ASCII Host Commands
15–41
RP - Read All Extended Match Data Command Format: RP Function:
Reads the value of all Extended data.
Parameters:
None
Response Parameters
Parameter Function
Valid Values
The number of the Extended match counts
001 to 128
Mode
A=Auto-load M=Match Entry D=Disabled L=Lot
Source
01=Scanner A 02=Scanner B 03=A|B 04=A–B
Symbology
01=Code 39 02=Interleaved 2-of-5 03=Codabar 04=UPC-A 05=UPC-E 06=EAN-8 07=EAN-13 08=Code 128 09=Pharma–Code 16=Any mmmmmm
The value of the count
000000 to 999999 ll
Length of match string
00 to 32
Match string up to 32 characters nnn a ss cc string
Response:
001assccmmmmmmmmllstring<end>.. ... 128assccmmmmmmmmllstring<end> =rr<end> rr = response code <end>= end of message control code
Publication 2755-833
Page 230
15–42
ASCII Host Commands
RP - Read All Extended Match Data (continued) Example: Command:
RP
Response:
001 M 03 01 001289 04 1289 CR 002 ... ... 128 M 03 01 001289 04 1289 CR =00CR
Command Parameters
Parameter Function
Values a
The number of the Extended match counts Mode s
Source
03=A|B cc nnn
064 M = Match Entry symbology
01=Code 39 mmmmmm
The value of the count
001289 ll
Length of match string
04
Match string
1289 a
Mode
M = Match Entry s
Source
3=A|B cc
Symbology
01=Code 39 mmmmmm
The value of the count
000222 ll
Length of match string
04
Match string
6247 string string
CR = delimiter and/or end of message control code for Carriage Return 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 231
ASCII Host Commands
15–43
RA - Read All Extended Counters Command Format: RA Function:
Reads all Extended counts.
Parameters:
None
Response:
nnnmmmmmm<end>... ... nnnmmmmmm<end> = rr <end>
Response Parameters nnn mmmmmm nnn mmmmmm
Parameter Function The number of the Extended match count Value of count The number of the Extended match count Value of count
Valid Values 001 000000 to 999999 002 000000 to 999999
... nnn mmmmmm
The number of the Extended match count Value of count
128 000000 to 999999 rr= response code <end> = end of message control code
Publication 2755-833
Page 232
15–44
ASCII Host Commands
RA - Read All Extended Counters (continued) Example: Command:
RA
Parameters:
None
Response:
001000012CR002000122... ... 128000012CR =00CR
Response Parameters nnn mmmmmm nnn mmmmmm
Parameter Function The number of the Extended match count Value of count The number of the Extended match count Value of count
Values 001 000012 002 000122
... nnn mmmmmm
Response:
The number of the Extended match count Value of count
128 000000
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 233
ASCII Host Commands
15–45
CS - Disable Extended Match Code Set Command Format: CSnnnnnnnn Function:
Disables a group of Extended Match Codes
Parameters:
nnnnnnnn
Command Parameters
Parameter Function
Valid Values nnnnnnnn
Allows the 128 Extended Match Codes to be treated as eight sets of sixteen each. Each set can be individually marked.
00000000 = All Disabled through 11111111=All enabled
Response:
= rr <end> rr = response code <end> = end of message control code
Example: Command:
CS01100011
Parameters:
01100011
Command Parameters
Parameter Function nnnnnnnn
Enables positions 17–32, 33–48, 97–112, and 113–128
Response:
Values
01100011
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 234
15–46
ASCII Host Commands
RS - Read Extended Match Set Status Command Format: RS Function:
Reads the status of the extended match sets.
Parameters:
none
Response:
nnnnnnnn = rr <end> rr = response code <end> = end of message control code
Example: Command:
RS
Response:
10010001 = 00CR 10010001 = Sets 1, 4, and 8 enabled; all others disabled. 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 235
ASCII Host Commands
15–47
DF - Enable Data Display on AUX Terminal and LCD Command Format: DFab Function:
Enables the AUX terminal and/or the LCD Display to receive and display bar code data. Note: Before data will display at the AUX terminal, you must set the AUX port to manual data entry mode (as described in Chapter 13). ab
Parameters:
Command Parameter
Parameter Function
Valid Values a
Enable device to display formatted bar code data.
0= None 1= AUX terminal and LCD Display 2= AUX terminal only 3= LCD Only b
Specify format of bar code data.
0= Unformatted 1= Host format
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
DF11
Parameters:
11
Command Parameter a b
Response:
Parameter Function Enable device to display formatted bar code data. Specify format of bar code data.
Values 1= AUX terminal and LCD Display
1= Host format
= 00LF 00 = command complete response code LF = end of message control code for Line Feed
Publication 2755-833
Page 236
15–48
ASCII Host Commands
DP - Configure Data Display Positions for AUX Terminal and LCD Command Format: DPdpp Function:
Enables the display of specific data items on the LCD and/or AUX port terminal starting at a specific character position. Note: Before data will display at the AUX terminal, you must set the AUX port to manual data entry mode (as described in Chapter 13). dpp
Parameters:
Command Parameter
Parameter Function
Valid Values d
Data item selector
A= Bar Code Data B= Decoder Performance C= Package Counter D= No-Read Counter 1= Primary Counter 1 2= Primary Counter 2 3= Primary Counter 3 4= Primary Counter 4 5= Primary Counter 5 6= Primary Counter 6 7= Primary Counter 7 8= Primary Counter 8 pp
Character position
00, 01 - 80 00= Disable
= rr <end>
Response:
rr= response code <end>= end of message control code Example: Command:
DPA01
Parameters:
A01
Response:
Command Parameter d
Parameter Function Data item selector
A= Bar Code Data pp
Character position
01
Values
= 00LF 00 = command complete response code LF = end of message control code for Line Feed
Publication 2755-833
Page 237
ASCII Host Commands
15–49
SD - Enable LCD Scrolling Command Format: SDf Function:
Enables or disables scrolling of the LCD display.
Parameters:
f
Command Parameters
Parameter Function f
Enable Scrolling LCD Display
Values 0= No 1= Yes
See Chapter 9 for details on how the LCD Display operates when scrolling is enabled or disabled. = rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
SD1
Parameters:
1
Command Parameters f
Response:
Parameter Function Enable scrolling LCD Display
Values 1= Yes
=00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 238
15–50
ASCII Host Commands
SR - Set Search and Replace Rule for Host Message Fields Command Format: SRnnmmsccbbffapppllstringllstring Function:
Set parameters for the host message replacement rules.
Parameters:
nnmmsccbbffapppllstringllstring
Command Parameters
Valid Values mm
The number of the Search and Replace Rule The host message field number s
Source
1=Scanner A 2=Scanner B 3=A|B 4=Aux cc
Symbology
01=Code 39 02=Interleaved 2-of-5 03=Codabar 04=UPC–A 05=UPC–E 06=EAN–8 07=EAN–13 08=Code 128 09=Pharma–Code 16=Any bb
Symbol number
00=All or 01 to 16 ff
Minimum field length
00 to 64 a
Alignment ppp
Fill character ll
Length of search pattern string
0=Right 1=Left 000 to 255 (000= No alignment) 00=Empty or 01 to 24
Search pattern string up to 24 characters
Length of replace pattern string
00=Empty or 01 to 24
Replace pattern string up to 24 characters nn string ll String
Response:
Parameter Function
01 to 16 00=All or 01 to 16
= rr <end> rr = response code <end> = end of message control code
Publication 2755-833