Page 219

ASCII Host Commands

15–31

OH - Hold Output Open/Closed Command Format: OHnfftttt Function:

Allows the host to control the discrete outputs (regardless of their ”normal” state) for a set duration.➀ When the duration expires, the output reverts to its previous state. Note: If a normally open output is held open (or a normally closed output is held closed), the state of the output will not change.

!

ATTENTION: An output held open or closed will reestablish itself after a power loss (all other conditions will be deactivated if power is lost). A Restart command will deactivate a held output.

Parameters:

nfftttt

Command Parameters n ff tttt

Response:

Parameter Function

Valid Values

Discrete output number

1 through 8

Hold switch operation in open or closed state? Time (in milliseconds) that output remains in held state. When the time expires, the output returns to its previous state.

00= Hold Open➀ 11= Hold Close 0000, 0010 to 9999 (milliseconds) 0000 holds output in state until changed.

= rr <end> rr = response code <end> = end of message control code

➀ A duration of 0000 holds the specified output in the programmed state until it is changed with host command or via the AUX terminal configuration screens. The condition field on the AUX will display Open or Closed.

Publication 2755-833

Page 220

15–32

ASCII Host Commands

OH - Hold Output Open/Closed (continued) Example: Command:

OH2001000

Parameters:

2001000

Command Parameters n

Discrete output number

2 ff

State of discrete output

00= Hold Open tttt

Time (in milliseconds) that output remains held open.

1000 milliseconds

Response:

Parameter Function

Values

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return

Publication 2755-833

Page 221

ASCII Host Commands

15–33

MR - Read Primary Match Code Table Entry Command Format: MRn Function:

Read match code configuration for table entry 1 – 8.

Parameters:

n = match code table entry number 1 through 8.

Command Parameters n

Parameter Function

Valid Values

Match code table entry number

1 through 8

RESERVED

1① cc

Bar code symbology

01=Code 39 02=Interleaved 2 of 5 03=Codabar 04=UPC-A 05=UPC-E 06=EAN-8 07=EAN-13 08=Code 128 09=Pharma–Code 16=Any ll

Length of match string

00 to 32

Match string up to 32 characters f string

① This value is always returned as 1.

nfccllstring<end> = rr <end>

Response:

<end> = end of message control code rr = response code <end> = end of message control code Example: Command:

MR3

Parameters:

3 = match code entry #3

Command Parameters n

Parameter Function

Values

Match code table entry number

3 f

RESERVED

1① cc

Bar code symbology

01=Code 39 ll

Length of match string

05

Match string

12345 string

① This value is always returned as 1.

Response:

31010512345CR = 00CR CR = end of message control code 00 = command complete response code CR = end of message control code

Publication 2755-833

Page 222

15–34

ASCII Host Commands

MW - Write Primary Match Code Table Entry Command Format: MWnfccllstring Function:

Configure a match code for table entry 1 – 8.

Parameters:

nfccllstring

Command Parameters n

Parameter Function

Valid Values

Match code table entry number

1 through 8

RESERVED

Ignored① cc

Bar code symbology

01=Code 39 02=Interleaved 2 of 5 03=Codabar 04=UPC-A 05=UPC-E 06=EAN-8 07=EAN-13 08=Code 128 09=Pharma–Code 16=Any ll

Length of match code string

00 to 32②

Match code characters up to 32 characters③ f string

① Decoder ignores character but it must be supplied to maintain compatibility with previous decoders. ② A zero length string disables a match code entry. A nonzero length string enables the match code entry. ③ The string must be as long as the specified string length (ll).

Response:

= rr <end> rr= response code <end> = end of message control code

Publication 2755-833

Page 223

ASCII Host Commands

15–35

MW - Write Primary Match Code Table Entry (continued) Example: Command:

MW4102041289

Parameters:

4102041289

Command Parameters n

Parameter Function

Values

Match code table entry number

4 f

RESERVED

1 cc

Bar code symbology

02=Interleaved 2 of 5 ll

Length of match string

04

Match string

1289 string

Response:

= 00LF 00 = command complete response code LF = end of message control code for Line Feed

CM - Clear Primary Output Counters Command Format: CMn Function:

Clears the selected output counter to 0.

Parameters:

n = output counter number 1 through 8

Response:

= rr <end> rr = response code <end > = end of message control code

Example: Command:

CM3

Parameters:

3 = output counter #3.

Response:

= 00CR 00= command complete response code CR = end of message control code for Carriage Return

Publication 2755-833

Page 224

15–36

ASCII Host Commands

CO - Clear All Primary Output Counters Command Format: CO Function:

Clears the Primary Counters to zero.

Parameters:

None

Response:

= rr <end> rr = response code <end>= end of message control code

Example: Command:

CO

Response:

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return

CA - Clear Extended Match Counters Command Format: CA Function:

Clears the value of the extended counts to zero.

Parameters:

None

Response:

= rr <end> rr = response code <end> = end of message control code

Example: Command:

CA

Response:

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return

Publication 2755-833

Page 225

ASCII Host Commands

15–37

SE - Set Extended Match Counters Command Format: SEnnnmmmmmm Function:

Sets the value of extended count number nnn to mmmmmm.

Parameters:

nnnmmmmmm

Command Parameters nnn mmmmmm

Parameter Function

Valid Values

The number of the Extended match count The value of the count

001 to 128 000 = All 000000 to 999999

= rr <end>

Response:

rr = response code <end> = end of message control code Example: Command:

SC012000036

Parameters:

012

Command Parameters nnn mmmmmm

Response:

Parameter Function The number of the Extended match count. The value of the count

Values 012 000036

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.

Publication 2755-833

Page 226

15–38

ASCII Host Commands

RC - Read Extended Match Counters Command Format: RCnnn Function:

Reads the value of Extended count number nnn.

Parameters:

nnn

Command Parameters

Parameter Function The number of the Extended match count nnn

Valid Values 001 to 128

= mmmmmm <end>

Response:

mmmmmm = count value <end> = end of message control code Example: Command:

RC012

Parameters:

012

Command Parameters nnn

Response:

Parameter Function The number of the Extended match count.

Values 012

= 000036CR 000036 = value of counter 12 CR = end of message control code for Carriage Return.

Publication 2755-833

Page 227

ASCII Host Commands

15–39

SM - Set Extended Match Data Command Format: SMnnnasccmmmmmmddddddddllstring Function:

Sets the value of the Extended data number nnn.

Parameters:

nnnasccmmmmmmddddddddllstring

Command Parameters nnn a

Parameter Function

Valid Values

The number of the Extended match count

000 to 128

Mode

A=Auto-load M=Match Entry D=Disabled L=Lot s

Source cc symbology

1=Scanner A 2=Scanner B 3=A|B 4=Illegal 5=A–B 01=Code 39 02=Interleaved 2-of-5 03=Codabar 04=UPC-A 05=UPC-E 06=EAN-8 07=EAN-13 08=Code 128 09=Pharma–Code 16=Any mmmmmm

The value of the count

000000 to 999999 dddddddd

Loading (8)

0 to 9, or X

Length of match string

00 to 32

Match string up to 32 characters ll string

Response:

= rr <end> rr = response code <end>= end of message control code

Publication 2755-833

Page 228

15–40

ASCII Host Commands

SM - Set Extended Match Data (continued) Example: Command:

SM002M30100000010000000041289

Parameters:

002 M 3 01 000000 10000000 04 1289

Command Parameters

Parameter Function

Valid Values a

The number of the Extended match count Mode s

Source

3=A|B cc nnn

002 M = Match Entry

Symbology

01=Code 39 mmmmmm

The value of the count

000000 dddddddd

Loading (8)

10000000

Length of match string

04

Match string

1289 ll string

Response:

= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.

Publication 2755-833