload (continued) Example: Command:
AL
Parameters:
1110ABCDE12345
Command Parameters a
Response:
Parameter Function
Valid Values
Source
1=A b
Symbology
1=Code 39 ee
Length of match string
10 Characters
String
Match string
ABCDE12345
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 216
15–28
ASCII Host Commands
OS - Set Output Normally Open/Closed Command Format: OSnf Function:
Sets the state of a discrete output to normally open or normally closed. Parameters: nf
Command Parameters n f
Parameter Function
Valid Values
Discrete output number
1 through 8
Switch operation normally open or normally closed
0= Normally Open 1= Normally Closed
= rr <end>
Response:
rr = response code <end>= end of message control code Example: Command:
OS20
Parameters:
20
Command Parameters n f
Response:
Parameter Function
Values
Discrete output number
2
Switch operation normally open or normally closed
0= Normally Open
=00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 217
ASCII Host Commands
15–29
OC - Set Output Condition and Output Duration Command Format: OCnctttt Function:
Sets the condition that will activate an output and the length of time (in milliseconds) the output is activated.
Parameters:
nctttt
Command Parameters n
Parameter Function Output number
Valid Values 1 through 8 c
Condition activates output
0= None 1= Read (Package) 2= No-Read (Package) 3= Match Complete 4= Match Entry 5= Read and No-Match 6= No-Read or No–Match 7= Auto Load 8= Auto Load (Input)① 9= Host buffer full A= Host buffer overflow tttt
Time (in milliseconds) that output is activated.
0000, 0010 to 9999 (milliseconds) 0000 disables condition
① The AutoLoad (Input) function applies only to output 8.
Response:
= rr <end> rr = response code <end> = end of message control code
Publication 2755-833
Page 218
15–30
ASCII Host Commands
OC - Set Output Condition and Output Duration (continued) Example: Command:
OC510110
Parameters:
510110
Command Parameters n
Response:
Parameter Function Output number
Values 5 c
Condition that activates output 1= Read (Package)
tttt
Time (in milliseconds) that output is activated.
0110= 110 milliseconds
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833