Page 309
Factory Default Settings Category of Parameters
Bar Code Symbology
Check Characters
Bar Code Symbology Lengths
Pharma–Code
Scanner A Control
Scanner B Control
Parameter Enable Code 39 Enable Interleaved 2-of-5 Enable Codabar Enable Code 128 Code 128 FNC1 Character
Default Setting Yes (No on Pharma-Code Units) No Guard Bars: No No No None
Enable UPC-A Enable UPC-E Expand UPC-E
No No No
Supplements: None Supplements: None
Enable EAN-8 Enable EAN-13 Code 39
No No No
Supplements: None Supplements: None Include: No
I 2 of 5
No
Include: No
Codabar
No
Include: No
Code 39 Interleaved 2-of-5 Code 128 Codabar Enable Pharma–Code
00, 00, 00, 00, 00, 00, 00, 00 00, 00, 00, 00, 00, 00, 00, 00 00, 00, 00, 00, 00, 00, 00, 00 00, 00, 00, 00, 00, 00, 00, 00 Yes (On Pharma-Code units only)
Quiet Zone Ratio
Default
Space Tolerance
15
Bar Tolerance
15
Wide to Narrow Bar Ratio
2
Minimum Number of Bars
5
Scanner A Decode Direction
Forward
Scanner B Decode Direction
Forward
Code Verification List
Blank
Laser Light Decode Mode No-Read Timer Inter-Scan Timer Capture Count Symbols/Scan Symbols/Package Match Complete Laser Light Decode Mode
Triggered Package Detect None (0000 msec) None (0000 msec) 2 1 1 1 Triggered Coordinated 1
Trigger Timeout
None (0000 msec)
Publication 2755-833
Page 310
B–2
Factory Default Settings
Category of Parameters
Match Code Table (1 - 8)
ac age Detect etect Input Package
Extended Match Code Table
AUX and LCD Display Format
Host Message Replacement Rules
Publication 2755-833
Parameter Bar Code Symbology Match Code Text String Normal State
Default Setting Any Blank O (Normally Open)
Source
A for DS, A|B (A or B) for DD
Duration
0 msec
Scanner A Filter Scanner A Sense Scanner B Filter Scanner B Sense Counter Status
No LO= Package No LO= Package Auto Refresh
Status of Counter Set
Enabled
Mode
Disabled
Source
A for DS, A|B (A or B) for DD
Symbology
Any
Match Pattern String
Blank
Count
0
Loading
Blank (no outputs selected)
Display Data Message Format
None Unformatted
Scroll LCD Display Bar Code Strings Position Decoder Performance Position Package Counter Position Symbols Not Read Counter Position Primary Counter 1 Position Primary Counter 2 Position Primary Counter 3 Position Primary Counter 4 Position Primary Counter 5 Position Primary Counter 6 Position Primary Counter 7 Position Primary Counter 8 Position Rule Number
No 0 0 0
Source
A|B (A or B)
Symbology
Any
Symbol Number
All
Find String Containging
Blank
Replace Entire String With
Blank
Minimum Field Length
0
Alignment
Right
Fill Character
None
Host Message Field Number
All
Bar Code String Examples
Blank
0 0 0 0 0 0 0 0 0 1
Page 311
Factory Default Settings
Category of Parameters
Host Message Format
Parameter Start Character
255 (None)
Source Identifier (for AUX)
Blank
Source Identifier (for A)
Blank
Source Identifier (for B)
Blank
Header String
Blank
Field Delimiter
None
Number of Fields in Message
All
Send Symbology
No
Send Package Count
No
Send Bar Code Strings
Yes
Send Decoder Performance
No
End Message
CrLf
Default No-Read String
Blank
No-Read (1–16)
Replacements
Baud Rate* Bits/Character* Parity* Host Protocol* Device Address* ACK Character* Host Communications NAK Character* Parameters marked with an asterisk Start Character Scanner A require a save and restart to take Stop Character Scanner A effect Start Character Scanner B
Aux Terminal Data Entry
Stop Character Scanner B Large Buffer Send Host Message Transmission Check Enable Keyboard Entry Confirm Entry AUX Data Format Rubout Character Echo Data to Terminal Size of Display Default Prompt Message
B–3
Default Setting
Strings
Blank 9600 8 Data, 1 Stop None RS232 1 255 (None) 255 (None) 255 (Disabled) 255 (Disabled) 255 (Disabled) 255 (Disabled) No At End of Trigger None No No Unformatted 008 BS (Backspace) No 80 Blank
Publication 2755-833