DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755): 15 - ASCII Host Commands, pages 199 to 208
Pages 199 to 208 of 361, from DS/DD Series B Enhanced Bar Code Decoders User Manual (Bulletin 2755)
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-DD and Allen-Bradley 2755-DS
Page 199
ASCII Host Commands
15–11
CC - Configure Code 39, I 2-of-5, Codabar Check Characters Command Format: CCabcdef Function:
Enables or disables bar code check characters.
Parameters:
abcdef a through f are Yes (1) and No (0) responses to the following parameters (in sequence shown):
Command Parameters a
Parameter Function
Valid Values
Code 39 check character?
1=Yes, 0=No b
Send Code 39 check character?
1=Yes, 0=No c
I 2-of-5 check character?
1=Yes, 0=No d
Send I 2-of-5 check character?
1=Yes, 0=No e
Codabar check character?
1=Yes, 0=No f
Send Codabar check character?
1=Yes, 0=No
= rr <end>
Response:
rr = <end> = response code end of message control code
Example: Command:
CC111100
Parameters:
111100
Command Parameters a
Response:
Parameter Function
Values
Code 39 check character?
1=Yes b
Send Code 39 check character?
1=Yes c
I 2-of-5 check character?
1=Yes d
Send I 2-of-5 check character?
1=Yes e
Codabar check character?
0=No f
Send Codabar check character?
0=No
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 200
15–12
ASCII Host Commands
CG - Configure Interleaved 2-of-5 Guard Bar Command Format: CGa Function:
Enables verification of guard bars on Interleaved 2-of-5 symbols.
Parameters:
a
Command Parameters
Parameter Function a
Enable verification of guard bar on I 2/5 symbols
Valid Values 1=Yes, 0=No
= rr <end>
Response:
rr = response code <end>= end of message control code Example: Command:
CG1
Parameters:
1
Command Parameters
Parameter Function a
Enable verification of guard bar on I 2/5 symbols
Response:
Values 1=Yes
= 00CR 00 = command complete response code CR= end of message control code for Carriage Return.
Publication 2755-833
Page 201
ASCII Host Commands
15–13
CQ - Configure Quiet Zone Command Format: CQaa Function:
Configures the General Quiet Zone Ratio.
Parameters:
aa
Command Parameters aa
Response:
Parameter Function The Quiet Zone Ratio
Valid Values 00 = Defaults 04 – 10
= rr <end> rr = response code <end>= end of message control code
Example: Command:
CQ07
Parameters:
07
Command Parameters aa
Response:
Parameter Function Set Quiet Zone Ratio to 7
Values 07
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 202
15–14
ASCII Host Commands
CF - Configure Code 128 FNC1 Character Command Format: CFaaa Function:
Selects return value for Code 128 FNC1 Character.
Parameters:
aaa
Command Parameters
Parameter Function Select Code 128 FNC1 Character aaa
Valid Values 000 = Discard 001...255 = FNC1 Character
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
CF130
Parameters:
029
Command Parameters aaa
Response:
Parameter Function
Values
Set Code 128 FNC1 return value to 1Dh (029 decimal)
029 (GS group separator)
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return.
Publication 2755-833
Page 203
ASCII Host Commands
15–15
CV - Code Verification List Command Format: CVaabbbb Function:
Defines numeric values for specific data locations of a Pharma-Code bar code symbol.
Parameters:
aabbbb
Command Parameters
Parameter Function
Valid Values aa
Field location
00 to 16 00 means clear Code Verification List (all 16 locations)
bbbb
Pharma-Code data value
0000, 0007 to 8190 0000 clears data value at specified location.
= rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
CV011122
Parameters:
011122
Command Parameters aa bbbb
Response:
Parameter Function
Valid Values
Field location
01
Pharma-Code data value
1122
=00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 204
15–16
ASCII Host Commands
CP - Configure Pharma-Code Symbology Command Format: CPabccddeefgg Function:
Enables the Pharma-Code symbology and configures parameters of the symbology.
Parameters:
abccddeefgg
Command Parameters
Parameter Function a
Enable symbology b
Decode direction cc
Quiet zone ratio dd
Space tolerance ee
Bar tolerance f
Wide to narrow bar ratio gg
Minimum number of bars
Valid Values 0= No 1= Yes 0= Forward 1= Reverse 2= Forward Scanner A Reverse Scanner B① 3= Reverse Scanner A Forward Scanner B① 04 to 10 00=Ignore 05 to 40 00=Ignore 05 to 40 0=midrange 2 to 4 03 to 12
① Applies only to Dual-Head Decoder.
Response:
= rr <end> rr = response code <end>= end of message code
Publication 2755-833
Page 205
ASCII Host Commands
15–17
CP - Configure Pharma-Code Symbology (continued) Example: Command:
CP10040000005
Parameters:
10040000005
Command Parameters a
Enable symbology
1= Yes b
Decode direction
0= Forward
Response:
Parameter Function
Valid Values cc
Quiet zone ratio
04 dd
Space tolerance
00=Ignore ee
Bar tolerance
00=Ignore f
Wide to narrow bar ratio
0=midrange gg
Minimum number of bars
05
=00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 206
15–18
ASCII Host Commands
SC - Configure Scanner A Control Command Format: SCldcsprrrrttttm Function:
Specifies the operating parameters for Scanner A or Scanners A and B in coordinated mode.
Parameters:
ldcsprrrrtttttm
Command Parameters l
Parameter Function Laser-light
Valid Values 0= On 1= Triggered 2= Off 0= Package Detect 1= Host 2= Internal Timer 3= Continuous 4= Continuous/unique 0, 1 through 8 (0= Verify) 0 through 6 0= ANY (1,2,3,4,5,6) 1 -9, A-G (where A=10,...G=16) 0000, 0010 - 9999 (in milliseconds) 0000 disables timeout d
Trigger mode c
Capture count.
s
Bar code symbols per scan p
Bar code symbols per package rrrr
No-read timer value (in milliseconds)
tttt
Inter–scan timer value (in milliseconds)
0000, 0010 - 9999 (in milliseconds) 0000 disables timeout m
Match complete count
1 -9, A-G (where A=10,...G=16)
Important: See Chapter 6 for a description of the Scanner Control parameters. Response:
= rr <end> rr = response code <end> = end of message control code
Publication 2755-833
Page 207
ASCII Host Commands
15–19
SC - Configure Scanner A Control (continued) Example: Command:
SC01211005500001
Parameters:
01211005500001
Command Parameters l
Values
Laser-light
0=Continuous scanning d
Decode trigger mode
1= Host c
Capture count
2 s
Bar code symbols per scan
1 p rrrr tttt m
Response:
Parameter Function
Bar code symbols per package No-read timer value (in milliseconds) Inter–scan timer value (in milliseconds) Match complete count
1 0055= 55 millisecond timer value 0000= Disables inter-scan timer 1
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833
Page 208
15–20
ASCII Host Commands
PB - Configure Scanner B Control Command Format: PBabtttt Function:
Configures Scanner B to operate in coordinated or independent mode. This command also defines the operating parameters for Scanner B when the scanning mode is set to independent. NOTE: This command is valid only for dual head decoders.
Parameters:
abtttt
Command Parameters
Parameter Function
Valid Values a
Scanning mode of scanner B
0= Coordinated 1 1= Independent Package Detect 2= Independent Host Triggered 3= Coordinated 2 b
Reserved
Ignored① tttt
Trigger timeout for scanner B (in milliseconds)
0000, 0010 - 9999 (in milliseconds) 0000 disables timeout
① Decoder ignores character but it must be supplied to maintain compatibility with previous decoders.
Important: See Chapter 7 for a description of the Scanner Control parameters. = rr <end>
Response:
rr = response code <end> = end of message control code Example: Command:
PB110100
Parameters:
110100
Command Parameters
Parameter Function a
Scanning mode of scanner B b
Ignored tttt
Trigger timeout for scanner B (in milliseconds)
Response:
Values 1= Independent Package Detect 1 (Ignored) 0100= 100 milliseconds
= 00CR 00 = command complete response code CR = end of message control code for Carriage Return
Publication 2755-833